{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,4]],"date-time":"2026-11-04T22:45:26Z","timestamp":1793832326231,"version":"4.6.1"},"reference-count":68,"publisher":"MDPI AG","issue":"7","license":[{"start":{"date-parts":[[2025,6,30]],"date-time":"2025-06-30T00:00:00Z","timestamp":1751241600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Medicina"],"abstract":"<jats:p>Implant primary stability is a prerequisite for obtaining osseointegration and clinical success. Insertion torque (IT) is measured during implant placement and is expressed in Ncm. It represents the quantification of the frictional force experienced by the implant as it progresses apically through a rotational motion along its axis. Usually, to achieve osseointegration, a value within the range of 20\u201340 Ncm is desirable. Below a threshold of 20 Ncm, implants have a decrease in survival rate, while implant stability is guaranteed above 20 Ncm. The main goal of this study was to evaluate whether high values of IT affect osseointegration, implant health, and healing, by highlighting the positive and negative effects of IT &gt; 50 Ncm on peri-implant bone, soft tissues, and long-term stability. This scoping review considered randomized clinical trials, observational studies, and cohort studies. Studies failing to meet the predefined inclusion criteria were excluded from the analysis. The review process adhered to the Preferred Reporting Items for Scoping Reviews (PRISMA-ScR) guidelines. Ultimately, a total of 11 studies were included in the final synthesis. Based on the studies included, the literature suggests that high values of IT guarantee adequate primary stability and better osseointegration. However, high IT is significantly associated with greater marginal bone loss, depending on bone density. Accordingly, IT values &gt; 50 Ncm may provoke greater compressive forces with a negative impact on the jawbone. An elevated strain on the bone can induce necrosis and ischemia, due to an alteration of circulation, which in turn is responsible for marginal bone loss and reduced osseointegration. Lack of osseointegration ultimately leads to an early implant failure. As concerns soft tissue recession, a higher decrease is measured in implants placed with high-insertion torque. Nonetheless, additional clinical trials are warranted to assess long-term outcomes, quantify the incidence of these complications, and explore the impact of emerging clinical variables.<\/jats:p>","DOI":"10.3390\/medicina61071187","type":"journal-article","created":{"date-parts":[[2025,6,30]],"date-time":"2025-06-30T05:00:37Z","timestamp":1751259637000},"page":"1187","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":17,"title":["High Insertion Torque\u2014Clinical Implications and Drawbacks: A Scoping Review"],"prefix":"10.3390","volume":"61","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8270-763X","authenticated-orcid":false,"given":"Mattia","family":"Manfredini","sequence":"first","affiliation":[{"name":"Maxillofacial Surgery and Dental Unit, Fondazione IRCCS C\u00e0 Granda Policlinico, 20112 Milan, Italy"},{"name":"Department of Biomedical, Surgical and Dental Sciences, University of Milan, Via della Commenda 10, 20122 Milan, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7774-169X","authenticated-orcid":false,"given":"Martina","family":"Ghizzoni","sequence":"additional","affiliation":[{"name":"Maxillofacial Surgery and Dental Unit, Fondazione IRCCS C\u00e0 Granda Policlinico, 20112 Milan, Italy"},{"name":"Department of Biomedical, Surgical and Dental Sciences, University of Milan, Via della Commenda 10, 20122 Milan, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Beatrice","family":"Cusaro","sequence":"additional","affiliation":[{"name":"Maxillofacial Surgery and Dental Unit, Fondazione IRCCS C\u00e0 Granda Policlinico, 20112 Milan, Italy"},{"name":"Department of Biomedical, Surgical and Dental Sciences, University of Milan, Via della Commenda 10, 20122 Milan, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mario","family":"Beretta","sequence":"additional","affiliation":[{"name":"Maxillofacial Surgery and Dental Unit, Fondazione IRCCS C\u00e0 Granda Policlinico, 20112 Milan, Italy"},{"name":"Department of Biomedical, Surgical and Dental Sciences, University of Milan, Via della Commenda 10, 20122 Milan, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carlo","family":"Maiorana","sequence":"additional","affiliation":[{"name":"Maxillofacial