{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,12]],"date-time":"2026-11-12T06:49:27Z","timestamp":1794466167755,"version":"4.9.1"},"reference-count":48,"publisher":"MDPI AG","issue":"8","license":[{"start":{"date-parts":[[2025,7,22]],"date-time":"2025-07-22T00:00:00Z","timestamp":1753142400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Medicina"],"abstract":"<jats:p>Background and Objectives: To clinically validate a semi-automatic measurement of Tear Meniscus Central Area (TMCA) to differentiate between Non-Aqueous Deficient Dry Eye (Non-ADDE) and Aqueous Deficient Dry Eye (ADDE) patients. Materials and Methods: 120 volunteer participants were included in the study. Following TFOS DEWS II diagnostic criteria, a battery of tests was conducted for dry eye diagnosis: Ocular Surface Disease Index questionnaire, tear film osmolarity, tear film break-up time, and corneal staining. Additionally, lower tear meniscus videos were captured with Tearscope illumination and, separately, with fluorescein using slit-lamp blue light and a yellow filter. Tear meniscus height was measured from Tearscope videos to differentiate Non-ADDE from ADDE participants, while TMCA was obtained from fluorescein videos. Both parameters were analyzed using the open-source software NIH ImageJ. Results: Receiver Operating Characteristics analysis showed that semi-automatic TMCA evaluation had significant diagnostic capability to differentiate between Non-ADDE and ADDE participants, with an optimal cut-off value to differentiate between the two groups of 54.62 mm2 (Area Under the Curve = 0.714 \u00b1 0.051, p &lt; 0.001; specificity: 71.7%; sensitivity: 68.9%). Conclusions: The semi-automatic TMCA evaluation showed preliminary valuable results as a diagnostic tool for distinguishing between ADDE and Non-ADDE individuals.<\/jats:p>","DOI":"10.3390\/medicina61081322","type":"journal-article","created":{"date-parts":[[2025,7,23]],"date-time":"2025-07-23T08:02:06Z","timestamp":1753257726000},"page":"1322","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Advancing Diagnostics with Semi-Automatic Tear Meniscus Central Area Measurement for Aqueous Deficient Dry Eye Discrimination"],"prefix":"10.3390","volume":"61","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5103-1374","authenticated-orcid":false,"given":"Hugo","family":"Pena-Verdeal","sequence":"first","affiliation":[{"name":"GI-2092 Optometry, Departamento de F\u00edsica Aplicada (\u00c1rea de Optometr\u00eda), Universidade de Santiago de Compostela, 15782 Santiago de Compostela, Spain"},{"name":"AC-24 Optometry, Instituto de Investigaci\u00f3n Sanitaria de Santiago de Compostela (IDIS), 15706 Santiago de Compostela, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7216-4512","authenticated-orcid":false,"given":"Jacobo","family":"Garcia-Queiruga","sequence":"additional","affiliation":[{"name":"GI-2092 Optometry, Departamento de F\u00edsica Aplicada (\u00c1rea de Optometr\u00eda), Universidade de Santiago de Compostela, 15782 Santiago de Compostela, Spain"},{"name":"AC-24 Optometry, Instituto de Investigaci\u00f3n Sanitaria de Santiago de Compostela (IDIS), 15706 Santiago de Compostela, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5032-620X","authenticated-orcid":false,"given":"Belen","family":"Sabucedo-Villamarin","sequence":"additional","affiliation":[{"name":"GI-2092 Optometry, Departamento de F\u00edsica Aplicada (\u00c1rea de Optometr\u00eda), Universidade de Santiago de Compostela, 15782 Santiago de Compostela, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carlos","family":"Garcia-Resua","sequence":"additional","affiliation":[{"name":"GI-2092 Optometry, Departamento de F\u00edsica Aplicada (\u00c1rea de Optometr\u00eda), Universidade de Santiago de Compostela, 15782 Santiago de Compostela, Spain"},{"name":"AC-24 Optometry, Instituto de Investigaci\u00f3n Sanitaria de Santiago de Compostela (IDIS), 15706 Santiago de Compostela, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maria J.","family":"Giraldez","sequence":"additional","affiliation":[{"name":"GI-2092 Optometry, Departamento de F\u00edsica Aplicada (\u00c1rea de Optometr\u00eda), Universidade de Santiago de Compostela, 15782 Santiago de Compostela, Spain"},{"name":"AC-24 Optometry, Instituto de Investigaci\u00f3n Sanitaria de Santiago de Compostela (IDIS), 15706 Santiago de Compostela, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eva","family":"Yebra-Pimentel","sequence":"additional","affiliation":[{"name":"GI-2092 Optometry, Departamento de F\u00edsica Aplicada (\u00c1rea de Optometr\u00eda), Universidade de Santiago de Compostela, 15782 Santiago de Compostela, Spain"},{"name":"AC-24 Optometry, Instituto de Investigaci\u00f3n Sanitaria de Santiago de Compostela (IDIS), 15706 Santiago de Compostela, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2025,7,22]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"132","DOI":"10.1016\/j.preteyeres.2014.11.001","article-title":"Dynamics and function of the tear film in relation to the blink cycle","volume":"45","author":"Braun","year":"2015","journal-title":"Progress Retin. Eye Res."