{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,27]],"date-time":"2026-08-27T22:30:48Z","timestamp":1787869848961,"version":"build-2784847793"},"reference-count":94,"publisher":"MDPI AG","issue":"13","license":[{"start":{"date-parts":[[2021,6,24]],"date-time":"2021-06-24T00:00:00Z","timestamp":1624492800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Materials"],"abstract":"<jats:p>In the literature, many researchers investigated static loading effects on an implant. However, dynamic loading under impact loading has not been investigated formally using numerical methods. This study aims to evaluate, with 3D finite element analysis (3D FEA), the stress transferred (maximum peak and variation in time) from a dynamic impact force applied to a single implant-supported prosthesis made from different materials. A 3D implant-supported prosthesis model was created on a digital model of a mandible section using CAD and reverse engineering. By setting different mechanical properties, six implant-supported prostheses made from different materials were simulated: metal (MET), metal-ceramic (MCER), metal-composite (MCOM), carbon fiber-composite (FCOM), PEEK-composite (PKCOM), and carbon fiber-ceramic (FCCER). Three-dimensional FEA was conducted to simulate the collision of 8.62 g implant-supported prosthesis models with a rigid plate at a speed of 1 m\/s after a displacement of 0.01 mm. The stress peak transferred to the crown, titanium abutment, and cortical bone, and the stress variation in time, were assessed.<\/jats:p>","DOI":"10.3390\/ma14133519","type":"journal-article","created":{"date-parts":[[2021,6,24]],"date-time":"2021-06-24T11:01:38Z","timestamp":1624532498000},"page":"3519","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":26,"title":["A 3D Finite Element Analysis Model of Single Implant-Supported Prosthesis under Dynamic Impact Loading for Evaluation of Stress in the Crown, Abutment and Cortical Bone Using Different Rehabilitation Materials"],"prefix":"10.3390","volume":"14","author":[{"given":"Oriol","family":"Cant\u00f3-Nav\u00e9s","sequence":"first","affiliation":[{"name":"Faculty of Dentistry, Universitat Internacional de Catalunya (UIC), 08017 Barcelona, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7557-9200","authenticated-orcid":false,"given":"Raul","family":"Medina-Galvez","sequence":"additional","affiliation":[{"name":"Faculty of Dentistry, Universitat Internacional de Catalunya (UIC), 08017 Barcelona, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7653-6299","authenticated-orcid":false,"given":"Xavier","family":"Marimon","sequence":"additional","affiliation":[{"name":"Bioengineering Institute of Technology, Universitat Internacional de Catalunya (UIC), 08190 Barcelona, Spain"},{"name":"Automatic Control Department, Universitat Polit\u00e8cnica de Catalunya (UPC-BarcelonaTECH), 08034 Barcelona, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4814-0478","authenticated-orcid":false,"given":"Miquel","family":"Ferrer","sequence":"additional","affiliation":[{"name":"Department of Strength of Materials and Structural Engineering, Universitat Polit\u00e8cnica de Catalunya (UPC-BarcelonaTECH), 08034 Barcelona, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8210-4844","authenticated-orcid":false,"given":"\u00d3scar","family":"Figueras-\u00c1lvarez","sequence":"additional","affiliation":[{"name":"Faculty of Dentistry, Universitat Internacional de Catalunya (UIC), 08017 Barcelona, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Josep","family":"Cabratosa-Termes","sequence":"additional","affiliation":[{"name":"Faculty of Dentistry, Universitat Internacional de Catalunya (UIC), 08017 Barcelona, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2021,6,24]]},"reference":[{"key":"ref_1","first-page":"211","article-title":"Osseointegrated implants in the treatment of partially edentulous patients: A preliminary study on 876 consecutively placed fixtures","volume":"4","author":"Jemt","year":"1989","journal-title":"Int. J. Oral Maxillofac. Implant"},{"key":"ref_2","first-page":"347","article-title":"Long-term follow-up study of osseointegrated implants in the treatment of totally edentulous jaws","volume":"5","author":"Adell","year":"1990","journal-title":"Int. J. Oral Maxillofac. Implant"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"188","DOI":"10.1111\/j.1532-849X.2008.00377.x","article-title":"Metal-ceramic alloys in dentistry: A review","volume":"18","author":"Roberts","year":"2009","journal-title":"J Prosthodont"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"223","DOI":"10.1016\/S0022-3913(00)80016-5","article-title":"Biocompatibility of dental casting alloys: A review","volume":"83","author":"Wataha","year":"2000","journal-title":"J. Prosthet. Dent."