{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,28]],"date-time":"2026-10-28T03:25:57Z","timestamp":1793157957267,"version":"4.5.0"},"reference-count":19,"publisher":"MDPI AG","issue":"4","license":[{"start":{"date-parts":[[2019,4,5]],"date-time":"2019-04-05T00:00:00Z","timestamp":1554422400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Medicina"],"abstract":"<jats:p>Background and objectives: As the prevalence of obesity is increasing in a population, diagnostics becomes more problematic. Our aim was to compare the 3M Littmann 3200 Electronic Stethoscope and 3M Littman Cardiology III Mechanical Stethoscope in the auscultation of obese patients. Methods. A total of 30 patients with body mass index &gt;30 kg\/m2 were auscultated by a cardiologist and a resident physician: 15 patients by one cardiologist and one resident and 15 patients by another cardiologist and resident using both stethoscopes. In total, 960 auscultation data points were verified by an echocardiogram. Sensitivity and specificity data were calculated. Results. Sensitivity for regurgitation with valves combined was higher when the electronic stethoscope was used by the cardiologist (60.0% vs. 40.9%, p = 0.0002) and the resident physician (62.1% vs. 51.5%, p = 0.016); this was also the same when stenoses were added (59.4% vs. 40.6%, p = 0.0002, and 60.9% vs. 50.7%, p = 0.016, respectively). For any lesion, there were no significant differences in specificity between the electronic and acoustic stethoscopes for the cardiologist (92.4% vs. 94.2%) and the resident physician (93.6% vs. 94.7%). The detailed analysis by valve showed one significant difference in regurgitation at the mitral valve for the cardiologist (80.0% vs. 56.0%, p = 0.031). No significant difference in specificity between the stethoscopes was found when all lesions, valves and both physicians were combined (93.0% vs. 94.4%, p = 0.30), but the electronic stethoscope had higher sensitivity than the acoustic (60.1% vs. 45.7%, p &lt; 0.0001). The analysis when severity of the abnormality was considered confirmed these results. Conclusions. There is an indication of increased sensitivity using the electronic stethoscope. Specificity was high using the electronic and acoustic stethoscope.<\/jats:p>","DOI":"10.3390\/medicina55040094","type":"journal-article","created":{"date-parts":[[2019,4,5]],"date-time":"2019-04-05T11:36:01Z","timestamp":1554464161000},"page":"94","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":28,"title":["A Comparison of Electronic and Traditional Stethoscopes in the Heart Auscultation of Obese Patients"],"prefix":"10.3390","volume":"55","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2251-3053","authenticated-orcid":false,"given":"Egl\u0117","family":"Kalinauskien\u0117","sequence":"first","affiliation":[{"name":"Department of Internal Medicine, Lithuanian University of Health Sciences, LT-47144 Kaunas, Lithuania"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Haroldas","family":"Razvadauskas","sequence":"additional","affiliation":[{"name":"Department of Internal Medicine, Lithuanian University of Health Sciences, LT-47144 Kaunas, Lithuania"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dan J.","family":"Morse","sequence":"additional","affiliation":[{"name":"3M Center, St. Paul, MN 55144, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gail E.","family":"Maxey","sequence":"additional","affiliation":[{"name":"3M Center, St. Paul, MN 55144, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Albinas","family":"Naud\u017ei\u016bnas","sequence":"additional","affiliation":[{"name":"Department of Internal Medicine, Lithuanian University of Health Sciences, LT-47144 Kaunas, Lithuania"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2019,4,5]]},"reference":[{"key":"ref_1","first-page":"283","article-title":"Cardiac auscultation: The past, present and future","volume":"17","author":"Asghar","year":"2010","journal-title":"Br. J. Cardiol."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"355","DOI":"10.1136\/pgmj.2003.014944","article-title":"A novel multimedia tool to improve bedside teaching of cardiac auscultation","volume":"80","author":"Woywodt","year":"2004","journal-title":"Postgrad. Med. J."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"653","DOI":"10.1016\/S0002-9149(97)00977-6","article-title":"Clinical comparison of acoustic and electronic stethoscopes and design of a new electronic stethoscope","volume":"181","author":"Grenier","year":"1998","journal-title":"Am. J. Cardiol."},{"key":"ref_4","doi-asserted-by":"crossref","unstructured":"H\u00f8yte, H., Jensen, T., and Gjesdal, K. (2005). Cardiac auscultation training of medical students: A comparison of electronic sensor-based and acoustic stethoscopes. BMC Med. Educ., 5.","DOI":"10.1186\/1472-6920-5-14"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"85.e1","DOI":"10.1016\/j.ahj.2006.04.013","article-title":"Effect of teaching and type of stethoscope on cardiac auscultatory performance","volume":"152","author":"Iversen","year":"2006","journal-title":"Am. Heart J."