{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,10]],"date-time":"2026-10-10T07:25:32Z","timestamp":1791617132142,"version":"4.3.4"},"reference-count":18,"publisher":"MDPI AG","issue":"8","license":[{"start":{"date-parts":[[2025,7,23]],"date-time":"2025-07-23T00:00:00Z","timestamp":1753228800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"European Union\u2019s Horizon 2020 research and innovation program","award":["857287"],"award-info":[{"award-number":["857287"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Medicina"],"abstract":"<jats:p>Background and Objectives: Orbital floor fractures are challenging to treat, due to the complex orbital anatomy and limited surgical access. Emerging technologies\u2014such as virtual surgical planning (VSP), 3D printing, patient-specific implants (PSIs), and intraoperative navigation\u2014offer promising advancements to improve the surgical precision and clinical outcomes. This review systematically evaluates and synthesizes current technological modalities with respect to their accuracy, operative duration, cost-effectiveness, and postoperative functional outcomes. Materials and Methods: A systematic review was conducted according to the PRISMA 2020 guidelines. The PubMed, Scopus, and PRIMO databases were searched for clinical studies published between 2019 and September 2024. Out of 229 articles identified, 9 met the inclusion criteria and were analyzed using the PICO framework. Results: VSP and 3D printing enhanced diagnostics and presurgical planning, offering improved accuracy and reduced planning time. Pre-bent PSIs shaped on 3D models showed superior accuracy, lower operative times, and better cost efficiency compared to intraoperative mesh shaping. Custom-designed PSIs offered high precision and clinical benefit but required a longer production time. Intraoperative navigation improved implant positioning and reduced the complication rates, though a detailed cost analysis remains limited. Conclusions: VSP, 3D printing, and intraoperative navigation significantly improve surgical planning and outcomes in orbital floor reconstruction. Pre-bent PSIs provide a time- and cost-effective solution with strong clinical performance. While customized PSIs offer accuracy, they are less practical in time-sensitive settings. Navigation systems are promising tools that enhance outcomes and may serve as an alternative to custom implants when time or resources are limited.<\/jats:p>","DOI":"10.3390\/medicina61081330","type":"journal-article","created":{"date-parts":[[2025,7,23]],"date-time":"2025-07-23T14:22:44Z","timestamp":1753280564000},"page":"1330","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Emerging Technologies in the Treatment of Orbital Floor Fractures: A Systematic Review"],"prefix":"10.3390","volume":"61","author":[{"given":"Lorena","family":"Helgers","sequence":"first","affiliation":[{"name":"Riga Stradins University, LV-1010 Riga, Latvia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4693-1834","authenticated-orcid":false,"given":"Ilze","family":"Prikule","sequence":"additional","affiliation":[{"name":"Riga Stradins University, LV-1010 Riga, Latvia"},{"name":"Centre of Oral and Maxillofacial Surgery, Pauls Stradins Clinical University Hospital, LV-1002 Riga, Latvia"},{"name":"Institute of Stomatology, Riga Stradins University, LV-1007 Riga, Latvia"},{"name":"Baltic Biomaterial Centre of Excellence, Headquarters at Riga Technical University, LV-1048, Riga, Latvia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Girts","family":"Salms","sequence":"additional","affiliation":[{"name":"Riga Stradins University, LV-1010 Riga, Latvia"},{"name":"Centre of Oral and Maxillofacial Surgery, Pauls Stradins Clinical University Hospital, LV-1002 Riga, Latvia"},{"name":"Institute of Stomatology, Riga Stradins University, LV-1007 Riga, Latvia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0982-4877","authenticated-orcid":false,"given":"Ieva","family":"Bagante","sequence":"additional","affiliation":[{"name":"Riga Stradins University, LV-1010 Riga, Latvia"},{"name":"Centre of Oral and Maxillofacial Surgery, Pauls Stradins Clinical University Hospital, LV-1002 Riga, Latvia"},{"name":"Institute of Stomatology, Riga Stradins University, LV-1007 Riga, Latvia"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2025,7,23]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"2127","DOI":"10.2147\/OPTH.S80463","article-title":"Management of orbital fractures: Challenges and solutions","volume":"9","author":"Boyette","year":"2015","journal-title":"Clin. Ophthalmol."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"373","DOI":"10.1007\/s10006-020-00923-x","article-title":"Health-related quality of life in patients surgically treated for orbital blow-out fracture: A prospective study","volume":"25","author":"Rajantie","year":"2021","journal-title":"Oral Maxillofac. Surg."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"334","DOI":"10.1016\/j.jcms.2023.10.007","article-title":"Epidemiological analysis of patients with isolated blowout fractures of orbital floor: Correlation between demographic characteristics and fracture area","volume":"52","author":"Troise","year":"2024","journal-title":"J. Cranio-Maxillofac. Surg."