{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T21:07:20Z","timestamp":1790802440136,"version":"4.1.0"},"reference-count":73,"publisher":"MDPI AG","issue":"12","license":[{"start":{"date-parts":[[2024,6,15]],"date-time":"2024-06-15T00:00:00Z","timestamp":1718409600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Materials"],"abstract":"<jats:p>Implantoplasty is a technique increasingly used to remove the biofilm that causes peri-implantitis on dental implants. This technique of mechanization of the titanium surface makes it possible to eliminate bacterial colonies, but it can generate variations in the properties of the implant. These variations, especially those in fatigue resistance and electrochemical corrosion behavior, have not been studied much. In this work, fatigue tests were performed on 60 dental implants without implantoplasty, namely 30 in air and 30 in Hank\u2019s solution at 37 \u00b0C, and 60 with implatoplasty, namely 30 in air and 30 in Hank\u2019s solution at 37 \u00b0C, using triaxial tension\u2013compression and torsion stresses simulating human chewing. Mechanical tests were performed with a Bionix servo-hydraulic testing machine and fracture surfaces were studied by scanning electron microcopyElectrochemical corrosion tests were performed on 20 dental implants to determine the corrosion potentials and corrosion intensity for control implants and implantoplasty implants. Studies of titanium ion release to the physiological medium were carried out for each type of dental implants by Inductively Coupled-Plasma Mass Spectrometry at different immersion times at 37 \u00b0C. The results show a loss of fatigue caused by the implantoplasty of 30%, observing that the nucleation points of the cracks are in the areas of high deformation in the areas of the implant neck where the mechanization produced in the treatment of the implantoplasty causes an exaltation of fatigue cracks. It has been observed that tests performed in Hank\u2019s solution reduce the fatigue life due to the incorporation of hydrogen in the titanium causing the formation of hydrides that embrittle the dental implant. Likewise, the implantoplasty causes a reduction of the corrosion resistance with some pitting on the machined surface. Ion release analyses are slightly higher in the implantoplasted samples but do not show statistically significant differences. It has been observed that the physiological environment reduces the fatigue life of the implants due to the penetration of hydrogen into the titanium forming titanium hydrides which embrittle the implant. These results should be taken into account by clinicians to determine the convenience of performing a treatment such as implantoplasty that reduces the mechanical behavior and increases the chemical degradation of the titanium dental implant.<\/jats:p>","DOI":"10.3390\/ma17122944","type":"journal-article","created":{"date-parts":[[2024,6,17]],"date-time":"2024-06-17T06:29:43Z","timestamp":1718605783000},"page":"2944","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":16,"title":["The Effect of Implantoplasty on the Fatigue Behavior and Corrosion Resistance in Titanium Dental Implants"],"prefix":"10.3390","volume":"17","author":[{"given":"Darcio","family":"Fonseca","sequence":"first","affiliation":[{"name":"Bioengineering Institute of Technology, Medicine and Health Sciences Faculty, Universitat Internacional de Catalunya, Josep Trueta s\/n, 08195 Sant Cugat del Vall\u00e8s, Barcelona, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5542-7659","authenticated-orcid":false,"given":"Beatriz","family":"de Tapia","sequence":"additional","affiliation":[{"name":"Department of Periodontology, Faculty of Dentistry, Universitat Internacional de Catalunya, Josep Trueta s\/n, 08195 Sant Cugat del Vall\u00e8s, Barcelona, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ramon","family":"Pons","sequence":"additional","affiliation":[{"name":"Department of Periodontology, Faculty of Dentistry, Universitat Internacional de Catalunya, Josep Trueta s\/n, 08195 Sant Cugat del Vall\u00e8s, Barcelona, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2969-6067","authenticated-orcid":false,"given":"Conrado","family":"Aparicio","sequence":"additional","affiliation":[{"name":"Department of Periodontology, Faculty of Dentistry, Universitat Internacional de Catalunya, Josep Trueta s\/n, 08195 Sant Cugat del Vall\u00e8s, Barcelona, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8780-9379","authenticated-orcid":false,"given":"Fernando","family":"Guerra","sequence":"additional","affiliation":[{"name":"Department