{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,15]],"date-time":"2026-10-15T07:04:44Z","timestamp":1792047884050,"version":"4.4.0"},"reference-count":41,"publisher":"MDPI AG","issue":"12","license":[{"start":{"date-parts":[[2024,6,10]],"date-time":"2024-06-10T00:00:00Z","timestamp":1717977600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Centrum Obslugi Przedsiebiorcy","award":["RPLD.01.02.02-10-0040\/19"],"award-info":[{"award-number":["RPLD.01.02.02-10-0040\/19"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Materials"],"abstract":"<jats:p>This paper reports the results of our study on electrochemical polishing of titanium and a Ti-based alloy using non-aqueous electrolyte. It was shown that electropolishing ensured the removal of surface defects, thereby providing surface smoothing and decreasing surface roughness. The research was conducted using samples made of titanium and Ti6Al4V alloy, as well as implant system elements: implant analog, multiunit, and healing screw. Electropolishing was carried out under a constant voltage (10\u201315 V) with a specified current density. The electrolyte used contained methanol and sulfuric acid. The modified surface was subjected to a thorough analysis regarding its surface morphology, chemical composition, and physicochemical properties. Scanning electron microscope images and profilometer tests of roughness confirmed significantly smoother surfaces after electropolishing. The surface profile analysis of processed samples also yielded satisfactory results, showing less imperfections than before modification. The EDX spectra showed that electropolishing does not have significant influence on the chemical composition of the samples.<\/jats:p>","DOI":"10.3390\/ma17122832","type":"journal-article","created":{"date-parts":[[2024,6,10]],"date-time":"2024-06-10T08:59:06Z","timestamp":1718009946000},"page":"2832","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":9,"title":["Electrochemical Polishing of Ti and Ti6Al4V Alloy in Non-Aqueous Solution of Sulfuric Acid"],"prefix":"10.3390","volume":"17","author":[{"given":"Agata","family":"Ko\u0142kowska","sequence":"first","affiliation":[{"name":"Department of Inorganic Chemistry, Analytical Chemistry, and Electrochemistry, Faculty of Chemistry, Silesian University of Technology, 44-100 Gliwice, Poland"},{"name":"Chemistry Students Research Society, Faculty of Chemistry, Silesian University of Technology, 44-100 Gliwice, Poland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6681-6905","authenticated-orcid":false,"given":"Joanna","family":"Michalska","sequence":"additional","affiliation":[{"name":"Department of Inorganic Chemistry, Analytical Chemistry, and Electrochemistry, Faculty of Chemistry, Silesian University of Technology, 44-100 Gliwice, Poland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9897-5003","authenticated-orcid":false,"given":"Rafa\u0142","family":"Zieli\u0144ski","sequence":"additional","affiliation":[{"name":"Stomatologia na Ksiezym Mlynie, 16D Tymienieckiego, 90-365 Lodz, Poland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2648-5523","authenticated-orcid":false,"given":"Wojciech","family":"Simka","sequence":"additional","affiliation":[{"name":"Department of Inorganic Chemistry, Analytical Chemistry, and Electrochemistry, Faculty of Chemistry, Silesian University of Technology, 44-100 Gliwice, Poland"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2024,6,10]]},"reference":[{"key":"ref_1","unstructured":"Ferracane, J.L. (2001). Materials in Dentistry: Principles and Applications, Lippincott Williams & Wilkins."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"100","DOI":"10.3390\/prosthesis2020011","article-title":"Titanium Alloys for Dental Implants: A Review","volume":"2","author":"Nicholson","year":"2020","journal-title":"Prosthesis"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1186\/s40902-017-0132-2","article-title":"Recent Advances in Dental Implants","volume":"39","author":"Hong","year":"2017","journal-title":"Maxillofac. Plast. Reconstr. Surg."