{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,9]],"date-time":"2026-10-09T23:55:11Z","timestamp":1791590111539,"version":"4.3.4"},"reference-count":52,"publisher":"MDPI AG","issue":"13","license":[{"start":{"date-parts":[[2026,7,3]],"date-time":"2026-07-03T00:00:00Z","timestamp":1783036800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Materials"],"abstract":"<jats:p>Background: Tooth-supported fixed dental prostheses (FDPs) remain relevant when implant therapy is limited, but their mechanical behavior depends on material selection, connector design, retainer design, prosthesis configuration, and abutment support. This systematic review assessed how these factors affect fracture behavior and stress transmission in tooth-supported FDPs. Materials and Methods: PubMed\/MEDLINE, Scopus, Web of Science Core Collection, and Dentistry and Oral Sciences Source were searched for English-language studies published from 1 January 2016 to 15 May 2026. Eligible studies were in vitro mechanical, fatigue, fracture-resistance, or finite element analysis (FEA) studies of tooth-supported FDP designs. Clinical studies were screened during eligibility assessment, but no clinical study met the final inclusion criteria for primary synthesis. In vitro components were appraised with the Quality Assessment Tool for In Vitro Studies (QUIN), and FEA components were appraised with the Risk-of-bias Framework for Dental Finite Element Analysis (ROBFEAD). Findings were synthesized narratively by evidence type and biomechanical theme. Results: Twenty-nine studies were included: 11 in vitro-only studies, 14 FEA-only studies, and four combined experimental and computational studies. No eligible clinical study met the final inclusion criteria. Zirconia-based systems were the most frequent focus. Their behavior depended on connector dimensions, connector shape, framework design, span, retainer configuration, loading direction, abutment selection, periodontal support, and bone support. Larger connector dimensions or greater connector height often improved fracture resistance or reduced modeled stress in zirconia models, but connector area alone did not explain performance across all materials and designs. Conservative FDPs were sensitive to retainer geometry, adhesive-interface behavior, connector design, and abutment support. Conclusions: Current evidence is limited to laboratory and computational studies. Tooth-supported FDP biomechanics should be interpreted as a material, design, and support system, not as a material effect alone.<\/jats:p>","DOI":"10.3390\/ma19132844","type":"journal-article","created":{"date-parts":[[2026,7,3]],"date-time":"2026-07-03T09:34:11Z","timestamp":1783071251000},"page":"2844","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Biomechanics of Tooth-Supported Fixed Dental Prostheses: Material Systems, Connector Design, Retainer Design, and Abutment Stress Distribution\u2014A Systematic Review of In Vitro and Finite Element Evidence"],"prefix":"10.3390","volume":"19","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4391-3331","authenticated-orcid":false,"given":"Iuliana","family":"Babiuc","sequence":"first","affiliation":[{"name":"Department of Dental Technology, Faculty of Midwifery and Nursing, Carol Davila University of Medicine and Pharmacy, 050474 Bucharest, Romania"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andi","family":"Dr\u0103gu\u0219","sequence":"additional","affiliation":[{"name":"Department of Dental Technology, Faculty of Midwifery and Nursing, Carol Davila University of Medicine and Pharmacy, 050474 Bucharest, Romania"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8411-3875","authenticated-orcid":false,"given":"Viorel","family":"Perieanu","sequence":"additional","affiliation":[{"name":"Department of Dental Technology, Faculty of Midwifery and Nursing, Carol Davila University of Medicine and Pharmacy, 050474 