{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,16]],"date-time":"2026-10-16T18:28:22Z","timestamp":1792175302514,"version":"4.4.0"},"reference-count":202,"publisher":"MDPI AG","issue":"1","license":[{"start":{"date-parts":[[2022,12,24]],"date-time":"2022-12-24T00:00:00Z","timestamp":1671840000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Materials"],"abstract":"<jats:p>Objectives: From the treatment of damaged teeth to replacing missing teeth, dental biomaterials cover the scientific interest of many fields. Dental biomaterials are one of the implants whose effective life depends vastly on their material and manufacturing techniques. The purpose of this review is to summarize the important aspects for metallic dental implants from biomedical, mechanical and materials science perspectives. The review article will focus on five major aspects as mentioned below. Tooth anatomy: Maximizing the implant performance depends on proper understanding of human tooth anatomy and the failure behavior of the implants. Major parts from tooth anatomy including saliva characteristics are explored in this section. Wear mechanisms: The prominent wear mechanisms having a high impact on dental wear are abrasive, adhesive, fatigue and corrosion wear. To imitate the physiological working condition of dental implants, reports on the broad range of mastication force and various composition of artificial saliva have been included in this section, which can affect the tribo-corrosion behavior of dental implants. Dental implants classifications: The review paper includes a dedicated discussion on major dental implants types and their details for better understanding their applicability and characteristics. Implant materials: As of today, the most established dental implant materials are SS316L, cobalt chrome alloy and titanium. Detailed discussion on their material properties, microstructures, phase transformations and chemical compositions have been discussed here. Manufacturing techniques: In terms of different production methods, the lost wax casting method as traditional manufacturing is considered. Selective Laser Melting (SLM) and Directed Energy Deposition (DED) as additive manufacturing techniques (AM) have been discussed. For AM, the relationships between process\u2013property\u2013performance details have been explored briefly. The effectiveness of different manufacturing techniques was compared based on porosity distribution, mechanical and biomechanical properties. Summary: Despite having substantial research available on dental implants, there is a lack of systematic reviews to present a holistic viewpoint combining state-of-the-art from biomedical, mechanical, materials science and manufacturing perspectives. This review article attempts to combine a wide variety of analyzing approaches from those interdisciplinary fields to deliver deeper insights to researchers both in academia and industry to develop next-generation dental implants.<\/jats:p>","DOI":"10.3390\/ma16010161","type":"journal-article","created":{"date-parts":[[2022,12,27]],"date-time":"2022-12-27T02:55:07Z","timestamp":1672109707000},"page":"161","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":88,"title":["Metallic Dental Implants Wear Mechanisms, Materials, and Manufacturing Processes: A Literature Review"],"prefix":"10.3390","volume":"16","author":[{"given":"Sudip","family":"Saha","sequence":"first","affiliation":[{"name":"Department of Mechanical Engineering, University of North Dakota, Grand Forks, ND 58202, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2950-1290","authenticated-orcid":false,"given":"Sougata","family":"Roy","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, University of North Dakota, Grand Forks, ND 58202, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2022,12,24]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1111\/jtxs.12411","article-title":"The role of saliva in oral processing: Reconsidering the breakdown path paradigm","volume":"51","author":"Boehm","year":"2020","journal-title":"J. Texture Stud."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"140","DOI":"10.1016\/0300-5712(92)90125-V","article-title":"Wear in dentistry-current terminology","volume":"20","author":"Mair","year":"1992","journal-title":"J. Dent."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"181","DOI":"10.1007\/s11249-006-9192-7","article-title":"Study of in vitro wear of human tooth enamel","volume":"26","author":"Zheng","year":"2007","journal-title":"Tribol. Lett."},{"key":"ref_4","doi-asserted-by":"crossref","unstructured":"Lanza, A., Ruggiero, A., and Sbordone, L. (2019). Tribology and dentistry: A commentary. Lubricants, 7.","DOI":"10.3390\/lubricants7060052"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"50","DOI":"10.5125\/jkaoms.2014.40.2.50","article-title":"Current trends in dental implants","volume":"40","author":"Gaviria","year":"2014","journal-title":"J. Korean Assoc. Oral Maxillofac. Surg."},{"key":"ref_6","first-page":"431","article-title":"Status of surface treatment in endosseous implant: A literary overview Controlling the Bone Implant Interface by Biomaterial Selection and Modification Physicochemical Method","volume":"21","author":"Ankur","year":"2021","journal-title":"Indian J. Dent. Res."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1016\/j.morpho.2016.02.002","article-title":"Dental implants: A review [Les implants dentaires: Revue]","volume":"100","author":"Guillaume","year":"2016","journal-title":"Morphologie"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"932","DOI":"10.3390\/ma8030932","article-title":"A critical review of dental implant materials with an emphasis on titanium versus zirconia","volume":"8","author":"Osman","year":"2015","journal-title":"Materials"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"52","DOI":"10.12998\/wjcc.v3.i1.52","article-title":"Implant biomaterials: A comprehensive review","volume":"3","author":"Saini","year":"2015","journal-title":"World J. Clin. Cases"},{"key":"ref_10","doi-asserted-by":"crossref","unstructured":"Edelmann, A., Riedel, L., and Hellmann, R. (2020). Realization of a dental framework by 3D printing in material cobalt-chromium with superior precision and fitting accuracy. Materials, 13.","DOI":"10.3390\/ma13235390"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"1348","DOI":"10.3390\/ma5081348","article-title":"A review of Titanium Zirconium (TiZr) alloys for use in endosseous dental implants","volume":"5","author":"Berner","year":"2012","journal-title":"Materials"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"231","DOI":"10.1016\/S0921-5093(97)00806-X","article-title":"Mechanical properties of biomedical titanium alloys","volume":"243","author":"Mitsuo","year":"1998","journal-title":"Mater. Sci. Eng. A"},{"key":"ref_13","first-page":"347","article-title":"Long-term follow-up study of osseointegrated implants in the treatment of totally edentulous jaws","volume":"5","author":"Adell","year":"1990","journal-title":"Int. J. Oral Maxillofac. Implant."},{"key":"ref_14","doi-asserted-by":"crossref","unstructured":"Baltatu, M.S., Vizureanu, P., Sandu, A.V., Florido-Suarez, N., Saceleanu, M.V., and Mirza-Rosca, J.C. (2021). New titanium alloys, promising materials for medical devices. Materials, 14.","DOI":"10.3390\/ma14205934"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"012030","DOI":"10.1088\/1757-899X\/374\/1\/012030","article-title":"Noninvasive Evaluation of Special Alloys for Prostheses Using Complementary Methods","volume":"374","author":"Savin","year":"2018","journal-title":"IOP Conf. Ser. Mater. Sci. Eng."