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"282","DOI":"10.1097\/ICL.0b013e31825fed57","article-title":"Daytime variations of tear osmolarity and tear meniscus volume","volume":"38","author":"Li","year":"2012","journal-title":"Eye Contact Lens"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"S1","DOI":"10.1016\/j.jtos.2014.02.002","article-title":"Rethinking dry eye disease: A perspective on clinical implications","volume":"12","author":"Bron","year":"2014","journal-title":"Ocul. Surf."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"276","DOI":"10.1016\/j.jtos.2017.05.008","article-title":"TFOS DEWS II Definition and Classification Report","volume":"15","author":"Craig","year":"2017","journal-title":"Ocul. Surf."},{"key":"ref_5","doi-asserted-by":"crossref","unstructured":"Wolffsohn, J.S., Benitez-Del-Castillo, J., Loya-Garcia, D., Inomata, T., Iyar, G., Liang, L., Pult, H., Sabater, A.L., Starr, C.E., and Vehof, J. (2025). TFOS DEWS III Diagnostic Methodology. Am. J. Ophthalmol., in press.","DOI":"10.1016\/j.ajo.2025.05.033"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"539","DOI":"10.1016\/j.jtos.2017.05.001","article-title":"TFOS DEWS II Diagnostic Methodology report","volume":"15","author":"Wolffsohn","year":"2017","journal-title":"Ocul. Surf."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1016\/j.jtos.2021.05.001","article-title":"Demographic and lifestyle risk factors of dry eye disease subtypes: A cross-sectional study","volume":"21","author":"Wolffsohn","year":"2021","journal-title":"Ocul. Surf."},{"key":"ref_8","first-page":"153","article-title":"Correlation of Dry Eye Workshop Dry Eye Severity Grading System With Tear Meniscus Measurement by Optical Coherence Tomography and Tear Osmolarity","volume":"42","author":"Yildiz","year":"2015","journal-title":"Eye Contact Lens"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"1203","DOI":"10.1080\/02713683.2019.1629598","article-title":"Lower Tear Meniscus Height Measurements Using Keratography and Swept-Source Optical Coherence Tomography and Effect of Fluorescein Instillation Methods","volume":"44","author":"Lam","year":"2019","journal-title":"Curr. Eye Res."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"583","DOI":"10.1080\/08164622.2021.1878854","article-title":"Evaluation of tear meniscus height using different clinical methods","volume":"104","author":"Niedernolte","year":"2021","journal-title":"Clin. Exp. Optom. J. Aust. Optom. Assoc."},{"key":"ref_11","first-page":"15","article-title":"The Role of Different Tear Volume Detection Methods in the Evaluation and Diagnosis of Mild Dry Eye Disease","volume":"11","author":"Wang","year":"2022","journal-title":"Transl. Vis. Sci. Technol."},{"key":"ref_12","doi-asserted-by":"crossref","unstructured":"Sabucedo-Villamarin, B., Pena-Verdeal, H., Garcia-Queiruga, J., Giraldez, M.J., Garcia-Resua, C., and Yebra-Pimentel, E. (2022). Categorization of the Aqueous Deficient Dry Eye by a Cut-Off Criterion of TMH Measured with Tearscope. Life, 12.","DOI":"10.3390\/life12122007"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"731","DOI":"10.1097\/01.opx.0000236810.17338.cf","article-title":"Tear meniscus height, lower punctum lacrimale, and the tear lipid layer in normal aging","volume":"83","author":"Patel","year":"2006","journal-title":"Optom. Vis. Sci."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"1037","DOI":"10.1097\/OPX.0000000000000358","article-title":"The relationship between tear meniscus regularity and conjunctival folds","volume":"91","author":"Bandlitz","year":"2014","journal-title":"Optom. Vis. Sci. Off. Publ. Am. Acad. Optom."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"430","DOI":"10.1080\/08164622.2024.2341833","article-title":"Tear meniscus height agreement and reproducibility between two corneal topographers and spectral-domain optical coherence tomography","volume":"108","author":"Soares","year":"2025","journal-title":"Clin. Exp. Optom."},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"Chen, M., Wei, A., Xu, J., Zhou, X., and Hong, J. (2022). Application of Keratograph and Fourier-Domain Optical Coherence Tomography in Measurements of Tear Meniscus Height. J. Clin. Med., 11.","DOI":"10.3390\/jcm11051343"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1016\/j.clae.2012.10.074","article-title":"Comparison of subjective grading and objective assessment in meibography","volume":"36","author":"Pult","year":"2013","journal-title":"Contact Lens Anterior Eye J. Br. Contact Lens Assoc."