{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,26]],"date-time":"2026-06-26T10:53:05Z","timestamp":1782471185592,"version":"3.54.5"},"reference-count":55,"publisher":"MDPI AG","issue":"7","license":[{"start":{"date-parts":[[2026,6,26]],"date-time":"2026-06-26T00:00:00Z","timestamp":1782432000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Medicina"],"abstract":"<jats:p>Carotid artery stenting (CAS) is an established revascularization option for patients with carotid disease at high surgical risk. Periprocedural cerebral embolization remains a clinical concern, and plaque prolapse, the extrusion of atherosclerotic material through the stent struts into the lumen, has emerged as an actionable mechanism directly linked to embolic events and adverse neurological outcomes. This narrative review provides a structured, practice-oriented framework addressing one specific question: how can plaque prolapse be prevented during CAS? Drawing on prospective registries, comparative cohort studies and intravascular imaging analyses based on optical coherence tomography (OCT) and intravascular ultrasound (IVUS), we discuss the main determinants of prolapse risk, plaque morphology, procedural variables and device selection, converging on dual-layer micromesh stent (DLMS) technology as the most advanced device-based solution available. Pooled clinical data indicate a 30-day stroke rate of approximately 1.4% when DLMSs are used in combination with embolic protection, and OCT studies confirm reduced prolapse compared with single-layer stents. Prevention requires an integrated strategy combining lesion-specific characterisation, optimised technique and tailored device selection, while standardised imaging definitions and adequately powered randomised trials with hard clinical endpoints remain research priorities.<\/jats:p>","DOI":"10.3390\/medicina62071235","type":"journal-article","created":{"date-parts":[[2026,6,26]],"date-time":"2026-06-26T08:43:57Z","timestamp":1782463437000},"page":"1235","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Plaque Prolapse in Carotid Artery Stenting: Mechanisms, Imaging and Device-Based Prevention"],"prefix":"10.3390","volume":"62","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2580-1704","authenticated-orcid":false,"given":"Luca","family":"Galassi","sequence":"first","affiliation":[{"name":"Postgraduate School of Vascular and Endovascular Surgery, University of Milan, Via Festa del Perdono 7, 20122 Milan, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2559-3968","authenticated-orcid":false,"given":"Leonardo","family":"Pasquetti","sequence":"additional","affiliation":[{"name":"Vascular Surgery, Department of Medicine, Surgery and Neuroscience, University of Siena, Viale Bracci, 53100 Siena, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0006-0970-3409","authenticated-orcid":false,"given":"Federica","family":"Facchinetti","sequence":"additional","affiliation":[{"name":"School of Medicine and Surgery, University of Milan-Bicocca, Via GB Pergolesi 39, 20900 Monza, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0001-9816-5924","authenticated-orcid":false,"given":"Rebecca","family":"Magugliani","sequence":"additional","affiliation":[{"name":"Cardiotoracovascular Research Unit, IRCCS Galeazzi Sant\u2019Ambrogio Hospital, Via Cristina Belgioioso 57, 20157 Milan, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0004-3306-2061","authenticated-orcid":false,"given":"Elena","family":"Goldoni","sequence":"additional","affiliation":[{"name":"School of Medicine and Surgery, University of Milan, Via Festa del Perdono 7, 20122 Milan, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6619-0159","authenticated-orcid":false,"given":"Edoardo","family":"Pasqui","sequence":"additional","affiliation":[{"name":"Vascular Surgery, Department of Medicine, Surgery and Neuroscience, University of Siena, Viale Bracci, 53100 Siena, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9680-6014","authenticated-orcid":false,"given":"Giovanni","family":"Nano","sequence":"additional","affiliation":[{"name":"Vascular Surgery Unit, IRCCS Policlinico San Donato, San Donato Milanese, 20097 Milan, Italy"},{"name":"Department of Biomedical Sciences for Health, University of Milan, Via Festa del Perdono 7, 20122 Milan, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2451-8501","authenticated-orcid":false,"given":"Gianmarco","family":"de Donato","sequence":"additional","affiliation":[{"name":"Vascular Surgery, Department of Medicine, Surgery and Neuroscience, University of Siena, Viale Bracci, 53100 Siena, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2026,6,26]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"1105","DOI":"10.1161\/STROKEAHA.108.532218","article-title":"Prevalence of asymptomatic carotid artery stenosis according to age and sex","volume":"40","author":"Greving","year":"2009","journal-title":"Stroke"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1016\/j.ejvs.2022.04.011","article-title":"Editor\u2019s choice, European Society for Vascular Surgery (ESVS) 2023 clinical practice guidelines on the management of atherosclerotic carotid and vertebral artery disease","volume":"65","author":"Naylor","year":"2023","journal-title":"Eur. J. Vasc. Endovasc. Surg."