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"467","DOI":"10.1590\/S1678-77572009000500022","article-title":"The electrochemical propierties of four dental casting suprastructure alloys coupled with titanium implants","volume":"17","author":"Tuna","year":"2009","journal-title":"J. Appl. Oral Sci."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1016\/j.jpor.2019.02.001","article-title":"The influence of prosthetic material on implant and prosthetic survival of implant-supported fixed complete dentures: A systematic review and meta-analysis","volume":"63","author":"Bagegni","year":"2019","journal-title":"J. Prosthodont. Res."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1016\/j.prosdent.2019.07.008","article-title":"Comparison of technical, biological, and esthetic parameters of ceramic and met-al-ceramic implant-supported fixed dental prostheses: A systematic review and meta-analysis","volume":"124","author":"Hu","year":"2019","journal-title":"J. Prosthet. Dent."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"467","DOI":"10.1111\/joor.12272","article-title":"The clinical success of tooth- and implant-supported zirconia-based fixed dental prostheses. A systematic review","volume":"42","author":"Le","year":"2015","journal-title":"J. Oral Rehabil."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"134","DOI":"10.1177\/10454411960070020201","article-title":"Recent advances in ceramics for dentistry","volume":"7","author":"Deany","year":"1996","journal-title":"Crit Rev. Oral Biol. Med."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1111\/joor.12583","article-title":"Analysis of masticatory muscle coordination during unilateral single-tooth clenching using muscle functional magnetic resonance imaging","volume":"45","author":"Yamaguchi","year":"2018","journal-title":"J. Oral Rehabil."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"361","DOI":"10.1111\/j.1365-2842.1987.tb00730.x","article-title":"Masticatory muscle activity as a function of parafunctional, active and passive oral behavioural patterns","volume":"14","author":"Moss","year":"1987","journal-title":"J. Oral Rehabil."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"1595","DOI":"10.1002\/lary.25638","article-title":"Impact of proprioception during the oral phase on initiating the swallowing reflex","volume":"126","author":"Takeda","year":"2016","journal-title":"Laryngoscope"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"616","DOI":"10.5005\/jp-journals-10024-1374","article-title":"Evaluation of the relationship between bruxism and premature occlusal contacts","volume":"14","author":"Safari","year":"2013","journal-title":"J. Contemp. Dent. Pract."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1016\/j.physbeh.2006.01.025","article-title":"Oral physiology and mastication","volume":"89","author":"Engelen","year":"2006","journal-title":"Physiol. Behav."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"357","DOI":"10.1016\/j.archoralbio.2006.09.011","article-title":"Force encoding by human periodontal mechanoreceptors during mastication","volume":"52","author":"Trulsson","year":"2007","journal-title":"Arch. Oral Biol."},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"Cicciu, M., Cervino, G., Milone, D., and Risitano, G. (2018). FEM Investigation of the Stress Distribution over Mandibular Bone Due to Screwed Overdenture Positioned on Dental Implants. Materials, 11.","DOI":"10.3390\/ma11091512"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"549","DOI":"10.11607\/ijp.3241","article-title":"Shock Absorption Capacity of Restorative Materials for Dental Implant Prostheses: An In Vitro Study","volume":"26","author":"Menini","year":"2013","journal-title":"Int. J. Prosthodont."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"249","DOI":"10.1111\/j.1600-0501.2004.00979.x","article-title":"Implant design and interface force transfer","volume":"15","author":"Cehreli","year":"2004","journal-title":"Clin. Oral Implant. Res."