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"788","DOI":"10.1097\/OPX.0b013e318253de93","article-title":"Infrared imaging of meibomian gland structure using a novel keratograph","volume":"89","author":"Srinivasan","year":"2012","journal-title":"Optom. Vis. Sci. Off. Publ. Am. Acad. Optom."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"671","DOI":"10.1038\/nmeth.2089","article-title":"NIH Image to ImageJ: 25 years of image analysis","volume":"9","author":"Schneider","year":"2012","journal-title":"Nat. Methods"},{"key":"ref_20","first-page":"3695014","article-title":"Defining the Optimal Region of Interest for Hyperemia Grading in the Bulbar Conjunctiva","volume":"2016","author":"Evans","year":"2016","journal-title":"Comput. Math. Methods Med."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"249","DOI":"10.1016\/j.clae.2016.02.009","article-title":"Interobserver variability of an open-source software for tear meniscus height measurement","volume":"39","author":"Barreira","year":"2016","journal-title":"Contact Lens Anterior Eye J. Br. Contact Lens Assoc."},{"key":"ref_22","first-page":"12","article-title":"RESEARCH GUIDE: Guide to free statistical software: General applications","volume":"4","author":"Stanislaw","year":"2010","journal-title":"OPUS 12 Sci."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"94","DOI":"10.1001\/archophthalmol.2009.356","article-title":"Minimal clinically important difference for the ocular surface disease index","volume":"128","author":"Miller","year":"2010","journal-title":"Arch. Ophthalmol."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"1041","DOI":"10.1185\/03007995.2011.566264","article-title":"Work productivity loss in patients with dry eye disease: An online survey","volume":"27","author":"Patel","year":"2011","journal-title":"Curr. Med. Res. Opin."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"125","DOI":"10.1016\/j.ajo.2016.06.025","article-title":"Development of Definitive and Reliable Grading Scales for Meibomian Gland Dysfunction","volume":"169","author":"Arita","year":"2016","journal-title":"Am. J. Ophthalmol."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"579","DOI":"10.1097\/OPX.0000000000002184","article-title":"Psychometric properties and diagnostic performance of three dry eye questionnaires in Italian: OSDI, OSDI-6, and SPEED","volume":"101","author":"Facchin","year":"2024","journal-title":"Optom. Vis. Sci. Off. Publ. Am. Acad. Optom."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"140","DOI":"10.1111\/opo.12901","article-title":"The validity of point of care tear film osmometers in the diagnosis of dry eye","volume":"42","author":"Tavakoli","year":"2022","journal-title":"Ophthalmic Physiol. Opt."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"811","DOI":"10.1097\/01.ico.0000154378.67495.40","article-title":"The Effect of instilled fluorescein solution volume on the values and repeatability of TBUT measurements","volume":"24","author":"Johnson","year":"2005","journal-title":"Cornea"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"e112","DOI":"10.1111\/aos.12275","article-title":"Comparison of a new portable digital meniscometer and optical coherence tomography in tear meniscus radius measurement","volume":"92","author":"Bandlitz","year":"2014","journal-title":"Acta Ophthalmol."},{"key":"ref_30","unstructured":"Dunn, G. (1989). Design and Analysis of Reliability Studies: The Statistical Evaluation of Measurement Errors, Oxford University Press."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"25","DOI":"10.4097\/kja.21209","article-title":"Receiver operating characteristic curve: Overview and practical use for clinicians","volume":"75","author":"Nahm","year":"2022","journal-title":"Korean J. Anesthesiol."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"1030","DOI":"10.1097\/01.opx.0000192352.78935.e0","article-title":"The agreement and repeatability of tear meniscus height measurement methods","volume":"82","author":"Johnson","year":"2005","journal-title":"Optom. Vis. Sci. Off. Publ. Am. Acad. Optom."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"502","DOI":"10.1038\/eye.2010.228","article-title":"The relationship between clinical signs and dry eye symptoms","volume":"25","author":"Pult","year":"2011","journal-title":"Eye"},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"e1","DOI":"10.1097\/OPX.0000000000000062","article-title":"A new portable digital meniscometer","volume":"91","author":"Bandlitz","year":"2014","journal-title":"Optom. Vis. Sci. Off. Publ. Am. Acad. Optom."