Surgery and Dental Unit, Fondazione IRCCS C\u00e0 Granda Policlinico, 20112 Milan, Italy"},{"name":"Department of Biomedical, Surgical and Dental Sciences, University of Milan, Via della Commenda 10, 20122 Milan, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1427-071X","authenticated-orcid":false,"given":"Francisley \u00c1vila","family":"Souza","sequence":"additional","affiliation":[{"name":"Department of Diagnosis and Surgery, School of Dentistry, S\u00e3o Paulo State University (UNESP), Ara\u00e7atuba 16015-050, SP, Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3739-1490","authenticated-orcid":false,"given":"Pier Paolo","family":"Poli","sequence":"additional","affiliation":[{"name":"Maxillofacial Surgery and Dental Unit, Fondazione IRCCS C\u00e0 Granda Policlinico, 20112 Milan, Italy"},{"name":"Department of Biomedical, Surgical and Dental Sciences, University of Milan, Via della Commenda 10, 20122 Milan, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2025,6,30]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"399","DOI":"10.1016\/S0022-3913(83)80101-2","article-title":"Osseointegration and its experimental background","volume":"50","author":"Branemark","year":"1983","journal-title":"J. Prosthet. Dent."},{"key":"ref_2","doi-asserted-by":"crossref","unstructured":"Bavetta, G., Randazzo, V., Cavataio, A., Paderni, C., Grassia, V., Dipalma, C., Isacco, C.G., Scarano, A., De Vito, D., and Cantore, S. (2019). A retrospective study on insertion torque and implant stability quotients (ISQ) as stability parameters for immediate loading of implants in fresh extraction sockets. Biomed Res. Int., 2019.","DOI":"10.1155\/2019\/9720419"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1111\/prd.12185","article-title":"Modern implant dentistry based on osseointegration: 50 years of progress, current trends and open questions","volume":"73","author":"Buser","year":"2017","journal-title":"Periodontol. 2000"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"546","DOI":"10.1111\/j.1600-0501.2008.01530.x","article-title":"Immediate non-occlusal vs. early loading of dental implants in partially edentulous patients: A multicentre randomized clinical trial","volume":"19","author":"Galli","year":"2008","journal-title":"Clin. Oral Implant. Res."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"767","DOI":"10.11607\/jomi.3884","article-title":"Meta-analysis of correlations between marginal bone resorption and high insertion torque of dental implants","volume":"30","author":"Li","year":"2015","journal-title":"Int. J. Oral Maxillofac. Implant."},{"key":"ref_6","first-page":"88","article-title":"Implant insertion torque: Its role in achieving primary stability of restorable dental implants","volume":"38","author":"Greenstein","year":"2017","journal-title":"Compend. Contin. Educ. Dent."},{"key":"ref_7","doi-asserted-by":"crossref","unstructured":"Baldi, D., Lombardi, T., Colombo, J., Cervino, G., Perinetti, G., Di Lenarda, R., Stacchi, C., and Tozum, T. (2018). Correlation between insertion torque and implant stability quotient in tapered implants with knife-edge thread design. Biomed Res. Int., 2018.","DOI":"10.1155\/2018\/7201093"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1016\/j.aanat.2014.02.005","article-title":"Efficacy of biologically guided implant site preparation to obtain adequate primary implant stability","volume":"199","author":"Anitua","year":"2015","journal-title":"Ann. Anat."},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Lee, H.C., Tsai, P.I., Huang, C.C., Chen, S.Y., Chao, C.G., and Tsou, N.T. (2017). Numerical method for the design of healing chamber in additive-manufactured dental implants. Biomed Res. Int., 2017.","DOI":"10.1155\/2017\/1970680"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"997","DOI":"10.11607\/jomi.4165","article-title":"Effects of different implant osteotomy preparation sizes on implant stability and bone response in the minipig mandible","volume":"31","author":"Eom","year":"2016","journal-title":"Int. J. Oral Maxillofac. Implant."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"739","DOI":"10.1097\/ID.0000000000000476","article-title":"The effect of osteotomy dimen-sion on implant insertion torque, healing mode, and osseointegration indicators: A study in dogs","volume":"25","author":"Marin","year":"2016","journal-title":"Implant Dent."