{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T02:17:20Z","timestamp":1760149040703,"version":"build-2065373602"},"reference-count":20,"publisher":"MDPI AG","issue":"7","license":[{"start":{"date-parts":[[2023,6,29]],"date-time":"2023-06-29T00:00:00Z","timestamp":1687996800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Medicina"],"abstract":"<jats:p>Background and Objectives: Minimally invasive cardiac surgery (MICS) has been developing since 1996. Peripheral cannulation is required to perform MICS, and good venous drainage and a bloodless field are crucial for the success of this procedure. We assessed the benefits of using a virtually wall-less cannula in comparison with the standard thin-wall cannula in clinical practice. Materials and Methods: Between January 2021 and December 2022, we evaluated 65 elective patients, who underwent isolated minimally invasive mitral valve surgery. Both the virtually wall-less and the thin-wall cannulas were placed through a surgical cut-down. Patients\u2019 characteristics at baseline were similar in the two groups, except for the body surface area (BSA), which was greater in the virtually wall-less group compared to the thin-wall one. In the standard group, the size of the cannula was chosen depending on the patient\u2019s BSA, and the choice of the Smartcannula was based on their height. Results: There were no significant differences between the two groups in terms of negative pressure applied, target flow achieved, hemolysis, the need for blood transfusion, and the post-operative increases in liver and renal enzymes. However, in all the patients, the estimated target flow was achieved, thereby showing the better hemodynamic performance of the virtually wall-less cannula, since, in this group, the patients\u2019 BSA was significantly greater compared to the thin-wall group. Ultimately, the mean cross-clamp time, as an indirect index of the effectiveness of the venous drainage, is shorter in the virtually wall-less group compared with the thin-wall group. Conclusions: The virtually wall-less cannula should be preferred in minimally invasive mitral valve surgery due to its superior performance in terms of venous drainage compared with the standard thin-wall cannula.<\/jats:p>","DOI":"10.3390\/medicina59071221","type":"journal-article","created":{"date-parts":[[2023,6,30]],"date-time":"2023-06-30T00:43:30Z","timestamp":1688085810000},"page":"1221","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Virtually Wall-Less versus Standard Thin-Wall Venous Cannula in the Minimally Invasive Mitral Valve Surgery: Single-Center Experience"],"prefix":"10.3390","volume":"59","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-1286-0505","authenticated-orcid":false,"given":"Fabrizio","family":"Ceresa","sequence":"first","affiliation":[{"name":"Cardio-Vascular and Thoracic Department, Papardo Hospital, 98121 Messina, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Liborio Francesco","family":"Mammana","sequence":"additional","affiliation":[{"name":"Cardio-Vascular and Thoracic Department, Papardo Hospital, 98121 Messina, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Aurora","family":"Leonardi","sequence":"additional","affiliation":[{"name":"Cardio-Vascular and Thoracic Department, Papardo Hospital, 98121 Messina, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Augusto","family":"Palermo","sequence":"additional","affiliation":[{"name":"Cardio-Vascular and Thoracic Department, Papardo Hospital, 98121 Messina, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Francesco","family":"Patan\u00e8","sequence":"additional","affiliation":[{"name":"Cardio-Vascular and Thoracic Department, Papardo Hospital, 98121 Messina, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2023,6,29]]},"reference":[{"key":"ref_1","first-page":"219","article-title":"Open heart operation under videosurgery and minithoracotomy. First case (mitral valvuloplasty) operated with success","volume":"319","author":"Carpentier","year":"1996","journal-title":"Comptes Rendus Acad. Sci."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"361","DOI":"10.1177\/0267659106071324","article-title":"Vacuum-assisted venous drainage in extrathoracic cardioplumonary bypass management during minimally invasive cardiac surgery","volume":"21","author":"Lapenna","year":"2006","journal-title":"Perfusion"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"104","DOI":"10.1097\/imi.0000000000000478","article-title":"Clinical experience in minimally invasive cardiac surgery with virtually wall-less venous cannulas","volume":"13","author":"Ferrari","year":"2018","journal-title":"Innovations"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"635","DOI":"10.1016\/j.ejcts.2008.05.037","article-title":"Routine use of self-expanding venous cannulas for cardiopulmonary bypass: Benefits pitfalls in 100 consecutive cases","volume":"34","author":"Ferrari","year":"2008","journal-title":"Eur. J. Cardiothorac. Surg."