Bucharest, Romania"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2095-398X","authenticated-orcid":false,"given":"Andrei","family":"Vorovenci","sequence":"additional","affiliation":[{"name":"Doctoral School, Carol Davila University of Medicine and Pharmacy, 050474 Bucharest, Romania"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2643-0458","authenticated-orcid":false,"given":"Andreea","family":"\u0218te\u021biu","sequence":"additional","affiliation":[{"name":"Faculty of Medicine, Lucian Blaga University of Sibiu, 550169 Sibiu, Romania"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0005-1027-3218","authenticated-orcid":false,"given":"M\u0103d\u0103lina","family":"Mali\u021ba","sequence":"additional","affiliation":[{"name":"Department of Dental Technology, Faculty of Midwifery and Nursing, Carol Davila University of Medicine and Pharmacy, 050474 Bucharest, Romania"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mihaela","family":"Gligor","sequence":"additional","affiliation":[{"name":"Faculty of Medicine, Lucian Blaga University of Sibiu, 550169 Sibiu, Romania"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0005-7847-5932","authenticated-orcid":false,"given":"Maria","family":"\u0218te\u021biu","sequence":"additional","affiliation":[{"name":"Faculty of Medicine, Lucian Blaga University of Sibiu, 550169 Sibiu, Romania"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Radu","family":"Costea","sequence":"additional","affiliation":[{"name":"Department of Dental Technology, Faculty of Midwifery and Nursing, Carol Davila University of Medicine and Pharmacy, 050474 Bucharest, Romania"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrei","family":"Burliba\u0219a","sequence":"additional","affiliation":[{"name":"Faculty of Medicine, Carol Davila University of Medicine and Pharmacy, 050474 Bucharest, Romania"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mircea","family":"Popescu","sequence":"additional","affiliation":[{"name":"Doctoral School, Carol Davila University of Medicine and Pharmacy, 050474 Bucharest, Romania"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mihai","family":"Burliba\u0219a","sequence":"additional","affiliation":[{"name":"Department of Dental Technology, Faculty of Midwifery and Nursing, Carol Davila University of Medicine and Pharmacy, 050474 Bucharest, Romania"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2026,7,3]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","unstructured":"Romandini, P., Pjetursson, B., Pitta, J., Balet, A., Ikumi, R., and Sailer, I. (2026). A Systematic Review and Meta-Analysis Evaluating the Survival, the Failure and the Complication Rates of Metal-Ceramic, Veneered and Monolithic All-Ceramic Tooth-Supported Multiple- Unit Fixed Dental Prostheses (Fdps). Int. J. Prosthodont., 1\u201334.","DOI":"10.11607\/ijp.9666"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"603","DOI":"10.1016\/j.dental.2015.02.011","article-title":"All-ceramic or metal-ceramic tooth-supported fixed dental prostheses (FDPs)? A systematic review of the survival and complication rates. Part I: Single crowns (SCs)","volume":"31","author":"Sailer","year":"2015","journal-title":"Dent. Mater."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"266","DOI":"10.1111\/jopr.12555","article-title":"Anterior Cantilever Resin-Bonded Fixed Dental Prostheses: A Review of the Literature","volume":"27","author":"Bilal","year":"2018","journal-title":"J. Prosthodont."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"654","DOI":"10.1111\/j.1600-0501.2004.01119.x","article-title":"A systematic review of the survival and complication rates of fixed partial dentures (FPDs) after an observation period of at least 5 years","volume":"15","author":"Tan","year":"2004","journal-title":"Clin. Oral Implant. Res."