{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,23]],"date-time":"2026-09-23T09:04:32Z","timestamp":1790154272795,"version":"4.0.1"},"reference-count":42,"publisher":"MDPI AG","issue":"19","license":[{"start":{"date-parts":[[2026,9,23]],"date-time":"2026-09-23T00:00:00Z","timestamp":1790121600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100006595","name":"Ministry of Research, Innovation and Digitalization","doi-asserted-by":"publisher","award":["PN-IV-P2-2.1-TE-2023-1086"],"award-info":[{"award-number":["PN-IV-P2-2.1-TE-2023-1086"]}],"id":[{"id":"10.13039\/501100006595","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Materials"],"abstract":"<jats:p>Ti6Al4V remains one of the most widely used metallic biomaterials for orthopedic and dental implants; however, the long-term performance of implantable devices is strongly influenced by the mechanical integrity and surface stability of the implant\u2013tissue interface. In this study, novel phosphate conversion coatings based on Zn\u2013Mg\u2013Ca, Zn\u2013Zr\u2013Mg, and Zn\u2013Zr\u2013Ca systems were developed on Ti6Al4V substrates through a chemical conversion process and investigated from a tribomechanical perspective. The coatings were designed to incorporate biologically relevant elements capable of modifying crystal growth, coating compactness and interfacial characteristics. Surface morphology, coating architecture and elemental distribution were evaluated using scanning electron microscopy and energy-dispersive spectroscopy, while surface roughness was determined by profilometry. The mechanical response of the conversion-modified surfaces was assessed through instrumented microindentation and progressive-load scratch testing coupled with acoustic emission monitoring. Significant differences in coating morphology, thickness and compactness were observed as a function of phosphating chemistry. Dense and homogeneous coatings exhibited improved hardness, higher elastic recovery and enhanced resistance to plastic deformation, whereas heterogeneous structures containing large intergranular regions showed inferior mechanical performance. Scratch testing demonstrated that coating composition strongly influences damage initiation, interfacial stability and resistance to coating detachment. Among the investigated systems, Zn\u2013Zr\u2013Ca and selected Zn\u2013Zr\u2013Mg formulations provided the most favorable combination of compact microstructure, mechanical integrity and scratch resistance. The results establish clear relationships between phosphating chemistry, coating architecture and tribomechanical behavior, providing valuable insight for the design of conversion-treated Ti6Al4V surfaces intended for biomedical implant applications.<\/jats:p>","DOI":"10.3390\/ma19194058","type":"journal-article","created":{"date-parts":[[2026,9,23]],"date-time":"2026-09-23T08:14:39Z","timestamp":1790151279000},"page":"4058","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Microstructure, Adhesion and Tribomechanical Performance of Zn\u2013Mg\u2013Ca- and Zn\u2013Zr-Based Phosphate Conversion Coatings on Ti6Al4V Alloy"],"prefix":"10.3390","volume":"19","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-0680-9885","authenticated-orcid":false,"given":"Diana-Petronela","family":"Burduhos-Nergis","sequence":"first","affiliation":[{"name":"Faculty of Material Science and Engineering, Gheorghe Asachi Technical University of Iasi, 41, Prof. Dr. doc. D. Mangeron str., 700050 Iasi, Romania"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3078-6553","authenticated-orcid":false,"given":"Nicoleta-Monica","family":"Lohan","sequence":"additional","affiliation":[{"name":"Faculty of Material Science and Engineering, Gheorghe Asachi Technical University of Iasi, 41, Prof. Dr. doc. D. Mangeron str., 700050 Iasi, Romania"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elena","family":"Matcovschi","sequence":"additional","affiliation":[{"name":"Faculty of Material Science and Engineering, Gheorghe Asachi Technical University of Iasi, 41, Prof. Dr. doc. D. Mangeron str., 700050 Iasi, Romania"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4233-5231","authenticated-orcid":false,"given":"Gheorghe","family":"Badarau","sequence":"additional","affiliation":[{"name":"Faculty of Material Science and Engineering, Gheorghe Asachi Technical University of Iasi, 41, Prof. Dr. doc. D. Mangeron str., 700050 Iasi, Romania"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1973-7240","authenticated-orcid":false,"given":"Costica","family":"Bejinariu","sequence":"additional","affiliation":[{"name":"Faculty of Material Science and Engineering, Gheorghe Asachi Technical University of Iasi, 41, Prof. Dr. doc. D. Mangeron str., 700050 Iasi, Romania"},{"name":"Academy of Romanian Scientists, Ilfov 3, 050044 