{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,28]],"date-time":"2026-06-28T22:50:51Z","timestamp":1782687051725,"version":"3.54.5"},"reference-count":74,"publisher":"MDPI AG","issue":"4","license":[{"start":{"date-parts":[[2024,3,22]],"date-time":"2024-03-22T00:00:00Z","timestamp":1711065600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Medicina"],"abstract":"<jats:p>The application of cardiac magnetic resonance (CMR) imaging in clinical practice has grown due to technological advancements and expanded clinical indications, highlighting its superior capabilities when compared to echocardiography for the assessment of myocardial tissue. Similarly, the utilization of implantable cardiac electronic devices (CIEDs) has significantly increased in cardiac arrhythmia management, and the requirements of CMR examinations in patients with CIEDs has become more common. However, this type of exam often presents challenges due to safety concerns and image artifacts. Until a few years ago, the presence of CIED was considered an absolute contraindication to CMR. To address these challenges, various technical improvements in CIED technology, like the reduction of the ferromagnetic components, and in CMR examinations, such as the introduction of new sequences, have been developed. Moreover, a rigorous protocol involving multidisciplinary collaboration is recommended for safe CMR examinations in patients with CIEDs, emphasizing risk assessment, careful monitoring during CMR, and post-scan device evaluation. Alternative methods to CMR, such as computed tomography coronary angiography with tissue characterization techniques like dual-energy and photon-counting, offer alternative potential solutions, although their diagnostic accuracy and availability do limit their use. Despite technological advancements, close collaboration and specialized staff training remain crucial for obtaining safe diagnostic CMR images in patients with CIEDs, thus justifying the presence of specialized centers that are equipped to handle these type of exams.<\/jats:p>","DOI":"10.3390\/medicina60040522","type":"journal-article","created":{"date-parts":[[2024,3,22]],"date-time":"2024-03-22T10:58:02Z","timestamp":1711105082000},"page":"522","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Cardiac Magnetic Resonance and Cardiac Implantable Electronic Devices: Are They Truly Still \u201cEnemies\u201d?"],"prefix":"10.3390","volume":"60","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2993-5718","authenticated-orcid":false,"given":"Marco","family":"Fogante","sequence":"first","affiliation":[{"name":"Maternal-Child, Senological, Cardiological Radiology and Outpatient Ultrasound, Department of Radiological Sciences, University Hospital of Marche, 60126 Ancona, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Giovanni","family":"Volpato","sequence":"additional","affiliation":[{"name":"Cardiology and Arrhythmology Clinic, University Hospital \u201cAzienda Ospedaliero-Universitaria delle Marche\u201d, 60126 Ancona, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Paolo","family":"Esposto Pirani","sequence":"additional","affiliation":[{"name":"Maternal-Child, Senological, Cardiological Radiology and Outpatient Ultrasound, Department of Radiological Sciences, University Hospital of Marche, 60126 Ancona, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fatjon","family":"Cela","sequence":"additional","affiliation":[{"name":"Maternal-Child, Senological, Cardiological Radiology and Outpatient Ultrasound, Department of Radiological Sciences, University Hospital of Marche, 60126 Ancona, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1924-6548","authenticated-orcid":false,"given":"Paolo","family":"Compagnucci","sequence":"additional","affiliation":[{"name":"Cardiology and Arrhythmology Clinic, University Hospital \u201cAzienda Ospedaliero-Universitaria delle Marche\u201d, 60126 Ancona, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0454-0739","authenticated-orcid":false,"given":"Yari","family":"Valeri","sequence":"additional","affiliation":[{"name":"Cardiology and Arrhythmology Clinic, University Hospital \u201cAzienda Ospedaliero-Universitaria delle Marche\u201d, 60126 Ancona, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6080-8031","authenticated-orcid":false,"given":"Adelina","family":"Selimi","sequence":"additional","affiliation":[{"name":"Cardiology