{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,13]],"date-time":"2026-06-13T15:59:16Z","timestamp":1781366356297,"version":"3.54.1"},"reference-count":43,"publisher":"MDPI AG","issue":"8","license":[{"start":{"date-parts":[[2025,8,21]],"date-time":"2025-08-21T00:00:00Z","timestamp":1755734400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Medicina"],"abstract":"<jats:p>Endoscopic ultrasound (EUS)-guided drainage using lumen-apposing metal stents (LAMSs) has become the standard for managing pancreatic fluid collections (PFCs), especially walled-off necrosis (WON). However, LAMS-specific adverse events (AEs), including bleeding, stent occlusion, and infection, remain a concern. To mitigate these complications, some experts advocate placing coaxial double-pigtail plastic stents (DPPSs) within LAMSs. This narrative review critically examines the evidence from retrospective and prospective studies, one RCT, and recent meta-analyses on this combined approach. While the routine use of coaxial double-pigtail plastic stents (DPPSs) within LAMSs is not universally supported, emerging data suggest benefits in select high-risk scenarios, such as large WON, debris-rich cavities, or disconnected pancreatic duct syndrome (DPDS), in which coaxial DPPS within LAMSs can reduce occlusion, infection, and recurrence. In addition, the type of LAMS appears to influence safety outcomes: the SPAXUS stent shows lower bleeding and migration rates than the Hot AXIOS. We propose a pragmatic algorithm for the patient-tailored use of coaxial DPPS and discuss technical innovations to improve outcomes. While evidence is still evolving, personalized strategies and future high-quality studies are needed to define the optimal role of coaxial DPPS within LAMSs in the EUS-guided drainage of PFCs.<\/jats:p>","DOI":"10.3390\/medicina61081500","type":"journal-article","created":{"date-parts":[[2025,8,21]],"date-time":"2025-08-21T14:46:04Z","timestamp":1755787564000},"page":"1500","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["A Critical Narrative Review of Coaxial Double-Pigtail Stenting Within the LAMS in the Management of Pancreatic Fluid Collections"],"prefix":"10.3390","volume":"61","author":[{"given":"Giuseppe","family":"Infantino","sequence":"first","affiliation":[{"name":"Gastroenterology and Endoscopy Unit, IRCCS ISMETT (Istituto Mediterraneo per i Trapianti e Terapie ad Alta Specializzazione), University of Pittsburgh Medical Center Italy (UPMCI), CAP 90127 Palermo, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9261-2087","authenticated-orcid":false,"given":"Gabriele","family":"Rancatore","sequence":"additional","affiliation":[{"name":"Gastroenterology and Endoscopy Unit, IRCCS ISMETT (Istituto Mediterraneo per i Trapianti e Terapie ad Alta Specializzazione), University of Pittsburgh Medical Center Italy (UPMCI), CAP 90127 Palermo, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dario","family":"Quintini","sequence":"additional","affiliation":[{"name":"Gastroenterology and Endoscopy Unit, IRCCS ISMETT (Istituto Mediterraneo per i Trapianti e Terapie ad Alta Specializzazione), University of Pittsburgh Medical Center Italy (UPMCI), CAP 90127 Palermo, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8630-6312","authenticated-orcid":false,"given":"Lucio","family":"Carrozza","sequence":"additional","affiliation":[{"name":"Gastroenterology and Endoscopy Unit, IRCCS ISMETT (Istituto Mediterraneo per i Trapianti e Terapie ad Alta Specializzazione), University of Pittsburgh Medical Center Italy (UPMCI), CAP 90127 Palermo, Italy"},{"name":"Gastroenterology and Endoscopy Unit, Papardo Hospital, CAP 98100 Messina, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4213-0482","authenticated-orcid":false,"given":"Dario","family":"Ligresti","sequence":"additional","affiliation":[{"name":"Gastroenterology and Endoscopy Unit, IRCCS ISMETT (Istituto Mediterraneo per i Trapianti e Terapie ad Alta Specializzazione), University of Pittsburgh Medical Center Italy (UPMCI), CAP 90127 Palermo, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marco","family":"Giacchetto","sequence":"additional","affiliation":[{"name":"Gastroenterology and Endoscopy Unit, IRCCS ISMETT (Istituto Mediterraneo per i Trapianti e Terapie ad Alta Specializzazione), University of Pittsburgh Medical Center Italy (UPMCI), CAP 90127 Palermo, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nicoletta","family":"Belluardo","sequence":"additional","affiliation":[{"name":"Gastroenterology and Endoscopy Unit, IRCCS ISMETT (Istituto Mediterraneo per i Trapianti e Terapie ad Alta Specializzazione), University of Pittsburgh Medical Center Italy (UPMCI), CAP 90127 Palermo, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Giuseppe","family":"Rizzo","sequence":"additional","affiliation":[{"name":"Gastroenterology and Endoscopy Unit, IRCCS ISMETT (Istituto Mediterraneo per i Trapianti e Terapie ad Alta Specializzazione), University of Pittsburgh Medical Center Italy (UPMCI), CAP 90127 Palermo, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elio","family":"D\u2019Amore","sequence":"additional","affiliation":[{"name":"Gastroenterology and Endoscopy Unit, IRCCS ISMETT (Istituto Mediterraneo per i Trapianti e Terapie ad Alta Specializzazione), University of Pittsburgh Medical Center Italy (UPMCI), CAP 90127 Palermo, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9335-6740","authenticated-orcid":false,"given":"Giacomo Emanuele Maria","family":"Rizzo","sequence":"additional","affiliation":[{"name":"Gastroenterology and Endoscopy Unit, IRCCS ISMETT (Istituto Mediterraneo per i Trapianti e Terapie ad Alta Specializzazione), University of Pittsburgh Medical Center Italy (UPMCI), CAP 90127 Palermo, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8791-3395","authenticated-orcid":false,"given":"Ilaria","family":"Tarantino","sequence":"additional","affiliation":[{"name":"Gastroenterology and Endoscopy Unit, IRCCS ISMETT (Istituto Mediterraneo per i Trapianti e Terapie ad Alta Specializzazione), University of Pittsburgh Medical Center Italy (UPMCI), CAP 90127 Palermo, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2025,8,21]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","unstructured":"Dorrell, R., Pawa, S., and Pawa, R. (2021). Endoscopic Management of Pancreatic Fluid Collections. J. Clin. Med., 10.","DOI":"10.3390\/jcm10020284"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"16191","DOI":"10.3748\/wjg.v20.i43.16191","article-title":"Endoscopic ultrasonography-guided endoscopic treatment of pancreatic pseudocysts and walled-off necrosis: New technical developments","volume":"20","author":"Braden","year":"2014","journal-title":"World J. Gastroenterol."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"571","DOI":"10.1097\/MPA.0000000000001798","article-title":"Comparison Between Lumen-Apposing Metal Stents and Plastic Stents in Endoscopic Ultrasound\u2013Guided Drainage of Pancreatic Fluid Collection: A Meta-analysis and Systematic Review","volume":"50","author":"Lyu","year":"2021","journal-title":"Pancreas"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"1167","DOI":"10.1136\/gutjnl-2022-328225","article-title":"EUS-guided drainage of large walled-off pancreatic necroses using plastic versus lumen-apposing metal stents: A single-centre randomised controlled trial","volume":"72","author":"Karstensen","year":"2023","journal-title":"Gut"},{"key":"ref_5","doi-asserted-by":"crossref","unstructured":"Maida, M., Rizzo, G.E.M., Traina, M., Karstensen, J.G., Voermans, R.P., Gornals, J.B., Jagtap, N., Ligresti, D., Carrozza, L., and Rancatore, G. (Endoscopy, 2025). Optimal timing for lumen-apposing metal stent removal following endoscopic ultrasound-guided drainage of pancreatic fluid collections: A systematic review and meta-analysis, Endoscopy, Epub ahead of print.","DOI":"10.1055\/a-2577-3814"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"457","DOI":"10.1016\/j.gie.2021.05.020","article-title":"Lumen-apposing metal stents (with videos)","volume":"94","author":"Law","year":"2021","journal-title":"Gastrointest. Endosc."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"1504","DOI":"10.1111\/j.1440-1746.2011.06771.x","article-title":"Frequency of complications during EUS-guided drainage of pancreatic fluid collections in 148 consecutive patients","volume":"26","author":"Varadarajulu","year":"2011","journal-title":"J. Gastroenterol. Hepatol."