{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,27]],"date-time":"2026-10-27T03:59:29Z","timestamp":1793073569619,"version":"4.5.0"},"reference-count":31,"publisher":"MDPI AG","issue":"3","license":[{"start":{"date-parts":[[2025,3,19]],"date-time":"2025-03-19T00:00:00Z","timestamp":1742342400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Medicina"],"abstract":"<jats:p>Background and Objectives: Liver cirrhosis leads to significant hemodynamic changes, particularly portal hypertension and a hyperdynamic circulatory state. Traditional invasive methods for hemodynamic monitoring, while accurate, carry risks such as infection and hemorrhage in a patient predisposed to these conditions. This study evaluates the accuracy of non-invasive continuous hemodynamic monitoring compared to a minimally invasive method in patients with decompensated liver cirrhosis. Materials and Materials and Methods: The study enrolled 51 patients with decompensated liver cirrhosis requiring continuous hemodynamic monitoring in the ICU. Patients underwent simultaneous monitoring via the minimally invasive FloTrac system and continuous non-invasive ClearSight sensor over 24 h, with measurements registered at 6 h intervals. Hemodynamic parameters measured included cardiac output (CO), cardiac index (CI), stroke volume (SV), stroke volume variation (SVV), systemic vascular resistance (SVR), and mean arterial pressure (MAP). Results: Significant discrepancies were observed between the two monitoring methods for most parameters, particularly CO, CI, and MAP, at most time intervals. However, SVV measurements showed no significant differences, indicating similar efficacy in assessing fluid responsiveness between the devices. Conclusions: The ClearSight system, although a valuable non-invasive alternative, demonstrated lower accuracy compared to the FloTrac system for hemodynamic measurements in patients with decompensated liver cirrhosis. Its effectiveness in assessing fluid responsiveness, particularly by SVV, suggests it could play a role in the monitoring of these patients, especially when invasive techniques have increased risks.<\/jats:p>","DOI":"10.3390\/medicina61030536","type":"journal-article","created":{"date-parts":[[2025,3,19]],"date-time":"2025-03-19T07:48:37Z","timestamp":1742370517000},"page":"536","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Continuous Non-Invasive Hemodynamic Monitoring in Cirrhotic Patients\u2014Friend or Foe?"],"prefix":"10.3390","volume":"61","author":[{"given":"Mirela","family":"Crihan","sequence":"first","affiliation":[{"name":"1st Department of Anesthesia and Intensive Care, \u201cIuliu Ha\u0163ieganu\u201d University of Medicine and Pharmacy, 400347 Cluj-Napoca, Romania"},{"name":"Research Association in Anesthesia and Intensive Care (ACATI), 400394 Cluj-Napoca, Romania"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexandru Leonard","family":"Alexa","sequence":"additional","affiliation":[{"name":"1st Department of Anesthesia and Intensive Care, \u201cIuliu Ha\u0163ieganu\u201d University of Medicine and Pharmacy, 400347 Cluj-Napoca, Romania"},{"name":"Research Association in Anesthesia and Intensive Care (ACATI), 400394 Cluj-Napoca, Romania"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0571-1624","authenticated-orcid":false,"given":"Dan","family":"Valean","sequence":"additional","affiliation":[{"name":"Department of Surgery, \u201cIuliu Ha\u0163ieganu\u201d University of Medicine and Pharmacy, 400347 Cluj-Napoca, Romania"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniela","family":"Ionescu","sequence":"additional","affiliation":[{"name":"1st Department of Anesthesia and Intensive Care, \u201cIuliu Ha\u0163ieganu\u201d University of Medicine and Pharmacy, 400347 Cluj-Napoca, Romania"},{"name":"Research Association in Anesthesia and Intensive Care (ACATI), 400394 Cluj-Napoca, Romania"},{"name":"Outcome Research Consortium, Cleveland, OH 44195, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2025,3,19]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1016\/S0720-048X(03)00212-2","article-title":"Liver cirrhosis: Evaluation of haemodynamic changes using an ultrasound contrast agent","volume":"51","author":"Giuseppetti","year":"2004","journal-title":"Eur. J. Radiol."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"384","DOI":"10.1111\/cpf.12425","article-title":"Validation of non-invasive haemodynamic methods in patients with liver disease: The Finometer and the Task Force Monitor","volume":"38","author":"Brittain","year":"2018","journal-title":"Clin. Physiol. Funct. Imaging"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"132","DOI":"10.17085\/apm.22132","article-title":"Cardiovascular manifestation of end-stage liver disease and perioperative echocardiography for liver transplantation: Anesthesiologist\u2019s view","volume":"17","author":"Han","year":"2022","journal-title":"Anesth. Pain. Med."