and Arrhythmology Clinic, University Hospital \u201cAzienda Ospedaliero-Universitaria delle Marche\u201d, 60126 Ancona, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0003-7969-7428","authenticated-orcid":false,"given":"Michele","family":"Alfieri","sequence":"additional","affiliation":[{"name":"Cardiology and Arrhythmology Clinic, University Hospital \u201cAzienda Ospedaliero-Universitaria delle Marche\u201d, 60126 Ancona, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Leonardo","family":"Brugiatelli","sequence":"additional","affiliation":[{"name":"Cardiology and Arrhythmology Clinic, University Hospital \u201cAzienda Ospedaliero-Universitaria delle Marche\u201d, 60126 Ancona, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sara","family":"Belleggia","sequence":"additional","affiliation":[{"name":"Cardiology and Arrhythmology Clinic, University Hospital \u201cAzienda Ospedaliero-Universitaria delle Marche\u201d, 60126 Ancona, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Francesca","family":"Coraducci","sequence":"additional","affiliation":[{"name":"Cardiology and Arrhythmology Clinic, University Hospital \u201cAzienda Ospedaliero-Universitaria delle Marche\u201d, 60126 Ancona, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Giulio","family":"Argalia","sequence":"additional","affiliation":[{"name":"Maternal-Child, Senological, Cardiological Radiology and Outpatient Ultrasound, Department of Radiological Sciences, University Hospital of Marche, 60126 Ancona, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5322-1742","authenticated-orcid":false,"given":"Michela","family":"Casella","sequence":"additional","affiliation":[{"name":"Cardiology and Arrhythmology Clinic, University Hospital \u201cAzienda Ospedaliero-Universitaria delle Marche\u201d, 60126 Ancona, Italy"},{"name":"Department of Clinical, Special and Dental Sciences, Marche Polytechnic University, 60121 Ancona, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Antonio","family":"Dello Russo","sequence":"additional","affiliation":[{"name":"Cardiology and Arrhythmology Clinic, University Hospital \u201cAzienda Ospedaliero-Universitaria delle Marche\u201d, 60126 Ancona, Italy"},{"name":"Department of Biomedical Sciences and Public Health, Marche Polytechnic University, 60121 Ancona, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nicol\u00f2","family":"Schicchi","sequence":"additional","affiliation":[{"name":"Cardiovascular Radiological Diagnostics, Department of Radiological Sciences, University Hospital of Marche, 60126 Ancona, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2024,3,22]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"764","DOI":"10.1097\/RLI.0000000000000809","article-title":"Impact of Field Strength in Clinical Cardiac Magnetic Resonance Imaging","volume":"56","author":"Holtackers","year":"2021","journal-title":"Investig. Radiol."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1007\/s11886-021-01464-9","article-title":"Cardiovascular Magnetic Resonance Imaging and Heart Failure","volume":"23","author":"Liu","year":"2021","journal-title":"Curr. Cardiol. Rep."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"e223008","DOI":"10.1148\/radiol.223008","article-title":"Cardiac MRI: State of the Art","volume":"307","author":"Rajiah","year":"2023","journal-title":"Radiology"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"e230048","DOI":"10.1148\/ryct.230048","article-title":"Echocardiography versus Cardiac MRI for Measurement of Left Ventricular Ejection Fraction in Individuals with Cancer and Suspected Cardiotoxicity","volume":"6","author":"Nazir","year":"2024","journal-title":"Radiol. Cardiothorac. Imaging"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1016\/j.hjc.2023.01.003","article-title":"Cardiovascular magnetic resonance for the evaluation of patients with cardiovascular disease: An overview of current indications, limitations, and procedures","volume":"70","author":"Mavrogeni","year":"2023","journal-title":"Hell. J. Cardiol."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"1246","DOI":"10.1016\/j.amjcard.2019.07.036","article-title":"Meta-Analysis of Transthoracic Echocardiography Versus Cardiac Magnetic Resonance for the Assessment of Aortic Regurgitation After Transcatheter Aortic Valve Implantation","volume":"124","author":"Papanastasiou","year":"2019","journal-title":"Am. J. Cardiol."