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"2459","DOI":"10.1016\/S0142-9612(01)00380-5","article-title":"Fracture mechanisms of retrieved titanium screw thread in dental implant","volume":"23","author":"Yokoyama","year":"2002","journal-title":"Biomaterials"},{"key":"ref_17","first-page":"26","article-title":"Theoretical analysis of the fatigue life of fixture screws in osseointegrated dental implants","volume":"7","author":"Patterson","year":"1992","journal-title":"Int. J. Oral Maxillofac. Implant."},{"key":"ref_18","first-page":"409","article-title":"Fractures of the fixture component of an osseointegrated implant","volume":"8","author":"Morgan","year":"1993","journal-title":"Int. J. Oral Maxillofac. Implant."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"115403","DOI":"10.1088\/2053-1591\/aadc55","article-title":"Effect of using different metal and ceramic materials as restorations on stress distribution around dental implants: A comparative finite element study","volume":"5","author":"Ezatpour","year":"2018","journal-title":"Mater. Res. Express"},{"key":"ref_20","first-page":"655","article-title":"Osteointegration of Biomimetic Apatite Coating Applied onto Dense and Porous Metal Implants in Femurs of Goats","volume":"67","author":"Meijer","year":"2003","journal-title":"J. Biomed. Mater. Res.\u2014Part B Appl. Biomater."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"287","DOI":"10.1111\/j.1600-0501.2011.02206.x","article-title":"Failure analysis of fractured dental zirconia implants","volume":"23","author":"Gahlert","year":"2012","journal-title":"Clin. Oral Implant. Res."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"592","DOI":"10.1111\/j.1600-0501.2011.02411.x","article-title":"Fractured zirconia implants and related implant designs: Scanning electron microscopy analysis","volume":"24","author":"Osman","year":"2013","journal-title":"Clin. Oral Implant. Res."},{"key":"ref_23","unstructured":"Spiller, M.S. (2017). Castable Metal Alloys in Dentistry. Dmd, 2\u201333. Available online: https:\/\/www.dentallearning.org\/course\/DentalAlloys\/CastableMetalAlloys.pdf."},{"key":"ref_24","first-page":"171","article-title":"The analysis of the mechanical properties of F75 Co-Cr alloy for use in selective laser melting (SLM) manufacturing of removable partial dentures (RPD)","volume":"51","author":"Jevremovic","year":"2012","journal-title":"Metalurgija"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"1289","DOI":"10.14219\/jada.archive.2006.0389","article-title":"Computer-aided design and fabrication of dental restorations: Current systems and future possibilities","volume":"137","author":"Strub","year":"2006","journal-title":"J. Am. Dent. Assoc."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1016\/j.prosdent.2016.11.004","article-title":"A comparative study of additive and subtractive manufacturing for dental restorations","volume":"118","author":"Bae","year":"2017","journal-title":"J. Prosthet. Dent."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"588","DOI":"10.1111\/jopr.12154","article-title":"Removable partial dentures: Use of rapid prototyping","volume":"23","author":"Lima","year":"2014","journal-title":"J. Prosthodont."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"1569","DOI":"10.1515\/amm-2015-0274","article-title":"Selected properties and tribological wear alloys Co-Cr-Mo and Co-Cr-Mo-W used in dental prosthetics","volume":"60","author":"Kurtyka","year":"2015","journal-title":"Arch. Metall. Mater."},{"key":"ref_29","first-page":"2328","article-title":"Effect of Pretreatment Process on the Metal-Porcelain Bonding Mechanism and Properties of CoCr Alloy Dental Crown and Bridge Manufactured by SLM","volume":"47","author":"Wang","year":"2018","journal-title":"Xiyou Jinshu Cailiao Yu Gongcheng\/Rare Met. Mater. Eng."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"146","DOI":"10.1016\/j.jmst.2019.11.031","article-title":"Microstructural features of biomedical cobalt\u2013chromium\u2013molybdenum (CoCrMo) alloy from powder bed fusion to aging heat treatment","volume":"45","author":"Li","year":"2020","journal-title":"J. Mater. Sci. Technol."},{"key":"ref_31","doi-asserted-by":"crossref","unstructured":"Li, Z., Cui, Y., Wang, J., Liu, C., Wang, J., Xu, T., Lu, T., Zhang, H., Lu, J., and Ma, S. (2019). Characterization of microstructure and mechanical properties of stellite 6 part fabricated by wire arc additive manufacturing. Metals, 9.","DOI":"10.3390\/met9040474"},{"key":"ref_32","first-page":"25","article-title":"Stainless Steel Alloys for Dental Application: Corrosion Behaviour in the Presence of Toothpaste Vicco","volume":"9","author":"Souza","year":"2017","journal-title":"Der Pharma Chem."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"5093","DOI":"10.48084\/etasr.3208","article-title":"A Comparative Study of 316L Stainless Steel and a Titanium Alloy in an Aggressive Biological Medium","volume":"9","author":"Aroussi","year":"2019","journal-title":"Eng. Technol. Appl. Sci. Res."},{"key":"ref_34","first-page":"1","article-title":"Study of corrosion between a titanium implant and dental alloys","volume":"31","author":"Reclaru","year":"2003","journal-title":"J. Dent."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"696","DOI":"10.1080\/10667857.2016.1212780","article-title":"Current advances in enhancement of wear and corrosion resistance of titanium alloys\u2014A review","volume":"31","author":"Revathi","year":"2016","journal-title":"Mater. Technol."},{"key":"ref_36","doi-asserted-by":"crossref","unstructured":"Lozano, P., Pe\u00f1a, M., Herrero-Climent, M., Rios-Santos, J.V., Rios-Carrasco, B., Brizuela, A., and Gil, J. (2022). Corrosion Behavior of Titanium Dental Implants with Implantoplasty. Materials, 15.","DOI":"10.3390\/ma15041563"},{"key":"ref_37","doi-asserted-by":"crossref","unstructured":"Figueiredo-Pina, C.G., Moreira, V., Cola\u00e7o, R., and Serro, A.P. (2015, January 26\u201327). Tribocorrosion in dental implants: An in-vitro study. Proceedings of the VIII International Scientific Conference, Dedicated to 50th Anniversary Year of Tribology, Aleksandras Stulginskis University, Kaunas, Lithuania.","DOI":"10.15544\/balttrib.2015.22"},{"key":"ref_38","doi-asserted-by":"crossref","unstructured":"Alemanno, F., Peretti, V., Tortora, A., and Spriano, S. (2020). Tribological behaviour of Ti or Ti alloy vs. zirconia in presence of artificial saliva. Coatings, 10.","DOI":"10.3390\/coatings10090851"},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"164","DOI":"10.1016\/j.jmbbm.2018.12.009","article-title":"Influence of contact configuration and lubricating conditions on the microtriboactivity of the zirconia-Ti6Al4V pair used in dental applications","volume":"91","author":"Branco","year":"2019","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"ref_40","doi-asserted-by":"crossref","unstructured":"Osak, P., Maszybrocka, J., Kubisztal, J., and \u0141osiewicz, B. (2022). Effect of amorphous calcium phosphate coatings on tribological properties of titanium grade 4 in protein-free artificial saliva. Biotribology, 32.","DOI":"10.1016\/j.biotri.2022.100219"},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"405","DOI":"10.1016\/j.prosdent.2014.09.021","article-title":"Effect of the coefficient of friction and tightening speed on the preload induced at the dental implant complex with the finite element method","volume":"113","author":"Bulaqi","year":"2015","journal-title":"J. Prosthet. Dent."