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"619","DOI":"10.1111\/den.13428","article-title":"Lumen-apposing metal stents for endoscopic ultrasonography-guided interventions","volume":"31","author":"Bang","year":"2019","journal-title":"Dig. Endosc."},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Binda, C., Fabbri, S., Perini, B., Boschetti, M., Coluccio, C., Giuffrida, P., Gibiino, G., Petraroli, C., and Fabbri, C. (2024). Endoscopic Ultrasound-Guided Drainage of Pancreatic Fluid Collections: Not All Queries Are Already Solved. Medicina, 60.","DOI":"10.3390\/medicina60020333"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"409","DOI":"10.1016\/j.gie.2018.03.018","article-title":"The role of co-axially placed double-pigtail stents within lumen-apposing metal stents in draining pancreatic fluid collections","volume":"88","author":"Wang","year":"2018","journal-title":"Gastrointest. Endosc."},{"key":"ref_11","first-page":"e15981","article-title":"Coaxial Double-Pigtail Stent Placement: A Simple Solution to Decrease Bleeding Risk Associated with Lumen-Apposing Metal Stent?","volume":"13","author":"Aslam","year":"2021","journal-title":"Cureus"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"150","DOI":"10.1016\/j.gie.2017.06.029","article-title":"EUS-guided drainage of peripancreatic fluid collections with lumen-apposing metal stents and plastic double-pigtail stents: Comparison of efficacy and adverse event rates","volume":"87","author":"Lang","year":"2018","journal-title":"Gastrointest. Endosc."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"1022","DOI":"10.1055\/a-0582-9127","article-title":"Safety of lumen-apposing stent with or without coaxial plastic stent for endoscopic ultrasound-guided drainage of pancreatic fluid collections: A retrospective study","volume":"50","author":"Puga","year":"2018","journal-title":"Endoscopy"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"1248","DOI":"10.1016\/j.gie.2017.11.033","article-title":"Safety and efficacy of lumen-apposing metal stents with and without simultaneous double-pigtail plastic stents for draining pancreatic pseudocyst","volume":"87","author":"Aburajab","year":"2018","journal-title":"Gastrointest. Endosc."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"AB920","DOI":"10.1016\/j.gie.2023.04.1423","article-title":"Stent Within a Stent: When Lumen Apposing Metal Stent Meets Its Match in Coaxial Double Pigtail Stent","volume":"97","author":"Aujla","year":"2023","journal-title":"Gastrointest. Endosc."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"104","DOI":"10.1016\/j.gie.2023.09.005","article-title":"Lumen-apposing metal stents with or without coaxial plastic stent placement for the management of pancreatic fluid collections","volume":"99","author":"AbiMansour","year":"2024","journal-title":"Gastrointest. Endosc."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"e70020","DOI":"10.1002\/deo2.70020","article-title":"A novel puzzle ring replacement technique of a lumen-apposing metal stent with a double-pigtail plastic stent to prevent walled-off necrosis recurrence (with video)","volume":"5","author":"Mukai","year":"2025","journal-title":"DEN Open"},{"key":"ref_18","first-page":"620","article-title":"Anchoring lumen-apposing metal stent with coaxial plastic stent for endoscopic ultrasound-guided drainage of pancreatic fluid collections: Any benefit?","volume":"32","author":"Ali","year":"2019","journal-title":"Ann. Gastroenterol."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"53","DOI":"10.4103\/EUS-D-21-00030","article-title":"Double pigtail stent placement as an adjunct to lumen-apposing metal stentsfor drainage of pancreatic fluid collections may not affect outcomes: A multicenter experience","volume":"11","author":"Shamah","year":"2022","journal-title":"Endosc. Ultrasound."},{"key":"ref_20","first-page":"S59","article-title":"Does Co-Axial Plastic Double Pig Tail Stent Placement into Lumen-Apposing Metal Stents Reduce Risks in Eus-Guided Drainage Of Pancreatic Fluid Collections?","volume":"51","author":"Rossi","year":"2019","journal-title":"Endoscopy"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1016\/j.tige.2022.12.001","article-title":"Safety and Efficacy of Lumen-Apposing Metal Stents with and Without Coaxial Plastic Stents for Pancreatic Fluid Collections","volume":"25","author":"Haddad","year":"2023","journal-title":"Tech. Innov. Gastrointest. Endosc."