{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,29]],"date-time":"2026-10-29T22:34:07Z","timestamp":1793313247985,"version":"4.5.0"},"reference-count":29,"publisher":"MDPI AG","issue":"8","license":[{"start":{"date-parts":[[2022,8,3]],"date-time":"2022-08-03T00:00:00Z","timestamp":1659484800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Medicina"],"abstract":"<jats:p>Background and Objectives: The TomoFix anatomical plate was developed to improve plate position, proximal screw direction, and post-correction tibial contouring. The purpose of this study was to compare postoperative configurations between the TomoFix anatomical plate and the TomoFix conventional plate. It was hypothesized that the new modified plate provides a better fixative coaptation than the conventional plate. Materials and Methods: A total of 116 cases (112 patients) were enrolled in this study from March 2015 to February 2021. Among them, 63 patients underwent surgery using the TomoFix conventional plate, and 53 underwent surgery using the TomoFix anatomical plate. The radiographic outcomes, including the hip\u2013knee\u2013ankle (HKA) angle, medial proximal tibial angle (MPTA), tibial slope, plate angle, proximal screw angles, and plate-to-cortex distance at #1 hole (just below the osteotomy site) were compared between the two groups. Results: Patients with the TomoFix anatomical plate showed similar results in terms of the pre- and postoperative HKA angle, MPTA, and tibial slope. The TomoFix anatomical group showed a significantly greater plate angle (39.2\u00b0 \u00b1 8.1\u00b0 vs. 31.7\u00b0 \u00b1 7.0\u00b0, p &lt; 0.001) and less screw angles, indicating that the TomoFix anatomical plates allowed a more posterior plate position than the conventional plate. The plate-to-cortex distance was significantly less in the TomoFix anatomical group than in the TomoFix conventional group (p &lt; 0.001). Conclusion: The TomoFix anatomical plate showed a more posteromedial plating position, better proximal screw direction to the lateral hinge, and improved post-correction tibial contour compared to the TomoFix conventional plate.<\/jats:p>","DOI":"10.3390\/medicina58081045","type":"journal-article","created":{"date-parts":[[2022,8,3]],"date-time":"2022-08-03T23:33:01Z","timestamp":1659569581000},"page":"1045","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Comparison of Anatomical Conformity between TomoFix Anatomical Plate and TomoFix Conventional Plate in Open-Wedge High Tibial Osteotomy"],"prefix":"10.3390","volume":"58","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-7728-0061","authenticated-orcid":false,"given":"Sung-Sahn","family":"Lee","sequence":"first","affiliation":[{"name":"Department of Orthopedic Surgery, Ilsan Paik Hospital, School of Medicine, Inje University, 170 Juwha Street, Goyangsi 10380, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jaesung","family":"Park","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, Samsung Medical Center, School of Medicine, Sungkyunkwan University, 81 Irwon Street, Seoul 06351, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dae-Hee","family":"Lee","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, Samsung Medical Center, School of Medicine, Sungkyunkwan University, 81 Irwon Street, Seoul 06351, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2022,8,3]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1007\/s00264-009-0889-8","article-title":"Results of high tibial osteotomy: Review of the literature","volume":"34","author":"Amendola","year":"2010","journal-title":"Int. Orthop."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1186\/s43019-020-00076-x","article-title":"Change of joint-line convergence angle should be considered for accurate alignment correction in high tibial osteotomy","volume":"33","author":"Na","year":"2021","journal-title":"Knee Surg. Relat. Res."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"317","DOI":"10.1016\/j.csm.2019.02.001","article-title":"Improved Methods to Measure Outcomes After High Tibial Osteotomy","volume":"38","author":"Lorbergs","year":"2019","journal-title":"Clin. Sports Med."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1186\/s43019-021-00127-x","article-title":"Analysis of changes in tibial torsion angle on open-wedge high tibial osteotomy depending on the osteotomy level","volume":"34","author":"Song","year":"2022","journal-title":"Knee Surg. Relat. Res."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1097\/00003086-198401000-00008","article-title":"Upper tibial osteotomy","volume":"182","author":"Coventry","year":"1984","journal-title":"Clin. Orthop. Relat. Res."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"B55","DOI":"10.1016\/j.injury.2003.09.025","article-title":"TomoFix: A new LCP-concept for open wedge osteotomy of the medial proximal tibia\u2014Early results in 92 cases","volume":"34","author":"Staubli","year":"2003","journal-title":"Injury"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1186\/s43019-020-00071-2","article-title":"Can medial stability be preserved after open wedge high tibial osteotomy?","volume":"32","author":"Kim","year":"2020","journal-title":"Knee Surg. Relat. Res."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"185","DOI":"10.4055\/cios.2015.7.2.185","article-title":"Biplanar Open Wedge High Tibial Osteotomy in the Medial Compartment Osteoarthritis of the Knee Joint: Comparison between the Aescula and TomoFix Plate","volume":"7","author":"Kyung","year":"2015","journal-title":"Clin. Orthop. Surg."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"167","DOI":"10.1007\/s00264-009-0902-2","article-title":"Evolution of open-wedge high-tibial osteotomy: Experience with a special angular stable device for internal fixation without interposition material","volume":"34","author":"Staubli","year":"2010","journal-title":"Int. Orthop."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1186\/s43019-021-00130-2","article-title":"How to achieve an optimal alignment in medial opening wedge high tibial osteotomy?","volume":"34","author":"Kang","year":"2022","journal-title":"Knee Surg. Relat. Res."