},{"key":"ref_5","doi-asserted-by":"crossref","unstructured":"Caministeanu, F., Perieanu, V.S., Popa, A.S., Manolescu, L.S.C., Stetiu, A.A., Costea, R.C., Burlibasa, M., Vorovenci, A., Costea, R.M., and Serbanescu, C.M. (2025). Assessing the Genotoxic Impact of Ni-Cr Alloys in Dental Prosthodontics: A Preliminary Comparative Analysis with and Without Beryllium. Oral, 5.","DOI":"10.3390\/oral5020032"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"170","DOI":"10.1016\/S0022-3913(12)60051-1","article-title":"Survival and complications of zirconia-based fixed dental prostheses: A systematic review","volume":"107","author":"Raigrodski","year":"2012","journal-title":"J. Prosthet. Dent."},{"key":"ref_7","first-page":"54","article-title":"Survival Rates and Complications for Zirconia-Based Fixed Dental Prostheses in a Period up to 10 Years: A Systematic Review","volume":"26","author":"Stefanescu","year":"2018","journal-title":"Eur. J. Prosthodont. Restor. Dent."},{"key":"ref_8","first-page":"96","article-title":"Finite element analysis to compare stress distribution of connector of lithia disilicate-reinforced glass\u2013ceramic and zirconia-based fixed partial denture","volume":"100","author":"Jie","year":"2011","journal-title":"Odontology"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"1421","DOI":"10.1111\/clr.13007","article-title":"A systematic review of the survival and complication rates of resin-bonded fixed dental prostheses after a mean observation period of at least 5 years","volume":"28","author":"Thoma","year":"2017","journal-title":"Clin. Oral Implant. Res."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1016\/j.prosdent.2014.01.005","article-title":"Clinical outcomes of lithium disilicate single crowns and partial fixed dental prostheses: A systematic review","volume":"112","author":"Sascha","year":"2014","journal-title":"J. Prosthet. Dent."},{"key":"ref_11","doi-asserted-by":"crossref","unstructured":"Abdulmohsen, A., and Abdullah, A. (2023). Survival of Complete Coverage Tooth-Retained Fixed Lithium Disilicate Prostheses: A Systematic Review. Medicina, 59.","DOI":"10.3390\/medicina59010095"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1016\/j.jdent.2017.02.006","article-title":"A systematic review of the survival and complication rates of inlay-retained fixed dental prostheses","volume":"59","author":"Junyu","year":"2017","journal-title":"J. Dent."},{"key":"ref_13","doi-asserted-by":"crossref","unstructured":"Zhu, T., Chen, J., Xu, Y., Zhu, Z., Wang, J., Pei, X., Qiao, M., Cheng, B., Li, R., and Wan, Q. (2024). Biomechanical behaviour of tilted abutment after fixed partial denture restoration of CAD\/CAM materials. BMC Oral Health, 24.","DOI":"10.1186\/s12903-024-04890-7"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"535","DOI":"10.1111\/jopr.12678","article-title":"A Systematic Review of the Survival and Complication Rates of All-Ceramic Resin-Bonded Fixed Dental Prostheses","volume":"27","author":"Junyu","year":"2018","journal-title":"J. Prosthodont."},{"key":"ref_15","doi-asserted-by":"crossref","unstructured":"Popescu, M., Mali\u021ba, M., Vorovenci, A., \u0218te\u021biu, A.A., Perieanu, V.\u0218., Costea, R.C., David, M., Costea, R.M., \u0218te\u021biu, M.A., and Dr\u0103gu\u0219, A.C. (2025). Wet vs. Dry Dentin Bonding: A Systematic Review and Meta-Analysis of Adhesive Performance and Hybrid Layer Integrity. Oral, 5.","DOI":"10.3390\/oral5030063"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"788","DOI":"10.1055\/s-0041-1731587","article-title":"Survival Rates of Anterior-Region Resin-Bonded Fixed Dental Prostheses: An Integrative Review","volume":"15","author":"Mendes","year":"2021","journal-title":"Eur. J. Dent."},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Mohd Osman, M.L., Lim, T.W., Chang, H.-C., Ab Ghani, A.R., Tsoi, J.K.H., and Ab Ghani, S.M. (2023). Structural Integrity of Anterior Ceramic Resin-Bonded Fixed Partial Denture: A Finite Element Analysis Study. J. Funct. Biomater., 14.","DOI":"10.3390\/jfb14020108"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"n71","DOI":"10.1136\/bmj.n71","article-title":"The PRISMA 2020 statement: An updated guideline for reporting systematic reviews","volume":"372","author":"Page","year":"2021","journal-title":"BMJ"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"1038","DOI":"10.1016\/j.prosdent.2022.05.019","article-title":"Development and validation of a risk-of-bias tool for assessing in vitro studies conducted in dentistry: The QUIN","volume":"131","author":"Sheth","year":"2024","journal-title":"J. Prosthet. Dent."