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"203","DOI":"10.2147\/CCIDE.S174895","article-title":"The effect of implant placement torque on crestal bone remodeling after 1 year of loading","volume":"10","author":"Aldahlawi","year":"2018","journal-title":"Clin. Cosmet. Investig. Dent."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"467","DOI":"10.1111\/j.1600-0501.2008.01679.x","article-title":"Implant micromotionis related to peak insertion torque and bonedensity","volume":"20","author":"Trisi","year":"2009","journal-title":"Clin. Oral Implant. Res."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"277","DOI":"10.1563\/AAID-JOI-D-09-00020.1","article-title":"Initial torque stability of a new bone condensing dental implant. A cohort study of 140 consecutively placed implants","volume":"35","author":"Irinakis","year":"2009","journal-title":"J. Oral Implantol."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"182","DOI":"10.1097\/ID.0b013e31821662b9","article-title":"Peak insertion torque correlated to histologically and clinically evaluated bone density","volume":"20","author":"Makary","year":"2011","journal-title":"Implant Dent."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1111\/j.1708-8208.2003.tb00011.x","article-title":"Immediate functional loading of Br\u00e5nemark system implants with enhanced initial stability: A prospective 1- to 2-year clinical and radiographic study","volume":"5","author":"Calandriello","year":"2003","journal-title":"Clin. Implant Dent. Relat. Res."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"616","DOI":"10.1034\/j.1600-0501.2003.00932.x","article-title":"Correlation of insertion torques with bone mineral density from dental quantitative CT in the mandible","volume":"14","author":"Beer","year":"2003","journal-title":"Clin. Oral Implant. Res."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1111\/j.1708-8208.2000.tb00110.x","article-title":"Measurements com- paring the initial stability of five designs of dental implants: A human cadaver study","volume":"2","author":"Sennerby","year":"2000","journal-title":"Clin. Implant Dent. Relat. Res."},{"key":"ref_19","first-page":"116","article-title":"Immediate loading of 190 endosseous dental implants: A prospective observational study of 40 patients treatments with up to 2-years data","volume":"19","author":"Nikellis","year":"2004","journal-title":"Int. J. Oral Maxillofac. Implant."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"219","DOI":"10.1111\/j.1708-8208.2000.tb00120.x","article-title":"Interaction of force-fitting and surface roughness of implants","volume":"2","author":"Skalak","year":"2000","journal-title":"Clin. Implant Dent. Relat. Res."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"222","DOI":"10.11607\/jomi.2014suppl.g4.1","article-title":"Loading protocols for single-implant crowns: A systematic review and meta-analysis","volume":"29","author":"Benic","year":"2014","journal-title":"Int. J. Oral Maxillofac. Implant."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"508","DOI":"10.1590\/S0103-64402010000600005","article-title":"Influence of high insertion torque on implant placement\u2014An anisotropic bone stress analysis","volume":"21","author":"Rocha","year":"2010","journal-title":"Braz. Dent. J."},{"key":"ref_23","first-page":"769","article-title":"Correlation between placement torque and survival of single-tooth implants","volume":"20","author":"Ottoni","year":"2005","journal-title":"Int. J. Oral Maxillofac. Implant."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"1079","DOI":"10.1016\/j.ijom.2018.04.008","article-title":"Immediate function dental implants inserted with less than 30 N\u00b7cm of torque in full-arch maxillary rehabilitations using the all-on-4 concept: Retrospective study","volume":"47","author":"Lopes","year":"2018","journal-title":"Int. J. Oral Maxillofac. Surg."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1097\/ID.0000000000000714","article-title":"Osseointegration of tissue-level implants with very low insertion torque in soft bone: A clinical study on SLA surface treatment","volume":"27","author":"Verardi","year":"2018","journal-title":"Implant Dent."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"849","DOI":"10.11607\/jomi.5889","article-title":"The influence of low insertion torque on primary stability, implant survival, and maintenance of marginal bone levels: A closed-cohort prospective study","volume":"32","author":"Norton","year":"2017","journal-title":"Int. J. Oral Maxillofac. Implant."