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"235","DOI":"10.1097\/RTI.0000000000000701","article-title":"The Role and Advantages of Cardiac Magnetic Resonance in the Diagnosis of Myocardial Ischemia","volume":"38","author":"Silva","year":"2023","journal-title":"J. Thorac. Imaging"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"e014068","DOI":"10.1161\/CIRCIMAGING.122.014068","article-title":"Imaging Methods: Magnetic Resonance Imaging","volume":"16","author":"Thomas","year":"2023","journal-title":"Circ. Cardiovasc. Imaging"},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Bazmpani, M.A., Nikolaidou, C., Papanastasiou, C.A., Ziakas, A., and Karamitsos, T.D. (2022). Cardiovascular Magnetic Resonance Parametric Mapping Techniques for the Assessment of Chronic Coronary Syndromes. J. Cardiovasc. Dev. Dis., 9.","DOI":"10.3390\/jcdd9120443"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"379","DOI":"10.1016\/j.ccep.2023.04.009","article-title":"Impact of Cardiac Magnetic Resonance to Arrhythmic Risk Stratification in Nonischemic Cardiomyopathy","volume":"15","author":"Claver","year":"2023","journal-title":"Card. Electrophysiol. Clin."},{"key":"ref_11","first-page":"e48471","article-title":"Safety and Efficacy of an Implantable Cardioverter Defibrillator (ICD) in the Detection and Prevention of Cardiac Arrhythmia\u2014A Systematic Review","volume":"15","author":"Tran","year":"2023","journal-title":"Cureus"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"465","DOI":"10.1016\/j.mric.2019.04.006","article-title":"Applications of Cardiac MR Imaging in Electrophysiology: Current Status and Future Needs","volume":"27","author":"Okada","year":"2019","journal-title":"Magn. Reson. Imaging Clin. N. Am."},{"key":"ref_13","unstructured":"Yeung, S.S.T., Clark, M., and Loshak, H. (2019). Magnetic Resonance Imaging for Patients with Implantable Cardiac Devices: A Review of Safety and Guidelines."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"360","DOI":"10.1111\/pace.14141","article-title":"MRI in patients with cardiac implantable electronic devices: A comprehensive review","volume":"44","author":"Deshpande","year":"2021","journal-title":"Pacing Clin. Electrophysiol."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"322","DOI":"10.1016\/j.ijcard.2021.02.003","article-title":"Cardiovascular magnetic resonance: What clinicians should know about safety and contraindications","volume":"331","author":"Barison","year":"2021","journal-title":"Int. J. Cardiol."},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"Talle, M.A., Doubell, A.F., Robbertse, P.-P.S., Lahri, S., and Herbst, P.G. (2023). Cardiac Morphology, Function, and Left Ventricular Geometric Pattern in Patients with Hypertensive Crisis: A Cardiovascular Magnetic Resonance-Based Study. J. Cardiovasc. Dev. Dis., 10.","DOI":"10.3390\/jcdd10090367"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"101002","DOI":"10.1016\/j.jocmr.2024.101002","article-title":"Prognostic Value of Mid-term Cardiac Magnetic Resonance Follow-up in Patients with Non-ischemic Dilated Cardiomyopathy: A prospective cohort study","volume":"26","author":"Xu","year":"2024","journal-title":"J. Cardiovasc. Magn. Reson."},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Compagnucci, P., Volpato, G., Falanga, U., Cipolletta, L., Conti, M.A., Grifoni, G., Ciliberti, G., Stronati, G., Fogante, M., and Bergonti, M. (2021). Myocardial Inflammation, Sports Practice, and Sudden Cardiac Death: 2021 Update. Medicina, 57.","DOI":"10.3390\/medicina57030277"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1080\/00015385.2023.2279417","article-title":"Review and critical appraisal of the indications for cardiac magnetic resonance imaging in the ESC guidelines","volume":"79","author":"Gerber","year":"2023","journal-title":"Acta Cardiol."},{"key":"ref_20","first-page":"2223","article-title":"Sudden Cardiac Death in Ischemic Heart Disease: From Imaging Arrhythmogenic Substrate to Guiding Therapies","volume":"13","author":"Benz","year":"2020","journal-title":"JACC Cardiovasc. Imaging"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"e021370","DOI":"10.1161\/JAHA.121.021370","article-title":"Endomyocardial Biopsy: The Forgotten Piece in the Arrhythmogenic Cardiomyopathy Puzzle","volume":"10","author":"Casella","year":"2021","journal-title":"J. Am. Heart Assoc."