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"1822","DOI":"10.1080\/10255842.2022.2148465","article-title":"Development and validation of risk of bias tool for the use of finite element analysis in dentistry (ROBFEAD)","volume":"26","author":"Mathur","year":"2023","journal-title":"Comput. Methods Biomech. Biomed. Eng."},{"key":"ref_21","first-page":"e1230","article-title":"PRISMA2020: An R package and Shiny app for producing PRISMA 2020-compliant flow diagrams, with interactivity for optimised digital transparency and Open Synthesis","volume":"18","author":"Haddaway","year":"2022","journal-title":"Campbell Syst. Rev."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"555","DOI":"10.5005\/jp-journals-10024-3896","article-title":"Effect of First Premolar Retainer Design on Tensile Bond Strength in Three-unit Fixed Partial Dentures: An In Vitro Study","volume":"26","author":"Mohsen","year":"2025","journal-title":"J. Contemp. Dent. Pract."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"933.E1","DOI":"10.1016\/j.prosdent.2024.01.033","article-title":"Effect of connector height and retainer occlusal thickness on the fracture resistance of posterior 4-unit monolithic 5Y-TZP fixed partial dentures after thermomechanical aging","volume":"131","author":"ElShamoty","year":"2024","journal-title":"J. Prosthet. Dent."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"2109","DOI":"10.1007\/s00784-022-04813-2","article-title":"Biomechanical behavior of posterior metal-free cantilever fixed dental prostheses: Effect of material and retainer design","volume":"27","author":"Kasem","year":"2022","journal-title":"Clin. Oral Investig."},{"key":"ref_25","doi-asserted-by":"crossref","unstructured":"Kasem, A.T., Abo-Madina, M., Tribst, J.P.M., and Al-Zordk, W. (2023). Cantilever resin-bonded fixed dental prosthesis to substitute a single premolar: Impact of retainer design and ceramic material after dynamic loading. J. Prosthodont. Res.","DOI":"10.2186\/jpr.JPR_D_22_00226"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"1319.e1","DOI":"10.1016\/j.prosdent.2022.09.018","article-title":"Connector design effects on the in vitro fracture resistance of 3-unit monolithic prostheses produced from 4 CAD-CAM materials","volume":"128","author":"Kim","year":"2022","journal-title":"J. Prosthet. Dent."},{"key":"ref_27","doi-asserted-by":"crossref","unstructured":"Ab Ghani, S.M., Mohd Osman, M.L., Chang, H.-C., Ab Ghani, A.R., and Lim, T.W. (2025). Investigation of Connector Parameters for Fracture Strength of Zirconia and Lithium Disilicate Resin-Bonded Fixed Dental Prosthesis. Prosthesis, 7.","DOI":"10.3390\/prosthesis7050115"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"105547","DOI":"10.1016\/j.jmbbm.2022.105547","article-title":"Durability of cantilever inlay-retained fixed dental prosthesis fabricated from multilayered zirconia ceramics with different designs","volume":"137","year":"2023","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"ref_29","doi-asserted-by":"crossref","unstructured":"Coello, R.J., Aita-Holmes, C., Dimalanta, W.G., and Wenger, K. (2022). An in vitro trial on the effect of arch form on connector size requirements in long span anterior zirconia fixed dental prostheses. J. Prosthodont., 1\u20136.","DOI":"10.1111\/jopr.13601"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"251","DOI":"10.3897\/folmed.65.e77442","article-title":"Fracture resistance of 3-unit monolithic ZrO2 ceramics FPDs with different preparation designs of the distal abutment: An in-vitro study","volume":"65","author":"Hadzhigaev","year":"2023","journal-title":"Folia Medica"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"218","DOI":"10.34172\/joddd.2020.039","article-title":"Effect of connector size and design on the fracture resistance of monolithic zirconia fixed dental prosthesis","volume":"14","author":"Hafezeqoran","year":"2020","journal-title":"J. Dent. Res. Dent. Clin. Dent. Prospect."