{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,24]],"date-time":"2026-09-24T22:18:30Z","timestamp":1790288310640,"version":"4.1.0"},"reference-count":21,"publisher":"MDPI AG","issue":"5","license":[{"start":{"date-parts":[[2026,5,17]],"date-time":"2026-05-17T00:00:00Z","timestamp":1778976000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Medicina"],"abstract":"<jats:p>Background and Objectives: Minimally invasive cervical spine surgery (MIS-CSS) relies heavily on intraoperative fluoroscopic imaging, raising concerns about radiation exposure to patients and surgical staff. Unlike lumbar MIS, cervical-specific radiation exposure has not been systematically reviewed, despite distinct anatomical considerations, including proximity to the thyroid gland and lens of the eye. This review aims to quantify intraoperative radiation exposure during MIS cervical spine procedures and evaluate available dose-reduction strategies. Materials and Methods: A systematic literature search was conducted across PubMed\/MEDLINE, Scopus, and Google Scholar in April 2026 following PRISMA 2020 guidelines. Studies reporting original quantitative radiation data during minimally invasive cervical spine procedures in adult patients (\u226510 patients) were included. Quality was assessed using the MINORS tool and the JBI checklist. Results: Seven studies encompassing 380 patients were included. Procedures comprised ACDF (four studies), minimally invasive posterior cervical laminoforaminotomy (two studies), and CT-navigated cervical instrumentation (one study). Patient effective doses during ACDF ranged from 0.015 to 1.3 mSv, with thyroid doses of 0.194\u20130.290 mGy. Standalone ACDF reduced patient dose by 36\u201358% compared to plated ACDF (p &lt; 0.001). Navigation-assisted posterior cervical foraminotomy achieved a median fluoroscopy time of 10 s with negligible staff exposure. Surgeon per-procedure exposure during cervical discectomy (chest 0.122 \u00b5Sv, lens 3.1 \u00b5Sv, hands 7.1 \u00b5Sv) was approximately half that of lumbar discectomy. Conclusions: Radiation doses during individual MIS cervical procedures appear to be within occupational safety limits, though the current evidence is insufficient to establish definitive dose thresholds. Standalone implant designs and intraoperative navigation represent effective, complementary dose-reduction strategies. Standardized prospective research is needed to establish cervical-specific radiation safety benchmarks.<\/jats:p>","DOI":"10.3390\/medicina62050977","type":"journal-article","created":{"date-parts":[[2026,5,27]],"date-time":"2026-05-27T10:19:52Z","timestamp":1779877192000},"page":"977","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Radiation Exposure in Minimally Invasive Cervical Spine Surgery: A Systematic Review"],"prefix":"10.3390","volume":"62","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4422-2997","authenticated-orcid":false,"given":"Dong Hun","family":"Kim","sequence":"first","affiliation":[{"name":"Department of Neurosurgery, Bucheon St. Mary\u2019s Hospital, The Catholic University of Korea, Seoul 14647, Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2184-0044","authenticated-orcid":false,"given":"Jung-Woo","family":"Hur","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Eunpyeong St. Mary\u2019s Hospital, The Catholic University of Korea, Seoul 03312, Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6453-0439","authenticated-orcid":false,"given":"Jae Taek","family":"Hong","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Eunpyeong St. Mary\u2019s Hospital, The Catholic University of Korea, Seoul 03312, Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2026,5,17]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"1738","DOI":"10.1007\/s11999-014-3503-3","article-title":"Does Less Invasive Spine Surgery Result in Increased Radiation Exposure? A Systematic Review","volume":"472","author":"Yu","year":"2014","journal-title":"Clin. Orthop. Relat. Res."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"102795","DOI":"10.1016\/j.otsr.2020.102795","article-title":"Minimising Radiation Exposure to the Surgeon in Minimally Invasive Spine Surgeries: A Systematic Review of 15 Studies","volume":"107","author":"Arif","year":"2021","journal-title":"Orthop. Traumatol. Surg. Res."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"S86","DOI":"10.1093\/neuros\/nyw077","article-title":"Navigation and Robotics in Spinal Surgery: Where Are We Now?","volume":"80","author":"Overley","year":"2017","journal-title":"Neurosurgery"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"100","DOI":"10.21037\/atm.2018.02.09","article-title":"Percutaneous endoscopic cervical discectomy: A technical review","volume":"6","author":"Lin","year":"2018","journal-title":"Ann. Transl. Med."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"1337","DOI":"10.1016\/j.wneu.2014.07.041","article-title":"Radiation Safety and Spine Surgery: Systematic Review of Exposure Limits and Methods to Minimize Radiation Exposure","volume":"82","author":"Srinivasan","year":"2014","journal-title":"World Neurosurg."