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"278","DOI":"10.1097\/imi.0000000000000283","article-title":"New, virtually wall-less cannulas designed for augmented venous drainage in minimally invasive cardiac surgery","volume":"11","author":"Berdaj","year":"2016","journal-title":"Innovations"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"e241","DOI":"10.1532\/HSF98.20051127","article-title":"The Smartcannulla: A new tool for remote access perfusion in limited access cardiac surgey","volume":"8","author":"Jegger","year":"2005","journal-title":"Heart Surg. Forum"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"257","DOI":"10.1177\/0267659107083657","article-title":"Using computational flow dynamics to evaluate a novel venous cannula (Smart Cannula) for use in cardiopulmonary bypass operating procedures","volume":"22","author":"Jegger","year":"2007","journal-title":"Perfusion"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"306","DOI":"10.1093\/ejcts\/ezt620","article-title":"Caval collapse during cardiopulmonary bypass: A reproducible bench model","volume":"46","author":"Li","year":"2014","journal-title":"Eur. J. Cardiothorac. Surg."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1177\/0267659114560042","article-title":"How to prevent veous cannula orifice obstruction during extracorporeal circulation","volume":"30","author":"Favre","year":"2015","journal-title":"Perfusion"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"1096","DOI":"10.1510\/icvts.2008.182246","article-title":"Temporary caval stenting improves venous drainage during cardiopulmonary bypass","volume":"7","author":"Siniscalchi","year":"2008","journal-title":"Interact. Cardiovasc. Thorac. Surg."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"194","DOI":"10.1093\/icvts\/ivu318","article-title":"Venous cannula performance assessment in a realistic caval tree model","volume":"20","author":"Li","year":"2015","journal-title":"Interact. Cardiovasc. Thorac. Surg."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"393","DOI":"10.1177\/0267659119885514","article-title":"Effect of blood viscosity on the performace of virtually wall-less venous cannulas","volume":"35","author":"Berdajs","year":"2020","journal-title":"Perfusion"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"211","DOI":"10.1177\/0267659110375863","article-title":"Superior venous drainage in the Lifebox: A portable extracorporeal oxygenator with a self-expanding cannula","volume":"25","author":"Berdajs","year":"2010","journal-title":"Perfusion"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"s1330","DOI":"10.1016\/S0003-4975(02)03963-2","article-title":"A new expandable venous cannula for minimal access heart surgery","volume":"74","author":"Mueller","year":"2002","journal-title":"Ann. Thorac. Surg."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"160","DOI":"10.1051\/ject\/1998304160","article-title":"Assisted venous drainage venous air gaseous microemboli transmission into the arterial line: A vitro study","volume":"30","author":"Rider","year":"1998","journal-title":"J. Extra Corpor. Technol."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"856","DOI":"10.1067\/mtc.2000.110183","article-title":"Assisted venous drainage presents the risk of undetected air microembolism","volume":"120","author":"Lapietra","year":"2000","journal-title":"J. Thorac. Cardiovas. Surg."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"2132","DOI":"10.1016\/S0003-4975(02)04081-X","article-title":"Does vacuum assisted venous drainage increase gaseous microemboli during cardiopulmonary bypass?","volume":"74","author":"Jones","year":"2002","journal-title":"Ann. Thorac. Surg."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"418","DOI":"10.1016\/j.ejcts.2007.11.022","article-title":"Kinetci assisted venous drainage for orthotopic heart transplantation in patient under mechanical circulatory support: A double-edged sword","volume":"33","author":"Kirsch","year":"2008","journal-title":"Eur. J. Cardiothorac. Surg."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"591","DOI":"10.1510\/icvts.2011.276873","article-title":"The new advanced membrane gas exchanger","volume":"13","author":"Berdajs","year":"2011","journal-title":"Interact. Cardiovasc. Thorac. Surg."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"840","DOI":"10.1016\/S1010-7940(02)00086-6","article-title":"A new concept of integrated cardiopulmonary bypass circuit","volume":"21","author":"Mueller","year":"2002","journal-title":"Eur. J. Cardiothorac. Surg."}],"container-title":["Medicina"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1648-9144\/59\/7\/1221\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T20:03:33Z","timestamp":1760126613000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1648-9144\/59\/7\/1221"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,6,29]]},"references-count":20,"journal-issue":{"issue":"7","published-online":{"date-parts":[[2023,7]]}},"alternative-id":["medicina59071221"],"URL":"https:\/\/doi.org\/10.3390\/medicina59071221","relation":{},"ISSN":["1648-9144"],"issn-type":[{"type":"electronic","value":"1648-9144"}],"subject":[],"published":{"date-parts":[[2023,6,29]]}}}