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"250","DOI":"10.1097\/ID.0b013e3182938cf1","article-title":"Correlation between insertion torque and survival rates in immediately loaded implants in the maxilla: A retrospective study","volume":"22","author":"Rizkallah","year":"2013","journal-title":"Implant Dent."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"662","DOI":"10.1111\/j.1600-0501.2009.01887.x","article-title":"Factors affecting soft tissue level around anterior maxillary single-tooth implants","volume":"21","author":"Nisapakultorn","year":"2010","journal-title":"Clin. Oral Implant. Res."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"588","DOI":"10.1111\/cid.12337","article-title":"The effect of insertion torque on the clinical outcome of single implants: A randomized clinical trial","volume":"18","author":"Barone","year":"2016","journal-title":"Clin. Implant Dent. Relat. Res."},{"key":"ref_30","first-page":"62","article-title":"The clinical effects of insertion torque for implants placed in healed ridges: A two-year randomized controlled clinical trial","volume":"2","author":"Alfonsi","year":"2016","journal-title":"J. Oral Sci. Rehabil."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"668","DOI":"10.1111\/cid.12042","article-title":"Impact of insertion torque and implant neck design on peri-implant bone level: A randomized split-mouth trial","volume":"16","author":"Hof","year":"2014","journal-title":"Clin. Implant Dent. Relat. Res."},{"key":"ref_32","doi-asserted-by":"crossref","unstructured":"Aromataris, E., and Munn, Z. (2025, April 30). JBI Manual for Evidence Synthesis. Available online: https:\/\/synthesismanual.jbi.global.","DOI":"10.46658\/JBIMES-24-01"},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"467","DOI":"10.7326\/M18-0850","article-title":"PRISMA extension for scoping reviews (PRISMA-ScR): Checklist and explanation","volume":"169","author":"Tricco","year":"2018","journal-title":"Ann. Intern. Med."},{"key":"ref_34","unstructured":"National Heart, Lung, and Blood Institute (2025, April 30). Study Quality Assessment Tool, Available online: https:\/\/www.nhlbi.nih.gov\/health-topics\/study-quality-assessment-tools."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"322","DOI":"10.1111\/cid.12586","article-title":"Longitudinal analysis on the effect of insertion torque on delayed single implants: A 3-year randomized clinical study","volume":"20","author":"Marconcini","year":"2018","journal-title":"Clin. Implant Dent. Relat. Res."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"209","DOI":"10.1615\/JLongTermEffMedImplants.2015012034","article-title":"High insertion torque and peri-implant bone loss: Is there a relationship?","volume":"25","author":"Bidgoli","year":"2015","journal-title":"J. Long. Term. Eff. Med. Implant."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"227","DOI":"10.1111\/j.1708-8208.2011.00351.x","article-title":"Clinical outcome of dental implants placed with high insertion torques (up to 176 Ncm)","volume":"15","author":"Khayat","year":"2013","journal-title":"Clin. Implant Dent. Relat. Res."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"101523","DOI":"10.1016\/j.jormas.2023.101523","article-title":"Investigating the effect of insertion torque on marginal bone loss around dental implants","volume":"124","author":"Oskouei","year":"2023","journal-title":"J. Stomatol. Oral Maxillofac. Surg."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"516","DOI":"10.1016\/j.ijom.2012.10.013","article-title":"Clinical outcome and bone healing of implants placed with high insertion torque: 12-month results from a multicenter controlled cohort study","volume":"42","author":"Grandi","year":"2013","journal-title":"Int. J. Oral Maxillofac. Surg."},{"key":"ref_40","first-page":"CD004345","article-title":"Surgical techniques for the removal of mandibular wisdom teeth","volume":"7","author":"Bailey","year":"2020","journal-title":"Cochrane Database Syst. Rev."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"226","DOI":"10.1034\/j.1600-0501.1997.080309.x","article-title":"Resonance frequency measurements of implant stability in vivo","volume":"8","author":"Meredith","year":"1997","journal-title":"Clin. Oral Implant. Res."