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"138","DOI":"10.4047\/jap.2014.6.2.138","article-title":"Physico-mechanical properties and prosthodontic applications of Co-Cr dental alloys: A review of the literature","volume":"6","year":"2014","journal-title":"J. Adv. Prosthodont."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"100","DOI":"10.3390\/prosthesis2020011","article-title":"Titanium Alloys for Dental Implants: A Review","volume":"2","author":"Nicholson","year":"2020","journal-title":"Prosthesis"},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"147","DOI":"10.4103\/2231-0762.158014","article-title":"Zirconia in dental implantology: A review","volume":"5","author":"Apratim","year":"2015","journal-title":"J. Int. Soc. Prev. Community Dent."},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"1227","DOI":"10.1177\/0885328219899523","article-title":"Production of inter-connective porous dental implants by computer-aided design and metal three-dimensional printing","volume":"34","author":"Chen","year":"2020","journal-title":"J. Biomater. Appl."},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"150","DOI":"10.1016\/j.promfg.2017.08.019","article-title":"Application of a Hybrid Additive Manufacturing Methodology to Produce a Metal\/Polymer Customized Dental Implant","volume":"12","author":"Silva","year":"2017","journal-title":"Procedia Manuf."},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"303","DOI":"10.1111\/jopr.12268","article-title":"Selective Laser Melting Technique of Co-Cr Dental Alloys: A Review of Structure and Properties and Comparative Analysis with Other Available Techniques","volume":"24","author":"Koutsoukis","year":"2015","journal-title":"J. Prosthodont."},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1016\/j.prosdent.2019.07.008","article-title":"Comparison of technical, biological, and esthetic parameters of ceramic and metal-ceramic implant-supported fixed dental prostheses: A systematic review and meta-analysis","volume":"124","author":"Hu","year":"2020","journal-title":"J. Prosthet. Dent."},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1067\/mpr.2001.118021","article-title":"A review of 243 errors possible during the fabrication of a removable partial denture: Part I","volume":"86","author":"Rudd","year":"2001","journal-title":"J. Prosthet. Dent."},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"377","DOI":"10.1016\/j.prosdent.2005.04.018","article-title":"Effect of implant size and shape on implant success rates: A literature review","volume":"94","author":"Lee","year":"2005","journal-title":"J. Prosthet. Dent."},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"1276","DOI":"10.1902\/jop.2000.72.9.1276","article-title":"A Bioengineereed Implant for a Predetermined Bone Cellular Response to Loading Forces. A Literature Review and Case Report","volume":"72","author":"Misch","year":"2001","journal-title":"J. Periodontol."},{"key":"ref_52","unstructured":"Gunderson, L.L., and Tepper, J.E. (2016). Oral cavity. Clinical Radiation Oncology, Elsevier."},{"key":"ref_53","unstructured":"Payvand, K., and Sadiq, N.M. (2022, November 18). Anatomy, Head and Neck, Oral Cavity (Mouth) Blood Supply and Lymphatics, Available online: https:\/\/pubmed.ncbi.nlm.nih.gov\/31424855\/."},{"key":"ref_54","doi-asserted-by":"crossref","unstructured":"Baranova, J., B\u00fcchner, D., G\u00f6tz, W., Schulze, M., and Tobiasch, E. (2020). Tooth formation: Are the hardest tissues of human body hard to regenerate?. Int. J. Mol. Sci., 21.","DOI":"10.3390\/ijms21114031"},{"key":"ref_55","first-page":"711","article-title":"Dentin: Strucutre, composition and mineralization","volume":"3","author":"Goldberg","year":"2011","journal-title":"Natl. Institue Heal."},{"key":"ref_56","doi-asserted-by":"crossref","first-page":"589","DOI":"10.1016\/S0300-5712(00)00043-9","article-title":"The hardness and modulus of elasticity of primary molar teeth: An ultra-micro-indentation study","volume":"28","author":"Mahoney","year":"2000","journal-title":"J. Dent."},{"key":"ref_57","doi-asserted-by":"crossref","first-page":"173","DOI":"10.1016\/S0003-9969(00)00089-3","article-title":"Mechanical properties of human dental enamel on the nanometre scale","volume":"46","author":"Habelitz","year":"2001","journal-title":"Arch. Oral Biol."},{"key":"ref_58","doi-asserted-by":"crossref","first-page":"1403","DOI":"10.1016\/j.dental.2009.06.014","article-title":"Determination of the elastic\/plastic transition of human enamel by nanoindentation","volume":"25","author":"Ang","year":"2009","journal-title":"Dent. Mater."},{"key":"ref_59","doi-asserted-by":"crossref","first-page":"515","DOI":"10.1016\/j.jmbbm.2010.12.002","article-title":"Bin Human enamel rod presents anisotropic nanotribological properties","volume":"4","author":"Jeng","year":"2011","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"ref_60","doi-asserted-by":"crossref","first-page":"281","DOI":"10.1016\/S0003-9969(02)00006-7","article-title":"Nanoindentation mapping of the mechanical properties of human molar tooth enamel","volume":"47","author":"Cuy","year":"2002","journal-title":"Arch. Oral Biol."},{"key":"ref_61","doi-asserted-by":"crossref","first-page":"1811","DOI":"10.1007\/s10856-010-4052-2","article-title":"The mechanical anisotropy on a longitudinal section of human enamel studied by nanoindentation","volume":"21","author":"Cheng","year":"2010","journal-title":"J. Mater. Sci. Mater. Med."},{"key":"ref_62","doi-asserted-by":"crossref","first-page":"856","DOI":"10.1016\/j.archoralbio.2007.03.005","article-title":"The effect of prism orientation on the indentation testing of human molar enamel","volume":"52","author":"Braly","year":"2007","journal-title":"Arch. Oral Biol."},{"key":"ref_63","doi-asserted-by":"crossref","first-page":"747","DOI":"10.1016\/j.matchar.2007.06.008","article-title":"Mechanical and tribological characterization of human tooth","volume":"59","author":"Roy","year":"2008","journal-title":"Mater. Charact."},{"key":"ref_64","first-page":"12","article-title":"The Perception of Food Texture\u2014The Philosophy Of The Breakdown Path","volume":"1","year":"1988","journal-title":"J. Texture Stud."},{"key":"ref_65","doi-asserted-by":"crossref","first-page":"110","DOI":"10.1016\/j.cofs.2015.06.011","article-title":"Physics of food structure breakdown and bolus formation during oral processing of hard and soft solids","volume":"3","author":"Witt","year":"2015","journal-title":"Curr. Opin. Food Sci."},{"key":"ref_66","doi-asserted-by":"crossref","first-page":"277","DOI":"10.1007\/s11249-007-9232-y","article-title":"The lubricating properties of human whole saliva","volume":"27","author":"Bongaerts","year":"2007","journal-title":"Tribol. Lett."},{"key":"ref_67","doi-asserted-by":"crossref","unstructured":"Wang, G., Li, Y., Wang, S., Yang, X., and Sun, Y. (2019). Two-Body and Three-Body Wear Behavior of a Dental Fluorapatite Glass-Ceramic. Coatings, 9.","DOI":"10.3390\/coatings9090580"},{"key":"ref_68","doi-asserted-by":"crossref","first-page":"1662","DOI":"10.1002\/jbm.b.32735","article-title":"Influence of pH on the tribocorrosion behavior of CpTi in the oral environment: Synergistic interactions of wear and corrosion","volume":"100 B","author":"Mathew","year":"2012","journal-title":"J. Biomed. Mater. Res.\u2014Part B Appl. Biomater."