{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,7]],"date-time":"2026-05-07T22:17:21Z","timestamp":1778192241385,"version":"3.51.4"},"reference-count":20,"publisher":"MDPI AG","issue":"11","license":[{"start":{"date-parts":[[2016,10,26]],"date-time":"2016-10-26T00:00:00Z","timestamp":1477440000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["51375272"],"award-info":[{"award-number":["51375272"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100004543","name":"China Scholarship Council","doi-asserted-by":"publisher","award":["CSC-201506220078"],"award-info":[{"award-number":["CSC-201506220078"]}],"id":[{"id":"10.13039\/501100004543","id-type":"DOI","asserted-by":"publisher"}]},{"name":"Talent Plan for Middle School Students"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Materials"],"abstract":"<jats:p>Titanium and its alloys have been widely used as implant materials due to their excellent mechanical property and biocompatibility. In the present study, the effect of glucose concentration on corrosion behavior of pure titanium TA2 in Hanks\u2019 simulated body fluid is investigated by the electrochemical impedance spectrum (EIS) and potentiodynamic polarization methods. The range of glucose concentrations investigated in this research includes 5 mmol\/L (limosis for healthy people), 7 mmol\/L (after diet for healthy people), 10 mmol\/L (limosis for hyperglycemia patient), and 12 mmol\/L (after diet for hyperglycemia patient), as well as, 15 mmol\/L and 20 mmol\/L, which represent different body fluid environments. The results indicate that the pure titanium TA2 demonstrates the best corrosion resistance when the glucose concentration is less than 10 mmol\/L, which shows that the pure titanium TA2 as implant material can play an effective role in the body fluids with normal and slight high glucose concentrations. Comparatively, the corrosion for the pure titanium implant is more probable when the glucose concentration is over 10 mmol\/L due to the premature penetration through passive film on the material surface. Corrosion defects of pitting and crevice exist on the corroded surface, and the depth of corrosion is limited to three microns with a low corrosion rate. The oxidation film on the surface of pure titanium TA2 has a protective effect on the corrosion behavior of the implant inner material. The corrosion behavior of pure titanium TA2 will happen easily once the passive film has been penetrated through. The corrosion rate for TA2 implant will accelerate quickly and a pure titanium implant cannot be used.<\/jats:p>","DOI":"10.3390\/ma9110874","type":"journal-article","created":{"date-parts":[[2016,10,26]],"date-time":"2016-10-26T10:12:01Z","timestamp":1477476721000},"page":"874","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":12,"title":["Effect of Glucose Concentration on Electrochemical Corrosion Behavior of Pure Titanium TA2 in Hanks\u2019 Simulated Body Fluid"],"prefix":"10.3390","volume":"9","author":[{"given":"Shuyue","family":"Liu","sequence":"first","affiliation":[{"name":"High School Attached to Shandong Normal University, Jinan 250014, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3662-7625","authenticated-orcid":false,"given":"Bing","family":"Wang","sequence":"additional","affiliation":[{"name":"Key Laboratory of High Efficiency and Clean Mechanical Manufacture of MOE, School of Mechanical Engineering, Shandong University, Jinan 250061, China"},{"name":"Department of Mechanical Engineering, Michigan State University, Lansing, MI 48910, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Peirong","family":"Zhang","sequence":"additional","affiliation":[{"name":"Key Laboratory of High Efficiency and Clean Mechanical Manufacture of MOE, School of Mechanical Engineering, Shandong University, Jinan 250061, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2016,10,26]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"262","DOI":"10.1016\/S0924-0136(96)00030-1","article-title":"Titanium alloys and their machinability\u2014A review","volume":"68","author":"Ezugwu","year":"1997","journal-title":"J. Mater. Process. Technol."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"268","DOI":"10.1016\/j.msec.2016.01.065","article-title":"Influence of sulfide concentration on the corrosion behavior of titanium in a artificial oral environment","volume":"62","author":"Harada","year":"2016","journal-title":"Mater. Sci. Eng. C"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"130","DOI":"10.1016\/j.tsf.2012.06.088","article-title":"Corrosion resistance and biocompatibility of titanium surface coated with amorphous tantalum pentoxide","volume":"528","author":"Sun","year":"2013","journal-title":"Thin Solid Films"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1016\/j.jcis.2016.02.022","article-title":"Titanium dental implants surface-immobilized with gold nanoparticles as osteoinductive agents for rapid osseointegration","volume":"469","author":"Heo","year":"2016","journal-title":"J. Colloid Interface Sci."