{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,12]],"date-time":"2026-09-12T05:06:19Z","timestamp":1789189579801,"version":"build-2803163510"},"reference-count":134,"publisher":"MDPI AG","issue":"18","license":[{"start":{"date-parts":[[2026,9,10]],"date-time":"2026-09-10T00:00:00Z","timestamp":1788998400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Materials"],"abstract":"<jats:p>An aging population and a rising revision burden are increasing demand for bone-compatible load-bearing implants. Because the elastic modulus of conventional Ti-6Al-4V (~110 GPa) exceeds that of cortical bone (7\u201330 GPa), stress shielding can drive bone resorption and aseptic loosening. Two solution lines have emerged: low-modulus \u03b2-type alloys and porous architectures. Focusing on additive manufacturing (AM), this critical narrative review synthesizes the evidence along the axis of clinical failure modes. Materials science has lowered \u03b2-Ti\u2019s modulus to ~40 GPa in bulk, yet clinical implants rely predominantly on porous conventional Ti-6Al-4V: the low effective modulus (single-digit GPa) comes from architecture, not alloying. These architectures range from porous fixation surfaces on solid acetabular shells to predominantly porous constructs\u2014revision knee cones and sleeves, acetabular augments, and spinal interbody cages. In the acetabular cohorts, where clinical evidence is concentrated, short- to mid-term survivorship is favorable though heterogeneous; revisions were driven mainly by infection and instability, with aseptic loosening low. Two tools are proposed: a synthesis matrix setting laboratory claims alongside clinical evidence for each design parameter, and a 16-item minimum reporting checklist. Applied to the 12 primary series reviewed, the checklist found manufacturing and architecture-verification parameters largely unreported even where clinical outcomes are well documented.<\/jats:p>","DOI":"10.3390\/ma19183860","type":"journal-article","created":{"date-parts":[[2026,9,10]],"date-time":"2026-09-10T14:11:22Z","timestamp":1789049482000},"page":"3860","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Porous Ti-6Al-4V Architectures in Load-Bearing Orthopedic Reconstruction: A Critical Narrative Review of the Translational Gap Across Microstructure, Fatigue, Surface Function, and Clinical Failure Modes"],"prefix":"10.3390","volume":"19","author":[{"given":"G\u00fcnd\u00fcz Ercan","family":"Kutluay","sequence":"first","affiliation":[{"name":"Department of Orthopedics and Traumatology, \u00c7OSB Kapakl\u0131 State Hospital, 59500 Tekirda\u011f, T\u00fcrkiye"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fatih","family":"Erdo\u011fan","sequence":"additional","affiliation":[{"name":"Department of Orthopedics and Traumatology, Faculty of Medicine, Tekirda\u011f Nam\u0131k Kemal University, 59030 Tekirda\u011f, T\u00fcrkiye"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6576-1802","authenticated-orcid":false,"given":"Ya\u015far Mahsut","family":"Din\u00e7el","sequence":"additional","affiliation":[{"name":"Department of Orthopedics and Traumatology, Faculty of Medicine, Tekirda\u011f Nam\u0131k Kemal University, 59030 Tekirda\u011f, T\u00fcrkiye"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2026,9,10]]},"reference":[{"key":"ref_1","first-page":"100011","article-title":"Additive manufacturing of titanium alloys for biomedical applications: A systematic review","volume":"1","author":"Gao","year":"2025","journal-title":"Rev. Mater. Res."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1016\/j.artd.2022.08.007","article-title":"Minimum 2-Year Outcomes of a Novel 3D-printed Fully Porous Titanium Acetabular Shell in Revision Total Hip Arthroplasty","volume":"18","author":"Berlinberg","year":"2022","journal-title":"Arthroplast. Today"},{"key":"ref_3","doi-asserted-by":"crossref","unstructured":"McCloskey, C.P., Sunkara, A., Kalala, S., Peterson, J.T., Sohn, M.O., Chen, A.R., Movva, A.K., and Anastasio, A.T. (2026). Patient-Specific 3D-Printed Porous Metal Implants in Orthopedics: A Narrative Review of Current Applications and Future Prospects. Appl. Sci., 16.","DOI":"10.3390\/app16073192"},{"key":"ref_4","first-page":"1374","article-title":"Risk factors affecting the incidence of postoperative periprosthetic femoral fracture in primary hip arthroplasty patients: A retrospective study","volume":"15","author":"Ding","year":"2023","journal-title":"Am. J. Transl. Res."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"53","DOI":"10.5371\/hp.2021.33.2.53","article-title":"Factors Affecting Periprosthetic Bone Loss after Hip Arthroplasty","volume":"33","author":"Lee","year":"2021","journal-title":"Hip Pelvis"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"836587","DOI":"10.1155\/2011\/836587","article-title":"Titanium-based biomaterials for preventing stress shielding between implant devices and bone","volume":"2011","author":"Niinomi","year":"2011","journal-title":"Int. J. Biomater."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1007\/s10195-016-0391-1","article-title":"Trunnionosis in total hip arthroplasty: A review","volume":"17","author":"Mistry","year":"2016","journal-title":"J. Orthop. Traumatol."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"149","DOI":"10.1097\/00003086-200208000-00018","article-title":"A multicenter retrieval study of the taper interfaces of modular hip prostheses","volume":"401","author":"Goldberg","year":"2002","journal-title":"Clin. Orthop. Relat. Res."