},{"key":"ref_69","doi-asserted-by":"crossref","first-page":"980","DOI":"10.1016\/S0043-1648(01)00835-3","article-title":"Wear behavior of human teeth in dry and artificial saliva conditions","volume":"249","author":"Li","year":"2001","journal-title":"Wear"},{"key":"ref_70","doi-asserted-by":"crossref","first-page":"82","DOI":"10.1016\/j.wear.2012.05.030","article-title":"Simultaneous degradation by corrosion and wear of titanium in artificial saliva containing fluorides","volume":"292\u2013293","author":"Souza","year":"2012","journal-title":"Wear"},{"key":"ref_71","doi-asserted-by":"crossref","first-page":"2599","DOI":"10.1016\/j.jeurceramsoc.2012.03.021","article-title":"Friction and wear behaviors of dental ceramics against natural tooth enamel","volume":"32","author":"Wang","year":"2012","journal-title":"J. Eur. Ceram. Soc."},{"key":"ref_72","doi-asserted-by":"crossref","first-page":"S96","DOI":"10.4103\/0975-7406.192032","article-title":"Corrosion resistance of stainless steel, nickel-titanium, titanium molybdenum alloy, and ion-implanted titanium molybdenum alloy archwires in acidic fluoride-containing artificial saliva: An in vitro study","volume":"8","author":"Pulikkottil","year":"2016","journal-title":"J. Pharm. Bioallied Sci."},{"key":"ref_73","doi-asserted-by":"crossref","first-page":"346","DOI":"10.1016\/j.msec.2015.10.031","article-title":"Electrochemical comparison and biological performance of a new CoCrNbMoZr alloy with commercial CoCrMo alloy","volume":"59","author":"Andrei","year":"2016","journal-title":"Mater. Sci. Eng. C"},{"key":"ref_74","doi-asserted-by":"crossref","first-page":"458","DOI":"10.1016\/j.msec.2016.01.079","article-title":"Effect of anodization on the surface characteristics and electrochemical behaviour of zirconium in artificial saliva","volume":"62","author":"Romonti","year":"2016","journal-title":"Mater. Sci. Eng. C"},{"key":"ref_75","doi-asserted-by":"crossref","first-page":"137","DOI":"10.1016\/j.jmbbm.2013.01.019","article-title":"Influence of the fabrication process and fluoride content on the tribocorrosion behaviour of Ti6Al4V biomedical alloy in artificial saliva","volume":"20","author":"Licausi","year":"2013","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"ref_76","unstructured":"Moreira, V., Serro, A.P., Cola\u00e7o, R., Pina, C., Reis, J.A., and Art, E.X.P. (2021, September 27). Tribological Behavior of the Zirconia\/Ti6Al4V System Used in Dental Implants. Available online: https:\/\/www.semanticscholar.org\/paper\/Tribological-behavior-of-the-Zirconia-%2F-Ti-6-Al-4-V-Moreira-Serro\/a28243cc871504ac4abe06f4024bf54e5e482029."},{"key":"ref_77","doi-asserted-by":"crossref","first-page":"1511","DOI":"10.1016\/j.jdent.2015.10.001","article-title":"Long-term sorption and solubility of bulk-fill and conventional resin-composites in water and artificial saliva","volume":"43","author":"Alshali","year":"2015","journal-title":"J. Dent."},{"key":"ref_78","doi-asserted-by":"crossref","first-page":"104","DOI":"10.1051\/odfen\/2011404","article-title":"Understanding dental wear","volume":"15","author":"Saulue","year":"2012","journal-title":"J. Dentofac. Anom. Orthod."},{"key":"ref_79","doi-asserted-by":"crossref","first-page":"660","DOI":"10.1177\/00220345870660S109","article-title":"The Rheology of Saliva","volume":"66","author":"Schwarz","year":"1987","journal-title":"J. Dent. Res."},{"key":"ref_80","first-page":"141","article-title":"Viscoelasticity of human whole saliva collected after acid and mechanical stimulation","volume":"44","author":"Stokes","year":"2007","journal-title":"Biorheology"},{"key":"ref_81","doi-asserted-by":"crossref","unstructured":"Murray, P. (2017). Biocompatibility of Biomaterials for Dental Tissue Repair. Biocompat. Dent. Biomater., 41\u201362.","DOI":"10.1016\/B978-0-08-100884-3.00004-7"},{"key":"ref_82","doi-asserted-by":"crossref","unstructured":"Zafar, M.S., Ullah, R., Qamar, Z., Fareed, M.A., Amin, F., Khurshid, Z., and Sefat, F. (2019). Properties of dental biomaterials. Adv. Dent. Biomater., 7\u201335.","DOI":"10.1016\/B978-0-08-102476-8.00002-5"},{"key":"ref_83","doi-asserted-by":"crossref","first-page":"107799","DOI":"10.1016\/j.triboint.2022.107799","article-title":"Comparative toothbrush abrasion resistance and surface analysis of different dental restorative materials","volume":"175","author":"Pinto","year":"2022","journal-title":"Tribol. Int."},{"key":"ref_84","doi-asserted-by":"crossref","unstructured":"Ruse, N.D. (2008). Fracture mechanics characterization of dental biomaterials. Dent. Biomater. Imaging Test. Model., 261\u2013293.","DOI":"10.1533\/9781845694241.261"},{"key":"ref_85","doi-asserted-by":"crossref","first-page":"1256","DOI":"10.1016\/j.wear.2005.08.010","article-title":"On evaluation of wear resistance of tooth enamel and dental materials","volume":"260","author":"Sajewicz","year":"2006","journal-title":"Wear"},{"key":"ref_86","doi-asserted-by":"crossref","first-page":"2749","DOI":"10.3390\/ma8052749","article-title":"Wear characteristics of metallic biomaterials: A review","volume":"8","author":"Hussein","year":"2015","journal-title":"Materials"},{"key":"ref_87","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1016\/0300-5712(95)00043-7","article-title":"Wear: Mechanisms, manifestations and measurement. Report of a workshop","volume":"24","author":"Mair","year":"1996","journal-title":"J. Dent."},{"key":"ref_88","doi-asserted-by":"crossref","first-page":"959","DOI":"10.1108\/RPJ-09-2018-0256","article-title":"Comparison of wear properties of Ti6Al4V fabricated by wrought and electron beam melting processes in simulated body fluids","volume":"26","author":"Xiang","year":"2020","journal-title":"Rapid Prototyp. J."},{"key":"ref_89","doi-asserted-by":"crossref","first-page":"341","DOI":"10.1016\/S0300-5712(02)00048-9","article-title":"Erosion and attrition of human enamel in vitro Part I: Interaction effects","volume":"30","author":"Eisenburger","year":"2002","journal-title":"J. Dent."},{"key":"ref_90","doi-asserted-by":"crossref","first-page":"703","DOI":"10.1016\/j.jdent.2008.05.001","article-title":"Influence of artificial saliva on abrasive wear and microhardness of dental composites filled with nanoparticles","volume":"36","author":"Mayworm","year":"2008","journal-title":"J. Dent."},{"key":"ref_91","doi-asserted-by":"crossref","first-page":"347","DOI":"10.1016\/j.jmbbm.2010.01.006","article-title":"On the wear mechanism of human dental enamel","volume":"3","author":"Arsecularatne","year":"2010","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"ref_92","doi-asserted-by":"crossref","first-page":"77","DOI":"10.1016\/j.jmbbm.2018.01.024","article-title":"Role of particulate concentration in tooth wear","volume":"80","author":"Constantino","year":"2018","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"ref_93","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1016\/0043-1648(88)90236-0","article-title":"Zum Modelling of two-body abrasive wear","volume":"124","author":"Gahr","year":"1988","journal-title":"Wear"},{"key":"ref_94","doi-asserted-by":"crossref","first-page":"465","DOI":"10.1034\/j.1600-0501.2000.011005465.x","article-title":"Magnitude and distribution of occlusal forces on oral implants supporting fixed prostheses: An in vivo study","volume":"11","author":"Duyck","year":"2000","journal-title":"Clin. Oral Implant. Res."},{"key":"ref_95","doi-asserted-by":"crossref","first-page":"1546","DOI":"10.1177\/00220345940730091001","article-title":"A Two-body Frictional Wear Test","volume":"73","author":"Wassell","year":"1994","journal-title":"J. Dent. Res."},{"key":"ref_96","first-page":"256","article-title":"Wear resistance of composites: A solved problem?","volume":"46","author":"Richards","year":"1998","journal-title":"Gen. Dent."},{"key":"ref_97","doi-asserted-by":"crossref","first-page":"14","DOI":"10.1016\/S0022-3913(96)90412-6","article-title":"An in vitro investigation of the wear of enamel on porcelain and gold in saliva","volume":"75","author":"Hacker","year":"1996","journal-title":"J. Prosthet. Dent."