},{"key":"ref_4","doi-asserted-by":"crossref","unstructured":"Okuniewski, W., Walczak, M., and Szala, M. (2024). Effects of Shot Peening and Electropolishing Treatment on the Properties of Additively and Conventionally Manufactured Ti6Al4V Alloy: A Review. Materials, 17.","DOI":"10.20944\/preprints202401.1375.v1"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1155\/2022\/6987353","article-title":"Electropolishing of Additively Manufactured Ti-6Al-4V Surfaces in Nontoxic Electrolyte Solution","volume":"2022","author":"Tsoeunyane","year":"2022","journal-title":"Adv. Mater. Sci. Eng."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1016\/j.afos.2019.01.001","article-title":"Aluminum Toxicity to Bone: A Multisystem Effect?","volume":"5","author":"Klein","year":"2019","journal-title":"Osteoporos. Sarcopenia"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"1060","DOI":"10.1016\/j.jmrt.2018.07.016","article-title":"De Mechanical and Clinical Properties of Titanium and Titanium-Based Alloys (Ti G2, Ti G4 Cold Worked Nanostructured and Ti G5) for Biomedical Applications","volume":"8","author":"Elias","year":"2019","journal-title":"J. Mater. Res. Technol."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"646","DOI":"10.3109\/17453670903487008","article-title":"The Association between Metal Allergy, Total Hip Arthroplasty, and Revision","volume":"80","author":"Thyssen","year":"2009","journal-title":"Acta Orthop."},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Ke, X., Wu, W., Wang, C., Yu, Y., Zhong, B., Wang, Z., Wang, T., Fu, J., and Guo, J. (2022). Material Removal and Surface Integrity Analysis of Ti6Al4V Alloy after Polishing by Flexible Tools with Different Rigidity. Materials, 15.","DOI":"10.3390\/ma15051642"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"367","DOI":"10.1007\/s10800-019-01390-3","article-title":"Investigation of Electrochemical Properties of Electropolishing Co\u2013Cr Dental Alloy","volume":"50","author":"Han","year":"2020","journal-title":"J. Appl. Electrochem."},{"key":"ref_11","first-page":"1","article-title":"Microbial Corrosion in Titanium-Based Dental Implants: How Tiny Bacteria Can Create a Big Problem?","volume":"7","author":"Costa","year":"2021","journal-title":"J. Bio Tribo Corros."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"117599","DOI":"10.1016\/j.jmatprotec.2022.117599","article-title":"Mechanism Study of Electropolishing from the Perspective of Etching Isotropy","volume":"305","author":"Yi","year":"2022","journal-title":"J. Mater. Process. Technol."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"4269","DOI":"10.1007\/s00170-023-11400-6","article-title":"Green Electrochemical Polishing of EBM Ti6Al4V Samples with Preliminary Fatigue Results","volume":"126","author":"Acquesta","year":"2023","journal-title":"Int. J. Adv. Manuf. Technol."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"2437","DOI":"10.1016\/j.electacta.2009.11.097","article-title":"Electropolishing and Passivation of NiTi Shape Memory Alloy","volume":"55","author":"Simka","year":"2010","journal-title":"Electrochim. Acta"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"043510","DOI":"10.1149\/1945-7111\/ac6450","article-title":"Review\u2014Electropolishing of Additive Manufactured Metal Parts","volume":"169","author":"Chaghazardi","year":"2022","journal-title":"J. Electrochem. Soc."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"190","DOI":"10.1016\/j.matchar.2005.04.008","article-title":"Use of Electropolishing for Enhanced Metallic Specimen Preparation for Electron Backscatter Diffraction Analysis","volume":"55","author":"Wynick","year":"2005","journal-title":"Mater. Charact."