},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Guo, C., Ding, T., Cheng, Y., Zheng, J., Fang, X., and Feng, Z. (2025). The rational design, biofunctionalization and biological properties of orthopedic porous titanium implants: A review. Front. Bioeng. Biotechnol., 13.","DOI":"10.3389\/fbioe.2025.1548675"},{"key":"ref_10","unstructured":"(2021). Additive Manufacturing\u2014General Principles\u2014Fundamentals and Vocabulary (Standard No. ISO\/ASTM 52900:2021)."},{"key":"ref_11","unstructured":"(2021). Standard Specification for Additive Manufacturing Titanium-6 Aluminum-4 Vanadium with Powder Bed Fusion (Standard No. ASTM F2924-14(2021))."},{"key":"ref_12","unstructured":"(2021). Standard Specification for Additive Manufacturing Titanium-6 Aluminum-4 Vanadium ELI (Extra Low Interstitial) with Powder Bed Fusion (Standard No. ASTM F3001-14(2021))."},{"key":"ref_13","unstructured":"(2025). Additive Manufacturing for Medical\u2014General Principles\u2014Additive Manufacturing of Non-Active Implants (Standard No. ISO 5092:2025)."},{"key":"ref_14","unstructured":"(2018). Biological Evaluation of Medical Devices\u2014Part 1: Evaluation and Testing Within a Risk Management Process (Standard No. ISO 10993-1:2018)."},{"key":"ref_15","unstructured":"OCEBM Levels of Evidence Working Group (2026, August 26). The Oxford 2011 Levels of Evidence. Oxford Centre for Evidence-Based Medicine. Available online: https:\/\/www.cebm.ox.ac.uk\/resources\/levels-of-evidence\/ocebm-levels-of-evidence."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"878","DOI":"10.1177\/21925682221124527","article-title":"Porous 3D Printed Titanium Cages in Anterior Cervical Discectomy and Fusion are Associated With Less Subsidence, Improved Maintenance of Segmental Lordotic Correction, and Similar Clinical Outcomes as Allograft","volume":"14","author":"Singh","year":"2024","journal-title":"Glob. Spine J."},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Almeida, P.R., Macpherson, G.J., Simpson, P., Gaston, P., and Clement, N.D. (2025). The Use of Highly Porous 3-D-Printed Titanium Acetabular Cups in Revision Total Hip Arthroplasty: A Systematic Review and Meta-Analysis. J. Clin. Med., 14.","DOI":"10.3390\/jcm14030938"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"35891","DOI":"10.52965\/001c.35891","article-title":"Short-term survivorship of 3D-printed titanium metaphyseal cones in revision total knee arthroplasty: A systematic review","volume":"14","author":"Mancino","year":"2022","journal-title":"Orthop. Rev."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"712","DOI":"10.1046\/j.1445-2197.2003.02748.x","article-title":"Methodological index for non-randomized studies (MINORS): Development and validation of a new instrument","volume":"73","author":"Slim","year":"2003","journal-title":"ANZ J. Surg."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1186\/s42836-022-00152-5","article-title":"Outcomes of novel 3D-printed fully porous titanium cup and a cemented highly cross-linked polyethylene liner in complex and revision total hip arthroplasty","volume":"4","author":"Shichman","year":"2022","journal-title":"Arthroplasty"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"102282","DOI":"10.1016\/j.jcot.2023.102282","article-title":"Mid term outcomes of a novel metaphyseal porous titanium cone in revision total knee arthroplasty","volume":"46","author":"Shichman","year":"2023","journal-title":"J. Clin. Orthop. Trauma"},{"key":"ref_22","doi-asserted-by":"crossref","unstructured":"Baltatu, M.S., Vizureanu, P., Sandu, A.V., Solcan, C., Hritcu, L.D., and Spataru, M.C. (2023). Research progress of titanium-based alloys for medical devices. Biomedicines, 11.","DOI":"10.3390\/biomedicines11112997"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"397","DOI":"10.1016\/j.pmatsci.2008.06.004","article-title":"Ti based biomaterials, the ultimate choice for orthopaedic implants\u2014A review","volume":"54","author":"Geetha","year":"2009","journal-title":"Prog. Mater. Sci."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"1621","DOI":"10.1016\/S0142-9612(97)00146-4","article-title":"Titanium alloys in total joint replacement\u2014A materials science perspective","volume":"19","author":"Long","year":"1998","journal-title":"Biomaterials"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"101277","DOI":"10.1016\/j.pmatsci.2024.101277","article-title":"Towards load-bearing biomedical titanium-based alloys: From essential requirements to future developments","volume":"144","author":"Cui","year":"2024","journal-title":"Prog. Mater. Sci."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"30","DOI":"10.1016\/j.jmbbm.2007.07.001","article-title":"Mechanical biocompatibilities of titanium alloys for biomedical applications","volume":"1","author":"Niinomi","year":"2008","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"3888","DOI":"10.1016\/j.actbio.2012.06.037","article-title":"Development of new metallic alloys for biomedical applications","volume":"8","author":"Niinomi","year":"2012","journal-title":"Acta Biomater."