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"130","DOI":"10.1016\/j.ijcard.2020.11.044","article-title":"Risk and predictors of sudden death in cardiac sarcoidosis: A systematic review and meta-analysis","volume":"328","author":"Franke","year":"2021","journal-title":"Int. J. Cardiol."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1186\/s12968-023-00959-4","article-title":"Society for Cardiovascular Magnetic Resonance perspective on the ACC\/AHA\/ASE\/ASNC\/ASPC\/HFSA\/HRS\/SCAI\/SCCT\/SCMR\/STS 2023 multi-modality appropriate use criteria for the detection and risk assessment of chronic coronary disease","volume":"25","author":"Bandettini","year":"2023","journal-title":"J Cardiovasc. Magn. Reson."},{"key":"ref_24","doi-asserted-by":"crossref","unstructured":"Fogante, M., Agliata, G., Basile, M.C., Compagnucci, P., Volpato, G., Falanga, U., Stronati, G., Guerra, F., Vignale, D., and Esposito, A. (2021). Cardiac Imaging in Athlete\u2019s Heart: The Role of the Radiologist. Medicina, 57.","DOI":"10.3390\/medicina57050455"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"673","DOI":"10.2967\/jnumed.111.099838","article-title":"Cardiovascular molecular imaging: The road ahead","volume":"53","author":"Majmudar","year":"2012","journal-title":"J. Nucl. Med."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"1387","DOI":"10.1016\/j.jcmg.2017.08.017","article-title":"Cardiac Tissue Characterization and Imaging in Autoimmune Rheumatic Diseases","volume":"10","author":"Mavrogeni","year":"2017","journal-title":"JACC Cardiovasc. Imaging"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1080\/00015385.2023.2276537","article-title":"Systematic review of leadless pacemaker","volume":"14","author":"Xu","year":"2023","journal-title":"Acta Cardiol."},{"key":"ref_28","first-page":"311","article-title":"A Systematic Review and Meta-analysis of the Prevalence and Risk Factors in Cardiac Implantable Electronic Device Malfunction","volume":"35","author":"Saeed","year":"2023","journal-title":"J. Saudi Heart Assoc."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"197","DOI":"10.1016\/j.ijcard.2022.09.026","article-title":"Peri-procedural and mid-term follow-up age-related differences in leadless pacemaker implantation: Insights from a multicenter European registry","volume":"371","author":"Gulletta","year":"2023","journal-title":"Int. J. Cardiol."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"e002096","DOI":"10.1136\/openhrt-2022-002096","article-title":"Remote monitoring in patients with heart failure with cardiac implantable electronic devices: A systematic review and meta-analysis","volume":"9","author":"McGee","year":"2022","journal-title":"Open Heart"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"729786","DOI":"10.3389\/fcvm.2021.729786","article-title":"Imaging of Cardiac Device-Related Infection","volume":"8","author":"Aguilera","year":"2021","journal-title":"Front. Cardiovasc. Med."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"2050","DOI":"10.1016\/j.hrthm.2021.07.008","article-title":"Long-term complications in patients implanted with subcutaneous implantable cardioverter-defibrillators: Real-world data from the extended ELISIR experience","volume":"18","author":"Gasperetti","year":"2021","journal-title":"Heart Rhythm."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"618","DOI":"10.1002\/clc.22300","article-title":"Unexplained syncope: Implications of age and gender on patient characteristics and evaluation, the diagnostic yield of an implantable loop recorder, and the subsequent treatment","volume":"37","author":"Edvardsson","year":"2014","journal-title":"Clin. Cardiol."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"1236","DOI":"10.1111\/pace.12688","article-title":"Role of Outpatient Cardiac Rhythm Monitoring in Cryptogenic Stroke: A Systematic Review and Meta-Analysis","volume":"38","author":"Gasperetti","year":"2015","journal-title":"Pacing Clin. Electrophysiol."},{"key":"ref_35","first-page":"628","article-title":"Recurrence of atrial fibrillation postablation: Which is the most effective approach for detection?","volume":"70","author":"Gasperetti","year":"2022","journal-title":"Minerva Cardiol. Angiol."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1016\/j.ekir.2020.10.020","article-title":"A Systematic Review of the Incidence of Arrhythmias in Hemodialysis Patients Undergoing Long-Term Monitoring with Implantable Loop Recorders","volume":"6","author":"Roberts","year":"2021","journal-title":"Kidney Int. Rep."