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"232","DOI":"10.1016\/j.ajo.2007.04.006","article-title":"Noninvasive interference tear meniscometry in dry eye patients with Sjogren syndrome","volume":"144","author":"Uchida","year":"2007","journal-title":"Am. J. Ophthalmol."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"2722","DOI":"10.1167\/iovs.08-2704","article-title":"Upper and lower tear menisci in the diagnosis of dry eye","volume":"50","author":"Shen","year":"2009","journal-title":"Investig. Ophthalmol. Vis. Sci."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"8013621","DOI":"10.1155\/2016\/8013621","article-title":"Repeatability and Reproducibility of Noninvasive Keratograph 5M Measurements in Patients with Dry Eye Disease","volume":"2016","author":"Tian","year":"2016","journal-title":"J. Ophthalmol."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"747","DOI":"10.1016\/j.jtos.2019.07.002","article-title":"Evaluation of strip meniscometry, tear meniscus height and depth in the diagnosis of dry eye disease in asian Indian eyes","volume":"17","author":"Singh","year":"2019","journal-title":"Ocul. Surf."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"e1089","DOI":"10.1111\/aos.14129","article-title":"Location and pattern of non-invasive keratographic tear film break-up according to dry eye disease subtypes","volume":"97","author":"Kim","year":"2019","journal-title":"Acta Ophthalmol."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1097\/ICO.0000000000001033","article-title":"Assessment of the Tear Meniscus by Strip Meniscometry and Keratograph in Patients With Dry Eye Disease According to the Presence of Meibomian Gland Dysfunction","volume":"36","author":"Lee","year":"2017","journal-title":"Cornea"},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"301","DOI":"10.1016\/j.ajo.2013.09.024","article-title":"Tear meniscus dimensions in tear dysfunction and their correlation with clinical parameters","volume":"157","author":"Tung","year":"2014","journal-title":"Am. J. Ophthalmol."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"3032","DOI":"10.1167\/iovs.06-1507","article-title":"Effect of blinking on tear dynamics","volume":"48","author":"Palakuru","year":"2007","journal-title":"Investig. Ophthalmol. Vis. Sci."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"545","DOI":"10.1038\/eye.2015.277","article-title":"Is optical coherence tomography an effective device for evaluation of tear film meniscus in patients with acne rosacea?","volume":"30","author":"Eroglu","year":"2016","journal-title":"Eye"},{"key":"ref_44","doi-asserted-by":"crossref","unstructured":"Pena-Verdeal, H., Garcia-Queiruga, J., Sabucedo-Villamarin, B., Garcia-Resua, C., Giraldez, M.J., and Yebra-Pimentel, E. (2024). A Comprehensive Study on Tear Meniscus Height Inter-Eye Differences in Aqueous Deficient Dry Eye Diagnosis. J. Clin. Med., 13.","DOI":"10.3390\/jcm13030659"},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"298","DOI":"10.1016\/j.jtos.2023.06.004","article-title":"Longitudinal analysis of variation in status and diagnostic stability of untreated dry eye disease","volume":"29","author":"Giraldez","year":"2023","journal-title":"Ocul. Surf."},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"34","DOI":"10.3341\/kjo.1991.5.1.34","article-title":"Measurement of the tear meniscus height using 0.25% fluorescein sodium","volume":"5","author":"Lim","year":"1991","journal-title":"Korean J. Ophthalmol. KJO"},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"497","DOI":"10.1097\/00003226-200007000-00019","article-title":"The height and radius of the tear meniscus and methods for examining these parameters","volume":"19","author":"Oguz","year":"2000","journal-title":"Cornea"},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"403","DOI":"10.1097\/ICO.0b013e318033c242","article-title":"Quantitative evaluation of tear meniscus height from fluorescein photographs","volume":"26","author":"Kawai","year":"2007","journal-title":"Cornea"}],"container-title":["Medicina"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1648-9144\/61\/8\/1322\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,9]],"date-time":"2025-10-09T18:14:14Z","timestamp":1760033654000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1648-9144\/61\/8\/1322"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,7,22]]},"references-count":48,"journal-issue":{"issue":"8","published-online":{"date-parts":[[2025,8]]}},"alternative-id":["medicina61081322"],"URL":"https:\/\/doi.org\/10.3390\/medicina61081322","relation":{},"ISSN":["1648-9144"],"issn-type":[{"value":"1648-9144","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,7,22]]}}}