Medicina Dentaire, Facultade de Medicina, Universidade de Coimbra, Pal\u00e1cio dos Grilos, Rua da Ilha, 3000-214 Coimbra, Portugal"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ana","family":"Messias","sequence":"additional","affiliation":[{"name":"Department Medicina Dentaire, Facultade de Medicina, Universidade de Coimbra, Pal\u00e1cio dos Grilos, Rua da Ilha, 3000-214 Coimbra, Portugal"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6824-1412","authenticated-orcid":false,"given":"Javier","family":"Gil","sequence":"additional","affiliation":[{"name":"Department Medicina Dentaire, Facultade de Medicina, Universidade de Coimbra, Pal\u00e1cio dos Grilos, Rua da Ilha, 3000-214 Coimbra, Portugal"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2024,6,15]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"246","DOI":"10.1111\/jcpe.12954","article-title":"Peri-implantitis","volume":"45","author":"Schwarz","year":"2018","journal-title":"J. Clin. Periodontol."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"68","DOI":"10.1111\/j.1600-0501.2006.01353.x","article-title":"Effect of material characteristics and\/or surface topography on biofilm development","volume":"17","author":"Teughels","year":"2006","journal-title":"Clin. Oral Implant. Res."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"997","DOI":"10.1111\/j.1600-0501.2008.01589.x","article-title":"Spontaneous progression of peri-implantitis at different types of implants. An experimental study in dogs. I: Clinical and radiographic observations","volume":"19","author":"Albouy","year":"2008","journal-title":"Clin. Oral Implant. Res."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"366","DOI":"10.1111\/j.1600-0501.2008.01645.x","article-title":"Spontaneous progression of ligatured induced peri-implantitis at implants with different surface characteristics. An experimental study in dogs II: Histological observations","volume":"20","author":"Albouy","year":"2009","journal-title":"Clin. Oral Implant. Res."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1111\/j.1600-051X.2010.01631.x","article-title":"Implant surface characteristics influence the outcome of treatment of peri-implantitis: An experimental study in dogs","volume":"38","author":"Albouy","year":"2011","journal-title":"J. Clin. Periodontol."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"214","DOI":"10.1111\/j.1600-051X.2010.01661.x","article-title":"How do implant surface characteristics influence peri-implant disease?","volume":"38","author":"Renvert","year":"2011","journal-title":"J. Clin. Periodontol."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"447","DOI":"10.1111\/clr.13430","article-title":"Re-osseointegration following reconstructive surgical therapy of experimental peri-implantitis. A pre-clinical in vivo study","volume":"30","author":"Almohandes","year":"2019","journal-title":"Clin. Oral Implant. Res."},{"key":"ref_8","doi-asserted-by":"crossref","unstructured":"Azzola, F., Ionescu, A.C., Ottobelli, M., Cavalli, N., Brambilla, E., Corbella, S., and Francetti, L. (2020). Biofilm formation on dental implant surface treated by implantoplasty: An in-situ study. Dent. J., 8.","DOI":"10.3390\/dj8020040"},{"key":"ref_9","first-page":"150","article-title":"Consensus statements and recommended clinical procedures regarding implant survival and complications","volume":"19","author":"Lang","year":"2004","journal-title":"Int. J. Oral Maxillofac. Implants"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"627","DOI":"10.11607\/prd.1549","article-title":"Treatment of peri-implantitis: Surgical therapeutic approaches based on peri-implantitis defects","volume":"33","author":"Roncati","year":"2013","journal-title":"Int. J. Periodontics Restor. Dent."},{"key":"ref_11","first-page":"129","article-title":"Micro-morphometric assessment of titanium plasma-sprayed coating removal using burs for the treatment of peri-implant disease","volume":"11","author":"Rimondini","year":"2000","journal-title":"Clin. Oral Implant. Res."},{"key":"ref_12","first-page":"42","article-title":"Surgical repair of peri-implant defects","volume":"16","author":"Lozada","year":"1990","journal-title":"J. Oral Implantol."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"776","DOI":"10.1111\/clr.12682","article-title":"Surface roughness of dental implants and treatment time using six different implantoplasty procedures","volume":"27","author":"Ramel","year":"2016","journal-title":"Clin. Oral Implant. Res."