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"451","DOI":"10.1002\/hep.510240226","article-title":"Cirrhotic cardiomyopathy: Getting to the heart of the matter","volume":"24","author":"Ma","year":"1996","journal-title":"Hepatology"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"S121","DOI":"10.1002\/hep.20993","article-title":"The hyperdynamic circulation of chronic liver diseases: From the patient to the molecule","volume":"43","author":"Iwakiri","year":"2006","journal-title":"Hepatology"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"281","DOI":"10.4103\/aca.ACA_120_20","article-title":"Noninvasive continuous arterial pressure monitoring during anesthesia induction in patients undergoing cardiac surgery","volume":"24","author":"Frank","year":"2021","journal-title":"Ann. Card. Anaesth."},{"key":"ref_7","doi-asserted-by":"crossref","unstructured":"Cho, H.Y., Lee, H.J., Hwang, I.E., Lee, H.C., Kim, W.H., and Yang, S.M. (2023). Comparison of invasive and non-invasive measurements of cardiac index and systemic vascular resistance in living-donor liver transplantation: A prospective, observational study. BMC Anesthesiol., 23.","DOI":"10.1186\/s12871-023-02302-x"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"267","DOI":"10.1007\/s10877-012-9375-8","article-title":"Noninvasive continuous hemodynamic monitoring","volume":"26","author":"Truijen","year":"2012","journal-title":"J. Clin. Monit. Comput."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1016\/j.bja.2020.03.013","article-title":"Continuous noninvasive pulse wave analysis using finger cuff technologies for arterial blood pressure and cardiac output monitoring in perioperative and intensive care medicine: A systematic review and meta-analysis","volume":"125","author":"Saugel","year":"2020","journal-title":"Br. J. Anaesth."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"562","DOI":"10.1093\/bja\/aeu447","article-title":"Noninvasive continuous cardiac output monitoring in perioperative and intensive care medicine","volume":"114","author":"Saugel","year":"2015","journal-title":"Br. J. Anaesth."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"340","DOI":"10.1093\/bja\/aeu145","article-title":"Are we ready for the age of non-invasive haemodynamic monitoring?","volume":"113","author":"Saugel","year":"2014","journal-title":"Br. J. Anaesth."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"R191","DOI":"10.1186\/cc12885","article-title":"Perioperative goal-directed hemodynamic therapy based on radial arterial pulse pressure variation and continuous cardiac index trending reduces postoperative complications after major abdominal surgery: A multi-center, prospective, randomized study","volume":"17","author":"Salzwedel","year":"2013","journal-title":"Crit. Care"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"416","DOI":"10.1007\/s12072-008-9100-3","article-title":"Pathogenetic background for treatment of ascites and hepatorenal syndrome","volume":"2","author":"Henriksen","year":"2008","journal-title":"Hepatol. Int."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"7741","DOI":"10.21037\/qims-23-353","article-title":"An improved model based on quantitative features of right liver lobe, maximum varices, and portal vein system measured on magnetic resonance imaging to predict oesophagogastric variceal haemorrhage secondary to hepatitis B-related cirrhosis","volume":"13","author":"Tan","year":"2023","journal-title":"Quant. Imaging Med. Surg."},{"key":"ref_15","first-page":"44","article-title":"Cardiovascular complications of cirrhosis","volume":"85","author":"Henriksen","year":"2009","journal-title":"Postgrad. Med. J."},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"Murata, Y., Imai, T., Takeda, C., Mizota, T., and Kawamoto, S. (2022). Agreement between continuous cardiac output measured by the fourth generation FloTrac\/Vigileo system and a pulmonary artery catheter in adult liver transplantation. Sci. Rep., 12.","DOI":"10.1038\/s41598-022-14988-z"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"632","DOI":"10.1097\/00003643-200408000-00008","article-title":"Pulse dye densitometry using indigo carmine is useful for cardiac output measurement, but not for circulating blood volume measurement","volume":"21","author":"Fujita","year":"2004","journal-title":"Eur. J. Anaesthesiol."