{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,8]],"date-time":"2026-07-08T05:17:33Z","timestamp":1783487853918,"version":"3.55.0"},"reference-count":27,"publisher":"MDPI AG","issue":"13","license":[{"start":{"date-parts":[[2026,7,6]],"date-time":"2026-07-06T00:00:00Z","timestamp":1783296000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Materials"],"abstract":"<jats:p>Although non-structural walls do not determine the structural safety of a building, they are responsible for its functionality by serving as acoustic, thermal, and fire-resistant partitions. They may be freely located and relocated and are typically constructed during the finishing stage of building works. Reliable performance of non-structural walls depends on appropriate connections to floors and adjacent walls. Connections to walls are most commonly achieved using traditional masonry bonding or sufficiently durable wall connectors, usually made of steel. An alternative to steel connectors may be connectors made of polymer-based materials or meshes. This paper proposes an innovative method for connecting non-structural masonry walls using a spatially arranged mesh, which serves not only as reinforcement of the wall connection but also as reinforcement of the bed joints. The aim of the study was to evaluate the effectiveness of this method in comparison with other connection techniques, including traditional solutions. Experimental investigations were carried out using an original test setup on 12 specimens made of AAC masonry units, divided into three series: series P\u2014traditional connection (reference series), series H\u2014connection with mesh placed in bed joints, and series SHP\u2014connection with spatially arranged mesh. Silica Glass Mesh (SGM), intended for reinforcement of bed joints in AAC masonry, was used in the study. The experiments focused on the analysis of connection behavior and load-bearing capacity, with particular emphasis on maximum load values and failure mechanisms. Individual stages of the behavior of mesh-reinforced connections were identified, and empirical relationships enabling estimation of maximum loads were developed. The results confirmed that the traditional connection achieved the highest load-bearing capacity. However, as expected, the mesh-reinforced connections\u2014particularly those with the spatial mesh arrangement\u2014exhibited a more stable response and a greater ability for progressive load transfer. The SHP series connections with spatially arranged meshes exhibited significantly lower load-bearing capacity compared to the reference unreinforced connections, while at the same time demonstrating substantially greater deformability. The stiffness degradation in the mesh-reinforced connections did not occur abruptly, as observed in the reference models, which makes them an effective alternative for practical applications. Technical models for predicting forces and displacements of connections reinforced with spatially arranged meshes and meshes placed in bed joints were also developed.<\/jats:p>","DOI":"10.3390\/ma19132900","type":"journal-article","created":{"date-parts":[[2026,7,6]],"date-time":"2026-07-06T14:56:42Z","timestamp":1783349802000},"page":"2900","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Innovative Connection of Non-Load-Bearing Walls Using a Spatially Arranged Silica Glass Mesh"],"prefix":"10.3390","volume":"19","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4015-4971","authenticated-orcid":false,"given":"Rados\u0142aw","family":"Jasi\u0144ski","sequence":"first","affiliation":[{"name":"Department of Building Structures, Silesian University of Technology, Akademicka 5, 44-100 Gliwice, Poland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0196-6478","authenticated-orcid":false,"given":"Iwona","family":"Galman","sequence":"additional","affiliation":[{"name":"Department of Structural Engineering, Silesian University of Technology, Akademicka 5, 44-100 Gliwice, Poland"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2026,7,6]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"107428","DOI":"10.1016\/j.soildyn.2022.107428","article-title":"Seismic upgrading of existing masonry structures: A state-of-the-art review","volume":"161","author":"Gkournelos","year":"2022","journal-title":"Soil Dyn. Earthq. Eng."},{"key":"ref_2","doi-asserted-by":"crossref","unstructured":"Hafner, I., Ki\u0161i\u010dek, T., and Gams, M. (2023). Review of Methods for Seismic Strengthening of Masonry Piers and Walls. Buildings, 13.","DOI":"10.3390\/buildings13061524"},{"key":"ref_3","doi-asserted-by":"crossref","unstructured":"Borah, B., Kaushik, H.B., and Singhal, V. (2023). Analysis and Design of Confined Masonry Structures: Review and Future Research Directions. Buildings, 13.","DOI":"10.3390\/buildings13051282"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"313","DOI":"10.1007\/s11803-016-0324-2","article-title":"Shear reinforcement effect of reinforced concrete tie-columns on the lateral resistance of confined masonry walls","volume":"15","author":"Bouhedja","year":"2016","journal-title":"Earthq. Eng. Eng. Vib."},{"key":"ref_5","doi-asserted-by":"crossref","unstructured":"P\u00e9rez Gavil\u00e1n Escalante, J.J., Flores, L.E., Alcocer, S.M., and Zegarra, L.F. (2023). Experimental Research Studies on Seismic Behaviour of Confined Masonry Structures: A Review. Buildings, 13.","DOI":"10.3390\/buildings13071776"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"2116","DOI":"10.1177\/87552930241246148","article-title":"Design of tie-columns in confined masonry structures for lateral loads","volume":"40","author":"Borah","year":"2024","journal-title":"Earthq. Spectra"},{"key":"ref_7","unstructured":"(2013). Specification for Ancillary Components for Masonry\u2014Part 1: Wall Ties, Tension Straps, Hangers and Brackets (Standard No. EN 845-1:2013)."