},{"key":"ref_19","first-page":"282","article-title":"Shock-absorbing behavior of five restorative materials used on im-plants","volume":"4","author":"Gracis","year":"1991","journal-title":"Int. J. Prosthodont."},{"key":"ref_20","first-page":"118","article-title":"The use of a masticatory robot to analyze the shock absorption capacity of different restorative materials for implant prosthesis","volume":"84","author":"Menini","year":"2011","journal-title":"J. Biol. Res. Boll. Della Soc. Ital. Biol. Sper."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"143","DOI":"10.1111\/j.1600-0501.2011.02311.x","article-title":"Damping behavior of implant-supported restorations","volume":"24","author":"Magne","year":"2011","journal-title":"Clin. Oral Implant. Res."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"227","DOI":"10.1016\/j.prosdent.2004.12.019","article-title":"Three-dimensional finite element analysis of the effect of differ-ent bone quality on stress distribution in an implant-supported crown","volume":"93","author":"Sevimay","year":"2005","journal-title":"J. Prosthet. Dent."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"929","DOI":"10.1016\/j.jds.2020.11.005","article-title":"The investigation of the stress distribution in abutment teeth for connected crowns","volume":"16","author":"Mizusawa","year":"2021","journal-title":"J. Dent. Sci."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"437","DOI":"10.1016\/j.prosdent.2017.03.008","article-title":"Effect of different restorative crown and customized abutment materials on stress distribution in single implants and peripheral bone: A three-dimensional finite element analysis study","volume":"119","author":"Kaleli","year":"2018","journal-title":"J. Prosthet. Dent."},{"key":"ref_25","first-page":"347","article-title":"Static, Dynamic, and Fatigue Finite Element Analysis of Dental Implants with Different Thread Designs","volume":"26","author":"Geramizadeh","year":"2016","journal-title":"J. Autom. Inf. Sci."},{"key":"ref_26","first-page":"25","article-title":"Finite Element Analysis of Dental Implants with and without Microthreads under Static and Dynamic Loading","volume":"27","author":"Geramizadeh","year":"2017","journal-title":"J. Autom. Inf. Sci."},{"key":"ref_27","first-page":"20190041","article-title":"Anomalous strain energy transformation pathways in mechanical metamaterials","volume":"475","author":"Karpov","year":"2019","journal-title":"Proc. Math. Phys. Eng. Sci."},{"key":"ref_28","unstructured":"King, H. (2018). Basic Finite Element Method Apllied to Injury Biomechanics, Academic Press."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"104092","DOI":"10.1016\/j.jmbbm.2020.104092","article-title":"Comparison between experimental digital image processing and numerical methods for stress analysis in dental implants with different restorative materials","volume":"113","author":"Marimon","year":"2021","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"646","DOI":"10.1016\/j.msec.2016.09.047","article-title":"Biological and mechanical characterization of carbon fiber frameworks for dental implant applications","volume":"70","author":"Menini","year":"2017","journal-title":"Mater. Sci. Eng. C"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1016\/j.jmbbm.2010.09.011","article-title":"Biomechanical comparison of implant retained fixed partial dentures with fiber reinforced composite versus conventional metal frameworks: A 3D FEA study","volume":"4","author":"Erkmen","year":"2011","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"264","DOI":"10.1016\/j.jpor.2017.10.002","article-title":"Metal free, full arch, fixed prosthesis for edentulous mandible rehabilitation on four implants","volume":"62","author":"Passaretti","year":"2018","journal-title":"J. Prosthodont. Res."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1016\/j.msec.2017.07.052","article-title":"Photoelastic analysis of mandibular full-arch implant-supported fixed dentures made with different bar materials and manufacturing techniques","volume":"81","author":"Zaparolli","year":"2017","journal-title":"Mater. Sci. Eng. C"},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"392","DOI":"10.1111\/joor.12493","article-title":"Carbon fibre versus metal framework in full-arch immediate loading rehabilitations of the maxilla-a cohort clinical study","volume":"44","author":"Pera","year":"2017","journal-title":"J. Oral Rehabil."