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"648","DOI":"10.1016\/j.colsurfb.2011.07.054","article-title":"Electrochemically induced anatase inhibits bacterial colonization on Titanium Grade 2 and Ti6Al4V alloy for dental and orthopedic devices","volume":"88","author":"Giordano","year":"2011","journal-title":"Colloids Surf. B Biointerfaces"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"181","DOI":"10.1533\/9780857092205.181","article-title":"Application of biomedical-grade titanium alloys in trabecular bone and artificial joints","volume":"1","author":"Luo","year":"2013","journal-title":"Biomater. Med. Tribol."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1016\/j.msec.2015.03.015","article-title":"Elastic properties of a porous titanium-bone tissue composite","volume":"52","author":"Rubshtein","year":"2015","journal-title":"Mater. Sci. Eng. C"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"132","DOI":"10.1016\/j.jmbbm.2015.02.001","article-title":"Microstructure, elastic deformation behavior and mechanical properties of biomedical \u03b2-type titanium alloy thin-tube used for stents","volume":"45","author":"Tian","year":"2015","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"288","DOI":"10.1016\/j.jallcom.2004.03.096","article-title":"Effect of replacement of V by Nb and Fe on the electrochemical and corrosion behavior of Ti-6Al-4V in simulated physiological environment","volume":"381","author":"Choubey","year":"2004","journal-title":"J. Alloys Comp."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"796","DOI":"10.1016\/j.corsci.2010.11.014","article-title":"Wear and corrosion behaviour of Ti-13Nb-13Zr and Ti-6Al-4V alloys in simulated physiological solution","volume":"53","author":"Rakin","year":"2011","journal-title":"Corros. Sci."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"960","DOI":"10.1016\/j.msec.2016.01.032","article-title":"Commercially pure titanium (cp-Ti) versus titanium alloy (Ti6Al4V) materials as bone anchored implants\u2014Is one truly better than the other?","volume":"62","author":"Shah","year":"2016","journal-title":"Mater. Sci. Eng. C"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"114","DOI":"10.1016\/j.matchar.2006.03.020","article-title":"Titanium oxide films produced on commercially pure titanium by anodic oxidation with different voltages","volume":"58","author":"Kuromoto","year":"2007","journal-title":"Mater. Charact."},{"key":"ref_13","first-page":"34","article-title":"Corrosion in titanium dental implants\/prostheses\u2014A review","volume":"25","author":"Bhola","year":"2011","journal-title":"Trends Biomater. Artif. Organs"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"53","DOI":"10.2298\/JMMB150129003K","article-title":"Comparison of the corrosion behavior and surface morphology of NiTi alloy and stainless steels in sodium chloride solution","volume":"52","author":"Kosec","year":"2016","journal-title":"J. Min. Metall. B. Metall."},{"key":"ref_15","first-page":"252","article-title":"Simplified technique without skin flap for the bone-anchored hearing aid (BAHA) implant","volume":"28","author":"Bovo","year":"2008","journal-title":"Acta Otorhinolaryngol. Ital."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"853072","DOI":"10.1155\/2015\/853072","article-title":"Stability testing of a wide bone-anchored device after surgery without skin thinning","volume":"2015","author":"Hultcrantz","year":"2015","journal-title":"BioMed Res. Int."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"311","DOI":"10.1302\/0301-620X.79B2.0790311","article-title":"In vitro human monocyte response to wear particles of titanium alloy containing vanadium or niobium","volume":"79","author":"Rogers","year":"1997","journal-title":"J. Bone Jt. Surg. Br."},{"key":"ref_18","unstructured":"Ruhl, J. (2008). Blood Sugar 101: What They Don\u2019t Tell You about Diabetes, Technion Books."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"20909","DOI":"10.1038\/srep20909","article-title":"Progranulin suppresses titanium particle induced inflammatory osteolysis by targeting TNF\u03b1 signaling","volume":"6","author":"Zhao","year":"2016","journal-title":"Sci. Rep."},{"key":"ref_20","first-page":"5","article-title":"Specific material effects of wear-particle-induced inflammation and osteolysis at the bone\u2013implant interface: A rat model","volume":"8","author":"Longhofer","year":"2017","journal-title":"J. Orthop. Trans."}],"container-title":["Materials"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1996-1944\/9\/11\/874\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T19:34:03Z","timestamp":1760211243000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1996-1944\/9\/11\/874"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,10,26]]},"references-count":20,"journal-issue":{"issue":"11","published-online":{"date-parts":[[2016,11]]}},"alternative-id":["ma9110874"],"URL":"https:\/\/doi.org\/10.3390\/ma9110874","relation":{},"ISSN":["1996-1944"],"issn-type":[{"value":"1996-1944","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,10,26]]}}}