},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Poznyak, A., Kn\u00f6rnschild, G., Hoha, A., and Pligovka, A. (2024). Porous and Ag-, Cu-, Zn-Doped Al2O3 Fabricated via Barrier Anodizing of Pure Al and Alloys. Coatings, 14.","DOI":"10.3390\/coatings14050576"},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Poznyak, A., Pligovka, A., Turavets, U., and Norek, M. (2020). On-Aluminum and Barrier Anodic Oxide: Meeting the Challenges of Chemical Dissolution Rate in Various Acids and Solutions. Coatings, 10.","DOI":"10.3390\/coatings10090875"},{"key":"ref_19","unstructured":"Yang, L., Lassell, A., and Paiva, G.P.V. (2020, January 10\u201312). Further Study of the Electropolishing of Ti6Al4V Parts Made via Electron Beam Melting. Proceedings of the 26th Annual International Solid Freeform Fabrication Symposium\u2014An Additive Manufacturing Conference SFF 2015, Austin, TX, USA."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"258","DOI":"10.4012\/dmj.27.258","article-title":"Electropolishing of CP Titanium and Its Alloys in an Alcoholic Solution-Based Electrolyte","volume":"27","author":"Tajima","year":"2008","journal-title":"Dent. Mater. J."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"2100545","DOI":"10.1002\/adem.202100545","article-title":"The Electropolishing of Additively Manufactured Parts in Titanium: State of the Art","volume":"23","author":"Acquesta","year":"2021","journal-title":"Adv. Eng. Mater."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"80","DOI":"10.1016\/S0026-0576(04)82510-8","article-title":"The Electropolishing of Titanium and Its Alloys","volume":"102","author":"Kuhn","year":"2004","journal-title":"Met. Finish."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1155\/2016\/1750105","article-title":"Electropolished Titanium Implants with a Mirror-Like Surface Support Osseointegration and Bone Remodelling","volume":"2016","author":"Shah","year":"2016","journal-title":"Adv. Mater. Sci. Eng."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"1044","DOI":"10.1149\/1.2131618","article-title":"Electropolishing of Titanium in Perchloric Acid-Acetic Acid Solution: II. Polarization Behavior and Stoichiometry","volume":"125","author":"Mathieu","year":"1978","journal-title":"J. Electrochem. Soc."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"132","DOI":"10.1179\/0020296713Z.000000000135","article-title":"Electropolishing Behaviour of Pure Titanium in Perchloric Acid-Methanol-Ethylene Glycol Mixed Solution","volume":"92","author":"Peighambardoust","year":"2014","journal-title":"Trans. Inst. Met. Finish."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"2362","DOI":"10.1149\/1.1838644","article-title":"The Mechanism of Electropolishing of Titanium in Methanol-Sulfuric Acid Electrolytes","volume":"145","author":"Piotrowski","year":"1998","journal-title":"J. Electrochem. Soc."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"494","DOI":"10.1016\/j.corsci.2015.05.057","article-title":"Effect of Added Ethanol in Ethylene Glycol-NaCl Electrolyte on Titanium Electropolishing","volume":"98","author":"Kim","year":"2015","journal-title":"Corros. Sci."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"11060","DOI":"10.1021\/cr300162p","article-title":"Deep Eutectic Solvents (DESs) and Their Applications","volume":"114","author":"Smith","year":"2014","journal-title":"Chem. Rev."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"126125","DOI":"10.1016\/j.colsurfa.2020.126125","article-title":"Enhancement of the Surface Characteristics of Ti-Based Biomedical Alloy by Electropolishing in Environmentally Friendly Deep Eutectic Solvent (Ethaline)","volume":"613","author":"Kityk","year":"2021","journal-title":"Colloids Surf. A Physicochem. Eng. Asp."