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"845","DOI":"10.1016\/j.dental.2008.12.007","article-title":"Effect of thermal cycling on flexural properties of carbon-graphite fiber-reinforced polymers","volume":"25","author":"Segerstrom","year":"2009","journal-title":"Dent. Mater."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"1169","DOI":"10.1016\/j.dental.2009.04.009","article-title":"Adhesion properties in systems of laminated pigmented polymers, carbon-graphite fiber composite framework and titanium surfaces in implant suprastructures","volume":"25","author":"Segerstrom","year":"2009","journal-title":"Dent. Mater."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"246","DOI":"10.1111\/j.1600-0722.2011.00826.x","article-title":"Biological and physicochemical properties of carbon-graphite fi-bre-reinforced polymers intended for implant suprastructures","volume":"119","author":"Segerstrom","year":"2011","journal-title":"Eur. J. Oral Sci."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"382","DOI":"10.1016\/j.sdentj.2019.03.005","article-title":"Determination of Polyetheretherketone (PEEK) mechanical properties as a denture material","volume":"31","author":"Muhsin","year":"2019","journal-title":"Saudi Dent. J."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"295","DOI":"10.1016\/j.jmbbm.2015.10.003","article-title":"Pressure behavior of different PEEK materials for dental implants","volume":"54","author":"Schwitalla","year":"2016","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"1377","DOI":"10.1016\/j.dental.2015.08.151","article-title":"Flexural behavior of PEEK materials for dental application","volume":"31","author":"Schwitalla","year":"2015","journal-title":"Dent. Mater."},{"key":"ref_41","first-page":"524","article-title":"Immediate loading with fixed screw-retained provisional restorations in edentulous jaws: The pickup technique","volume":"19","author":"Gallucci","year":"2004","journal-title":"Int. J. Oral Maxillofac. Implant."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"290","DOI":"10.1034\/j.1600-0501.1997.080407.x","article-title":"An in vitro evaluation of the strength of an internal conical interface compared to a butt joint interface in implant design","volume":"8","author":"Norton","year":"1997","journal-title":"Clin. Oral Implant. Res."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"401","DOI":"10.1563\/AAID-JOI-D-10-00044","article-title":"Photoelastic analysis of ce-mented or screwed implant-supported prostheses with different prosthetic connections","volume":"37","author":"Tonella","year":"2011","journal-title":"J. Oral Implantol."},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"103556","DOI":"10.1016\/j.jmbbm.2019.103556","article-title":"In vitro digital image correlation analysis of the strain transferred by screw-retained fixed partial dentures supported by short and conventional implants","volume":"103","author":"Peixoto","year":"2020","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"718","DOI":"10.1016\/j.engstruct.2012.08.018","article-title":"Experimental accuracy of two dimensional strain measurements using Digital Image Correlation","volume":"46","author":"Hoult","year":"2013","journal-title":"Eng. Struct."},{"key":"ref_46","first-page":"17","article-title":"In Vivo registration of force development with ceramic and acrylic resin occlusal materials on implant-supported prostheses","volume":"17","author":"Bassit","year":"2002","journal-title":"Int. J. Oral Maxillofac. Implants."},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"172","DOI":"10.1111\/j.2041-1626.2012.00149.x","article-title":"Stress dissipation in the bone through various crown materials of dental implant restoration: A 2-D finite element analysis","volume":"4","author":"Bijjargi","year":"2012","journal-title":"J. Investig. Clin. Dent."},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"140","DOI":"10.1002\/jbm.b.30191","article-title":"The influence of various occlusal materials on stresses transferred to im-plant-supported prostheses and supporting bone: A three-dimensional finite-element study","volume":"73","author":"Sevimay","year":"2005","journal-title":"J. Biomed. Mater. Res. B Appl. Biomater."