{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T00:56:04Z","timestamp":1760057764390,"version":"build-2065373602"},"reference-count":32,"publisher":"MDPI AG","issue":"3","license":[{"start":{"date-parts":[[2025,2,25]],"date-time":"2025-02-25T00:00:00Z","timestamp":1740441600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Medicina"],"abstract":"<jats:p>Investigation and evaluation of the first clinical results of the new ablative solid-state laser (AQUARIUZ) regarding clinical outcome, inclusively higher-order aberration and safety. In this case report, three hyperopic patients with six eyes were treated with the new ablative solid-state laser (AQUARIUZ). The LASIK incisions are cut with the Ziemer LDV Z8. All patients were followed for 6 months postoperatively. The treated hyperopia ranged from +0.5 D to +2.75 D. Emmetropia of 0 D was found in four eyes after 6 months. In two eyes there was a slight myopia of \u22120.25 D each, which is also considered emmetropia according to the definition. The aspherically optimized profile of the ablative solid-state laser did not induce a higher-order aberration or spherical aberration in any eye. No eye lost CDVA or UDVA lines after the follow-up period. The safety index was 1 in five eyes and 1.25 in one eye. The findings demonstrate a high level of precision and treatment safety with the new ablative solid-state laser.<\/jats:p>","DOI":"10.3390\/medicina61030395","type":"journal-article","created":{"date-parts":[[2025,2,25]],"date-time":"2025-02-25T03:40:12Z","timestamp":1740454812000},"page":"395","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["First Clinical Results of Hyperopic Eyes Treated with a New Ablative Solid-State Laser"],"prefix":"10.3390","volume":"61","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-1987-6232","authenticated-orcid":false,"given":"Bojan","family":"Pajic","sequence":"first","affiliation":[{"name":"Eye Clinic ORASIS, Swiss Eye Research Foundation, 5734 Reinach, Switzerland"},{"name":"Department of Physics, Faculty of Sciences, University of Novi Sad, Trg Dositeja Obradovica 4, 21000 Novi Sad, Serbia"},{"name":"Division of Ophthalmology, Department of Clinical Neurosciences, Geneva University Hospitals, 1205 Geneva, Switzerland"},{"name":"Faculty of Medicine, University of Geneva, 1205 Geneva, Switzerland"},{"name":"Faculty of Medicine of the Military Medical Academy, University of Defense, 11000 Belgrade, Serbia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8218-4899","authenticated-orcid":false,"given":"Zeljka","family":"Cvejic","sequence":"additional","affiliation":[{"name":"Department of Physics, Faculty of Sciences, University of Novi Sad, Trg Dositeja Obradovica 4, 21000 Novi Sad, Serbia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Anna","family":"Schroeter","sequence":"additional","affiliation":[{"name":"Eye Clinic ORASIS, Swiss Eye Research Foundation, 5734 Reinach, Switzerland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Valentin","family":"Pajic","sequence":"additional","affiliation":[{"name":"Department of Mechanical and Process Engineering, ETH Zuerich, Raemistrasse 101, 8092 Zuerich, Switzerland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9768-8301","authenticated-orcid":false,"given":"Anthia","family":"Papazoglou","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Cantonal Hospital of Aarau, 5001 Aarau, Switzerland"},{"name":"Faculty of Medicine, University of Zurich, 8006 Zurich, Switzerland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Brigitte","family":"Pajic-Eggspuehler","sequence":"additional","affiliation":[{"name":"Eye Clinic ORASIS, Swiss Eye Research Foundation, 5734 Reinach, Switzerland"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2025,2,25]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"209","DOI":"10.1586\/17434440.5.2.209","article-title":"Advances in technologies for laser-assisted in situ keratomileusis (LASIK) surgery","volume":"5","author":"Maldonado","year":"2008","journal-title":"Expert. Rev. Med. Devices"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"1432","DOI":"10.1016\/S0140-6736(06)68275-5","article-title":"Laser Eye Surgery for Refractive Errors","volume":"367","author":"Sakimoto","year":"2006","journal-title":"Lancet"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"710","DOI":"10.1016\/S0002-9394(14)71911-7","article-title":"Excimer Laser Surgery on the Cornea","volume":"96","author":"Trokel","year":"1983","journal-title":"Am. J. Ophthalmol."