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"76","DOI":"10.1515\/pjct-2016-0074","article-title":"Improvement of the Stainless Steel Electropolishing Process by Organic Additives","volume":"18","author":"Lochynski","year":"2016","journal-title":"Pol. J. Chem. Technol."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"150","DOI":"10.1016\/j.surfcoat.2018.04.082","article-title":"Electropolishing Valve Metals with a Sulfuric Acid-Methanol Electrolyte at Low Temperature","volume":"347","author":"Barnes","year":"2018","journal-title":"Surf. Coat. Technol."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"D563","DOI":"10.1149\/1.2945913","article-title":"The Mechanism of Electropolishing of Niobium in Hydrofluoric\u2013Sulfuric Acid Electrolyte","volume":"155","author":"Tian","year":"2008","journal-title":"J. Electrochem. Soc."},{"key":"ref_33","doi-asserted-by":"crossref","unstructured":"\u0141yczkowska-Wid\u0142ak, E., Lochy\u0144ski, P., and Nawrat, G. (2020). Electrochemical Polishing of Austenitic Stainless Steels. Materials, 13.","DOI":"10.3390\/ma13112557"},{"key":"ref_34","first-page":"240","article-title":"Metoda Identyfikacji Warstw o R\u00f3\u017cnej Nanotwardo \u015aci Powsta\u0142ych Po Walcowaniu Na Zimno Austenitycznej Stali Stopowej","volume":"15","author":"Rokosz","year":"2014","journal-title":"Autobusy Tech. Eksploat. Syst. Transp."},{"key":"ref_35","doi-asserted-by":"crossref","unstructured":"Maniam, K.K., and Paul, S. (2021). Ionic Liquids and Deep Eutectic Solvents for CO2 Conversion Technologies\u2014A Review. Materials, 14.","DOI":"10.3390\/ma14164519"},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"051504","DOI":"10.1149\/1945-7111\/ad4b60","article-title":"Electropolishing with Low Mass Loss for Additive Manufacturing of Ti6Al4V in Zinc Chloride-Urea Deep-Eutectic Solvent","volume":"171","author":"Tang","year":"2024","journal-title":"J. Electrochem. Soc."},{"key":"ref_37","doi-asserted-by":"crossref","unstructured":"Prihandana, G.S., Sriani, T., Jamaludin, M.F., Yusof, F., Arifvianto, B., and Mahardika, M. (2023). Parameters Optimization for Electropolishing Titanium by Using Taguchi-Based Pareto ANOVA. Metals, 13.","DOI":"10.3390\/met13020392"},{"key":"ref_38","first-page":"203","article-title":"Corrosion Study of Ti6Al7Nb Alloy after Thermal, Anodic and Alkali Surface Treatments","volume":"31","author":"Chrzanowski","year":"2008","journal-title":"J. Achiev. Mater. Manuf. Eng."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"1508","DOI":"10.1016\/j.surfcoat.2008.11.028","article-title":"Corrosion and Surface Characterization of Titanium Biomaterial after Magnetoelectropolishing","volume":"203","author":"Hryniewicz","year":"2009","journal-title":"Surf. Coat. Technol."},{"key":"ref_40","doi-asserted-by":"crossref","unstructured":"Jhong, Y.T., Chao, C.Y., Hung, W.C., and Du, J.K. (2020). Effects of Various Polishing Techniques on the Surface Characteristics of the Ti-6al-4v Alloy and on Bacterial Adhesion. Coatings, 10.","DOI":"10.3390\/coatings10111057"},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"239","DOI":"10.1016\/j.surfcoat.2012.10.055","article-title":"Electrochemical Polishing of Ti-13Nb-13Zr Alloy","volume":"213","author":"Simka","year":"2012","journal-title":"Surf. Coat. Technol."}],"container-title":["Materials"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1996-1944\/17\/12\/2832\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T14:56:29Z","timestamp":1760108189000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1996-1944\/17\/12\/2832"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,6,10]]},"references-count":41,"journal-issue":{"issue":"12","published-online":{"date-parts":[[2024,6]]}},"alternative-id":["ma17122832"],"URL":"https:\/\/doi.org\/10.3390\/ma17122832","relation":{},"ISSN":["1996-1944"],"issn-type":[{"value":"1996-1944","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,6,10]]}}}