},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"239","DOI":"10.2334\/josnusd.55.239","article-title":"Stress distribution in fixed-partial prosthesis and peri-implant bone tissue with different framework materials and vertical misfit levels: A three-dimensional finite element analysis","volume":"55","author":"Bacchi","year":"2013","journal-title":"J. Oral Sci."},{"key":"ref_50","first-page":"519","article-title":"Mechanics of the implant-abutment connection: An 8-degree taper compared to a butt joint connection","volume":"15","author":"Merz","year":"2000","journal-title":"Int. J. Oral Maxillofac. Implant."},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"927","DOI":"10.1016\/j.dental.2020.04.013","article-title":"Finite element analysis of narrow dental implants","volume":"36","year":"2020","journal-title":"Dent. Mater."},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1563\/AAID-JOI-D-12-00260","article-title":"Stress Distribution Around Osseointegrated Implants With Different Internal-Cone Connections: Photoelastic and Finite Element Analysis","volume":"41","author":"Anami","year":"2015","journal-title":"J. Oral Implant."},{"key":"ref_53","doi-asserted-by":"crossref","first-page":"1350","DOI":"10.3390\/app5041350","article-title":"New Trends in Dental Biomechanics with Photonics Technologies","volume":"5","author":"Carvalho","year":"2015","journal-title":"Appl. Sci."},{"key":"ref_54","first-page":"50","article-title":"Biomechanical methods applied in dentistry: A comparative overview of photoelastic examinations, strain gauge measurements, finite element analysis and three-dimensional deformation analysis","volume":"17","author":"Karl","year":"2009","journal-title":"Eur. J. Prosthodont. Restor. Dent."},{"key":"ref_55","doi-asserted-by":"crossref","unstructured":"Benazzi, S., Nguyen, H.N., Kullmer, O., and Kupczik, K. (2016). Dynamic Modelling of Tooth Deformation Using Occlusal Kinematics and Finite Element Analysis. PLoS ONE, 11.","DOI":"10.1371\/journal.pone.0152663"},{"key":"ref_56","doi-asserted-by":"crossref","first-page":"1","DOI":"10.4015\/S1016237216500149","article-title":"Dynamic simulation and finite element analysis of the maxillary bone injury around dental implant during chewing different food","volume":"28","author":"Razaghi","year":"2016","journal-title":"Biomed. Eng. Appl. Basis. Commun."},{"key":"ref_57","doi-asserted-by":"crossref","first-page":"649","DOI":"10.1016\/j.advengsoft.2006.02.004","article-title":"Static, dynamic and fatigue behaviors of dental implant using finite element method","volume":"37","year":"2006","journal-title":"Adv. Eng. Softw."},{"key":"ref_58","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s40729-018-0119-5","article-title":"Finite element analysis of dental implants with validation: To what extent can we expect the model to predict biological phenomena? A literature review and proposal for classification of a validation process","volume":"4","author":"Chang","year":"2018","journal-title":"Int. J. Implant Dent."},{"key":"ref_59","doi-asserted-by":"crossref","first-page":"282","DOI":"10.1111\/j.1600-051X.2008.01283.x","article-title":"Peri-implant diseases: Consensus Report of the Sixth European Workshop on Periodontology","volume":"35","author":"Lindhe","year":"2008","journal-title":"J. Clin. Periodontol."},{"key":"ref_60","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1111\/j.1600-051X.2010.01692.x","article-title":"Seventh European Workshop on Periodontol-ogy of the European Academy of Periodontology at the Parador at la Granja, Segovia, Spain","volume":"38","author":"Sanz","year":"2011","journal-title":"J. Clin. Periodontol."},{"key":"ref_61","first-page":"3","article-title":"Consensus Report: 2nd European Workshop on Tobacco Use Prevention and Cessation for Oral Health Professionals","volume":"60","author":"Ramseier","year":"2010","journal-title":"Int. Dent. J."},{"key":"ref_62","doi-asserted-by":"crossref","first-page":"e12398","DOI":"10.1111\/jicd.12398","article-title":"Peri-implantitis risk factors: A pro-spective evaluation","volume":"10","author":"Mazel","year":"2019","journal-title":"J. Investig. Clin. Dent."