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"244","DOI":"10.1016\/S0921-5093(97)00808-3","article-title":"Design and mechanical properties of new \u03b2 type titanium alloys for implant materials","volume":"243","author":"Kuroda","year":"1998","journal-title":"Mater. Sci. Eng. A"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"464","DOI":"10.1126\/science.1081957","article-title":"Multifunctional alloys obtained via a dislocation-free plastic deformation mechanism","volume":"300","author":"Saito","year":"2003","journal-title":"Science"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"277","DOI":"10.1016\/j.actbio.2006.11.002","article-title":"Elastic deformation behaviour of Ti-24Nb-4Zr-7.9Sn for biomedical applications","volume":"3","author":"Hao","year":"2007","journal-title":"Acta Biomater."},{"key":"ref_31","doi-asserted-by":"crossref","unstructured":"Guo, A.X.Y., Cao, B., Wang, Z., Ma, X., and Cao, S.C. (2023). Fabricated High-Strength, Low-Elastic Modulus Biomedical Ti-24Nb-4Zr-8Sn Alloy via Powder Metallurgy. Materials, 16.","DOI":"10.3390\/ma16103845"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"164","DOI":"10.1016\/j.jor.2023.11.002","article-title":"Large head metal-on-metal bearing surface with a TMZF titanium alloy femoral stem with high rates of revision and trunnion failure","volume":"46","author":"McCarthy","year":"2023","journal-title":"J. Orthop."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1186\/s10195-023-00743-1","article-title":"Unexpected early loosening of rectangular straight femoral Zweym\u00fcller stems with an alumina-reduced surface","volume":"25","author":"Moret","year":"2024","journal-title":"J. Orthop. Traumatol."},{"key":"ref_34","unstructured":"(2021). Standard Specification for Wrought Titanium-13Niobium-13Zirconium Alloy for Surgical Implant Applications (UNS R58130) (Standard No. ASTM F1713-08(2021)e1)."},{"key":"ref_35","doi-asserted-by":"crossref","unstructured":"Klinge, L., Kluy, L., Spiegel, C., Siemers, C., Groche, P., and Cora\u00e7a-Huber, D. (2023). Nanostructured Ti-13Nb-13Zr alloy for implant application\u2014Material scientific, technological, and biological aspects. Front. Bioeng. Biotechnol., 11.","DOI":"10.3389\/fbioe.2023.1255947"},{"key":"ref_36","unstructured":"(2023). Standard Specification for Wrought Titanium-15Molybdenum Alloy for Surgical Implant Applications (UNS R58150) (Standard No. ASTM F2066-23)."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"2857","DOI":"10.1016\/j.arth.2017.03.075","article-title":"Trunnion Failure of the Recalled Low Friction Ion Treatment Cobalt Chromium Alloy Femoral Head","volume":"32","author":"Urish","year":"2017","journal-title":"J. Arthroplast."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"481","DOI":"10.1177\/1120700020919665","article-title":"Catastrophic failure of the Accolade I hip arthroplasty stem: A retrieval analysis study","volume":"30","author":"Wylde","year":"2020","journal-title":"Hip Int."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"114","DOI":"10.1080\/09506608.2020.1735829","article-title":"Comprehensive review on alloy design, processing, and performance of \u03b2 titanium alloys as biomedical materials","volume":"66","author":"Bahl","year":"2021","journal-title":"Int. Mater. Rev."},{"key":"ref_40","doi-asserted-by":"crossref","unstructured":"Yang, S., Jia, Z., Song, X., He, J., and Zhang, X. (2026). Development of Ti-Nb-Mo-Zr Alloys with Low Modulus and Excellent Plasticity for Biomedical Applications. Materials, 19.","DOI":"10.3390\/ma19020325"},{"key":"ref_41","first-page":"1251","article-title":"A review on \u03b2-Ti alloys for biomedical applications: The influence of alloy composition and thermomechanical processing on mechanical properties, phase composition, and microstructure","volume":"237","author":"Kanapaakala","year":"2023","journal-title":"Proc. Inst. Mech. Eng. Part L J. Mater. Des. Appl."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"2403129","DOI":"10.1002\/adhm.202403129","article-title":"Rethinking biomedical titanium alloy design: A review of challenges from biological and manufacturing perspectives","volume":"14","author":"Rabbitt","year":"2025","journal-title":"Adv. Healthc. Mater."},{"key":"ref_43","doi-asserted-by":"crossref","unstructured":"Wong, K.-K., Hsu, H.-C., Wu, S.-C., and Ho, W.-F. (2023). A Review: Design from Beta Titanium Alloys to Medium-Entropy Alloys for Biomedical Applications. Materials, 16.","DOI":"10.3390\/ma16217046"},{"key":"ref_44","doi-asserted-by":"crossref","unstructured":"Mishchenko, O., Ovchynnykov, O., Kapustian, O., and Pogorielov, M. (2020). New Zr-Ti-Nb Alloy for Medical Application: Development, Chemical and Mechanical Properties, and Biocompatibility. Materials, 13.","DOI":"10.3390\/ma13061306"},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1016\/j.jjoisr.2023.09.004","article-title":"Five-year clinical and radiographic outcomes of Accolade TMZF and Accolade II stem use","volume":"2","author":"Ueoka","year":"2024","journal-title":"J. Jt. Surg. Res."},{"key":"ref_46","first-page":"286","article-title":"Gross trunnion failure in total hip arthroplasty: A case study and review article","volume":"6","author":"Scott","year":"2022","journal-title":"Arch. Clin. Med. Case Rep."},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"2309499018807747","DOI":"10.1177\/2309499018807747","article-title":"The Accolade TMZF stem fulfils the demands of modern stem design: Minimum 5-year survival in a cohort of 937 patients","volume":"26","author":"Koenraadt","year":"2018","journal-title":"J. Orthop. Surg."},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"907","DOI":"10.1302\/0301-620X.81B5.0810907","article-title":"Characteristics of bone ingrowth and interface mechanics of a new porous tantalum biomaterial","volume":"81-B","author":"Bobyn","year":"1999","journal-title":"J. Bone Jt. Surg. Br."