Bucharest, Romania"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9961-5125","authenticated-orcid":false,"given":"Marcelin","family":"Benchea","sequence":"additional","affiliation":[{"name":"Faculty of Mechanical Engineering, Gheorghe Asachi Technical University of Iasi, 61-63, Prof. Dr. doc. D. Mangeron str., 700050 Iasi, Romania"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0009-6872-8616","authenticated-orcid":false,"given":"Fabian-Cezar","family":"Lupu","sequence":"additional","affiliation":[{"name":"Faculty of Mechanical Engineering, Gheorghe Asachi Technical University of Iasi, 61-63, Prof. Dr. doc. D. Mangeron str., 700050 Iasi, Romania"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nicanor","family":"Cimpoesu","sequence":"additional","affiliation":[{"name":"Faculty of Material Science and Engineering, Gheorghe Asachi Technical University of Iasi, 41, Prof. Dr. doc. D. Mangeron str., 700050 Iasi, Romania"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2026,9,23]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","unstructured":"Jung, H.-D. (2021). Titanium and Its Alloys for Biomedical Applications. Metals, 11.","DOI":"10.3390\/met11121945"},{"key":"ref_2","doi-asserted-by":"crossref","unstructured":"Marin, E., and Lanzutti, A. (2024). Biomedical Applications of Titanium Alloys: A Comprehensive Review. Materials, 17.","DOI":"10.3390\/ma17010114"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"156","DOI":"10.1016\/j.apsusc.2013.01.154","article-title":"Microstructural evolution during nitriding, finite element simulation and experimental assessment","volume":"271","author":"Guagliano","year":"2013","journal-title":"Appl. Surf. Sci."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"578","DOI":"10.1016\/j.apsusc.2013.05.030","article-title":"Physical vapor deposited titanium thin films for biomedical applications: Reproducibility of nanoscale surface roughness and microbial adhesion properties","volume":"280","author":"Bossert","year":"2013","journal-title":"Appl. Surf. Sci."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"4462","DOI":"10.1007\/s11665-015-1732-6","article-title":"The Tribological Behaviors of Three Films Coated on Biomedical Titanium Alloy by Chemical Vapor Deposition","volume":"24","author":"Wang","year":"2015","journal-title":"J. Mater. Eng. Perform."},{"key":"ref_6","doi-asserted-by":"crossref","unstructured":"Schwartz, A., Kossenko, A., Zinigrad, M., Gofer, Y., Borodianskiy, K., and Sobolev, A. (2022). Hydroxyapatite Coating on Ti-6Al-7Nb Alloy by Plasma Electrolytic Oxidation in Salt-Based Electrolyte. Materials, 15.","DOI":"10.3390\/ma15207374"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"4441","DOI":"10.1007\/s10853-015-9013-1","article-title":"Cold spray as an emerging technology for biocompatible and antibacterial coatings: State of art","volume":"50","author":"Vilardell","year":"2015","journal-title":"J. Mater. Sci."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1016\/j.surfcoat.2018.05.068","article-title":"Magnetron-sputtered Ti\u2093N\u1d67 thin films applied on titanium-based alloys for biomedical applications: Composition-microstructure-property relationships","volume":"349","author":"Nemati","year":"2018","journal-title":"Surf. Coat. Technol."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"127","DOI":"10.1016\/j.matpr.2020.11.1023","article-title":"Sol gel deposited hydroxyapatite-based coating technique on porous titanium niobium for biomedical applications: A mini review","volume":"41","author":"Mohammad","year":"2021","journal-title":"Mater. Today Proc."},{"key":"ref_10","doi-asserted-by":"crossref","unstructured":"Abakay, E., Arma\u011fan, M., Y\u0131ld\u0131ran Avcu, Y., Guney, M., Yousif, B.F., and Avcu, E. (2024). Advances in improving tribological performance of titanium alloys and titanium matrix composites for biomedical applications: A critical review. Front. Mater., 11.","DOI":"10.3389\/fmats.2024.1452288"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"146","DOI":"10.1007\/s43452-024-00960-3","article-title":"The influence of laser texturing on the tribological behavior of titanium alloy Ti6Al4V in medical applications","volume":"24","author":"Bialas","year":"2024","journal-title":"Arch. Civ. Mech. Eng."},{"key":"ref_12","first-page":"41","article-title":"On PVD coating technique for tribological, bio-compatibility, and corrosion behavior of Ti-based alloys using biomedical applications: A review","volume":"3","author":"Godwin","year":"2024","journal-title":"J. Mater. Manuf."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"e70000","DOI":"10.1049\/bsb2.70000","article-title":"Friction and Wear Characteristics of Micro-Arc Oxidation Coating on Ti6Al4V Alloy\u2014A Review","volume":"11","author":"Qin","year":"2025","journal-title":"Biosurf. Biotribol."