},{"key":"ref_63","doi-asserted-by":"crossref","first-page":"1202","DOI":"10.1177\/0022034515590581","article-title":"The Influence of Smoking on the Peri-Implant Microbiome","volume":"94","author":"Tsigarida","year":"2015","journal-title":"J. Dent. Res."},{"key":"ref_64","doi-asserted-by":"crossref","first-page":"S158","DOI":"10.1111\/jcpe.12334","article-title":"Peri-implant health and disease. A systematic review of current epidemiology","volume":"42","author":"Derks","year":"2015","journal-title":"J. Clin. Periodontol."},{"key":"ref_65","doi-asserted-by":"crossref","first-page":"783","DOI":"10.1111\/joor.12195","article-title":"The effect of loading on peri-implant bone: A critical review of the literature","volume":"41","author":"Duyck","year":"2014","journal-title":"J. Oral Rehabil."},{"key":"ref_66","doi-asserted-by":"crossref","first-page":"95","DOI":"10.1111\/j.1600-0501.2012.02550.x","article-title":"Occlusal overload and bone\/implant loss","volume":"23","author":"Naert","year":"2012","journal-title":"Clin. Oral Implant Res."},{"key":"ref_67","doi-asserted-by":"crossref","first-page":"108","DOI":"10.1111\/j.1600-0501.2012.02555.x","article-title":"Peri-implant tissue destruction. The Third EAO Consensus Conference 2012","volume":"23","author":"Klinge","year":"2012","journal-title":"Clin. Oral Implants Res."},{"key":"ref_68","doi-asserted-by":"crossref","first-page":"145","DOI":"10.1111\/j.1399-302X.1987.tb00298.x","article-title":"The microbiota associated with successful or failing osseointe-grated titanium implants","volume":"2","author":"Mombelli","year":"1987","journal-title":"Oral Microbiol. Immunol."},{"key":"ref_69","doi-asserted-by":"crossref","first-page":"601","DOI":"10.1111\/j.1600-0501.2007.01374.x","article-title":"Impact of implant overloading on the pe-ri-implant bone in inflamed and non-inflamed peri-implant mucosa","volume":"18","author":"Kozlovsky","year":"2007","journal-title":"Clin. Oral Implants Res."},{"key":"ref_70","doi-asserted-by":"crossref","first-page":"92","DOI":"10.1038\/sj.ebd.6401193","article-title":"Lack of association between overload and peri-implant tissue loss in healthy conditions","volume":"17","author":"Afrashtehfar","year":"2016","journal-title":"Evid. Based Dent."},{"key":"ref_71","doi-asserted-by":"crossref","first-page":"527","DOI":"10.1046\/j.0909-8836..t01-2-.x","article-title":"Biological factors contributing to failures of osseointegrated oral implants, (I). Success criteria and epidemiology","volume":"106","author":"Esposito","year":"1998","journal-title":"Eur. J. Oral Sci."},{"key":"ref_72","doi-asserted-by":"crossref","first-page":"E1","DOI":"10.1038\/sj.bdj.2012.1","article-title":"Specialists\u2019 management decisions and attitudes towards mucositis and peri-implantitis","volume":"212","author":"Mattheos","year":"2012","journal-title":"Br. Dent. J."},{"key":"ref_73","doi-asserted-by":"crossref","first-page":"1372","DOI":"10.1902\/jop.2001.72.10.1372","article-title":"Influence of the size of the microgap on crestal bone changes around titanium implants. A histometric evaluation of unloaded non-submerged implants in the canine mandible","volume":"72","author":"Schenk","year":"2001","journal-title":"J. Periodontol."},{"key":"ref_74","doi-asserted-by":"crossref","first-page":"1307","DOI":"10.1016\/j.msec.2005.08.019","article-title":"Effect of bonedensity on thedampingbehavior of dental implants: An in vitro method","volume":"26","author":"Sheets","year":"2006","journal-title":"Mater. Sci. Eng."},{"key":"ref_75","doi-asserted-by":"crossref","first-page":"264","DOI":"10.11607\/jomi.4797","article-title":"Biomechanical Behavior of the Dental Implant Macrodesign","volume":"32","author":"Carvalho","year":"2017","journal-title":"Int. J. Oral Maxillofac. Implants"},{"key":"ref_76","doi-asserted-by":"crossref","first-page":"915","DOI":"10.1111\/clr.13344","article-title":"Risk factor model of mechanical complica-tions in implant-supported fixed complete dentures: A prospective cohort study","volume":"29","author":"Coltro","year":"2018","journal-title":"Clin. Oral Implants Res."