},{"key":"ref_49","doi-asserted-by":"crossref","unstructured":"Yadav, M.K., Yarlapati, A., Aditya, Y.N., Kesavan, P., Pandey, V., Perugu, C.S., Nain, A., Chatterjee, K., Suwas, S., and Jayamani, J. (2025). Processing and Development of Porous Titanium for Biomedical Applications: A Comprehensive Review. J. Manuf. Mater. Process., 9.","DOI":"10.3390\/jmmp9120401"},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1016\/j.jmbbm.2008.05.004","article-title":"Microstructure and mechanical behavior of Ti-6Al-4V produced by rapid-layer manufacturing, for biomedical applications","volume":"2","author":"Murr","year":"2009","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"ref_51","doi-asserted-by":"crossref","unstructured":"Ramirez, B., Banuelos, C., De La Cruz, A., Nabil, S.T., Arrieta, E., Murr, L.E., Wicker, R.B., and Medina, F. (2024). Effects of Process Parameters and Process Defects on the Flexural Fatigue Life of Ti-6Al-4V Fabricated by Laser Powder Bed Fusion. Materials, 17.","DOI":"10.3390\/ma17184548"},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"7308","DOI":"10.1038\/s41598-017-06504-5","article-title":"The influence of porosity on fatigue crack initiation in additively manufactured titanium components","volume":"7","author":"Withers","year":"2017","journal-title":"Sci. Rep."},{"key":"ref_53","doi-asserted-by":"crossref","first-page":"420","DOI":"10.1002\/jbm.b.34710","article-title":"Analysis of the mechanical and physicochemical properties of Ti-6Al-4V discs obtained by selective laser melting and subtractive manufacturing method","volume":"109","author":"Kreve","year":"2021","journal-title":"J. Biomed. Mater. Res. B Appl. Biomater."},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"639","DOI":"10.1007\/s11837-015-1307-x","article-title":"Powder Removal from Ti-6Al-4V Cellular Structures Fabricated via Electron Beam Melting","volume":"67","author":"Hasib","year":"2015","journal-title":"JOM"},{"key":"ref_55","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1051\/meca\/2022023","article-title":"A new method with ultrasonic mechanism for efficient depowdering of parts produced by electron beam melting","volume":"23","author":"Doutre","year":"2022","journal-title":"Mech. Ind."},{"key":"ref_56","first-page":"103896","article-title":"Effect of chemical\u2013electrochemical surface treatment on the roughness and fatigue performance of porous titanium lattice structures","volume":"78","author":"Oosterbeek","year":"2023","journal-title":"Addit. Manuf."},{"key":"ref_57","unstructured":"U.S. Food and Drug Administration (2017). Technical Considerations for Additive Manufactured Medical Devices: Guidance for Industry and Food and Drug Administration Staff."},{"key":"ref_58","doi-asserted-by":"crossref","first-page":"103671","DOI":"10.1016\/j.jmbbm.2020.103671","article-title":"Rational design, bio-functionalization and biological performance of hybrid additive manufactured titanium implants for orthopaedic applications: A review","volume":"105","author":"Li","year":"2020","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"ref_59","doi-asserted-by":"crossref","first-page":"1774","DOI":"10.1002\/jor.23445","article-title":"Fully porous 3D printed titanium femoral stem to reduce stress-shielding following total hip arthroplasty","volume":"35","author":"Arabnejad","year":"2017","journal-title":"J. Orthop. Res."},{"key":"ref_60","doi-asserted-by":"crossref","first-page":"383","DOI":"10.1007\/s40964-019-00078-6","article-title":"Powders for powder bed fusion: A review","volume":"4","author":"Vock","year":"2019","journal-title":"Prog. Addit. Manuf."},{"key":"ref_61","doi-asserted-by":"crossref","first-page":"555","DOI":"10.1007\/s11837-015-1300-4","article-title":"Effect of Powder Reuse Times on Additive Manufacturing of Ti-6Al-4V by Selective Electron Beam Melting","volume":"67","author":"Tang","year":"2015","journal-title":"JOM"},{"key":"ref_62","first-page":"124","article-title":"Mechanical equivalent diameter of single struts for the stiffness prediction of lattice structures produced by Electron Beam Melting","volume":"8","author":"Suard","year":"2015","journal-title":"Addit. Manuf."},{"key":"ref_63","doi-asserted-by":"crossref","unstructured":"Wei\u00dfmann, V., Drescher, P., Bader, R., Seitz, H., Hansmann, H., and Laufer, N. (2017). Comparison of Single Ti6Al4V Struts Made Using Selective Laser Melting and Electron Beam Melting Subject to Part Orientation. Metals, 7.","DOI":"10.3390\/met7030091"},{"key":"ref_64","doi-asserted-by":"crossref","unstructured":"Naghavi, S.A., Tamaddon, M., Marghoub, A., Wang, K., Babamiri, B.B., Hazeli, K., Xu, W., Lu, X., Sun, C., and Wang, L. (2022). Mechanical Characterisation and Numerical Modelling of TPMS-Based Gyroid and Diamond Ti6Al4V Scaffolds for Bone Implants: An Integrated Approach for Translational Consideration. Bioengineering, 9.","DOI":"10.3390\/bioengineering9100504"},{"key":"ref_65","doi-asserted-by":"crossref","first-page":"572","DOI":"10.1016\/j.actbio.2017.02.024","article-title":"Additively manufactured metallic porous biomaterials based on minimal surfaces: A unique combination of topological, mechanical, and mass transport properties","volume":"53","author":"Bobbert","year":"2017","journal-title":"Acta Biomater."