},{"key":"ref_98","doi-asserted-by":"crossref","first-page":"472","DOI":"10.1177\/00220345980770030601","article-title":"Indentation damage and mechanical properties of human enamel and dentin","volume":"77","author":"Xu","year":"1998","journal-title":"J. Dent. Res."},{"key":"ref_99","doi-asserted-by":"crossref","first-page":"565","DOI":"10.1016\/j.cden.2010.03.003","article-title":"Assessment and management of dental erosion","volume":"54","author":"Wang","year":"2010","journal-title":"Dent. Clin. N. Am."},{"key":"ref_100","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1159\/000093344","article-title":"Definition of erosion and links to tooth wear","volume":"20","author":"Ganss","year":"2006","journal-title":"Monogr. Oral Sci."},{"key":"ref_101","unstructured":"Burtscher, D., and Dalla Torre, D. (2021). Dental implant procedures in immunosuppressed organ transplant patients: A systematic review. Int. J. Oral Maxillofac. Surg., 4\u201311."},{"key":"ref_102","doi-asserted-by":"crossref","unstructured":"Misch, C.E. (1999). Contemporary Implant Dentistry, Mosby. [2nd ed.].","DOI":"10.1097\/00008505-199901000-00012"},{"key":"ref_103","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1902\/annals.2000.5.1.22","article-title":"Implant survival to 36 months as related to length and diameter","volume":"5","author":"Winkler","year":"2000","journal-title":"Ann. Periodontol."},{"key":"ref_104","first-page":"173","article-title":"Influence of variations in implant diameters: A 3- to 5-year retrospective clinical report","volume":"14","author":"Ivanoff","year":"1999","journal-title":"Int. Oral Maxillofac Implant."},{"key":"ref_105","doi-asserted-by":"crossref","first-page":"s0278","DOI":"10.1016\/S0278-2391(99)90437-8","article-title":"Mechanical properties of trabecular bone in the human mandible: Implications for dental implant treatment planning and surgical placement","volume":"57","author":"Misch","year":"1999","journal-title":"Int. J. Oral Maxillofac Surg."},{"key":"ref_106","doi-asserted-by":"crossref","first-page":"252","DOI":"10.1097\/00008505-200009030-00011","article-title":"Preliminary evaluation of a new dental implant design in canine models","volume":"9","author":"Bumgardner","year":"2000","journal-title":"Implant Dent."},{"key":"ref_107","doi-asserted-by":"crossref","first-page":"373","DOI":"10.1563\/aaid-joi-D-16-00015","article-title":"A new look at the blade implant","volume":"42","author":"Linkow","year":"2016","journal-title":"J. Oral Implantol."},{"key":"ref_108","unstructured":"Carr, A., and Brown, D. (2016). McCracken\u2019s Removable Partial Prosthodontics, Elsevier. [13th ed.]."},{"key":"ref_109","doi-asserted-by":"crossref","unstructured":"American Dental Association, and Turner, H.F. (1990). Ramus frame implant technique. J. Am. Dent. Assoc., 121, 418\u2013420.","DOI":"10.14219\/jada.archive.1990.0164"},{"key":"ref_110","unstructured":"Dmd, K.U. (2013). Effects of Chemical and Prophylactic Agents Used in Dentistry on Titanium Implant Surfaces. [Ph.D. Thesis, University of Szeged]."},{"key":"ref_111","doi-asserted-by":"crossref","unstructured":"Misch, C.E. (2015). Single-Tooth Implant Restoration: Maxillary Anterior and Posterior Regions. Dent. Implant. Prosthet., 499\u2013552.","DOI":"10.1016\/B978-0-323-07845-0.00029-4"},{"key":"ref_112","doi-asserted-by":"crossref","first-page":"12","DOI":"10.4103\/2229-5194.120516","article-title":"Questionable abutments: General considerations, changing trends in treatment planning and available options","volume":"3","author":"Prasad","year":"2013","journal-title":"J. Interdiscip. Dent."},{"key":"ref_113","doi-asserted-by":"crossref","unstructured":"Rathi, S., and Verma, A. (2018). Material Selection for Single-Tooth Crown Restorations, Elsevier.","DOI":"10.1016\/B978-0-12-813742-0.00014-6"},{"key":"ref_114","doi-asserted-by":"crossref","first-page":"40","DOI":"10.1016\/j.jdent.2016.09.010","article-title":"Dentist Material Selection for Single-Unit Crowns: Findings from The National Dental Practice-Based Research Network","volume":"55","author":"Makhija","year":"2017","journal-title":"J. Dent."},{"key":"ref_115","doi-asserted-by":"crossref","first-page":"300","DOI":"10.1034\/j.1600-0536.2003.00118.x","article-title":"Release of nickel ions from stainless steel alloys used in dental braces and their patch test reactivity in nickel-sensitive individuals","volume":"48","author":"Jensen","year":"2003","journal-title":"Contact Dermat."},{"key":"ref_116","doi-asserted-by":"crossref","first-page":"560","DOI":"10.1016\/j.prosdent.2017.04.021","article-title":"Patient satisfaction with laser-sintered removable partial dentures: A crossover pilot clinical trial","volume":"119","author":"Almufleh","year":"2018","journal-title":"J. Prosthet. Dent."},{"key":"ref_117","doi-asserted-by":"crossref","unstructured":"Weiss, C.M., and Weiss, A. (2001). Implant dentistry nomenclature, classification, and examples. Principles and Practice of Implant Dentistry, Mosby Incorporated.","DOI":"10.1016\/B0-323-00767-8\/50007-5"},{"key":"ref_118","unstructured":"Smith, Y. (2021, November 11). Procedure for Dental Crowns. Available online: https:\/\/www.news-medical.net\/health\/Procedure-for-Dental-Crowns.aspx."},{"key":"ref_119","unstructured":"Smith, Y. (2021, July 24). Types of Dental Braces. Available online: https:\/\/www.news-medical.net\/health\/Types-of-Dental-Braces.aspx."},{"key":"ref_120","first-page":"106","article-title":"Dental implants: Materials and design considerations","volume":"6","author":"Smith","year":"1993","journal-title":"Int. J. Prosthodont."},{"key":"ref_121","first-page":"1","article-title":"Methodology Used in the Study","volume":"7","author":"Poojar","year":"2017","journal-title":"Asian J. Pharm. Clin. Res."},{"key":"ref_122","doi-asserted-by":"crossref","first-page":"6","DOI":"10.1016\/S0022-3913(07)60032-8","article-title":"A clinical evaluation of cobalt-chromium metal-ceramic fixed partial dentures and crowns: A three- to seven-year retrospective study","volume":"98","author":"Eliasson","year":"2007","journal-title":"J. Prosthet. Dent."},{"key":"ref_123","first-page":"31","article-title":"A systematic review on the accuracy of manufacturing techniques for cobalt chromium fixed dental prostheses","volume":"7","author":"Svanborg","year":"2020","journal-title":"Biomater. Investig. Dent."},{"key":"ref_124","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.jds.2014.07.002","article-title":"Orthodontic wires and its corrosion\u2014The specific case of stainless steel and beta-titanium","volume":"10","author":"Castro","year":"2015","journal-title":"J. Dent. Sci."},{"key":"ref_125","doi-asserted-by":"crossref","first-page":"372","DOI":"10.1016\/j.jobcr.2019.10.001","article-title":"Effect of different abutment materials (zirconia or titanium) on the crestal bone height in 1 year: Bone loss with implant abutment materials","volume":"10","author":"Bharate","year":"2020","journal-title":"J. Oral Biol. Craniofacial Res."},{"key":"ref_126","doi-asserted-by":"crossref","first-page":"1112","DOI":"10.1016\/j.dental.2018.04.007","article-title":"In vitro and in vivo studies of anti-bacterial copper-bearing titanium alloy for dental application","volume":"34","author":"Liu","year":"2018","journal-title":"Dent. Mater."