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1007\/s40735-023-00805-1","article-title":"Effect of Coatings on Mechanical, Corrosion and Tribological Properties of Industrial Materials: A Comprehensive Review","volume":"10","author":"Okokpujie","year":"2024","journal-title":"J. Bio-Tribo-Corros."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"1435","DOI":"10.1007\/s12613-022-2419-2","article-title":"Review on the phosphate-based conversion coatings of magnesium and its alloys","volume":"29","author":"Saran","year":"2022","journal-title":"Int. J. Miner. Metall. Mater."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"97","DOI":"10.1016\/j.msec.2014.11.038","article-title":"Phosphate chemical conversion coatings on metallic substrates for biomedical application: A review","volume":"47","author":"Liu","year":"2015","journal-title":"Mater. Sci. Eng. C"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"127362","DOI":"10.1016\/j.cej.2020.127362","article-title":"Strontium-zinc phosphate chemical conversion coating improves the osseointegration of titanium implants by regulating macrophage polarization","volume":"408","author":"Zhao","year":"2021","journal-title":"Chem. Eng. J."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"107884","DOI":"10.1016\/j.surfin.2025.107884","article-title":"Micromorphology and properties of novel phosphate conversion coatings based on zinc-magnesium and zinc-zirconium deposited on Ti6Al4V","volume":"76","author":"Munteanu","year":"2025","journal-title":"Surf. Interfaces"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"107894","DOI":"10.1016\/j.triboint.2022.107894","article-title":"Effect of coating thickness on tribological properties of manganese phosphate conversion coating in different motion conditions","volume":"176","author":"Zang","year":"2022","journal-title":"Tribol. Int."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"203427","DOI":"10.1016\/j.wear.2020.203427","article-title":"Comparative tribological and friction behaviors of oil-lubricated manganese phosphate conversion coatings with different crystal sizes on AISI 52100 steel","volume":"458\u2013459","author":"Zang","year":"2020","journal-title":"Wear"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"106122","DOI":"10.1016\/j.triboint.2019.106122","article-title":"Study of tribological and friction behavior of magnesium phosphate coating and comparison with traditional zinc phosphate coating under dry and lubricated conditions","volume":"144","author":"Saffarzade","year":"2020","journal-title":"Tribol. Int."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"479","DOI":"10.1007\/s10008-023-05681-w","article-title":"A poly(methyl methacrylate)\u2013ibuprofen composite film as anticorrosive coating of Ti\u20136Al\u20134 V surface","volume":"28","author":"Cotolan","year":"2024","journal-title":"J. Solid State Electrochem."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1007\/978-3-032-08769-0_4","article-title":"Tribological Characterization of Zn-Zr-Sr Conversion Coatings Deposited on Ti6Al4V","volume":"Volume 95","author":"Sandu","year":"2025","journal-title":"Selected Papers from ICIR EUROINVENT\u20142025"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1016\/j.vacuum.2017.09.024","article-title":"Improvement of the mechanical behavior of the calcium phosphate coatings deposited onto Ti6Al4V alloy using an intermediate TiN\/TiO2 bilayer","volume":"146","author":"Quirama","year":"2017","journal-title":"Vacuum"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"563","DOI":"10.1016\/j.ceramint.2013.06.038","article-title":"Calcium phosphate coatings: Morphology, micro-structure and mechanical properties","volume":"40","author":"Alamara","year":"2014","journal-title":"Ceram. Int."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"12137","DOI":"10.1016\/j.ceramint.2015.06.031","article-title":"Elastic modulus of a chemically bonded phosphate ceramic formulated with low-grade magnesium oxide determined by Nanoindentation","volume":"41","author":"Morales","year":"2015","journal-title":"Ceram. Int."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"1739","DOI":"10.1016\/j.jmrt.2021.07.091","article-title":"Influence of indentation size on the corrosion behaviour of a phosphate conversion coated AZ80 magnesium alloy","volume":"14","author":"Jia","year":"2021","journal-title":"J. Mater. Res. Technol."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"3414","DOI":"10.1016\/j.jbiomech.2008.09.018","article-title":"Micromechanical evaluation of mineralized multilayers","volume":"41","author":"Shibata","year":"2008","journal-title":"J. Biomech."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"3563","DOI":"10.1016\/j.actbio.2009.05.013","article-title":"Deposition and investigation of functionally graded calcium phosphate coatings on titanium","volume":"5","author":"Bai","year":"2009","journal-title":"Acta Biomater."