},{"key":"ref_66","doi-asserted-by":"crossref","first-page":"690","DOI":"10.1016\/j.msec.2015.10.069","article-title":"Effect of pore size on bone ingrowth into porous titanium implants fabricated by additive manufacturing: An in vivo experiment","volume":"59","author":"Taniguchi","year":"2016","journal-title":"Mater. Sci. Eng. C"},{"key":"ref_67","first-page":"77","article-title":"Effects of build orientation and heat treatment on the microstructure and mechanical properties of selective laser melted Ti6Al4V lattice structures","volume":"5","author":"Wauthle","year":"2015","journal-title":"Addit. Manuf."},{"key":"ref_68","doi-asserted-by":"crossref","first-page":"74","DOI":"10.1016\/j.actamat.2014.11.028","article-title":"Additive manufacturing of strong and ductile Ti-6Al-4V by selective laser melting via in situ martensite decomposition","volume":"85","author":"Xu","year":"2015","journal-title":"Acta Mater."},{"key":"ref_69","doi-asserted-by":"crossref","first-page":"e202400032","DOI":"10.1002\/cben.202400032","article-title":"Review of 3D-printed titanium-based implants: Materials and post-processing","volume":"11","author":"Li","year":"2024","journal-title":"ChemBioEng Rev."},{"key":"ref_70","doi-asserted-by":"crossref","first-page":"177","DOI":"10.1016\/j.jallcom.2012.07.022","article-title":"Heat treatment of Ti6Al4V produced by Selective Laser Melting: Microstructure and mechanical properties","volume":"541","author":"Vrancken","year":"2012","journal-title":"J. Alloys Compd."},{"key":"ref_71","doi-asserted-by":"crossref","unstructured":"Li, Z., and Affolter, C. (2024). High-Cycle Fatigue Performance of Laser Powder Bed Fusion Ti-6Al-4V Alloy with Inherent Internal Defects: A Critical Literature Review. Metals, 14.","DOI":"10.3390\/met14090972"},{"key":"ref_72","doi-asserted-by":"crossref","unstructured":"Xi, J., Hu, Y., Xing, H., Han, Y., Zhang, H., Jiang, J., and Nikbin, K. (2021). The Low-Cycle Fatigue Behavior, Failure Mechanism and Prediction of SLM Ti-6Al-4V Alloy with Different Heat Treatment Methods. Materials, 14.","DOI":"10.3390\/ma14216276"},{"key":"ref_73","doi-asserted-by":"crossref","unstructured":"Jamshidi, P., Aristizabal, M., Kong, W., Villapun, V., Cox, S.C., Grover, L.M., and Attallah, M.M. (2020). Selective Laser Melting of Ti-6Al-4V: The Impact of Post-processing on the Tensile, Fatigue and Biological Properties for Medical Implant Applications. Materials, 13.","DOI":"10.3390\/ma13122813"},{"key":"ref_74","unstructured":"(2017). Standard Specification and Test Method for Metallic Bone Plates (Standard No. ASTM F382-17)."},{"key":"ref_75","unstructured":"(2010). Implants for Surgery\u2014Partial and Total Hip Joint Prostheses\u2014Part 4: Determination of Endurance Properties and Performance of Stemmed Femoral Components (Standard No. ISO 7206-4:2010)."},{"key":"ref_76","unstructured":"(2024). Standard Test Method for Fatigue Testing of Acetabular Devices for Total Hip Replacement and Performance Requirements (Standard No. ASTM F3090-24)."},{"key":"ref_77","doi-asserted-by":"crossref","first-page":"4957","DOI":"10.1038\/s41598-018-23414-2","article-title":"Fatigue life of additively manufactured Ti6Al4V scaffolds under tension-tension, tension-compression and compression-compression fatigue load","volume":"8","author":"Lietaert","year":"2018","journal-title":"Sci. Rep."},{"key":"ref_78","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1016\/j.prostr.2017.11.055","article-title":"Effects of Defects, Surface Roughness and HIP on Fatigue Strength of Ti-6Al-4V manufactured by Additive Manufacturing","volume":"7","author":"Masuo","year":"2017","journal-title":"Procedia Struct. Integr."},{"key":"ref_79","doi-asserted-by":"crossref","first-page":"4849","DOI":"10.1016\/j.msec.2013.08.006","article-title":"Fatigue behavior of porous biomaterials manufactured using selective laser melting","volume":"33","author":"Wauthle","year":"2013","journal-title":"Mater. Sci. Eng. C"},{"key":"ref_80","doi-asserted-by":"crossref","first-page":"8131","DOI":"10.1007\/s11665-025-11916-w","article-title":"Compression Behavior and Fatigue Strength of Additively Manufactured Ti6Al4V Strut-Based Lattice Structures: A Review","volume":"35","author":"Parameswaran","year":"2026","journal-title":"J. Mater. Eng. Perform."},{"key":"ref_81","doi-asserted-by":"crossref","first-page":"109825","DOI":"10.1016\/j.engfailanal.2025.109825","article-title":"High- and low-cycle fatigue behavior of additively manufactured Ti6Al4V and influence of surface finish","volume":"180","author":"Pagliari","year":"2025","journal-title":"Eng. Fail. Anal."},{"key":"ref_82","doi-asserted-by":"crossref","first-page":"305","DOI":"10.1016\/j.actamat.2020.05.041","article-title":"High cycle fatigue in selective laser melted Ti-6Al-4V","volume":"194","author":"Kumar","year":"2020","journal-title":"Acta Mater."},{"key":"ref_83","doi-asserted-by":"crossref","first-page":"706","DOI":"10.1093\/jleuko\/qiae072","article-title":"Titanium induces proinflammatory and tissue-destructive responses in primary human macrophages","volume":"116","author":"Gudima","year":"2024","journal-title":"J. Leukoc. Biol."},{"key":"ref_84","doi-asserted-by":"crossref","first-page":"3780","DOI":"10.1016\/j.jmrt.2024.04.136","article-title":"From clinic to lab: Advances in porous titanium-based orthopedic implant research","volume":"30","author":"Li","year":"2024","journal-title":"J. Mater. Res. Technol."