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"1299","DOI":"10.1016\/j.knee.2017.07.015","article-title":"Primary stability of different plate positions and the role of bone substitute in open wedge high tibial osteotomy","volume":"24","author":"Takeuchi","year":"2017","journal-title":"Knee"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"2411","DOI":"10.1177\/0363546509341174","article-title":"Medial open wedge high tibial osteotomy: The effect of the cortical hinge on posterior tibial slope","volume":"37","author":"Wang","year":"2009","journal-title":"Am. J. Sports Med."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"111","DOI":"10.1016\/j.clinbiomech.2016.04.016","article-title":"Evaluation of the screw position and angle using a post-contoured plate in the open wedge high tibial osteotomy according to the correction degree and surgical technique","volume":"35","author":"Yoo","year":"2016","journal-title":"Clin. Biomech."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"627","DOI":"10.1016\/j.jos.2019.06.018","article-title":"Comparative analysis of fixation configurations and their effect on outcome after medial open-wedge high tibial osteotomy","volume":"25","author":"Lee","year":"2020","journal-title":"J. Orthop. Sci."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"846","DOI":"10.1007\/s00167-015-3954-4","article-title":"Applicability of a modified angular correction measurement method for open-wedge high tibial osteotomy","volume":"25","author":"Moore","year":"2017","journal-title":"Knee Surg. Sports Traumatol. Arthrosc."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"8","DOI":"10.1186\/s43019-021-00090-7","article-title":"Differences in preoperative planning for high-tibial osteotomy between the standing and supine positions","volume":"33","author":"Matsushita","year":"2021","journal-title":"Knee Surg. Relat. Res."},{"key":"ref_17","first-page":"204","article-title":"High Tibial Osteotomy: A Systematic Review and Current Concept","volume":"4","author":"Sabzevari","year":"2016","journal-title":"Arch. Bone Jt. Surg."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"358","DOI":"10.1016\/j.injury.2006.08.058","article-title":"Biomechanical testing of the locking compression plate: When does the distance between bone and implant significantly reduce construct stability?","volume":"38","author":"Ahmad","year":"2007","journal-title":"Injury"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"698","DOI":"10.1007\/s00167-018-4977-4","article-title":"Posterior cortical breakage leads to posterior tibial slope change in lateral hinge fracture following opening wedge high tibial osteotomy","volume":"27","author":"Lee","year":"2019","journal-title":"Knee Surg. Sports Traumatol. Arthrosc."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"90","DOI":"10.4055\/cios20268","article-title":"Medial Ball and Socket Total Knee Arthroplasty in Indian Population: 5-Year Clinical Results","volume":"14","author":"Batra","year":"2022","journal-title":"Clin. Orthop. Surg."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"2410","DOI":"10.1007\/s00167-018-5216-8","article-title":"The medial proximal tibial angle accurately corrects the limb alignment in open-wedge high tibial osteotomy","volume":"27","author":"Kubota","year":"2019","journal-title":"Knee Surg. Sports Traumatol. Arthrosc."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"2641","DOI":"10.1007\/s00167-013-2517-9","article-title":"Opening wedge high tibial osteotomy: Plate position and biomechanics of the medial tibial plateau","volume":"22","author":"Leyes","year":"2014","journal-title":"Knee Surg. Sports Traumatol. Arthrosc."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"1262","DOI":"10.1177\/0363546505286144","article-title":"Opening wedge high tibial osteotomy: An operative technique and rehabilitation program to decrease complications and promote early union and function","volume":"34","author":"Noyes","year":"2006","journal-title":"Am. J. Sports Med."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1016\/j.clinbiomech.2017.10.021","article-title":"The effect of wedge and tibial slope angles on knee contact pressure and kinematics following medial opening-wedge high tibial osteotomy","volume":"51","author":"Black","year":"2018","journal-title":"Clin. Biomech."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"218","DOI":"10.1055\/s-0030-1247752","article-title":"Complications after tomofix medial opening wedge high tibial osteotomy","volume":"22","author":"Valkering","year":"2009","journal-title":"J. Knee Surg."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"48","DOI":"10.1016\/j.medengphy.2017.01.007","article-title":"The effects of tibia profile, distraction angle, and knee load on wedge instability and hinge fracture: A finite element study","volume":"42","author":"Weng","year":"2017","journal-title":"Med. Eng. Phys."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"1552","DOI":"10.1177\/0363546505275488","article-title":"The effect of lateral cortex disruption and repair on the stability of the medial opening wedge high tibial osteotomy","volume":"33","author":"Miller","year":"2005","journal-title":"Am. J. Sports Med."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"217","DOI":"10.1007\/s00264-009-0723-3","article-title":"Stability of medial opening wedge high tibial osteotomy: A failure analysis","volume":"34","author":"Nelissen","year":"2010","journal-title":"Int. Orthop."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"3361","DOI":"10.1007\/s00167-020-06199-8","article-title":"Low rates of serious complications but high rates of hardware removal after high tibial osteotomy with Tomofix locking plate","volume":"29","author":"Sidhu","year":"2020","journal-title":"Knee Surg. Sports Traumatol. Arthrosc."}],"container-title":["Medicina"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1648-9144\/58\/8\/1045\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T00:03:45Z","timestamp":1760141025000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1648-9144\/58\/8\/1045"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,8,3]]},"references-count":29,"journal-issue":{"issue":"8","published-online":{"date-parts":[[2022,8]]}},"alternative-id":["medicina58081045"],"URL":"https:\/\/doi.org\/10.3390\/medicina58081045","relation":{},"ISSN":["1648-9144"],"issn-type":[{"value":"1648-9144","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,8,3]]}}}