},{"key":"ref_22","first-page":"984","article-title":"Efficacy and safety of lumen-apposing metal stents in endoscopic ultrasound-guided drainage of abdominal fluid collections and the influence of inserting a coaxial double pigtail plastic stent","volume":"10","author":"Adalberto","year":"2022","journal-title":"United Eur. Gastroenterol. J."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"1070","DOI":"10.1016\/j.gie.2022.12.026","article-title":"EUS-guided transluminal drainage using lumen-apposing metal stents with or without coaxial plastic stents for treatment of walled-off necrotizing pancreatitis: A prospective bicentric randomized controlled trial","volume":"97","author":"Vanek","year":"2023","journal-title":"Gastrointest. Endosc."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"59","DOI":"10.14740\/gr1601","article-title":"Lumen-Apposing Metal Stent with and Without Concurrent Double-Pigtail Plastic Stent for Pancreatic Fluid Collections: A Comparative Systematic Review and Meta-Analysis","volume":"16","author":"Beran","year":"2023","journal-title":"Gastroenterol. Res."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"26317745231199364","DOI":"10.1177\/26317745231199364","article-title":"Does a coaxial double pigtail stent reduce adverse events after lumen apposing metal stent placement for pancreatic fluid collections? A systematic review and meta-analysis","volume":"16","author":"Giri","year":"2023","journal-title":"Ther. Adv. Gastrointest. Endosc."},{"key":"ref_26","first-page":"242","article-title":"Endoscopic ultrasound-guided lumen-apposing metal stent with or without coaxial plastic stent for pancreatic fluid collections: A systematic review and meta-analysis comparing safety and efficacy","volume":"37","author":"Gopakumar","year":"2024","journal-title":"Ann. Gastroenterol."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"595","DOI":"10.5946\/ce.2023.297","article-title":"Coaxial plastic stent placement within lumen-apposing metal stents for the management of pancreatic fluid collections: A systemic review and meta-analysis","volume":"57","author":"AbiMansour","year":"2024","journal-title":"Clin. Endosc."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1097\/MCG.0000000000002080","article-title":"EUS-guided Drainage of Pancreatic Fluid Collections Using Lumen Apposing Metal Stents with or Without Coaxial Plastic Stents: A Systematic Review and Meta-analysis","volume":"59","author":"Kamal","year":"2025","journal-title":"J. Clin. Gastroenterol."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"1663","DOI":"10.1016\/j.dld.2024.06.030","article-title":"The i-EUS consensus on the management of pancreatic fluid collections\u2014Part 1","volume":"56","author":"Capurso","year":"2024","journal-title":"Dig. Liver Dis."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"1819","DOI":"10.1016\/j.dld.2024.06.004","article-title":"The 1st i-EUS consensus on the management of pancreatic fluid collections\u2014Part 2","volume":"56","author":"Capurso","year":"2024","journal-title":"Dig. Liver Dis."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"2054","DOI":"10.1136\/gutjnl-2016-312812","article-title":"Lumen-apposing metal stents (LAMS) for pancreatic fluid collection (PFC) drainage: May not be business as usual","volume":"66","author":"Bang","year":"2017","journal-title":"Gut"},{"key":"ref_32","first-page":"1521","article-title":"Increased Incidence of Pseudoaneurysm Bleeding with Lumen-Apposing Metal Stents Compared to Double-Pigtail Plastic Stents in Patients with Peripancreatic Fluid Collections","volume":"16","author":"Brimhall","year":"2018","journal-title":"Clin. Gastroenterol. Hepatol. Off. Clin. Pract. J. Am. Gastroenterol. Assoc."