},{"key":"ref_8","doi-asserted-by":"crossref","unstructured":"Candela, M., Borri, A., Corradi, M., and Righetti, L. (2016). Effect of Transversal Steel Connectors on the Behavior of Rubble Stone-Masonry Walls: Two Case Studies in Italy. Brick and Block Masonry: Trends, Innovations and Challenges\u2014Proceedings of the 16th International Brick and Block Masonry Conference (IBMAC 2016), Padova, Italy, 26\u201330 June 2016, CRC Press\/Balkema.","DOI":"10.1201\/b21889-252"},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Cisma\u015fiu, I., Azevedo, N.M., and Pinho, F.F.S. (2023). Numerical Evaluation of Transverse Steel Connector Strengthening Effect on the Behavior of Rubble Stone Masonry Walls under Compression Using a Particle Model. Buildings, 13.","DOI":"10.3390\/buildings13040987"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"4033","DOI":"10.1080\/13632469.2020.1822231","article-title":"An Experimental Study on Finding Prequalified Connectors between the Wall and Steel Frame Infilled with Autoclave-Cured Aerated Concrete Blocks","volume":"26","author":"Asadzadeh","year":"2022","journal-title":"J. Earthq. Eng."},{"key":"ref_11","first-page":"79","article-title":"Tests of joints in AAC masonry walls","volume":"11","author":"Galman","year":"2018","journal-title":"Archit. Civ. Eng. Environ."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"122024","DOI":"10.1016\/j.engstruct.2025.122024","article-title":"Procedure and test stand for determining the shear strength of masonry wall joints\u2014Comparative and numerical analysis","volume":"350","author":"Galman","year":"2026","journal-title":"Eng. Struct."},{"key":"ref_13","unstructured":"Nova Sp. z o.o. (2022). Product Data Sheet\u2014P30 Galvanized Connector, Version 2022.02.04, Nova Sp. z o.o."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"94","DOI":"10.1016\/j.conbuildmat.2015.04.014","article-title":"Experimental and analytical study to evaluate the effectiveness of an in-plane reinforcement for masonry walls using GFRP meshes","volume":"88","author":"Gattesco","year":"2015","journal-title":"Constr. Build. Mater."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"1703","DOI":"10.1007\/s10518-014-9684-z","article-title":"Diagonal compression tests on masonry walls strengthened with a GFRP mesh reinforced mortar coating","volume":"13","author":"Gattesco","year":"2015","journal-title":"Bull. Earthq. Eng."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"117905","DOI":"10.1016\/j.conbuildmat.2019.117905","article-title":"In-plane shear behaviour by diagonal compression testing of brick masonry walls strengthened with basalt and steel textile reinforced mortars","volume":"240","author":"Roca","year":"2020","journal-title":"Constr. Build. Mater."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"209","DOI":"10.1016\/j.compstruct.2017.01.043","article-title":"Characterization tests of GFRM coating as a strengthening technique for masonry buildings","volume":"165","author":"Gattesco","year":"2017","journal-title":"Compos. Struct."},{"key":"ref_18","unstructured":"(2024). Kits Made of AR Glass Fibre Mesh, Connectors and Mortar for Strengthening of Masonry and Reinforced Concrete Elements (Standard No. EAD 340451-00-0104)."},{"key":"ref_19","doi-asserted-by":"crossref","unstructured":"Jasi\u0144ski, R., and Galman, I. (2020). Testing joints between walls made of AAC masonry units. Buildings, 10.","DOI":"10.3390\/buildings10040069"},{"key":"ref_20","unstructured":"(2013). Eurocode 6: Design of Masonry Structures. Part 1-1: General Rules for Reinforced and Unreinforced Masonry Structures (Standard No. PN-EN 1996-1-1+A1:2013-05P)."},{"key":"ref_21","first-page":"125","article-title":"Morphology of cracks and comparison of load-bearing capacity of joints of AAC masonry walls","volume":"6","author":"Galman","year":"2023","journal-title":"Ce\/Pap. Online Collect. Conf. Pap. Civ. Eng."},{"key":"ref_22","unstructured":"(2000). Methods of Test for Masonry\u2014Part 1: Determination of Compressive Strength (Standard No. PN-EN 1052-1:2000)."},{"key":"ref_23","unstructured":"(2004). Methods of Test for Masonry\u2014Part 3: Determination of Initial Shear Strength (Standard No. PN-EN 1052-3:2004)."},{"key":"ref_24","unstructured":"(1981). Standard Test Method for Diagonal Tension (Shear) of Masonry Assemblages (Standard No. ASTM E519-81)."},{"key":"ref_25","unstructured":"MAP Products Pvt. Ltd (2026, June 24). TBM-Reinforcement\u2122 for AAC Block Masonry. Product Data Sheet. MAP Products Pvt. Ltd., Ahmedabad, India. Available online: https:\/\/pdf.indiamart.com\/impdf\/13271920112\/MY-33840623\/tbm-reinforcement.pdf."},{"key":"ref_26","unstructured":"(2011). Standard Test Method for Breaking Force and Elongation of Textile Fabrics (Strip Method) (Standard No. ASTM D-5035-2011:R2024)."},{"key":"ref_27","unstructured":"Volk, W. (2013). Applied Statistics for Engineers, Literary Licensing, LLC."}],"container-title":["Materials"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1996-1944\/19\/13\/2900\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,8]],"date-time":"2026-07-08T04:54:23Z","timestamp":1783486463000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1996-1944\/19\/13\/2900"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,6]]},"references-count":27,"journal-issue":{"issue":"13","published-online":{"date-parts":[[2026,7]]}},"alternative-id":["ma19132900"],"URL":"https:\/\/doi.org\/10.3390\/ma19132900","relation":{},"ISSN":["1996-1944"],"issn-type":[{"value":"1996-1944","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,6]]}}}