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"104","DOI":"10.1016\/j.colsurfb.2017.05.016","article-title":"Incorporation of silver nanoparticles into magnetron-sputtered calcium phosphate layers on titanium as an antibacterial coating","volume":"156","author":"Surmeneva","year":"2017","journal-title":"Colloids Surf. B Biointerfaces"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"474","DOI":"10.1016\/j.triboint.2017.04.034","article-title":"Mechanical characterization and single asperity scratch behaviour of dry zinc and manganese phosphate coatings","volume":"118","author":"Ernens","year":"2018","journal-title":"Tribol. Int."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"324","DOI":"10.1016\/j.jmbbm.2010.01.002","article-title":"Adhesion failure behavior of sputtered calcium phosphate thin film coatings evaluated using microscratch testing","volume":"3","author":"Toque","year":"2010","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"111238","DOI":"10.1016\/j.msec.2020.111238","article-title":"The mechanical and chemical stability of the interfaces in bioactive materials: The substrate-bioactive surface layer and hydroxyapatite-bioactive surface layer interfaces","volume":"116","author":"Ferraris","year":"2020","journal-title":"Mater. Sci. Eng. C"},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"158701","DOI":"10.1016\/j.jallcom.2021.158701","article-title":"Preparation of phosphate conversion coating on laser surface textured surface to improve corrosion performance of magnesium alloy","volume":"865","author":"Liu","year":"2021","journal-title":"J. Alloys Compd."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"605","DOI":"10.1016\/j.apsusc.2017.04.110","article-title":"Mechanical, structural and dissolution properties of heat treated thin-film phosphate based glasses","volume":"416","author":"Stuart","year":"2017","journal-title":"Appl. Surf. Sci."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1016\/j.biomaterials.2004.02.033","article-title":"In vitro biological effects of titanium rough surface obtained by calcium phosphate grid blasting","volume":"26","author":"Citeau","year":"2005","journal-title":"Biomaterials"},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"296","DOI":"10.1034\/j.1600-0501.2000.011004296.x","article-title":"Effect of surface roughness and calcium phosphate coating on the implant\/bone response","volume":"11","author":"Hayakawa","year":"2000","journal-title":"Clin. Oral Implant. Res."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"667","DOI":"10.1002\/jbm.a.32000","article-title":"Effect of surface roughness, porosity, and a resorbable calcium phosphate coating on osseointegration of titanium in a minipig model","volume":"89A","author":"Schwarz","year":"2009","journal-title":"J. Biomed. Mater. Res. A"},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"203180","DOI":"10.1016\/j.wear.2019.203180","article-title":"Influence of surface roughness and phosphate coating on galling resistance of medium-grade carbon steel","volume":"446\u2013447","author":"Podgornik","year":"2020","journal-title":"Wear"},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"130260","DOI":"10.1016\/j.surfcoat.2023.130260","article-title":"A comprehensive structural and electrochemical study on the performance of Mn-phosphate layers","volume":"476","author":"Figueroa","year":"2024","journal-title":"Surf. Coat. Technol."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"5369","DOI":"10.1016\/j.actbio.2012.10.009","article-title":"Moisture based three-dimensional printing of calcium phosphate structures for scaffold engineering","volume":"9","author":"Butscher","year":"2013","journal-title":"Acta Biomater."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"128","DOI":"10.1016\/j.jmbbm.2011.10.010","article-title":"Using scratch testing to measure the adhesion strength of calcium phosphate coatings applied to poly(carbonate urethane) substrates","volume":"6","author":"Barnes","year":"2012","journal-title":"J. Mech. Behav. Biomed. Mater."}],"container-title":["Materials"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1996-1944\/19\/19\/4058\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,23]],"date-time":"2026-09-23T08:23:57Z","timestamp":1790151837000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1996-1944\/19\/19\/4058"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,23]]},"references-count":42,"journal-issue":{"issue":"19","published-online":{"date-parts":[[2026,10]]}},"alternative-id":["ma19194058"],"URL":"https:\/\/doi.org\/10.3390\/ma19194058","relation":{},"ISSN":["1996-1944"],"issn-type":[{"value":"1996-1944","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,23]]}}}