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"1047","DOI":"10.4254\/wjh.v8.i25.1047","article-title":"Systemic hemodynamics in advanced cirrhosis: Concerns during perioperative period of liver transplantation","volume":"8","author":"Hori","year":"2016","journal-title":"World J. Hepatol."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"364","DOI":"10.1007\/s00540-019-02632-6","article-title":"Accuracy of the ClearSight\u2122 system in patients undergoing abdominal aortic aneurysm surgery","volume":"33","author":"Sumiyoshi","year":"2019","journal-title":"J. Anesth."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"387","DOI":"10.1007\/s00540-018-2491-y","article-title":"Accuracy and trending ability of the fourth generation FloTrac\/Vigileo System\u2122 in patients undergoing abdominal aortic aneurysm surgery","volume":"32","author":"Maeda","year":"2018","journal-title":"J. Anesth."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"6","DOI":"10.4103\/aca.ACA_41_18","article-title":"Cardiac output monitoring: Technology and choice","volume":"22","author":"Kobe","year":"2019","journal-title":"Ann. Card. Anaesth."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1016\/j.aat.2011.05.001","article-title":"Monitoring fluid responsiveness","volume":"49","author":"Hofer","year":"2011","journal-title":"Acta Anaesthesiol. Taiwan."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"e25152","DOI":"10.1097\/MD.0000000000025152","article-title":"Accuracy of noninvasive continuous arterial pressure monitoring using ClearSight during one-lung ventilation","volume":"100","author":"Lee","year":"2021","journal-title":"Medicine"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"543","DOI":"10.1016\/j.kint.2020.05.031","article-title":"A new channel for the control of renin secretion in juxtaglomerular cells","volume":"98","year":"2020","journal-title":"Kidney Int."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"217","DOI":"10.1016\/j.ahj.2009.06.002","article-title":"Correlation of impedance cardiography with invasive hemodynamic measurements in patients with advanced heart failure: The BioImpedance CardioGraphy (BIG) substudy of the Evaluation Study of Congestive Heart Failure and Pulmonary Artery Catheterization Effectiveness (ESCAPE) Trial","volume":"158","author":"Kamath","year":"2009","journal-title":"Am. Heart J."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"24","DOI":"10.1186\/s13741-022-00248-1","article-title":"A comparison of ClearSight noninvasive cardiac output and pulmonary artery bolus thermodilution cardiac output in cardiac surgery patients","volume":"11","author":"Wang","year":"2022","journal-title":"Perioper. Med."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"1350","DOI":"10.1007\/s00134-016-4375-7","article-title":"Less invasive hemodynamic monitoring in critically ill patients","volume":"42","author":"Teboul","year":"2016","journal-title":"Intensive Care Med."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"275","DOI":"10.1097\/MCC.0000000000001048","article-title":"Which haemodynamic monitoring should we chose for critically ill patients with acute circulatory failure?","volume":"29","author":"Monnet","year":"2023","journal-title":"Curr. Opin. Crit. Care."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"372","DOI":"10.1186\/s13054-022-04255-y","article-title":"A plea for personalization of the hemodynamic management of septic shock","volume":"26","author":"Cecconi","year":"2022","journal-title":"Crit. Care"},{"key":"ref_30","doi-asserted-by":"crossref","unstructured":"Yamada, T., Vacas, S., Gricourt, Y., and Cannesson, M. (2018). Improving Perioperative Outcomes Through Minimally Invasive and Non-invasive Hemodynamic Monitoring Techniques. Front. Med., 5.","DOI":"10.3389\/fmed.2018.00144"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"421","DOI":"10.21037\/atm.2019.07.06","article-title":"Accuracy of non-invasive and minimally invasive hemodynamic monitoring: Where do we stand?","volume":"7","author":"Manolukas","year":"2019","journal-title":"Ann. Transl. Med."}],"container-title":["Medicina"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1648-9144\/61\/3\/536\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,9]],"date-time":"2025-10-09T16:56:25Z","timestamp":1760028985000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1648-9144\/61\/3\/536"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,3,19]]},"references-count":31,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2025,3]]}},"alternative-id":["medicina61030536"],"URL":"https:\/\/doi.org\/10.3390\/medicina61030536","relation":{},"ISSN":["1648-9144"],"issn-type":[{"value":"1648-9144","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,3,19]]}}}