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1111\/clr.13037","article-title":"Effect of implantoplasty on fracture resistance and surface roughness of standard diameter dental implants","volume":"29","author":"Figueiredo","year":"2018","journal-title":"Clin. Oral Implant. Res."},{"key":"ref_15","doi-asserted-by":"crossref","unstructured":"Toledano-Serrabona, J., Gil, F.J., Camps-Font, O., Valmaseda-Castell\u00f3n, E., Gay-Escoda, C., and S\u00e1nchez-Garc\u00e9s, M.\u00c1. (2021). Physicochemical and Biological Characterization of Ti6Al4V Particles Obtained by Implantoplasty: An In Vitro Study. Part I. Materials, 14.","DOI":"10.3390\/ma14216507"},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"Wu, X., Cai, C., Gil, J., Jantz, E., Al Sakka, Y., Padial-Molina, M., and Su\u00e1rez-L\u00f3pez del Amo, F. (2022). Characteristics of Particles and Debris Released after Implantoplasty: A Comparative Study. Materials, 15.","DOI":"10.3390\/ma15020602"},{"key":"ref_17","unstructured":"Toledano-Serrabona, J., S\u00e1nchez-Garc\u00e9s, M.A., Gay-Escoda, C., Valmaseda-Castellon, E., Camps-Font, O., Verdeguer, P., Molmeneu, M., and Gil, F.J. (2021). Mechanical properties and corrosi\u00f3n behavior of Ti6Al4V particles obtained by Implatoplasty. An in vivo study. Part II. Materials, 14."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1080\/00016357.2021.1945142","article-title":"Implantoplasty-provoking or reducing inflammation?\u2014A systematic scoping review","volume":"80","author":"Beheshti","year":"2022","journal-title":"Acta Odontol. Scand."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1111\/j.1600-0501.2004.01084.x","article-title":"Therapy of peri-implantitis with resective surgery. A 3-year clinical trial on rough screw-shaped oral implants. Part I: Clinical outcome","volume":"16","author":"Romeo","year":"2005","journal-title":"Clin. Oral Implant. Res."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"110","DOI":"10.1002\/JPER.21-0103","article-title":"Resolution of peri-implantitis by means of implantoplasty as adjunct to surgical therapy: A retrospective study","volume":"93","author":"Monje","year":"2022","journal-title":"J. Periodontol."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"e14","DOI":"10.5037\/jomr.2016.7314","article-title":"Surgical Non-Regenerative Treatments for Peri-Implantitis: A Systematic Review","volume":"7","author":"Ramanauskaite","year":"2016","journal-title":"J. Oral Maxillofac. Res."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"1348","DOI":"10.1177\/0022034520944158","article-title":"Lack of Clinical Benefit of Implantoplasty to Improve Implant Survival Rate","volume":"99","author":"Siqueira","year":"2020","journal-title":"J. Dent. Res."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"e65","DOI":"10.11607\/jomi.4399","article-title":"Analysis of implant strength after implantoplasty in three implant-abutment connection designs: An in vitro study","volume":"31","author":"Gehrke","year":"2016","journal-title":"Int. J. Oral Maxillofac. Implants"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"15790","DOI":"10.1038\/s41598-022-20100-2","article-title":"Evaluation of the inflammatory and osteogenic response induced by titanium particles released during implantoplasty of dental implants","volume":"12","author":"Bosch","year":"2022","journal-title":"Sci Rep."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1111\/jre.12479","article-title":"Can degradation products released from dental implants affect peri-implant tissues?","volume":"53","author":"Oliveira","year":"2018","journal-title":"J. Periodontal Res."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"1271","DOI":"10.1016\/j.biomaterials.2004.04.035","article-title":"The role of macrophages in osteolysis of total joint replacement","volume":"26","author":"Ingham","year":"2005","journal-title":"Biomaterials"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"469","DOI":"10.1002\/jemt.10358","article-title":"Applications of environmental scanning electron microscopy (ESEM) in biomaterials field","volume":"61","author":"Manero","year":"2003","journal-title":"Microsc. Res. Tech."