},{"key":"ref_85","doi-asserted-by":"crossref","unstructured":"Huang, X., Gong, X., Xu, A., Zhang, W., Li, Y., Jia, Y., Yang, W., Yuan, N., Yang, Y., and Wang, D. (2026). Research progress on osseointegration performance of porous structure-modified titanium alloy implants. Front. Bioeng. Biotechnol., 14.","DOI":"10.3389\/fbioe.2026.1748736"},{"key":"ref_86","doi-asserted-by":"crossref","unstructured":"Kozelskaya, A.I., Rutkowski, S., Frueh, J., Gogolev, A.S., Chistyakov, S.G., Gnedenkov, S.V., Sinebryukhov, S.L., Frueh, A., Egorkin, V.S., and Choynzonov, E.L. (2022). Surface Modification of Additively Fabricated Titanium-Based Implants by Means of Bioactive Micro-Arc Oxidation Coatings for Bone Replacement. J. Funct. Biomater., 13.","DOI":"10.3390\/jfb13040285"},{"key":"ref_87","doi-asserted-by":"crossref","first-page":"17964","DOI":"10.1021\/acsami.6b05893","article-title":"Tailored Surface Treatment of 3D Printed Porous Ti6Al4V by Microarc Oxidation for Enhanced Osseointegration via Optimized Bone In-Growth Patterns and Interlocked Bone\/Implant Interface","volume":"8","author":"Xiu","year":"2016","journal-title":"ACS Appl. Mater. Interfaces"},{"key":"ref_88","doi-asserted-by":"crossref","first-page":"453","DOI":"10.1002\/jbm.b.35165","article-title":"Novel nano-hydroxyapatite coating of additively manufactured three-dimensional porous implants improves bone ingrowth and initial fixation","volume":"111","author":"Watanabe","year":"2023","journal-title":"J. Biomed. Mater. Res. B Appl. Biomater."},{"key":"ref_89","doi-asserted-by":"crossref","first-page":"10516","DOI":"10.1039\/D4TB01714E","article-title":"Application of advanced surface modification techniques in titanium-based implants: Latest strategies for enhanced antibacterial properties and osseointegration","volume":"12","author":"Yuan","year":"2024","journal-title":"J. Mater. Chem. B"},{"key":"ref_90","doi-asserted-by":"crossref","unstructured":"Sheng, X., Wang, A., Wang, Z., Liu, H., Wang, J., and Li, C. (2022). Advanced Surface Modification for 3D-Printed Titanium Alloy Implant Interface Functionalization. Front. Bioeng. Biotechnol., 10.","DOI":"10.3389\/fbioe.2022.850110"},{"key":"ref_91","doi-asserted-by":"crossref","unstructured":"Jaafar, A., Hecker, C., \u00c1rki, P., and Joseph, Y. (2020). Sol-Gel Derived Hydroxyapatite Coatings for Titanium Implants: A Review. Bioengineering, 7.","DOI":"10.3390\/bioengineering7040127"},{"key":"ref_92","doi-asserted-by":"crossref","unstructured":"Zhang, H., Wu, Z., Wang, Z., Yan, X., Duan, X., and Sun, H. (2025). Advanced surface modification techniques for titanium implants: A review of osteogenic and antibacterial strategies. Front. Bioeng. Biotechnol., 13.","DOI":"10.3389\/fbioe.2025.1549439"},{"key":"ref_93","doi-asserted-by":"crossref","first-page":"1341","DOI":"10.1021\/am201610q","article-title":"Mechanical, In Vitro Antimicrobial, and Biological Properties of Plasma-Sprayed Silver-Doped Hydroxyapatite Coating","volume":"4","author":"Roy","year":"2012","journal-title":"ACS Appl. Mater. Interfaces"},{"key":"ref_94","doi-asserted-by":"crossref","first-page":"226","DOI":"10.1016\/j.msec.2016.01.034","article-title":"A comparative study of zinc, magnesium, strontium-incorporated hydroxyapatite-coated titanium implants for osseointegration of osteopenic rats","volume":"62","author":"Tao","year":"2016","journal-title":"Mater. Sci. Eng. C"},{"key":"ref_95","doi-asserted-by":"crossref","unstructured":"Borgognoni, A.B., Freund, S.S., Baas, J., Bendtsen, M.M., Byskov, J.S., Ranjkesh, B., Nyengaard, J.R., Pauwels, R., Almtoft, K.P., and Baad-Hansen, T. (2026). In-house 3D printed porous implants: Does strontium-coating enhance osseointegration? An in-vivo study in large animals. Front. Surg., 13.","DOI":"10.3389\/fsurg.2026.1818358"},{"key":"ref_96","doi-asserted-by":"crossref","unstructured":"Speijker, L.T.D., Fechter, J., Bargon, R., Dingemans, J., Arts, J.J., Savelkoul, P.H.M., and van Loo, I.H.M. (2025). Silver multilayer coating on orthopedic implant material of different alloys and surfaces significantly reduces bacterial colonization. Front. Cell. Infect. Microbiol., 15.","DOI":"10.3389\/fcimb.2025.1707694"},{"key":"ref_97","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1002\/jbm.820180306","article-title":"In vivo metal-ion release from porous titanium-fiber material","volume":"18","author":"Ducheyne","year":"1984","journal-title":"J. Biomed. Mater. Res."},{"key":"ref_98","doi-asserted-by":"crossref","first-page":"2772","DOI":"10.1097\/CORR.0000000000000954","article-title":"Partially Melted Ti6Al4V Particles Increase Bacterial Adhesion and Inhibit Osteogenic Activity on 3D-printed Implants: An In Vitro Study","volume":"477","author":"Xie","year":"2019","journal-title":"Clin. Orthop. Relat. Res."},{"key":"ref_99","doi-asserted-by":"crossref","first-page":"750","DOI":"10.1177\/10711007221077113","article-title":"Outcomes of Surgical Reconstruction Using Custom 3D-Printed Porous Titanium Implants for Critical-Sized Bone Defects of the Foot and Ankle","volume":"43","author":"Abar","year":"2022","journal-title":"Foot Ankle Int."},{"key":"ref_100","doi-asserted-by":"crossref","first-page":"1004","DOI":"10.1111\/os.13250","article-title":"Reconstruction of Paprosky Type III Acetabular Defects by Three-Dimensional Printed Porous Augment: Techniques and Clinical Outcomes of 18 Consecutive Cases","volume":"14","author":"Fu","year":"2022","journal-title":"Orthop. Surg."