},{"key":"ref_127","doi-asserted-by":"crossref","first-page":"304","DOI":"10.1016\/j.jmbbm.2016.01.023","article-title":"Static and fatigue mechanical behavior of three dental CAD\/CAM ceramics","volume":"59","author":"Homaei","year":"2016","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"ref_128","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1016\/S0022-3913(13)60005-0","article-title":"The wear of polished and glazed zirconia against enamel","volume":"109","author":"Janyavula","year":"2013","journal-title":"J. Prosthet. Dent."},{"key":"ref_129","doi-asserted-by":"crossref","unstructured":"Vaicelyte, A., Janssen, C., Le Borgne, M., and Grosgogeat, B. (2020). Cobalt\u2013Chromium Dental Alloys: Metal Exposures, Toxicological Risks, CMR Classification, and EU Regulatory Framework. Crystals, 10.","DOI":"10.3390\/cryst10121151"},{"key":"ref_130","doi-asserted-by":"crossref","first-page":"1657","DOI":"10.1007\/s11665-020-04711-2","article-title":"Corrosion Assessment of an Implantable Dental Co-Cr Alloy in Artificial Saliva and Biocompatibility Behavior","volume":"29","author":"Roncagliolo","year":"2020","journal-title":"J. Mater. Eng. Perform."},{"key":"ref_131","doi-asserted-by":"crossref","first-page":"90","DOI":"10.1111\/j.1600-0722.2005.00190.x","article-title":"Corrosion resistance of cobalt-chromium and palladium-silver alloys used in fixed prosthetic restorations","volume":"113","author":"Viennot","year":"2005","journal-title":"Eur. J. Oral Sci."},{"key":"ref_132","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1016\/0142-9612(86)90084-0","article-title":"The in vitro toxicity of cobalt-chrome-molybdenum alloy and its constituent metals","volume":"7","author":"Evans","year":"1986","journal-title":"Biomaterials"},{"key":"ref_133","doi-asserted-by":"crossref","first-page":"341","DOI":"10.1111\/j.1600-0714.1988.tb01547.x","article-title":"Reaction of fibroblasts to various dental casting alloys","volume":"17","author":"Craig","year":"1988","journal-title":"J. Oral Pathol. Med."},{"key":"ref_134","first-page":"1","article-title":"The electrochemical behaviour of various non-precious Ni and Co based alloys in artificial saliva","volume":"10","author":"Mareci","year":"2005","journal-title":"Eur. Cells Mater."},{"key":"ref_135","doi-asserted-by":"crossref","unstructured":"Wennerberg, A., Albrektsson, T., and Jimbo, R. (2015). Implant Surfaces and Their Biological and Clinical Impact, Springer. [1st ed.].","DOI":"10.1007\/978-3-662-45379-7"},{"key":"ref_136","doi-asserted-by":"crossref","unstructured":"Fu, W., Liu, S., Jiao, J., Xie, Z., Huang, X., Lu, Y., Liu, H., Hu, S., Zuo, E., and Kou, N. (2022). Wear Resistance and Biocompatibility of Co-Cr Dental Alloys Fabricated with CAST and SLM Techniques. Materials, 15.","DOI":"10.3390\/ma15093263"},{"key":"ref_137","doi-asserted-by":"crossref","first-page":"6486","DOI":"10.3390\/ma7096486","article-title":"A comparative analysis of the corrosive effect of artificial saliva of variable pH on DMLS and cast Co-Cr-Mo dental alloy","volume":"6","author":"Puskar","year":"2014","journal-title":"Materials"},{"key":"ref_138","doi-asserted-by":"crossref","first-page":"435","DOI":"10.1016\/j.msec.2014.04.007","article-title":"Ion release and surface oxide composition of AISI 316L, Co-28Cr-6Mo, and Ti-6Al-4V alloys immersed in human serum albumin solutions","volume":"40","author":"Karimi","year":"2014","journal-title":"Mater. Sci. Eng. C"},{"key":"ref_139","doi-asserted-by":"crossref","first-page":"125610","DOI":"10.1016\/j.surfcoat.2020.125610","article-title":"An investigation on the development and wear performance of chromium-MWCNTs transformed HVOF sprayed nano-WC-CoCr coatings","volume":"388","author":"Thakur","year":"2020","journal-title":"Surf. Coat. Technol."},{"key":"ref_140","doi-asserted-by":"crossref","first-page":"80","DOI":"10.1016\/j.triboint.2014.03.007","article-title":"Tribo-corrosion of steel in artificial saliva","volume":"75","author":"Holmes","year":"2014","journal-title":"Tribol. Int."},{"key":"ref_141","first-page":"111","article-title":"In vitro release of nickel and chromium from different types of simulated orthodontic appliances","volume":"65","author":"Kerosuo","year":"1995","journal-title":"Angle Orthod."},{"key":"ref_142","doi-asserted-by":"crossref","first-page":"855","DOI":"10.1002\/maco.200804173","article-title":"Corrosion aspects of metallic implants\u2014An overview","volume":"59","author":"Balamurugan","year":"2008","journal-title":"Mater. Corros."},{"key":"ref_143","doi-asserted-by":"crossref","first-page":"109097","DOI":"10.1016\/j.corsci.2020.109097","article-title":"The corrosion behavior of Ti6Al4V fabricated by selective laser melting in the artificial saliva with different fluoride concentrations and pH values","volume":"179","author":"Zhang","year":"2021","journal-title":"Corros. Sci."},{"key":"ref_144","doi-asserted-by":"crossref","first-page":"463","DOI":"10.1002\/adem.201500419","article-title":"Selective Laser Melting of Titanium Alloys and Titanium Matrix Composites for Biomedical Applications: A Review","volume":"18","author":"Zhang","year":"2016","journal-title":"Adv. Eng. Mater."},{"key":"ref_145","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.mser.2014.10.001","article-title":"Metallic implant biomaterials","volume":"87","author":"Chen","year":"2015","journal-title":"Mater. Sci. Eng. R Rep."},{"key":"ref_146","doi-asserted-by":"crossref","first-page":"526","DOI":"10.1016\/j.electacta.2014.05.055","article-title":"The effect of fluoride ions on the corrosion behavior of pure titanium in 0.05 M sulfuric acid","volume":"135","author":"Wang","year":"2014","journal-title":"Electrochim. Acta"},{"key":"ref_147","doi-asserted-by":"crossref","first-page":"369","DOI":"10.1016\/j.electacta.2019.04.138","article-title":"Corrosion behavior of Ti-29Nb-13Ta-4.6Zr and commercially pure Ti under simulated inflammatory conditions\u2014Comparative effect of grain refinement and non-toxic \u03b2 phase stabilizers","volume":"312","author":"Sotniczuk","year":"2019","journal-title":"Electrochim. Acta"},{"key":"ref_148","doi-asserted-by":"crossref","first-page":"699","DOI":"10.1016\/j.electacta.2018.03.180","article-title":"Electrochemical surface engineering of titanium-based alloys for biomedical application","volume":"271","author":"Gao","year":"2018","journal-title":"Electrochim. Acta"},{"key":"ref_149","doi-asserted-by":"crossref","first-page":"366","DOI":"10.1016\/j.electacta.2016.01.146","article-title":"Multiscale electrochemical analysis of the corrosion of titanium and nitinol for implant applications","volume":"203","author":"Izquierdo","year":"2016","journal-title":"Electrochim. Acta"},{"key":"ref_150","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1016\/j.biomaterials.2004.02.005","article-title":"Comparison of metal release from various metallic biomaterials in vitro","volume":"26","author":"Okazaki","year":"2005","journal-title":"Biomaterials"},{"key":"ref_151","first-page":"127","article-title":"Toxicity of metals released from implanted medical devices","volume":"1","author":"Brown","year":"2021","journal-title":"Handb. Toxicol. Met. Fifth Ed."},{"key":"ref_152","doi-asserted-by":"crossref","unstructured":"Huang, J., Li, X., and Guo, Z.X. (2019). Biomechanical and biochemical compatibility in innovative biomaterials. Biocompat. Perform. Med. Devices, 23\u201346.","DOI":"10.1016\/B978-0-08-102643-4.00004-5"},{"key":"ref_153","doi-asserted-by":"crossref","unstructured":"Kim, H.R., Jang, S.H., Kim, Y.K., Son, J.S., Min, B.K., Kim, K.H., and Kwon, T.Y. (2016). Microstructures and mechanical properties of Co-Cr dental alloys fabricated by three CAD\/CAM-based processing techniques. Materials, 9.","DOI":"10.3390\/ma9070596"},{"key":"ref_154","doi-asserted-by":"crossref","first-page":"106455","DOI":"10.1016\/j.optlastec.2020.106455","article-title":"Additive manufacturing of stellite 6 superalloy by direct laser metal deposition\u2014Part 2: Effects of scanning pattern and laser power reduction in differrent layers","volume":"131","author":"Moradi","year":"2020","journal-title":"Opt. Laser Technol."