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"434","DOI":"10.1038\/sj.bdj.2018.216","article-title":"Diseases associated with mandibular third molar teeth","volume":"224","author":"McArdle","year":"2018","journal-title":"Br. Dent. J."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"1165","DOI":"10.1002\/JPER.18-0024","article-title":"Postoperative infections after dental implant placement: Variables associated with increased risk of failure","volume":"89","author":"Figueiredo","year":"2018","journal-title":"J. Periodontol."},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"635","DOI":"10.1111\/clr.12775","article-title":"Peri-implant bone loss clinical and radiographic evaluation around rough neck and microthread implants: A 5-year study","volume":"29","author":"Javed","year":"2018","journal-title":"Clin. Oral Implant. Res."},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"792","DOI":"10.1111\/cid.12014","article-title":"Reasons for marginal bone loss around oral implants","volume":"14","author":"Qian","year":"2012","journal-title":"Clin. Implant Dent. Relat. Res."},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1111\/j.1600-0501.2005.01210.x","article-title":"Tissue alterations at implant-supported single-tooth replacements: A 1-year prospective clinical study","volume":"17","author":"Cardaropoli","year":"2006","journal-title":"Clin. Oral Implant. Res."},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"1142","DOI":"10.1111\/j.1600-0501.2011.02297.x","article-title":"Impact of implant diameter on bone level changes around platform switched implants: Preliminary results of 18 months follow-up a prospective randomized match-paired controlled trial","volume":"23","author":"Canullo","year":"2012","journal-title":"Clin. Oral Implant. Res."},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"579","DOI":"10.1111\/j.1600-0501.2005.01148.x","article-title":"Influence of alcohol and tobacco habits on peri-implant marginal bone loss: A prospective study","volume":"16","author":"Fauri","year":"2005","journal-title":"Clin. Oral Implant. Res."},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"378","DOI":"10.1111\/clr.12122","article-title":"Marginal bone loss around implants placed in maxillary native bone or grafted sinuses: A retrospective cohort study","volume":"25","author":"Silvestre","year":"2014","journal-title":"Clin. Oral Implant. Res."},{"key":"ref_50","first-page":"442","article-title":"The relationship between insertion torque and removal torque analysed in fresh temporal bone","volume":"6","author":"Ueda","year":"1991","journal-title":"Int. J. Oral Maxillofac. Implant."},{"key":"ref_51","unstructured":"Batth, R.K. (2014). What is the Difference Between Implant Success and Survival and How Will It Change the Future Use of Implants as a Permanent Solution to Tooth Loss?. [Ph.D. Thesis, Boston University Libraries]."},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1097\/ID.0b013e3181676059","article-title":"Implant success, survival, and failure: The International Congress of Oral Implantologists (ICOI) Pisa Consensus Conference","volume":"17","author":"Misch","year":"2008","journal-title":"Implant Dent."},{"key":"ref_53","first-page":"75","article-title":"Pre-operative evaluation of bone quality and bone density using a novel CT\/microCT-based hard-normal-soft classification system","volume":"25","author":"Rebaudi","year":"2010","journal-title":"Int. J. Oral Maxillofac. Implant."},{"key":"ref_54","first-page":"231","article-title":"Implants in the posterior maxilla: A comparative clinical and radiologic study","volume":"20","author":"Rodoni","year":"2005","journal-title":"Int. J. Oral Maxillofac. Implant."},{"key":"ref_55","doi-asserted-by":"crossref","first-page":"1192","DOI":"10.1111\/j.1600-0501.2012.02562.x","article-title":"Influence of implant neck design and implant-abutment connection type on peri-implant health: Radiological study","volume":"24","year":"2013","journal-title":"Clin. Oral Implant. Res."},{"key":"ref_56","doi-asserted-by":"crossref","first-page":"1119","DOI":"10.1111\/clr.12236","article-title":"A systematic review on marginal bone loss around short dental implants (<10 mm) for implant-supported fixed prostheses","volume":"25","author":"Monje","year":"2014","journal-title":"Clin. Oral Implant. Res."},{"key":"ref_57","doi-asserted-by":"crossref","first-page":"729","DOI":"10.1515\/bmt-2020-0039","article-title":"Insertion torque\/time integral as a measure of primary implant stability","volume":"65","author":"Karl","year":"2020","journal-title":"Biomed. Eng. Biomed. Tech."