},{"key":"ref_37","doi-asserted-by":"crossref","unstructured":"Evidence Review Committee Members, Varosy, P.D., Chen, L.Y., Miller, A.L., Noseworthy, P.A., Slotwiner, D.J., and Thiruganasambandamoorthy, V. (2017). Pacing as a treatment for reflex-mediated (vasovagal, situational, or carotid sinus hypersensitivity) syncope: A systematic review for the 2017 ACC\/AHA\/HRS guideline for the evaluation and management of patients with syncope: A report of the American College of Cardiology\/American Heart Association Task Force on Clinical Practice Guidelines and the Heart Rhythm Society. Heart Rhythm., 14, e255\u2013e269.","DOI":"10.1016\/j.hrthm.2017.03.006"},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"440","DOI":"10.1016\/j.tcm.2021.08.001","article-title":"Magnetic resonance imaging safety in patients with cardiac implantable electronic devices","volume":"32","author":"Yang","year":"2022","journal-title":"Trends Cardiovasc. Med."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"549","DOI":"10.1016\/j.mric.2020.08.001","article-title":"MR Safety: Active Implanted Electronic Devices","volume":"28","author":"Watson","year":"2020","journal-title":"Magn. Reson. Imaging Clin. N. Am."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"851","DOI":"10.1016\/j.jcmg.2019.01.043","article-title":"Use of Contemporary Imaging Techniques for Electrophysiological and Device Implantation Procedures","volume":"13","author":"Auricchio","year":"2020","journal-title":"JACC Cardiovasc. Imaging"},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"3427","DOI":"10.1093\/eurheartj\/ehab699","article-title":"2021 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy","volume":"42","author":"Michowitz","year":"2021","journal-title":"Eur. Heart J."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1046\/j.1460-9592.2001.00199.x","article-title":"Force and Torque Effects of a 1.5-Tesla MRI Scanner on Cardiac Pacemakers and ICDs","volume":"24","author":"Luechinger","year":"2001","journal-title":"Pacing Clin. Electrophysiol."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"1419","DOI":"10.1046\/j.1460-9592.2002.01419.x","article-title":"Pacemaker Reed Switch Behavior in 0.5, 1.5, and 3.0 Tesla Magnetic Resonance Imaging Units: Are Reed Switches Always Closed in Strong Magnetic Fields?","volume":"25","author":"Luechinger","year":"2002","journal-title":"Pacing Clin. Electrophysiol."},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"W1","DOI":"10.1097\/RTI.0000000000000462","article-title":"Cardiac Magnetic Resonance in Patients with Cardiac Implantable Electronic Devices: Challenges and Solutions","volume":"35","author":"Rajiah","year":"2020","journal-title":"J. Thorac. Imaging"},{"key":"ref_45","doi-asserted-by":"crossref","unstructured":"Barison, A., Ricci, F., Pavon, A.G., Muscogiuri, G., Bisaccia, G., Camastra, G., De Lazzari, M., Lanzillo, C., Raguso, M., and Monti, L. (2023). Cardiovascular Magnetic Resonance in Patients with Cardiac Electronic Devices: Evidence from a Multicenter Study. J. Clin. Med., 12.","DOI":"10.3390\/jcm12206673"},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"125","DOI":"10.1007\/s10840-019-00526-x","article-title":"Viewpoint: Cardiac implantable electronic devices and magnetic resonance compatibility: Was it really necessary?","volume":"55","author":"Sutton","year":"2019","journal-title":"J. Interv. Card. Electrophysiol."},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"1229","DOI":"10.1007\/s00330-022-09059-w","article-title":"Reducing cardiac implantable electronic device\u2013induced artefacts in cardiac magnetic resonance imaging","volume":"33","author":"Vuorinen","year":"2022","journal-title":"Eur. Radiol."},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"e97","DOI":"10.1016\/j.hrthm.2017.04.025","article-title":"2017 HRS expert consensus statement on magnetic resonance imaging and radiation exposure in patients with cardiovascular implantable electronic devices","volume":"14","author":"Indik","year":"2017","journal-title":"Heart Rhythm."},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"138","DOI":"10.1111\/jce.14798","article-title":"Evaluation of image quality of wideband single-shot late gadolinium-enhancement MRI in patients with a cardiac implantable electronic device","volume":"32","author":"Schwartz","year":"2021","journal-title":"J. Cardiovasc. Electrophysiol."