},{"key":"ref_101","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1186\/s41205-025-00293-8","article-title":"Custom 3D-printed porous titanium augments for Paprosky type III acetabular defects: A case series combining biomechanical rationale with early clinical outcomes","volume":"11","author":"Shi","year":"2025","journal-title":"3D Print. Med."},{"key":"ref_102","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1016\/j.jor.2026.03.005","article-title":"Survivorship of a contemporary highly porous titanium hemispherical acetabular cup in primary and revision total hip arthroplasty","volume":"76","author":"Bornes","year":"2026","journal-title":"J. Orthop."},{"key":"ref_103","doi-asserted-by":"crossref","first-page":"817","DOI":"10.1111\/os.12846","article-title":"Minimum 7-year Follow-up of A Porous Coated Trabecular Titanium Cup Manufactured with Electron Beam Melting Technique in Primary Total Hip Arthroplasty","volume":"13","author":"Huang","year":"2021","journal-title":"Orthop. Surg."},{"key":"ref_104","doi-asserted-by":"crossref","first-page":"341","DOI":"10.1177\/21925682251344557","article-title":"3D-Printed Titanium Cages for Anterior and Lateral Lumbar Interbody Fusion Result in Excellent Fusion Rates One Year After Surgery","volume":"16","author":"Calek","year":"2026","journal-title":"Glob. Spine J."},{"key":"ref_105","doi-asserted-by":"crossref","first-page":"3067","DOI":"10.1111\/os.70159","article-title":"Clinical Application of 3D-Printed Custom Hemipelvic Prostheses With Re-Entrant Chiral Structure in Reconstruction After Pelvic Tumor Resection","volume":"17","author":"Tan","year":"2025","journal-title":"Orthop. Surg."},{"key":"ref_106","doi-asserted-by":"crossref","unstructured":"Yon, C.-J., Choi, B.-C., Lee, J.-M., and Lee, S.-W. (2025). Personalized 3D-Printed Prostheses for Bone Defect Reconstruction After Tumor Resection in the Foot and Ankle. J. Funct. Biomater., 16.","DOI":"10.3390\/jfb16020062"},{"key":"ref_107","doi-asserted-by":"crossref","first-page":"96","DOI":"10.1007\/s00590-025-04229-0","article-title":"Utilizing 3D-printed patient-specific porous titanium cones in complex primary and revision total knee arthroplasty","volume":"35","author":"Moradkhani","year":"2025","journal-title":"Eur. J. Orthop. Surg. Traumatol."},{"key":"ref_108","doi-asserted-by":"crossref","unstructured":"Feldman, A., Assad, M., Davies, M.B., Mangwani, J., Alabort, E., and Tuncer, M. (2024). Cortico-cancellous osseointegration into additively manufactured titanium implants using a load-bearing femoral ovine model. Front. Bioeng. Biotechnol., 12.","DOI":"10.3389\/fbioe.2024.1371693"},{"key":"ref_109","doi-asserted-by":"crossref","first-page":"1003","DOI":"10.1177\/0885328211431857","article-title":"Long-term biocompatibility and osseointegration of electron beam melted, free-form-fabricated solid and porous titanium alloy: Experimental studies in sheep","volume":"27","author":"Palmquist","year":"2013","journal-title":"J. Biomater. Appl."},{"key":"ref_110","first-page":"94","article-title":"Early osteointegration evaluation of porous Ti6Al4V scaffolds designed based on triply periodic minimal surface models","volume":"19","author":"Li","year":"2019","journal-title":"J. Orthop. Transl."},{"key":"ref_111","doi-asserted-by":"crossref","first-page":"531","DOI":"10.3109\/17453670903316801","article-title":"Female patients with low systemic BMD are prone to bone loss in Gruen zone 7 after cementless total hip arthroplasty","volume":"80","author":"Alm","year":"2009","journal-title":"Acta Orthop."},{"key":"ref_112","doi-asserted-by":"crossref","first-page":"26","DOI":"10.5301\/hipint.5000413","article-title":"Periprosthetic femoral bone loss in total hip arthroplasty: Systematic analysis of the effect of stem design","volume":"27","author":"Knutsen","year":"2017","journal-title":"Hip Int."},{"key":"ref_113","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1097\/01.blo.0000096825.67494.e3","article-title":"Clinical consequences of stress shielding after porous-coated total hip arthroplasty","volume":"417","author":"Engh","year":"2003","journal-title":"Clin. Orthop. Relat. Res."},{"key":"ref_114","doi-asserted-by":"crossref","first-page":"231","DOI":"10.21037\/atm-20-4043","article-title":"A comparison of short-stem prostheses and conventional stem prostheses in primary total hip arthroplasty: A systematic review and meta-analysis of randomized controlled trials","volume":"9","author":"Zhang","year":"2021","journal-title":"Ann. Transl. Med."},{"key":"ref_115","doi-asserted-by":"crossref","first-page":"e8806","DOI":"10.1097\/MD.0000000000008806","article-title":"Periprosthetic bone remodeling of short cementless femoral stems in primary total hip arthroplasty","volume":"96","author":"Yan","year":"2017","journal-title":"Medicine"},{"key":"ref_116","doi-asserted-by":"crossref","first-page":"101067","DOI":"10.1016\/j.artd.2022.10.017","article-title":"Case Series of Silver Oxide\u2013Containing Hydroxyapatite Coating in Antibacterial Cementless Total Hip Arthroplasty: Clinical Results of 50 Cases at 5-Year Follow-Up","volume":"19","author":"Kawano","year":"2023","journal-title":"Arthroplast. Today"},{"key":"ref_117","doi-asserted-by":"crossref","first-page":"201","DOI":"10.1007\/s00590-020-02779-z","article-title":"Silver-coated megaprosthesis in prevention and treatment of peri-prosthetic infections: A systematic review and meta-analysis about efficacy and toxicity in primary and revision surgery","volume":"31","author":"Fiore","year":"2021","journal-title":"Eur. J. Orthop. Surg. Traumatol."