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"231","DOI":"10.4103\/EUS-D-21-00096","article-title":"Adverse events associated with AXIOS stents: Insights from the manufacturer and user facility device experience database","volume":"11","author":"Ramai","year":"2022","journal-title":"Endosc. Ultrasound"},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1002\/jhbp.1180","article-title":"A novel bipolar electrocautery-enhanced delivery system with a lumen-apposing metal stent for EUS-guided drainage: A porcine study","volume":"30","author":"Jo","year":"2023","journal-title":"J. Hepato-Biliary-Pancreat. Sci."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"E998","DOI":"10.1055\/a-1838-2683","article-title":"EUS-guided biliary drainage with a novel electrocautery-enhanced lumen apposing metal stent as first approach for distal malignant biliary obstruction: A prospective study","volume":"10","author":"Mangiavillano","year":"2022","journal-title":"Endosc. Int. Open"},{"key":"ref_36","first-page":"391","article-title":"Prospective multicenter international study on the outcomes of a newly developed self-approximating lumen-apposing metallic stent for drainage of pancreatic fluid collections and endoscopic necrosectomy","volume":"32","author":"Teoh","year":"2020","journal-title":"Dig. Endosc. Off. J. Jpn. Gastroenterol. Endosc. Soc."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"84","DOI":"10.4103\/EUS-D-21-00033","article-title":"Preliminary experience of EUS-guided pancreatic fluid collections drainage using a new lumen-apposing metal stent mounted on a cautery device","volume":"11","author":"Larghi","year":"2022","journal-title":"Endosc. Ultrasound"},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"249","DOI":"10.1055\/a-2219-3179","article-title":"Lumen-apposing metal stents for the treatment of pancreatic and peripancreatic fluid collections and bleeding risk: A propensity matched study","volume":"56","author":"Mangiavillano","year":"2024","journal-title":"Endoscopy"},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"282","DOI":"10.1055\/a-2461-3773","article-title":"Safety and efficacy of lumen-apposing metal stents for endoscopic ultrasound-guided drainage of pancreatic fluid collections: A systematic review and meta-analysis","volume":"57","author":"Singh","year":"2025","journal-title":"Endoscopy"},{"key":"ref_40","first-page":"1234","article-title":"Long-term transmural drainage of pancreatic fluid collections with double pigtail stents following lumen-apposing metal stent placement improves recurrence-free survival in disconnected pancreatic duct syndrome","volume":"34","author":"Pawa","year":"2022","journal-title":"Dig. Endosc. Off. J. Jpn. Gastroenterol. Endosc. Soc."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"1275","DOI":"10.1016\/j.cgh.2020.07.022","article-title":"Importance of Disconnected Pancreatic Duct Syndrome in Recurrence of Pancreatic Fluid Collections Initially Drained Using Lumen-Apposing Metal Stents","volume":"19","author":"Bang","year":"2021","journal-title":"Clin. Gastroenterol. Hepatol."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"E353","DOI":"10.1055\/a-2587-8730","article-title":"Innovative coaxial plastic stent within a lumen-apposing metal stent to prevent recurrence of pancreatic fluid collection","volume":"57","author":"Kato","year":"2025","journal-title":"Endoscopy"},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"362","DOI":"10.1016\/j.gie.2025.01.019","article-title":"Predicting the need for step-up after EUS-guided drainage of peripancreatic fluid collections, including Quadrant-Necrosis-Infection score validation: A prospective cohort study","volume":"102","author":"Vanella","year":"2025","journal-title":"Gastrointest. Endosc."}],"container-title":["Medicina"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1648-9144\/61\/8\/1500\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,9]],"date-time":"2025-10-09T18:33:09Z","timestamp":1760034789000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1648-9144\/61\/8\/1500"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,8,21]]},"references-count":43,"journal-issue":{"issue":"8","published-online":{"date-parts":[[2025,8]]}},"alternative-id":["medicina61081500"],"URL":"https:\/\/doi.org\/10.3390\/medicina61081500","relation":{},"ISSN":["1648-9144"],"issn-type":[{"value":"1648-9144","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,8,21]]}}}