},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"1682","DOI":"10.1016\/j.cjca.2018.09.009","article-title":"Performing Cardiac Magnetic Resonance Imaging in Patients With Cardiac Implantable Electronic Devices: A Contemporary Review","volume":"34","author":"Blissett","year":"2018","journal-title":"Can. J. Cardiol."},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"1389","DOI":"10.1111\/pace.13232","article-title":"Clinical safety and performance of a MRI conditional pacing system in patients undergoing cardiac MRI","volume":"40","author":"Ching","year":"2017","journal-title":"Pacing Clin. Electrophysiol."},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"e004025","DOI":"10.1161\/CIRCIMAGING.115.004025","article-title":"Image Quality of Cardiac Magnetic Resonance Imaging in Patients with an Implantable Cardioverter Defibrillator System Designed for the Magnetic Resonance Imaging Environment","volume":"9","author":"Schwitter","year":"2016","journal-title":"Circ. Cardiovasc. Imaging"},{"key":"ref_53","doi-asserted-by":"crossref","first-page":"374","DOI":"10.2214\/AJR.19.21883","article-title":"Cardiac MRI for Patients with Cardiac Implantable Electronic Devices","volume":"215","author":"Stojanovska","year":"2020","journal-title":"Am. J. Roentgenol."},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1016\/j.repc.2020.05.009","article-title":"Consensus document on magnetic resonance imaging in patients with cardiac implanted electronic devices","volume":"40","author":"Almeida","year":"2021","journal-title":"Rev. Port. Cardiol."},{"key":"ref_55","doi-asserted-by":"crossref","first-page":"555","DOI":"10.2214\/AJR.19.21187","article-title":"Metal Artifact Reduction in Cardiovascular MRI for Accurate Myocardial Scar Assessment in Patients with Cardiac Implantable Electronic Devices","volume":"213","author":"Runge","year":"2019","journal-title":"Am. J. Roentgenol."},{"key":"ref_56","doi-asserted-by":"crossref","first-page":"100","DOI":"10.4329\/wjr.v10.i9.100","article-title":"Optimized cardiac magnetic resonance imaging inversion recovery sequence for metal artifact reduction and accurate myocardial scar assessment in patients with cardiac implantable electronic devices","volume":"10","author":"Ibrahim","year":"2018","journal-title":"World J. Radiol."},{"key":"ref_57","doi-asserted-by":"crossref","unstructured":"Bu\u010di\u0107, D., and Hrabak-Paar, M. (2023). Multimodality imaging in patients with implantable loop recorders: Tips and tricks. Hell. J. Cardiol., in press.","DOI":"10.1016\/j.hjc.2023.12.001"},{"key":"ref_58","doi-asserted-by":"crossref","first-page":"288","DOI":"10.1093\/europace\/euz343","article-title":"Magnetic resonance imaging in non-conditional pacemakers and implantable cardioverter-defibrillators: A systematic review and meta-analysis","volume":"22","author":"Munawar","year":"2020","journal-title":"Europace"},{"key":"ref_59","doi-asserted-by":"crossref","first-page":"473","DOI":"10.1016\/j.acvd.2020.03.015","article-title":"Joint Position Paper of the Working Group of Pacing and Electrophysiology of the French Society of Cardiology and the French Society of Diagnostic and Interventional Cardiac and Vascular Imaging on magnetic resonance imaging in patients with cardiac electronic implantable devices","volume":"113","author":"Gandjbakhch","year":"2020","journal-title":"Arch. Cardiovasc. Dis."},{"key":"ref_60","doi-asserted-by":"crossref","first-page":"1378","DOI":"10.1007\/s00330-019-06449-5","article-title":"Making MRI available for patients with cardiac implantable electronic devices: Growing need and barriers to change","volume":"30","author":"Bhuva","year":"2020","journal-title":"Eur. Radiol."},{"key":"ref_61","doi-asserted-by":"crossref","first-page":"e3","DOI":"10.1136\/heartjnl-2022-320810","article-title":"Joint British Society consensus recommendations for magnetic resonance imaging for patients with cardiac implantable electronic devices","volume":"110","author":"Bhuva","year":"2022","journal-title":"Heart"},{"key":"ref_62","first-page":"1512","article-title":"EHRA consensus on prevention and management of interference due to medical procedures in patients with cardiac implantable electronic devices","volume":"24","author":"Burri","year":"2022","journal-title":"EP Eur."