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"84","DOI":"10.21608\/jfcr.2024.260139.1072","article-title":"Effect of Connector Designs on Flexural Strength of Gradient Versus Translucent Monolithic Zirconia Fixed Dental Prosthesis: An in Vitro Study","volume":"4","author":"Lotfy","year":"2024","journal-title":"J. Fundam. Clin. Res."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"171","DOI":"10.4047\/jap.2023.15.4.171","article-title":"Effect of connector configuration on the fracture load in conventional and translucent zirconia three-unit fixed dental prostheses","volume":"15","author":"Subsomboon","year":"2023","journal-title":"J. Adv. Prosthodont."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"336","DOI":"10.37358\/RC.19.1.6912","article-title":"Design Improvement of Y-TZP Three Unit Bridges by Predicted Stress Concentration Using FEA and Experimental Failure Modes after Three Point Bending Test","volume":"70","author":"Almasi","year":"2019","journal-title":"Rev. Chim."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1186\/s13005-025-00484-y","article-title":"The effects of restorative material and connector cross-section area on the stress distribution of fixed partial denture: A finite element analysis","volume":"21","author":"Chen","year":"2025","journal-title":"Head. Face Med."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"315","DOI":"10.1111\/jopr.13146","article-title":"Evaluation of Stress Distribution in Tooth-Supported Fixed Dental Prostheses Made of Translucent Zirconia with Variations in Framework Designs: A Three-Dimensional Finite Element Analysis","volume":"29","author":"Bakitian","year":"2020","journal-title":"J. Prosthodont."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"e53","DOI":"10.1016\/j.dental.2019.01.017","article-title":"Validation of in-vitro tests of zirconia-ceramic inlay-retained fixed partial dentures: A finite element analysis","volume":"35","author":"Waldecker","year":"2019","journal-title":"Dent. Mater."},{"key":"ref_38","first-page":"ZF01","article-title":"Biomechanical Analysis of the Zirconia and Graphene-based CAD-CAM Dental Bridges at Different Pontic Length: A Finite Element Analysis","volume":"14","author":"Alruthea","year":"2020","journal-title":"J. Clin. Diagn. Res."},{"key":"ref_39","first-page":"157","article-title":"Loading stress distribution in posterior teeth restored by different core materials under fixed zirconia partial denture: A 3D-FEA study","volume":"34","author":"Campaner","year":"2021","journal-title":"Am. J. Dent."},{"key":"ref_40","first-page":"667","article-title":"Assessment of Stress Distribution Around Traditional and Sleeve Fixed Partial Denture Designs: Finite Element Analysis","volume":"19","author":"Dimashkieh","year":"2024","journal-title":"Eur. J. Dent."},{"key":"ref_41","doi-asserted-by":"crossref","unstructured":"Miura, S., Kasahara, S., Yamauchi, S., and Egusa, H. (2017). Three-dimensional finite element analysis of zirconia all-ceramic cantilevered fixed partial dentures with different framework designs. Eur. J. Oral Sci., 1\u20137.","DOI":"10.1111\/eos.12342"},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"351","DOI":"10.2186\/jpr.JPR_D_24_00148","article-title":"Finite element analysis of stress distribution in cantilever resin-bonded zirconia fixed dental prosthesis and periodontal tissue with alveolar bone loss","volume":"69","author":"Oishi","year":"2025","journal-title":"J. Prosthodont. Res."