},{"key":"ref_28","doi-asserted-by":"crossref","unstructured":"Velasco-Ortega, E., Fos-Parra, I., Cabanillas-Balsera, D., Gil, J., Ortiz-Garcia, I., Giner, M., Bocio-N\u00fa\u00f1ez, J., Montoya-Garc\u00eda, M.J., and Jim\u00e9nez-Guerra, A. (2023). Osteoblastic Cell Behavior and Gene Expression Related to Bone Metabolism on Different Titanium Surfaces. Int. J. Mol. Sci., 24.","DOI":"10.3390\/ijms24043523"},{"key":"ref_29","doi-asserted-by":"crossref","unstructured":"Nicolas-Silvente, A.I., Velasco-Ortega, E., Ortiz-Garcia, I., Monsalve-Guil, L., Gil, J., and Jimenez-Guerra, A. (2020). Influence of the Titanium Implant Surface Treatment on the Surface Roughness and Chemical Composition. Materials, 13.","DOI":"10.3390\/ma13020314"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"416","DOI":"10.1016\/j.jmbbm.2010.03.006","article-title":"Effect of surface treatments on the fatigue life of titanium for biomedical applications","volume":"3","author":"Pazos","year":"2010","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"273","DOI":"10.1111\/j.1708-8208.2012.00468.x","article-title":"Fatigue life of bioactive titanium dental implants treated by means of Grit Blasting and Thermo-Chemical treatment","volume":"16","author":"Gil","year":"2014","journal-title":"Clin. Implant Dent. Relat. Res."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"172","DOI":"10.1111\/j.1708-8208.2012.00477.x","article-title":"Effect of dental implant diameter on fatigue performance. Part I: Mechanical behavior","volume":"16","author":"Rittel","year":"2014","journal-title":"Clin. Implant Dent. Relat. Res."},{"key":"ref_33","first-page":"178","article-title":"Effect of Dental Implant Diameter on Fatigue Performance. Part II: Failure Analysis","volume":"16","author":"Rittel","year":"2012","journal-title":"Clin. Implant Dent. Relat. Res."},{"key":"ref_34","unstructured":"(1992). Standard Practice for Laboratory Immersion Corrosion Testing Metals (Standard No. ASTM G31-90). 1992 Annual Book of ASTM Standards, Vol. 03.02."},{"key":"ref_35","unstructured":"(1992). Potentiodynamic Anodic Polarization Measurements (Standard No. ASTM G5). 1992 Annual Book of ASTM Standards, Vol. 03.02."},{"key":"ref_36","unstructured":"(1992). Standard Practice for Calculation of Corrosion Rates and Related Information from Electrochemical Measurements (Standard No. ASTM G102-89). 1999 Annual Book of ASTM Standards, Vol. 03.02."},{"key":"ref_37","unstructured":"(1992). Standard Test Method for Conducting Cyclic Potentiodynamic Polarization Measurements for Localized Corrosion Susceptibility of Iron\u2013Nickel, or Cobalt-Based Alloys (Standard No. ASTM G61-86). 1992 Annual Book of ASTM Standards, Vol. 03.02."},{"key":"ref_38","unstructured":"(2021). Biological Evaluation of Medical Devices\u2014Part 12: Sample Preparation and Reference Materials (Standard No. ISO 10993-12:2021)."},{"key":"ref_39","first-page":"253","article-title":"New Ti alloys for biomaterials: A study of mechanical and corrosion properties and cytotoxicity","volume":"7","author":"Kim","year":"1997","journal-title":"Bio-Med. Mater."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"396","DOI":"10.1016\/S0109-5641(01)00063-X","article-title":"Biological interactions of dental cast alloys with oral tissues","volume":"18","author":"Schmalz","year":"2002","journal-title":"Dent. Mater."},{"key":"ref_41","doi-asserted-by":"crossref","unstructured":"Brunette, D.M., Tengvall, P., Textor, M., and Thomsen, P. (2001). Titanium in Medicine: Material Science, Surface Science, Engineering, Biological Responses and Medical Applications, Springer.","DOI":"10.1007\/978-3-642-56486-4"},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"206","DOI":"10.1002\/jbm.b.31171","article-title":"In vivo severe corrosion and hydrogen embrittlement of retrieved modular body titanium alloy hip-implants","volume":"88","author":"Rodrigues","year":"2009","journal-title":"J. Biomed. Mater. Res. B Appl. Biomater."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"469","DOI":"10.1563\/aaid-joi-D-16-00088","article-title":"Importance of the roughness and residual stresses of dental implants on fatigue and osseointegration be-havior. In vivo study in rabbits","volume":"42","author":"Ortiz","year":"2016","journal-title":"J. Oral Implantol."},{"key":"ref_44","doi-asserted-by":"crossref","unstructured":"Velasco-Ortega, E., Flichy-Fern\u00e1ndez, A., Punset, M., Jim\u00e9nez-Guerra, A., Manero, J.M., and Gil, J. (2019). Fracture and Fatigue of Titanium Narrow Dental Implants: New Trends in Order to Improve the Mechanical Response. Materials, 12.","DOI":"10.3390\/ma12223728"},{"key":"ref_45","unstructured":"Colling, E.W. (1984). The Physical Metallurgy of Titanium Alloys. American Society for Metals, ASM International."