},{"key":"ref_63","doi-asserted-by":"crossref","first-page":"2465","DOI":"10.1053\/j.jvca.2019.09.012","article-title":"Perioperative Interrogation of Medtronic Cardiovascular Implantable Electronic Devices: A Guide for Anesthesiologists","volume":"34","author":"Cronin","year":"2020","journal-title":"J. Cardiothorac. Vasc. Anesthesia"},{"key":"ref_64","doi-asserted-by":"crossref","first-page":"24","DOI":"10.1097\/01.NURSE.0000651612.85237.fc","article-title":"Current guidelines for MRI safety in patients with cardiovascular implantable electronic devices","volume":"50","author":"Soto","year":"2020","journal-title":"Nursing"},{"key":"ref_65","doi-asserted-by":"crossref","first-page":"890","DOI":"10.1016\/j.jcmg.2018.09.030","article-title":"CMR and CT of the Patient With Cardiac Devices: Safety, Efficacy, and Optimization Strategies","volume":"12","author":"Symons","year":"2019","journal-title":"JACC Cardiovasc. Imaging"},{"key":"ref_66","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1007\/s11547-019-01103-y","article-title":"In vivo radiation dosimetry and image quality of turbo-flash and retrospective dual-source CT coronary angiography","volume":"125","author":"Schicchi","year":"2020","journal-title":"Radiol. Med."},{"key":"ref_67","doi-asserted-by":"crossref","first-page":"e222827","DOI":"10.1148\/radiol.222827","article-title":"Evolving Developments in Cardiac CT","volume":"307","author":"Dodd","year":"2023","journal-title":"Radiology"},{"key":"ref_68","doi-asserted-by":"crossref","first-page":"102","DOI":"10.21037\/cdt-20-798","article-title":"Myocardial extracellular volume fraction analysis in doxorubicin-induced beagle models: Comparison of dual-energy CT with equilibrium contrast-enhanced single-energy, C.T","volume":"11","author":"Zhou","year":"2021","journal-title":"Cardiovasc. Diagn. Ther."},{"key":"ref_69","doi-asserted-by":"crossref","first-page":"111204","DOI":"10.1016\/j.ejrad.2023.111204","article-title":"Prediction of pancreatic fibrosis by dual-energy CT-derived extracellular volume fraction: Comparison with MRI","volume":"170","author":"Sun","year":"2024","journal-title":"Eur. J. Radiol."},{"key":"ref_70","doi-asserted-by":"crossref","first-page":"1591","DOI":"10.1007\/s10554-022-02532-z","article-title":"Measurement of myocardial extracellular volume using cardiac dual-energy computed tomography in patients with ischaemic cardiomyopathy: A comparison of different methods","volume":"38","author":"Shao","year":"2022","journal-title":"Int. J. Cardiovasc. Imaging"},{"key":"ref_71","doi-asserted-by":"crossref","first-page":"1253","DOI":"10.1007\/s10554-017-1104-4","article-title":"Dual-contrast agent photon-counting computed tomography of the heart: Initial experience","volume":"33","author":"Symons","year":"2017","journal-title":"Int. J. Cardiovasc. Imaging"},{"key":"ref_72","doi-asserted-by":"crossref","first-page":"753","DOI":"10.1007\/s11547-019-01036-6","article-title":"Radiation exposure related to cardiovascular CT examination: Comparison between conventional 64-MDCT and third-generation dual-source MDCT","volume":"124","author":"Agliata","year":"2019","journal-title":"Radiol. Med."},{"key":"ref_73","doi-asserted-by":"crossref","first-page":"20221026","DOI":"10.1259\/bjr.20221026","article-title":"Ultra-low radiation dose and contrast volume CT protocol and TAVI-CT score for TAVI planning and outcome","volume":"96","author":"Fogante","year":"2023","journal-title":"Br. J. Radiol."},{"key":"ref_74","doi-asserted-by":"crossref","first-page":"1024","DOI":"10.1007\/s11547-020-01280-1","article-title":"The sub-millisievert era in CTCA: The technical basis of the new radiation dose approach","volume":"125","author":"Schicchi","year":"2020","journal-title":"Radiol. Med."}],"container-title":["Medicina"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1648-9144\/60\/4\/522\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T14:18:16Z","timestamp":1760105896000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1648-9144\/60\/4\/522"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,3,22]]},"references-count":74,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2024,4]]}},"alternative-id":["medicina60040522"],"URL":"https:\/\/doi.org\/10.3390\/medicina60040522","relation":{},"ISSN":["1648-9144"],"issn-type":[{"value":"1648-9144","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,3,22]]}}}