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"22","DOI":"10.18231\/j.aprd.2024.005","article-title":"Biomechanical evaluation of four different framework designs of cantilever zirconia resin bonded fixed dental prosthesis: A three-dimensional finite element analysis study","volume":"10","author":"Patel","year":"2024","journal-title":"IP Ann. Prosthodont. Restor. Dent."},{"key":"ref_44","doi-asserted-by":"crossref","unstructured":"Sukumoda, E., Nemoto, R., Nozaki, K., Omori, S., Noda, M., Sato, M., Takita, M., and Miura, H. (2020). Increased Stress Concentration in Prosthesis, Adhesive Cement, and Periodontal Tissue with Zirconia RBFDPs by the Reduced Alveolar Bone Height. J. Prosthodont.","DOI":"10.1111\/jopr.13293"},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"2523","DOI":"10.6026\/973206300212523","article-title":"Effect of span length and connector size on fracture resistance of monolithic zirconia FPDs: A finite element analysis","volume":"21","author":"Lakhe","year":"2025","journal-title":"Bioinformation"},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"8823417","DOI":"10.1155\/ijod\/8823417","article-title":"Comparison of Stress Distribution in Fixed Partial Dentures With an Endocrown Abutment Made of Two Ceramic Materials and Different Residual Tooth Structures, Using Finite Element Analysis","volume":"2026","author":"Zarrati","year":"2026","journal-title":"Int. J. Dent."},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"1234","DOI":"10.4103\/JCDE.JCDE_657_24","article-title":"Endocrown-retained fixed partial dentures: Revolutionizing tooth restoration or risky business? A finite element study","volume":"27","author":"Muthukumar","year":"2024","journal-title":"J. Conserv. Dent. Endod."},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"88","DOI":"10.4103\/jioh.jioh_246_17","article-title":"Comparison between Two Materials for the Fabrication of Modified Design for Posterior Inlay-retained Fixed Dental Prosthesis: A Finite Element Study","volume":"10","author":"Yossef","year":"2018","journal-title":"J. Int. Oral Health"},{"key":"ref_49","first-page":"1","article-title":"Clinical studies of fiber-reinforced resin-bonded fixed partial dentures: A systematic review","volume":"117","author":"Kreulen","year":"2009","journal-title":"Eur. J. Oral Sci."},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"131","DOI":"10.1111\/j.1600-0501.2007.01527.x","article-title":"A systematic review of the survival and complication rates of resin-bonded bridges after an observation period of at least 5 years","volume":"19","author":"Pjetursson","year":"2008","journal-title":"Clin. Oral Implant. Res."},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"99","DOI":"10.17219\/dmp\/152315","article-title":"Comparative evaluation of mechanical effects of two designs of immediately placed customized root-analogue zirconia implants in the maxillary and mandibular posterior regions: A finite element analysis","volume":"62","author":"Divakar","year":"2025","journal-title":"Dent. Med. Probl."},{"key":"ref_52","doi-asserted-by":"crossref","unstructured":"Vorovenci, A., Eftene, O., Burliba\u0219a, M., Dr\u0103gu\u0219, A.C., Mali\u021ba, M.A., Gligor, M.R., Perieanu, V.\u0218., Ionescu, C., St\u0103nescu, R., and Marcov, E.-C. (2026). Clinical Readiness of Additively Manufactured Dental Ceramics for Crowns, Veneers, and Partial-Coverage Restorations: A Scoping Review and Evidence Map. Appl. Sci., 16.","DOI":"10.3390\/app16073594"}],"container-title":["Materials"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1996-1944\/19\/13\/2844\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,8]],"date-time":"2026-07-08T13:00:47Z","timestamp":1783515647000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1996-1944\/19\/13\/2844"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,3]]},"references-count":52,"journal-issue":{"issue":"13","published-online":{"date-parts":[[2026,7]]}},"alternative-id":["ma19132844"],"URL":"https:\/\/doi.org\/10.3390\/ma19132844","relation":{},"ISSN":["1996-1944"],"issn-type":[{"value":"1996-1944","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,3]]}}}