},{"key":"ref_118","doi-asserted-by":"crossref","first-page":"905","DOI":"10.1177\/11207000221135068","article-title":"Custom designed and 3D-printed titanium pelvic implants for acetabular reconstruction after tumour resection","volume":"33","author":"Broekhuis","year":"2023","journal-title":"Hip Int."},{"key":"ref_119","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1177\/1120700020918233","article-title":"How do 3D-printed primary uncemented acetabular components compare with established uncemented acetabular cups? The experience of the New Zealand National Joint Registry","volume":"32","author":"Wyatt","year":"2022","journal-title":"Hip Int."},{"key":"ref_120","doi-asserted-by":"crossref","first-page":"78","DOI":"10.2106\/JBJS.F.01495","article-title":"Use of porous tantalum metaphyseal cones for severe tibial bone loss during revision total knee replacement","volume":"90","author":"Meneghini","year":"2008","journal-title":"J. Bone Jt. Surg. Am."},{"key":"ref_121","doi-asserted-by":"crossref","first-page":"12","DOI":"10.3928\/01477447-20101123-08","article-title":"The Harris-Galante Cementless THA: A 19- to 25-Year Follow-Up Study","volume":"34","author":"Saito","year":"2011","journal-title":"Orthopedics"},{"key":"ref_122","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1007\/s00264-010-1117-2","article-title":"Twenty-year results of the cementless Corail stem","volume":"35","author":"Vidalain","year":"2011","journal-title":"Int. Orthop."},{"key":"ref_123","doi-asserted-by":"crossref","first-page":"259","DOI":"10.1080\/17453674.2018.1431445","article-title":"Trabecular metal acetabular components in primary total hip arthroplasty: Higher risk for revision compared with other uncemented cup designs in a collaborative register study including 93,709 hips","volume":"89","author":"Laaksonen","year":"2018","journal-title":"Acta Orthop."},{"key":"ref_124","doi-asserted-by":"crossref","unstructured":"Velluto, C., Mundis, G., Scaramuzzo, L., Perna, A., Capece, G., Cruciani, A., Inverso, M., Borruto, M.I., and Proietti, L. (2024). Radiological evaluation of fusion patterns after lateral lumbar interbody fusion with 3D-printed porous titanium cages vs. conventional titanium cages. Front. Surg., 11.","DOI":"10.3389\/fsurg.2024.1446792"},{"key":"ref_125","doi-asserted-by":"crossref","first-page":"4845","DOI":"10.1016\/j.biomaterials.2007.07.013","article-title":"PEEK biomaterials in trauma, orthopedic, and spinal implants","volume":"28","author":"Kurtz","year":"2007","journal-title":"Biomaterials"},{"key":"ref_126","doi-asserted-by":"crossref","unstructured":"Wei, Z., Zhang, Z., Zhu, W., and Weng, X. (2023). Polyetheretherketone development in bone tissue engineering and orthopedic surgery. Front. Bioeng. Biotechnol., 11.","DOI":"10.3389\/fbioe.2023.1207277"},{"key":"ref_127","doi-asserted-by":"crossref","unstructured":"Liu, S.-X., Zeng, T.-H., Chen, C.-M., He, L.-R., Feng, A.-P., Jhang, S.-W., and Lin, G.-X. (2024). 3D-printed porous titanium versus polyetheretherketone cages in lateral lumbar interbody fusion: A systematic review and meta-analysis of subsidence. Front. Med., 11.","DOI":"10.3389\/fmed.2024.1389533"},{"key":"ref_128","doi-asserted-by":"crossref","first-page":"290","DOI":"10.3892\/etm.2024.12579","article-title":"Application of 3D-printed porous titanium interbody fusion cage vs. polyether ether ketone interbody fusion cage in anterior cervical discectomy and fusion: A systematic review and meta-analysis update","volume":"28","author":"Zhai","year":"2024","journal-title":"Exp. Ther. Med."},{"key":"#cr-split#-ref_129.1","unstructured":"European Parliament, and Council of the European Union (2017). Regulation"},{"key":"#cr-split#-ref_129.2","unstructured":"(EU) 2017\/745 of the European Parliament and of the Council of 5 April 2017 on Medical Devices. Off. J. Eur. Union, L 117, 1-175."},{"key":"ref_130","unstructured":"(2021). Questions and Answers on Custom-Made Devices (Standard No. MDCG 2021-3)."},{"key":"ref_131","doi-asserted-by":"crossref","first-page":"e163","DOI":"10.1016\/S2589-7500(19)30067-6","article-title":"Challenges in the design and regulatory approval of 3D-printed surgical implants: A two-case series","volume":"1","author":"Willemsen","year":"2019","journal-title":"Lancet Digit. Health"},{"key":"ref_132","doi-asserted-by":"crossref","first-page":"146","DOI":"10.1016\/j.eng.2024.01.028","article-title":"Process, Material, and Regulatory Considerations for 3D Printed Medical Devices and Tissue Constructs","volume":"36","author":"Ng","year":"2024","journal-title":"Engineering"},{"key":"ref_133","doi-asserted-by":"crossref","unstructured":"Markovi\u0107, G., Manojlovi\u0107, V., Ru\u017ei\u0107, J., and Soki\u0107, M. (2023). Predicting Low-Modulus Biocompatible Titanium Alloys Using Machine Learning. Materials, 16.","DOI":"10.3390\/ma16196355"}],"container-title":["Materials"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1996-1944\/19\/18\/3860\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,12]],"date-time":"2026-09-12T04:19:07Z","timestamp":1789186747000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1996-1944\/19\/18\/3860"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,10]]},"references-count":134,"journal-issue":{"issue":"18","published-online":{"date-parts":[[2026,9]]}},"alternative-id":["ma19183860"],"URL":"https:\/\/doi.org\/10.3390\/ma19183860","relation":{},"ISSN":["1996-1944"],"issn-type":[{"value":"1996-1944","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,10]]}}}