},{"key":"ref_155","doi-asserted-by":"crossref","first-page":"276","DOI":"10.1016\/j.msec.2019.04.011","article-title":"Microstructural evolution and resulting properties of differently sintered and heat-treated binder-jet 3D-printed Stellite 6","volume":"102","author":"Mostafaei","year":"2019","journal-title":"Mater. Sci. Eng. C"},{"key":"ref_156","unstructured":"Crook, P., Asphahani, A.I., and Matthews, S.J. (1991). Corrosion-And-Wear-Resistant Cobalt-Base Alloy. (5,002,731), US Patent."},{"key":"ref_157","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1016\/j.matchar.2010.10.011","article-title":"Microstructural characterization of as-cast biocompatible Co-Cr-Mo alloys","volume":"62","author":"Giacchi","year":"2011","journal-title":"Mater. Charact."},{"key":"ref_158","first-page":"68","article-title":"The Chronicle of a Stainless Steel Orthopaedic Implant","volume":"17","author":"Walley","year":"2016","journal-title":"Orthop. J. Harv. Med. Sch."},{"key":"ref_159","doi-asserted-by":"crossref","first-page":"383","DOI":"10.1089\/end.1997.11.383","article-title":"Characteristics of metals used in implants","volume":"11","author":"Gotman","year":"1997","journal-title":"J. Endourol."},{"key":"ref_160","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1111\/j.1600-0536.1997.tb00314.x","article-title":"Nickel release from stainless steels","volume":"37","author":"Haudrechy","year":"1997","journal-title":"Contact Dermat."},{"key":"ref_161","doi-asserted-by":"crossref","unstructured":"Menn\u00e9, T., Brandup, F., Thestrup-Pedersen, K., Veien, N.K., Andersen, J.R., Yding, F., and Valeur, G. (1987). Patch test reactivity to nickel alloys. Contact Dermat., 105\u2013120.","DOI":"10.1111\/j.1600-0536.1987.tb01448.x"},{"key":"ref_162","doi-asserted-by":"crossref","first-page":"156","DOI":"10.1016\/0002-9416(83)90180-X","article-title":"In vitro release of nickel and chromium from simulated orthodontic appliances","volume":"84","author":"Park","year":"1983","journal-title":"Am. J. Orthod."},{"key":"ref_163","doi-asserted-by":"crossref","first-page":"409","DOI":"10.3109\/00016358709096365","article-title":"Metal release from heat-treated orthodontic archwires","volume":"45","author":"Gjerdet","year":"1987","journal-title":"Acta Odontol. Scand."},{"key":"ref_164","first-page":"65","article-title":"Alloys: Titanium","volume":"1","author":"Bieler","year":"2005","journal-title":"Ref. Modul. Mater. Sci. Mater. Eng."},{"key":"ref_165","doi-asserted-by":"crossref","first-page":"1525","DOI":"10.1016\/j.dental.2008.03.029","article-title":"Direct laser metal sintering as a new approach to fabrication of an isoelastic functionally graded material for manufacture of porous titanium dental implants","volume":"24","author":"Traini","year":"2008","journal-title":"Dent. Mater."},{"key":"ref_166","doi-asserted-by":"crossref","first-page":"1247","DOI":"10.1111\/j.1600-0501.2009.01734.x","article-title":"Osseointegration of zirconia and titanium dental implants: A histological and histomorphometrical study in the maxilla of pigs","volume":"20","author":"Gahlert","year":"2009","journal-title":"Clin. Oral Implant. Res."},{"key":"ref_167","doi-asserted-by":"crossref","first-page":"823","DOI":"10.1111\/j.1600-0501.2008.01544.x","article-title":"Titanium allergy in dental implant patients: A clinical study on 1500 consecutive patients","volume":"19","author":"Sicilia","year":"2008","journal-title":"Clin. Oral Implant. Res."},{"key":"ref_168","doi-asserted-by":"crossref","first-page":"591","DOI":"10.1016\/j.cden.2007.03.005","article-title":"Precious Metals in Dentistry","volume":"51","author":"Givan","year":"2007","journal-title":"Dent. Clin. North Am."},{"key":"ref_169","first-page":"1","article-title":"Alternative Processing Techniques for CoCr Dental Alloys","volume":"1\u20133","author":"Reclaru","year":"2019","journal-title":"Encycl. Biomed. Eng."},{"key":"ref_170","unstructured":"Ferracane, J., and Powers, J. (2019). Restorative materials: Resin composites and polymers. Craig\u2019s Restorative Dental Materials, Elsevier. [14th ed.]."},{"key":"ref_171","doi-asserted-by":"crossref","first-page":"149","DOI":"10.1016\/j.procir.2018.08.304","article-title":"Paryanto Application of lost wax casting for manufacturing of orthopedic screw: A review","volume":"78","author":"Aziz","year":"2018","journal-title":"Procedia CIRP"},{"key":"ref_172","doi-asserted-by":"crossref","first-page":"218.e1","DOI":"10.1016\/j.prosdent.2022.05.011","article-title":"Analysis of microstructure and fatigue of cast versus selective laser-melted dental Co-Cr alloy","volume":"128","author":"Wu","year":"2022","journal-title":"J. Prosthet. Dent."},{"key":"ref_173","doi-asserted-by":"crossref","first-page":"617","DOI":"10.1016\/j.prosdent.2017.11.015","article-title":"Comparative analysis of the microstructures and mechanical properties of Co-Cr dental alloys fabricated by different methods","volume":"120","author":"Zhou","year":"2018","journal-title":"J. Prosthet. Dent."},{"key":"ref_174","doi-asserted-by":"crossref","first-page":"346","DOI":"10.20965\/ijat.2019.p0346","article-title":"Review of wire arc additive manufacturing for 3d metal printing","volume":"13","author":"Li","year":"2019","journal-title":"Int. J. Autom. Technol."},{"key":"ref_175","doi-asserted-by":"crossref","first-page":"315","DOI":"10.1080\/09506608.2015.1116649","article-title":"The Metallurgy and Processing Science of Metal","volume":"61","author":"Sames","year":"2016","journal-title":"Int. Mater. Rev."},{"key":"ref_176","doi-asserted-by":"crossref","first-page":"196","DOI":"10.1108\/13552540710776142","article-title":"Selective laser melting of biocompatible metals for rapid manufacturing of medical parts","volume":"13","author":"Vandenbroucke","year":"2007","journal-title":"Rapid Prototyp. J."},{"key":"ref_177","first-page":"87","article-title":"Analysis of defect generation in Ti-6Al-4V parts made using powder bed fusion additive manufacturing processes","volume":"1","author":"Gong","year":"2014","journal-title":"Addit. Manuf."},{"key":"ref_178","doi-asserted-by":"crossref","first-page":"348","DOI":"10.1016\/j.procir.2021.03.121","article-title":"Directed Energy Deposition of stainless steel wire with laser beam: Evaluation of geometry and affection depth","volume":"99","author":"Caiazzo","year":"2021","journal-title":"Procedia CIRP"},{"key":"ref_179","doi-asserted-by":"crossref","unstructured":"Sing, S.L., Tey, C.F., Tan, J.H.K., Huang, S., and Yeong, W.Y. (2019). 3D printing of metals in rapid prototyping of biomaterials: Techniques in additive manufacturing. Rapid Prototyp. Biomater. Tech. Addit. Manuf., 17\u201340.","DOI":"10.1016\/B978-0-08-102663-2.00002-2"},{"key":"ref_180","doi-asserted-by":"crossref","unstructured":"Barro, \u00d3., Arias-Gonz\u00e1lez, F., Lusqui\u00f1os, F., Comesa\u00f1a, R., Del Val, J., Riveiro, A., Badaoui, A., G\u00f3mez-Ba\u00f1o, F., and Pou, J. (2021). Improved commercially pure titanium obtained by laser directed energy deposition for dental prosthetic applications. Metals, 11.","DOI":"10.3390\/met11010070"},{"key":"ref_181","doi-asserted-by":"crossref","first-page":"450","DOI":"10.1016\/j.cirpj.2020.07.007","article-title":"Impact of DED process parameters on the metallurgical characteristics of 17-4 PH SS deposited using DED","volume":"31","author":"Mathoho","year":"2020","journal-title":"CIRP J. Manuf. Sci. Technol."