},{"key":"ref_58","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1111\/clr.12316","article-title":"Effect of insertion torque on titanium implant osseointegration: An animal experimental study","volume":"26","author":"Duyck","year":"2015","journal-title":"Clin. Oral Implant. Res."},{"key":"ref_59","first-page":"961","article-title":"Effect of cell seeding and mechanical loading on vascularization and tissue formation inside a scaffold: A mechano-biological model using a lattice approach to simulate cell activity","volume":"5","author":"Checa","year":"2010","journal-title":"Biomech. Model. Mechanobiol."},{"key":"ref_60","doi-asserted-by":"crossref","first-page":"297","DOI":"10.1016\/S0901-5027(99)80163-5","article-title":"A comparison between cutting torque and resonance frequency measurements of maxillary implants: A 20-month clinical study","volume":"28","author":"Friberg","year":"1999","journal-title":"Int. J. Oral Maxillofac. Surg."},{"key":"ref_61","doi-asserted-by":"crossref","unstructured":"Brancacci, E., Garc\u00eda Gonz\u00e1lez, S., Galve-Huertas, A., Bennani, A., Hern\u00e1ndez Alfaro, F., and Aboul-Hosn Centenero, S. (2023). Influence of insertion torque on the surface integrity in different dental implants: An ex vivo descriptive study. Materials, 16.","DOI":"10.3390\/ma16062330"},{"key":"ref_62","doi-asserted-by":"crossref","first-page":"1093","DOI":"10.1302\/0301-620X.84B8.0841093","article-title":"Evolution of the internal fixation of long bone fractures. The scientific basis of biological internal fixation: Choosing a new balance between stability and biology","volume":"84","author":"Perren","year":"2002","journal-title":"J. Bone Jt. Surg. Br."},{"key":"ref_63","doi-asserted-by":"crossref","unstructured":"Do, T.A., Le, H.S., Shen, Y.-W., Huang, H.-L., and Fuh, L.-J. (2020). Risk factors related to late failure of dental implant\u2014A systematic review of recent studies. Int. J. Environ. Res. Public Health, 17.","DOI":"10.3390\/ijerph17113931"},{"key":"ref_64","doi-asserted-by":"crossref","first-page":"e43","DOI":"10.1016\/j.joms.2011.08.006","article-title":"Effect of drilling dimension on implant placement torque and early osseointegration stages: An experimental study in dogs","volume":"70","author":"Campos","year":"2012","journal-title":"J. Oral Maxillofac. Surg."},{"key":"ref_65","doi-asserted-by":"crossref","unstructured":"\u00c7ankaya, A.B., Ak\u00e7ay, \u00c7., Kahraman, N., and K\u00f6seo\u011flu, B.G. (2018). Oral surgical procedures under local anaesthesia in day surgery. BMC Oral Health, 18.","DOI":"10.1186\/s12903-018-0648-6"},{"key":"ref_66","doi-asserted-by":"crossref","unstructured":"Gehrke, S.A., Cortellari, G.C., de Oliveira Fernandes, G.V., Scarano, A., Martins, R.G., Can\u00e7ado, R.M., and Mesquita, A.M.M. (2023). Randomized clinical trial comparing insertion torque and implant stability of two different implant macrogeometries in the initial periods of osseointegration. Medicina, 59.","DOI":"10.3390\/medicina59010168"},{"key":"ref_67","doi-asserted-by":"crossref","first-page":"490","DOI":"10.1016\/j.prosdent.2020.06.012","article-title":"Clinical effect of the high insertion torque on dental implants: A systematic review and meta-analysis","volume":"126","author":"Lemos","year":"2021","journal-title":"J. Prosthet. Dent."},{"key":"ref_68","doi-asserted-by":"crossref","first-page":"101839","DOI":"10.1016\/j.jebdp.2023.101839","article-title":"Limited evidence suggests no correlation between implant insertion torque and implant survival and marginal bone loss","volume":"23","author":"Radi","year":"2023","journal-title":"J. Evid. Based Dent. Pract."}],"container-title":["Medicina"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1648-9144\/61\/7\/1187\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,9]],"date-time":"2025-10-09T18:01:41Z","timestamp":1760032901000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1648-9144\/61\/7\/1187"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,6,30]]},"references-count":68,"journal-issue":{"issue":"7","published-online":{"date-parts":[[2025,7]]}},"alternative-id":["medicina61071187"],"URL":"https:\/\/doi.org\/10.3390\/medicina61071187","relation":{},"ISSN":["1648-9144"],"issn-type":[{"value":"1648-9144","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,6,30]]}}}