},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"3353","DOI":"10.1016\/S1359-6454(00)00152-X","article-title":"Deformation mechanisms of Ti-6Al-4V alloy with a martensitic microstructure subjected to oligocyclic fatigue","volume":"48","author":"Manero","year":"2014","journal-title":"Acta Materialia."},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"524","DOI":"10.1016\/j.msec.2015.10.051","article-title":"Anhydride-functional silane immobilized onto titanium surfaces induces osteoblast cell differentiation and reduces bacterial adhesion and biofilm formation","volume":"59","author":"Sevilla","year":"2016","journal-title":"Mater. Sci. Eng. C Mater. Biol. Appl."},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1016\/S0142-9612(02)00314-9","article-title":"Corrosion behaviour of commercially pure titanium shot blasted with different materials and sizes of shot blasted with different materials and sizes of shot particles for dental implant applications","volume":"24","author":"Aparicio","year":"2003","journal-title":"Biomaterials"},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"245","DOI":"10.1016\/j.colsurfb.2019.04.048","article-title":"Porous titanium-hydroxyapatite composite coating obtained on titanium by cold gas spray with high bond strength for biomedical applications","volume":"180","author":"Cinca","year":"2019","journal-title":"Colloids Surf. B Biointerfaces"},{"key":"ref_50","doi-asserted-by":"crossref","unstructured":"Pereira, R., Maia, P., Rios-Santos, J.V., Herrero-Climent, M., Rios-Carrasco, B., Aparicio, C., and Gil, J. (2024). Influence of Titanium Surface Residual Stresses on Osteoblastic Response and Bacteria Colonization. Materials, 17.","DOI":"10.3390\/ma17071626"},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"486","DOI":"10.1016\/j.dental.2006.03.003","article-title":"The effect of shot blasting and heat treatment on the fatigue behavior of titanium for dental implant applications","volume":"23","author":"Gil","year":"2007","journal-title":"Dent. Mater."},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"30","DOI":"10.1016\/j.colsurfb.2018.04.050","article-title":"All-in-one trifunctional strategy: A cell adhesive, bacteriostatic and bactericidal coating for titanium implants","volume":"169","author":"Ginebra","year":"2018","journal-title":"Colloids Surf. B Biointerfaces"},{"key":"ref_53","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1016\/j.dental.2023.10.002","article-title":"Hybrid surface implants: Influence of residual stress on mechanical behavior, evaluated by finite element analysis and validation by fatigue tests","volume":"40","author":"Gil","year":"2024","journal-title":"Dent. Mater."},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"621","DOI":"10.1016\/j.jallcom.2005.02.098","article-title":"Hydrogen cracking in titanium-based alloys","volume":"404","author":"Gutelmacher","year":"2005","journal-title":"J. Alloys Compd."},{"key":"ref_55","doi-asserted-by":"crossref","first-page":"245","DOI":"10.1016\/j.biomaterials.2004.02.023","article-title":"The effect of temperature on the nucleation of corrosion pits on titanium in Ringer\u2019s physiological solution","volume":"26","author":"Burstein","year":"2005","journal-title":"Biomaterials"},{"key":"ref_56","doi-asserted-by":"crossref","unstructured":"Delgado-Ruiz, R., and Romanos, G. (2018). Potential Causes of Titanium Particle and Ion Release in Implant Dentistry: A Systematic Review. Int. J. Mol. Sci., 19.","DOI":"10.3390\/ijms19113585"},{"key":"ref_57","doi-asserted-by":"crossref","first-page":"77","DOI":"10.2106\/00004623-196042010-00007","article-title":"The ionization of metal implants in living tissues","volume":"42","author":"Ferguson","year":"1960","journal-title":"J. Bone Jt. Surg."},{"key":"ref_58","doi-asserted-by":"crossref","first-page":"317","DOI":"10.2106\/00004623-196244020-00008","article-title":"Characteristics of trace ion release from embedded metal implants in the rabbit","volume":"44","author":"Ferguson","year":"1962","journal-title":"J. Bone Jt. Surg."},{"key":"ref_59","doi-asserted-by":"crossref","first-page":"555","DOI":"10.1002\/jbm.820070607","article-title":"Changes in nonosseous tissue adjacent to titanium implants","volume":"7","author":"Meachim","year":"1973","journal-title":"J. Biomed. Mater. Res."},{"key":"ref_60","doi-asserted-by":"crossref","first-page":"96","DOI":"10.1007\/s007950070008","article-title":"Investigation of titanium leak to bone tissue surrounding dental titanium implant: Electron microscopic findings and analysis by electron diffraction","volume":"33","author":"Tanaka","year":"2000","journal-title":"Med. Electron. Microsc."