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"1255","DOI":"10.1161\/CIRCULATIONAHA.105.591149","article-title":"Cardiac auscultation: A glorious past\u2014And it does have a future!","volume":"113","author":"Tavel","year":"2006","journal-title":"Circulation"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"429","DOI":"10.1007\/BF02595918","article-title":"Causes of false-negative auscultation of regurgitant lesions: A Doppler echocardiographic study of 294 patients","volume":"3","author":"Kinney","year":"1988","journal-title":"J. Gen. Intern Med."},{"key":"ref_8","unstructured":"World Health Organization (WHO) (2000). Obesity, Preventing and Managing the Global Epidemic. Report of a WHO Consultation, World Health Organization."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"557","DOI":"10.1016\/S0140-6736(10)62037-5","article-title":"National, regional, and global trends in body-mass index since 1980: Systematic analysis of health examination surveys and epidemiological studies with 960 country-years and 9\u00b71 million participants","volume":"377","author":"Finucane","year":"2011","journal-title":"Lancet"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"491","DOI":"10.1001\/jama.2012.39","article-title":"Prevalence of obesity and trends in the distribution of body mass index among US adults, 1999\u20132010","volume":"307","author":"Flegal","year":"2012","journal-title":"JAMA"},{"key":"ref_11","unstructured":"Dittmar, T. (2011). Audio Engineering 101 in A Beginner\u2019s Guide to Music Production, Taylor & Francis."},{"key":"ref_12","unstructured":"Moller, A.R. (2006). Hearing: Anatomy, Physiology, and Disorders of the Auditory System, Academic Press. [2nd ed.]."},{"key":"ref_13","first-page":"e523","article-title":"Focused update incorporated into the ACC\/AHA 2006 guidelines for the management of patients with valvular heart disease: A report of the American College of Cardiology\/American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the 1998 Guidelines for the Management of Patients With Valvular Heart Disease): Endorsed by the Society of Cardiovascular Anesthesiologists, Society for Cardiovascular Angiography and Interventions, and Society of Thoracic Surgeons","volume":"118","author":"Bonow","year":"2008","journal-title":"Circulation"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"362","DOI":"10.1016\/j.medengphy.2010.11.004","article-title":"An adaptive singular spectrum analysis approach to murmur detection from heart sounds","volume":"33","author":"Saneia","year":"2011","journal-title":"Med. Eng. Phys."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1055\/s-0038-1623629","article-title":"Comparison of conventional and sensor-based electronic stethoscopes in detecting cardiac murmurs of dog","volume":"40","author":"Bonnevie","year":"2012","journal-title":"Tierarztl. Prax. Ausg. K. Kleintiere Heimtiere"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"893","DOI":"10.1177\/1098612X13485480","article-title":"Clinical evaluation of the 3M Littmann Electronic Stethoscope Model 3200 in 150 cats","volume":"15","author":"Blass","year":"2013","journal-title":"J. Feline. Med. Surg."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"369","DOI":"10.1111\/j.1475-097X.2010.00954.x","article-title":"Audiocardiography in the cardiovascular evaluation of the morbidly obese","volume":"30","author":"McCullough","year":"2010","journal-title":"Clin. Physiol. Funct. Imaging"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"29","DOI":"10.2147\/MDER.S135882","article-title":"Digital stethoscope: Technology update","volume":"11","author":"Swarup","year":"2018","journal-title":"Med Devices"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"786","DOI":"10.1016\/j.amjcard.2012.11.039","article-title":"Utility of an advanced digital electronic stethoscope in the diagnosis of coronary artery disease compared with coronary computed tomographic angiography","volume":"111","author":"Makaryus","year":"2013","journal-title":"Am. J. Cardiol."}],"container-title":["Medicina"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1648-9144\/55\/4\/94\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T12:43:17Z","timestamp":1760186597000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1648-9144\/55\/4\/94"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,4,5]]},"references-count":19,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2019,4]]}},"alternative-id":["medicina55040094"],"URL":"https:\/\/doi.org\/10.3390\/medicina55040094","relation":{},"ISSN":["1648-9144"],"issn-type":[{"value":"1648-9144","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,4,5]]}}}