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"84","DOI":"10.21037\/atm-20-1052","article-title":"Intraoperative Risks of Radiation Exposure for the Surgeon and Patient","volume":"9","author":"Jenkins","year":"2021","journal-title":"Ann. Transl. Med."},{"key":"ref_7","unstructured":"International Commission on Radiological Protection (ICRP) (2007). The 2007 Recommendations of the International Commission on Radiological Protection. ICRP Publication 103. Ann. ICRP, 37, 1\u2013332."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"498","DOI":"10.1093\/occmed\/kqi048","article-title":"Increased Cancer Risk Among Surgeons in an Orthopaedic Hospital","volume":"55","author":"Mastrangelo","year":"2005","journal-title":"Occup. Med."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"247","DOI":"10.1016\/j.nec.2013.12.004","article-title":"Minimizing radiation exposure in minimally invasive spine surgery: Lessons learned from neuroendovascular surgery","volume":"25","author":"Patel","year":"2014","journal-title":"Neurosurg. Clin. N. Am."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"1279","DOI":"10.1097\/BRS.0000000000004381","article-title":"Robotics Reduces Radiation Exposure in Minimally Invasive Lumbar Fusion Compared with Navigation","volume":"47","author":"Shahi","year":"2022","journal-title":"Spine"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"333","DOI":"10.1177\/15563316211026652","article-title":"Cervical Spine Navigation and Enabled Robotics: A New Frontier in Minimally Invasive Surgery","volume":"17","author":"Lebl","year":"2021","journal-title":"HSS J."},{"key":"ref_12","first-page":"386","article-title":"Fluoroscopic Exposure in Modern Spinal Surgery","volume":"77","author":"Fransen","year":"2011","journal-title":"Acta Orthop. Belg."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"n71","DOI":"10.1136\/bmj.n71","article-title":"The PRISMA 2020 Statement: An Updated Guideline for Reporting Systematic Reviews","volume":"372","author":"Page","year":"2021","journal-title":"BMJ"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"712","DOI":"10.1046\/j.1445-2197.2003.02748.x","article-title":"Methodological Index for Non-Randomized Studies (MINORS): Development and Validation of a New Instrument","volume":"73","author":"Slim","year":"2003","journal-title":"ANZ J. Surg."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1097\/BSD.0000000000001143","article-title":"Technique, time demand, radiation exposure, and outcomes of skin-anchored intraoperative 3D navigation in minimally invasive posterior cervical laminoforaminotomy","volume":"35","author":"Vaishnav","year":"2022","journal-title":"Clin. Spine Surg."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"696","DOI":"10.21037\/jss.2018.06.17","article-title":"Decreasing Radiation Dose with FluoroLESS Standalone Anterior Cervical Fusion","volume":"4","author":"Chin","year":"2018","journal-title":"J. Spine Surg."},{"key":"ref_17","first-page":"575","article-title":"Patient Dose in Fluoroscopically Guided Cervical Discectomy and Fusion","volume":"174","author":"Metaxas","year":"2017","journal-title":"Radiat. Prot. Dosim."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"164","DOI":"10.1093\/rpd\/ncad286","article-title":"Assessment of Organ Doses in Patients Undergoing ACDF Utilising VirtualDose-IR Software","volume":"200","author":"Metaxas","year":"2024","journal-title":"Radiat. Prot. Dosim."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"329","DOI":"10.1016\/j.wneu.2016.02.021","article-title":"Assessment of the Radiation Exposure of Surgeons and Patients During a Lumbar Microdiskectomy and a Cervical Microdiskectomy: A French Prospective Multicenter Study","volume":"89","author":"Grelat","year":"2016","journal-title":"World Neurosurg."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"2960","DOI":"10.1111\/os.13476","article-title":"Minimally Invasive Full-Endoscopic Posterior Cervical Foraminotomy and Discectomy: Introducing a Useful Localization Technique","volume":"14","author":"Zhong","year":"2022","journal-title":"Orthop. Surg."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"343","DOI":"10.1016\/j.spinee.2015.11.020","article-title":"Patient and surgeon radiation exposure during spinal instrumentation using intraoperative computed tomography-based navigation","volume":"16","author":"Mendelsohn","year":"2016","journal-title":"Spine J."}],"container-title":["Medicina"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1648-9144\/62\/5\/977\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,27]],"date-time":"2026-05-27T10:29:59Z","timestamp":1779877799000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1648-9144\/62\/5\/977"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5,17]]},"references-count":21,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2026,5]]}},"alternative-id":["medicina62050977"],"URL":"https:\/\/doi.org\/10.3390\/medicina62050977","relation":{},"ISSN":["1648-9144"],"issn-type":[{"value":"1648-9144","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,5,17]]}}}