},{"key":"ref_61","doi-asserted-by":"crossref","first-page":"729","DOI":"10.11607\/prd.3386","article-title":"Resective Treatment of Peri-implantitis: Clinical and Radiographic Outcomes After 2 Years","volume":"38","author":"Englezos","year":"2018","journal-title":"Int. J. Periodontics Restor. Dent."},{"key":"ref_62","doi-asserted-by":"crossref","first-page":"340","DOI":"10.1111\/jcpe.13070","article-title":"Efficacy of reconstructive surgical therapy at peri-implantitis-related bone defects. A systematic review and meta-analysis","volume":"46","author":"Tomasi","year":"2019","journal-title":"J. Clin. Periodontol."},{"key":"ref_63","doi-asserted-by":"crossref","first-page":"538","DOI":"10.1016\/j.msec.2016.07.020","article-title":"Evaluation of bone loss in antibacterial coated dental implants: An experimental study in dogs","volume":"69","author":"Sevilla","year":"2016","journal-title":"Mater. Sci. Eng. C Mater. Biol. Appl."},{"key":"ref_64","doi-asserted-by":"crossref","first-page":"132","DOI":"10.1111\/clr.12103","article-title":"Combined surgical therapy of advanced peri-implantitis lesions with concomitant soft tissue volume augmentation. A case series","volume":"25","author":"Schwarz","year":"2014","journal-title":"Clin. Oral Implant. Res."},{"key":"ref_65","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1002\/cap.10186","article-title":"Principles of Combined Surgical Therapy for the Management of Peri-Implantitis","volume":"12","author":"Monje","year":"2022","journal-title":"Clin. Adv. Periodontics"},{"key":"ref_66","first-page":"213","article-title":"Strategies for implant surface decontamination in peri-implantitis therapy","volume":"15","author":"Monje","year":"2022","journal-title":"Int. J. Oral Implantol."},{"key":"ref_67","doi-asserted-by":"crossref","first-page":"305","DOI":"10.1111\/j.1600-051X.2008.01276.x","article-title":"Non-surgical treatment of peri-implant mucositis and peri-implantitis: A literature review","volume":"35","author":"Renvert","year":"2008","journal-title":"J. Clin. Periodontol."},{"key":"ref_68","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1186\/s40729-015-0023-1","article-title":"Efficacy of alternative or adjunctive measures to conventional treatment of peri-implant mucositis and peri-implantitis: A systematic review and meta-analysis","volume":"1","author":"Schwarz","year":"2015","journal-title":"Int. J. Implant. Dent."},{"key":"ref_69","doi-asserted-by":"crossref","first-page":"840","DOI":"10.1111\/clr.13757","article-title":"Erythritol airpolishing in the non-surgical treatment of peri-implantitis: A randomized controlled trial","volume":"32","author":"Hentenaar","year":"2021","journal-title":"Clin. Oral Implant. Res."},{"key":"ref_70","doi-asserted-by":"crossref","first-page":"S267","DOI":"10.1002\/JPER.16-0350","article-title":"Peri-implantitis","volume":"89","author":"Schwarz","year":"2018","journal-title":"J. Periodontol."},{"key":"ref_71","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1111\/prd.12280","article-title":"Biofilm as a risk factor in implant treatment","volume":"81","author":"Daubert","year":"2019","journal-title":"Periodontology 2000"},{"key":"ref_72","doi-asserted-by":"crossref","first-page":"283","DOI":"10.1111\/j.1600-051X.2006.00907.x","article-title":"Nine- to fourteen-year follow-up of implant treatment. Part I: Implant loss and associations to various factors","volume":"33","author":"Lindahl","year":"2006","journal-title":"J. Clin. Periodontol."},{"key":"ref_73","doi-asserted-by":"crossref","first-page":"603","DOI":"10.1016\/j.dental.2015.02.011","article-title":"All-ceramic or metal-ceramic tooth-supported fixed dental prostheses (FDPs)? A systematic review of the survival and complication rates. Part I: Single crowns (SCs)","volume":"31","author":"Sailer","year":"2015","journal-title":"Dent. Mater."}],"container-title":["Materials"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1996-1944\/17\/12\/2944\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T14:59:26Z","timestamp":1760108366000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1996-1944\/17\/12\/2944"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,6,15]]},"references-count":73,"journal-issue":{"issue":"12","published-online":{"date-parts":[[2024,6]]}},"alternative-id":["ma17122944"],"URL":"https:\/\/doi.org\/10.3390\/ma17122944","relation":{},"ISSN":["1996-1944"],"issn-type":[{"value":"1996-1944","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,6,15]]}}}