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"741","DOI":"10.1016\/S0161-6420(85)33962-3","article-title":"Excimer laser ablation of the cornea and lens: Experimental studies","volume":"92","author":"Puliafito","year":"1985","journal-title":"Ophthalmology"},{"key":"ref_5","doi-asserted-by":"crossref","unstructured":"Bagayev, S.N., Razhev, A.M., Zhupikov, A.A., and Kargapoltsev, E.S. (2002, January 9\u201313). The advantages of using the 223 nm compared with 193 nm radiation wavelength for ophthalmic applications. Proceedings of the Seventh International Symposium on Laser Metrology Applied to Science, Industry, and Everyday Life, Novosibirsk, Russia.","DOI":"10.1117\/12.484494"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"2284","DOI":"10.1109\/3.64366","article-title":"Ablation of the Cornea and Synthetic Polymers Using a UV (213 nm) Solid-State Laser","volume":"26","author":"Ren","year":"1990","journal-title":"IEEE J. Quantum Electron."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"373","DOI":"10.1002\/(SICI)1096-9101(1996)18:4<373::AID-LSM6>3.0.CO;2-P","article-title":"Study of corneal ablation with picosecond laser pulses at 211 nm and 263 nm","volume":"18","author":"Hu","year":"1996","journal-title":"Lasers Surg. Med."},{"key":"ref_8","first-page":"2493","article-title":"Ablation rates and surface ultrastructure of 193 nm excimer laser keratectomies","volume":"34","author":"Campos","year":"1993","journal-title":"Investig. Ophthalmol. Vis. Sci."},{"key":"ref_9","first-page":"1283","article-title":"Absorption spectra of Corneas in the Far Ultraviolet Region","volume":"38","author":"Lembares","year":"1997","journal-title":"Investig. Ophthalmol. Vis. Sci."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"477","DOI":"10.3928\/1081-597X-20070501-10","article-title":"Histological changes and unscheduled DNA synthesis in the rabbit cornea following 213-nm, 193-nm, and 266-nm irradiation","volume":"23","author":"Rodger","year":"2007","journal-title":"J. Refract. Surg."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"1415","DOI":"10.1167\/iovs.07-1280","article-title":"Photorefractive keratectomy using solid state laser 213 nm and excimer laser 193 nm: A randomized, contralateral, comparative, experimental study","volume":"49","author":"Tsiklis","year":"2008","journal-title":"Investig. Ophthalmol. Vis. Sci."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"394","DOI":"10.1097\/00003226-200105000-00011","article-title":"Corneal hydration affects ablation during laser in situ keratomileusis surgery","volume":"20","author":"Kim","year":"2001","journal-title":"Cornea"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"533","DOI":"10.1001\/archopht.119.4.533","article-title":"Absorption of 193- and 213-nm laser wavelengths in sodium chloride solution and balanced salt solution","volume":"119","author":"Dair","year":"2001","journal-title":"Arch. Ophthalmol."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"533","DOI":"10.1001\/archopht.119.4.533","article-title":"Investigation of corneal ablation efficiency using ultraviolet 213-nm solid state laser pulses","volume":"119","author":"Dair","year":"2001","journal-title":"Arch. Ophthalmol."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1364\/JOT.76.000263","article-title":"Investigating the action of the 193-nm and 223-nm radiation of excimer lasers on the cornea of the human eye in refractive surgery","volume":"76","author":"Razhev","year":"2009","journal-title":"J. Opt. Technol."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"555","DOI":"10.1364\/AO.12.000555","article-title":"Optical Constants of Water in the 200-nm to 200-\u03bcm Wavelength Region","volume":"12","author":"Hale","year":"1973","journal-title":"Appl. Opt."},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Pajic, B., Pajic-Eggspuehler, B., Cvejic, Z., Rathjen, C., and Ruff, V. (2021). First Clinical Results of a New Generation of Ablative Solid-State Lasers. J. Clin. Med., 10.","DOI":"10.3390\/jcm10112282"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1016\/S0002-9394(14)72896-X","article-title":"Excimer laser ablation rate and corneal hydration","volume":"118","author":"Dougherty","year":"1994","journal-title":"Am. J. Ophthalmol."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"437","DOI":"10.1016\/j.jcrs.2011.09.038","article-title":"Results of laser in situ keratomileusis performed using solid-state laser technology","volume":"38","year":"2012","journal-title":"J. Cataract. Refract. Surg."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"971","DOI":"10.1016\/j.jcrs.2007.02.033","article-title":"One-year results of photorefractive keratectomy and laser in situ keratomileusis for myopia using a 213 nm wavelength solid-state laser","volume":"33","author":"Tsiklis","year":"2007","journal-title":"J. Cataract. Refract. Surg."