},{"key":"ref_77","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1179\/2151090314Y.0000000009","article-title":"The craniofacial morphology and maximum bite force in sleep bruxism patients with signs and symptoms of temporomandibular disorders","volume":"33","author":"Karakis","year":"2014","journal-title":"CRANIO\u00ae"},{"key":"ref_78","doi-asserted-by":"crossref","first-page":"71","DOI":"10.2147\/CCIDE.S70715","article-title":"Sleep bruxism: Challenges and restorative solutions","volume":"8","author":"Mengatto","year":"2016","journal-title":"Clin. Cosmet. Investig. Dent."},{"key":"ref_79","doi-asserted-by":"crossref","first-page":"296","DOI":"10.11607\/ijp.4610","article-title":"Impact of Bruxism on Ceramic Defects in Implant-Borne Fixed Dental Prostheses: A Retrospective Study","volume":"29","author":"Mikeli","year":"2016","journal-title":"Int. J. Prosthodont."},{"key":"ref_80","doi-asserted-by":"crossref","first-page":"2075","DOI":"10.1002\/jbm.a.36060","article-title":"Basis of bone metabolism around dental implants during osseointegration and peri-implant bone loss","volume":"105","author":"Insua","year":"2017","journal-title":"J. Biomed. Mater. Res. Part A"},{"key":"ref_81","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1111\/adj.12018","article-title":"Age-related changes in maxillary and mandibular cortical bone thickness in relation to temporary anchorage device placement","volume":"8","author":"Sathapana","year":"2013","journal-title":"Aust. Dent. J."},{"key":"ref_82","doi-asserted-by":"crossref","first-page":"021021","DOI":"10.1115\/1.2903434","article-title":"Modeling of Dynamic Fracture and Damage in Two-Dimensional Trabecular Bone Microstructures Using the Cohesive Finite Element Method","volume":"130","author":"Tomar","year":"2008","journal-title":"J. Biomech. Eng."},{"key":"ref_83","doi-asserted-by":"crossref","first-page":"822","DOI":"10.1177\/0022034517700131","article-title":"Relationships among Bone Quality, Implant Osseointegration, and Wnt Signaling","volume":"96","author":"Li","year":"2017","journal-title":"J. Dent. Res."},{"key":"ref_84","doi-asserted-by":"crossref","first-page":"477","DOI":"10.1111\/eos.12657","article-title":"Role of epigenetics in alveolar bone resorption and regeneration around periodontal and peri-implant tissues","volume":"127","author":"Monje","year":"2019","journal-title":"Eur. J. Oral Sci."},{"key":"ref_85","unstructured":"(2019, May 15). Solidworks Dassault Systemes. Available online: http:\/\/www.solidworks.com."},{"key":"ref_86","unstructured":"Micro Medica Srl (2019, May 15). Available online: http:\/\/micromedicasrl.it."},{"key":"ref_87","unstructured":"Renishaw (2019, May 15). Available online: https:\/\/www.renishaw.com."},{"key":"ref_88","unstructured":"VITA Zahnfabrik, H. (2019, May 15). Rauter GmbH & Co 2021. Germany. Available online: www.vita-zahnfabrik.com."},{"key":"ref_89","doi-asserted-by":"crossref","unstructured":"Heraeus Kulzer GmbH (2019, May 15). Available online: https:\/\/www.kulzer.de.","DOI":"10.1007\/s11428-018-0440-x"},{"key":"ref_90","unstructured":"(2019, May 15). Ivoclar Vivadent 2021. Available online: https:\/\/www.ivoclarvivadent.es."},{"key":"ref_91","unstructured":"(2019, May 15). Invibio 2021. Available online: https:\/\/invibio.com."},{"key":"ref_92","unstructured":"MIS Implants Technologies Ltd. (2019, May 15). Available online: https:\/\/www.mis-implants.com."},{"key":"ref_93","doi-asserted-by":"crossref","first-page":"470539","DOI":"10.1155\/2014\/470539","article-title":"Material Properties of the Mandibular Trabecular Bone","volume":"2014","author":"Lakatos","year":"2014","journal-title":"J. Med. Eng."},{"key":"ref_94","doi-asserted-by":"crossref","first-page":"585","DOI":"10.1067\/mpr.2001.115251","article-title":"Application of finite element analysis in implant dentistry: A review of the literature","volume":"85","author":"Geng","year":"2001","journal-title":"J. Pros-thet. Dent."}],"container-title":["Materials"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1996-1944\/14\/13\/3519\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T06:22:58Z","timestamp":1760163778000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1996-1944\/14\/13\/3519"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,6,24]]},"references-count":94,"journal-issue":{"issue":"13","published-online":{"date-parts":[[2021,7]]}},"alternative-id":["ma14133519"],"URL":"https:\/\/doi.org\/10.3390\/ma14133519","relation":{},"ISSN":["1996-1944"],"issn-type":[{"value":"1996-1944","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,6,24]]}}}