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"111","DOI":"10.7181\/acfs.2016.17.3.111","article-title":"Orbital Floor Fracture","volume":"17","author":"Kim","year":"2016","journal-title":"Arch. Craniofac. Surg."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"409","DOI":"10.1016\/j.yaoo.2017.03.016","article-title":"Orbital Floor Fracture Management: Toward a Consensus","volume":"2","author":"Somogyi","year":"2017","journal-title":"Adv. Ophthalmol. Optom."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"532","DOI":"10.1016\/j.jcms.2024.02.012","article-title":"Customized orbital implant versus 3D preformed titanium mesh for orbital fracture repair: A retrospective comparative analysis of orbital reconstruction accuracy","volume":"52","author":"Consorti","year":"2024","journal-title":"J. Cranio-Maxillo-Facial Surg."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1016\/j.jcms.2023.01.016","article-title":"Accuracy of intraoperative navigation for orbital fracture repair: A retrospective morphometric analysis","volume":"51","author":"Raveggi","year":"2023","journal-title":"J. Cranio-Maxillo-Facial Surg."},{"key":"ref_8","first-page":"149","article-title":"Comparison of the outcomes of unilateral orbital fracture repair with and without surgical navigation system: Our experience in La Paz University Hospital","volume":"42","author":"Carretero","year":"2020","journal-title":"Rev. Esp. Cir. Oral Maxilofac."},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Probst, F.A., Cornelius, C.P., Otto, S., Malenova, Y., Probst, M., Liokatis, P., and Haidari, S. (2021). Accuracy of free-hand positioned patient specific implants (PSI) in primary reconstruction after inferior and\/or medial orbital wall fractures. Comput. Biol. Med., 137.","DOI":"10.1016\/j.compbiomed.2021.104791"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"433","DOI":"10.1016\/j.ijom.2014.12.003","article-title":"Controversies in orbital reconstruction--II. Timing of post-traumatic orbital reconstruction: A systematic review","volume":"44","author":"Dubois","year":"2015","journal-title":"Int. J. Oral Maxillofac. Surg."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"1275","DOI":"10.1016\/j.joms.2024.07.005","article-title":"Does a Point-of-Care 3-Dimensional Printer Result in a Decreased Length of Surgery for Orbital Fractures?","volume":"82","author":"Amin","year":"2024","journal-title":"J. Oral Maxillofac. Surg."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"n71","DOI":"10.1136\/bmj.n71","article-title":"The PRISMA 2020 statement: An updated guideline for reporting systematic reviews","volume":"372","author":"Page","year":"2021","journal-title":"BMJ"},{"key":"ref_13","unstructured":"(2025, July 15). ROBINS-I Tool. Cochrane Methods. Available online: https:\/\/methods.cochrane.org\/robins-i."},{"key":"ref_14","unstructured":"(2025, July 15). RoB 2: A Revised Cochrane Risk-of-Bias Tool for Randomized Trials. Cochrane Bias. Available online: https:\/\/methods.cochrane.org\/bias\/resources\/rob-2-revised-cochrane-risk-bias-tool-randomized-trials."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"491","DOI":"10.1016\/j.jcms.2024.02.002","article-title":"Comparison of patient specific implant reconstruction vs conventional titanium mesh reconstruction of orbital fractures using a novel method","volume":"52","author":"Krasovsky","year":"2024","journal-title":"J. Cranio-Maxillo-Facial Surg."},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"Sigron, G.R., R\u00fcedi, N., Chammartin, F., Meyer, S., Msallem, B., Kunz, C., and Thieringer, F.M. (2020). Three-Dimensional Analysis of Isolated Orbital Floor Fractures Pre- and Post-Reconstruction with Standard Titanium Meshes and \u201cHybrid\u201d Patient-Specific Implants. J. Clin. Med., 9.","DOI":"10.3390\/jcm9051579"},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Sigron, G.R., Barba, M., Chammartin, F., Msallem, B., Berg, B.I., and Thieringer, F.M. (2021). Functional and Cosmetic Outcome after Reconstruction of Isolated, Unilateral Orbital Floor Fractures (Blow-Out Fractures) with and without the Support of 3D-Printed Orbital Anatomical Models. J. Clin. Med., 10.","DOI":"10.3390\/jcm10163509"},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Consorti, G., Monarchi, G., and Catarzi, L. (2024). Presurgical Virtual Planning and Intraoperative Navigation with 3D-Preformed Mesh: A New Protocol for Primary Orbital Fracture Reconstruction. Life, 14.","DOI":"10.3390\/life14040482"}],"container-title":["Medicina"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1648-9144\/61\/8\/1330\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,9]],"date-time":"2025-10-09T18:14:47Z","timestamp":1760033687000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1648-9144\/61\/8\/1330"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,7,23]]},"references-count":18,"journal-issue":{"issue":"8","published-online":{"date-parts":[[2025,8]]}},"alternative-id":["medicina61081330"],"URL":"https:\/\/doi.org\/10.3390\/medicina61081330","relation":{},"ISSN":["1648-9144"],"issn-type":[{"value":"1648-9144","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,7,23]]}}}