},{"key":"ref_182","doi-asserted-by":"crossref","first-page":"116286","DOI":"10.1016\/j.jmatprotec.2019.116286","article-title":"Rapid prediction of real-time thermal characteristics, solidification parameters and microstructure in laser directed energy deposition (powder-fed additive manufacturing)","volume":"274","author":"Huang","year":"2019","journal-title":"J. Mater. Process. Technol."},{"key":"ref_183","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1016\/j.optlastec.2018.06.042","article-title":"Relation of thermal behavior and microstructure evolution during multi-track laser melting deposition of Ni-based material","volume":"108","author":"Du","year":"2018","journal-title":"Opt. Laser Technol."},{"key":"ref_184","doi-asserted-by":"crossref","first-page":"823","DOI":"10.1016\/0001-6160(86)90056-8","article-title":"Theory of Microstructural Development During Rapid Solidification","volume":"34","author":"Kurz","year":"1986","journal-title":"Acta Metall."},{"key":"ref_185","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1016\/j.ijheatmasstransfer.2016.08.049","article-title":"Numerical simulation of thermal behavior and multicomponent mass transfer in direct laser deposition of Co-base alloy on steel","volume":"104","author":"Gan","year":"2017","journal-title":"Int. J. Heat Mass Transf."},{"key":"ref_186","doi-asserted-by":"crossref","first-page":"291","DOI":"10.1016\/j.jallcom.2016.04.099","article-title":"Influence of cooling rate on the solidification behavior and microstructure of IN738LC superalloy","volume":"680","author":"Kavoosi","year":"2016","journal-title":"J. Alloy. Compd."},{"key":"ref_187","doi-asserted-by":"crossref","unstructured":"Gao, B., Sui, Y., Wang, H., Chunmin, Z., Wei, Z., Wang, R., and Sun, Y. (2019). Effects of Cooling Rate on the Solidification and Microstructure of Nickel-Based Superalloy GTD222. Materials, 12.","DOI":"10.20944\/preprints201905.0084.v1"},{"key":"ref_188","doi-asserted-by":"crossref","first-page":"431","DOI":"10.1016\/j.matpr.2020.10.071","article-title":"A study on the effect of substrate heating and cooling on bead geometry in wire arc additive manufacturing and its correlation with cooling rate","volume":"41","author":"Gudur","year":"2019","journal-title":"Mater. Today Proc."},{"key":"ref_189","doi-asserted-by":"crossref","first-page":"1306","DOI":"10.1007\/s11663-011-9545-y","article-title":"Multiscale modeling of transport phenomena and dendritic growth in laser cladding processes","volume":"42","author":"Tan","year":"2011","journal-title":"Metall. Mater. Trans. B Process Metall. Mater. Process. Sci."},{"key":"ref_190","doi-asserted-by":"crossref","first-page":"1280","DOI":"10.3109\/00016357.2012.757650","article-title":"Fracture strength of porcelain fused to metal crowns made of cast, milled or laser-sintered cobalt-chromium","volume":"71","year":"2013","journal-title":"Acta Odontol. Scand."},{"key":"ref_191","doi-asserted-by":"crossref","first-page":"201","DOI":"10.1515\/afe-2016-0110","article-title":"Comparison of Dental Prostheses Cast and Sintered by SLM from Co-Cr-Mo-W Alloy","volume":"16","author":"Myszka","year":"2016","journal-title":"Arch. Foundry Eng."},{"key":"ref_192","doi-asserted-by":"crossref","first-page":"67","DOI":"10.4047\/jkap.2014.52.2.67","article-title":"Comparison of the mechanical properties and microstructures of fractured surface for Co-Cr alloy fabricated by conventional cast, 3-D printing laser-sintered and CAD\/CAM milled techniques","volume":"52","author":"Choi","year":"2014","journal-title":"J. Korean Acad. Prosthodont."},{"key":"ref_193","doi-asserted-by":"crossref","first-page":"156.e1","DOI":"10.1016\/j.prosdent.2017.12.007","article-title":"Mechanical properties of cobalt-chromium 3-unit fixed dental prostheses fabricated by casting, milling, and additive manufacturing","volume":"120","author":"Nesse","year":"2018","journal-title":"J. Prosthet. Dent."},{"key":"ref_194","doi-asserted-by":"crossref","first-page":"3071","DOI":"10.1007\/s11661-004-0052-5","article-title":"Continuous cooling \u03b2-to-\u03b1 transformation behaviors of extra-pure and commercially pure Ti","volume":"35 A","author":"Oh","year":"2004","journal-title":"Metall. Mater. Trans. A Phys. Metall. Mater. Sci."},{"key":"ref_195","doi-asserted-by":"crossref","unstructured":"Zhao, X., Li, S., Yan, F., Zhang, Z., and Wu, Y. (2019). Microstructure evolution and mechanical properties of AZ80 Mg alloy during annular channel angular extrusion process and heat treatment. Materials, 12.","DOI":"10.3390\/ma12244223"},{"key":"ref_196","doi-asserted-by":"crossref","first-page":"103821","DOI":"10.1016\/j.jmbbm.2020.103821","article-title":"3D metal printing in dentistry: An in vitro biomechanical comparative study of two additive manufacturing technologies for full-arch implant-supported prostheses","volume":"108","author":"Barbin","year":"2020","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"ref_197","doi-asserted-by":"crossref","first-page":"592","DOI":"10.1016\/0022-3913(94)90443-X","article-title":"Tightening characteristics for screwed joints in osseointegrated dental implants","volume":"71","author":"Burguete","year":"1994","journal-title":"J. Prosthet. Dent."},{"key":"ref_198","unstructured":"Duran, K., Mindivan, H., Atapek, \u015e.H., Simov, M., and Dikova, T. (2018, January 25\u201317). Tribological characterization of cast and selective laser melted Co-Cr-Mo alloys under dry and wet conditions. Proceedings of the 19th International Metallurgy and Materials Congress IMMC, Istanbul, Turkey."},{"key":"ref_199","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1016\/j.matpr.2020.08.550","article-title":"Study of the Tribocorrosion occurring at the implant and implant alloy Interface: Dental implant materials","volume":"44","author":"Mehkri","year":"2021","journal-title":"Mater. Today Proc."},{"key":"ref_200","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1016\/j.corsci.2016.02.014","article-title":"Microstructural, electrochemical and tribo-electrochemical characterisation of titanium-copper biomedical alloys","volume":"109","author":"Pina","year":"2016","journal-title":"Corros. Sci."},{"key":"ref_201","doi-asserted-by":"crossref","first-page":"107769","DOI":"10.1016\/j.triboint.2022.107769","article-title":"Susceptibility to tribocorrosion degradation of 304 L stainless steel from dental structures in biological solution","volume":"174","author":"Axente","year":"2022","journal-title":"Tribol. Int."},{"key":"ref_202","doi-asserted-by":"crossref","first-page":"952","DOI":"10.1016\/S1003-6326(21)65552-8","article-title":"Improvement of in vitro corrosion, wear, and mechanical properties of newly developed Ti alloy by thermal treatment for dental applications","volume":"31","author":"Hussein","year":"2021","journal-title":"Trans. Nonferrous Met. Soc. China"}],"container-title":["Materials"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1996-1944\/16\/1\/161\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T01:50:09Z","timestamp":1760147409000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1996-1944\/16\/1\/161"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,12,24]]},"references-count":202,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,1]]}},"alternative-id":["ma16010161"],"URL":"https:\/\/doi.org\/10.3390\/ma16010161","relation":{},"ISSN":["1996-1944"],"issn-type":[{"value":"1996-1944","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,12,24]]}}}