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"1866","DOI":"10.1016\/j.jcrs.2007.06.042","article-title":"Endothelial cell density after photorefractive keratectomy for moderate myopia using a 213 nm solid-state laser system","volume":"33","author":"Tsiklis","year":"2007","journal-title":"J. Cataract. Refract. Surg."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"276984","DOI":"10.1155\/2013\/276984","article-title":"Long-Term Followup of Laser In Situ Keratomileusis for Hyperopia Using a 213 nm Wavelength Solid-State Laser","volume":"2013","author":"Quito","year":"2013","journal-title":"ISRN Ophthalmol."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"977","DOI":"10.1007\/s00417-012-2166-6","article-title":"Pilot study of hyperopic LASIK using the solid-state laser technology","volume":"251","year":"2013","journal-title":"Graefes Arch. Clin. Exp. Ophthalmol."},{"key":"ref_24","first-page":"226","article-title":"Analysis of the clinical results of the refractive operations performed on the domestic solid-state laser laser system \u201cOLIMP-2000\/213\u2013300 Hz\u201d","volume":"3","author":"Tikhov","year":"2014","journal-title":"Mod. Technol. Cataract. Refract. Surg."},{"key":"ref_25","first-page":"198","article-title":"Analysis of two-year clinical observations of the results of 2200 operations performed on the domestic solid-state laser laser system \u201cOLIMP-2000\/213\u2013300 Hz\u201d","volume":"4","author":"Tikhov","year":"2015","journal-title":"Mod. Technol. Cataract. Refract. Surg."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"746","DOI":"10.1016\/j.jcrs.2011.11.035","article-title":"Refractive outcomes of laser-assisted subepithelial keratectomy for myopia, hyperopia, and astigmatism using a 213 nm wavelength solid-state laser","volume":"38","author":"Shah","year":"2012","journal-title":"J. Cataract. Refract. Surg."},{"key":"ref_27","first-page":"815840","article-title":"Photorefractive Keratectomy with Adjunctive Mitomycin C for Residual Error after Laser-Assisted In Situ Keratomileusis Using the Pulzar 213 nm Solid-State Laser: Early Results","volume":"2013","author":"Evangelista","year":"2013","journal-title":"ISRN Ophthalmol."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"518","DOI":"10.1016\/j.jcrs.2010.09.019","article-title":"Photorefractive keratectomy using a 213 nm wavelength solid-state laser in eyes with previous conductive keratoplasty to treat presbyopia: Early results","volume":"37","author":"Felipe","year":"2011","journal-title":"J. Cataract. Refract. Surg."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"1579","DOI":"10.1016\/j.jcrs.2010.06.027","article-title":"Corneal shaping and ablation of transparent media by femtosecond pulses in deep ultraviolet range","volume":"36","author":"Vengris","year":"2010","journal-title":"J. Cataract. Refract. Surg."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"1287","DOI":"10.1097\/ICO.0000000000000272","article-title":"Influence of the difference between corneal and refractive astigmatism on LASIK outcomes using solid-state technology","volume":"33","author":"Ribera","year":"2014","journal-title":"Cornea"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"611","DOI":"10.3928\/1081-597X-20060601-15","article-title":"One-year clinical results of photorefractive keratectomy with a solid-state laser for refractive surgery","volume":"22","author":"Roszkowska","year":"2006","journal-title":"J. Refract. Surg."},{"key":"ref_32","doi-asserted-by":"crossref","unstructured":"Roszkowska, A.M., Tumminello, G., Licitra, C., Severo, A.A., Inferrera, L., Camellin, U., Schiano-Lomoriello, D., and Aragona, P. (2023). One-Year Results of Photorefractive Keratectomy for Myopia and Compound Myopic Astigmatism with 210 nm Wavelength All Solid-State Laser for Refractive Surgery. J. Clin. Med., 12.","DOI":"10.3390\/jcm12134311"}],"container-title":["Medicina"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1648-9144\/61\/3\/395\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,9]],"date-time":"2025-10-09T16:41:47Z","timestamp":1760028107000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1648-9144\/61\/3\/395"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,2,25]]},"references-count":32,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2025,3]]}},"alternative-id":["medicina61030395"],"URL":"https:\/\/doi.org\/10.3390\/medicina61030395","relation":{},"ISSN":["1648-9144"],"issn-type":[{"type":"electronic","value":"1648-9144"}],"subject":[],"published":{"date-parts":[[2025,2,25]]}}}