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"705","DOI":"10.1007\/s00270-024-03707-y","article-title":"CIRSE Standards of Practice on carotid artery stenting","volume":"47","author":"Spiliopoulos","year":"2024","journal-title":"Cardiovasc. Interv. Radiol."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1093\/cvr\/cvad135","article-title":"Stroke risk management in carotid atherosclerotic disease: A clinical consensus statement of the ESC Council on Stroke and the ESC Working Group on Aorta and Peripheral Vascular Diseases","volume":"121","author":"Musialek","year":"2025","journal-title":"Cardiovasc. Res."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"219","DOI":"10.1056\/NEJMoa2508800","article-title":"Medical management and revascularization for asymptomatic carotid stenosis","volume":"394","author":"Brott","year":"2025","journal-title":"N. Engl. J. Med."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"824","DOI":"10.1016\/j.jcin.2017.01.029","article-title":"Carotid artery stenting: Investigation of plaque protrusion incidence and prognosis","volume":"10","author":"Kotsugi","year":"2017","journal-title":"JACC Cardiovasc. Interv."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"686","DOI":"10.1016\/j.jvs.2016.09.057","article-title":"Volume of subclinical embolic infarct correlates to long-term cognitive changes after carotid artery stenting","volume":"65","author":"Zhou","year":"2017","journal-title":"J. Vasc. Surg."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"579","DOI":"10.1016\/j.ejvs.2013.03.005","article-title":"Optical coherence tomography after carotid stenting: Rate of stent malapposition, plaque prolapse and fibrous cap rupture according to stent design","volume":"45","author":"Setacci","year":"2013","journal-title":"Eur. J. Vasc. Endovasc. Surg."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"303","DOI":"10.1583\/12-3871R.1","article-title":"Safety and feasibility of intravascular optical coherence tomography using a nonocclusive technique to evaluate carotid plaques before and after stent deployment","volume":"19","author":"Setacci","year":"2012","journal-title":"J. Endovasc. Ther."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"1852","DOI":"10.1161\/CIRCRESAHA.114.302721","article-title":"Mechanisms of plaque formation and rupture","volume":"114","author":"Bentzon","year":"2014","journal-title":"Circ. Res."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"1273","DOI":"10.21037\/atm-20-1974","article-title":"Carotid intraplaque haemorrhage: Pathogenesis, histological classification, imaging methods and clinical value","volume":"8","author":"Mura","year":"2020","journal-title":"Ann. Transl. Med."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"376","DOI":"10.1097\/MCA.0000000000000380","article-title":"Thin-cap fibroatheroma and large calcification at the proximal stent edge correlate with a high proportion of uncovered stent struts in the chronic phase","volume":"27","author":"Ueda","year":"2016","journal-title":"Coron. Artery Dis."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"2621","DOI":"10.1161\/STROKEAHA.123.042807","article-title":"Extracranial carotid plaque calcification and cerebrovascular ischemia: A systematic review and meta-analysis","volume":"54","author":"Homssi","year":"2023","journal-title":"Stroke"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"1599","DOI":"10.1016\/j.jacc.2021.02.016","article-title":"Eruptive calcified nodules as a potential mechanism of acute coronary thrombosis and sudden death","volume":"77","author":"Torii","year":"2021","journal-title":"J. Am. Coll. Cardiol."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"1639","DOI":"10.1016\/j.jvs.2020.08.155","article-title":"Comparison of open- and closed-cell stent design outcomes after carotid artery stenting in the Vascular Quality Initiative","volume":"73","author":"Faateh","year":"2021","journal-title":"J. Vasc. Surg."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"523","DOI":"10.1177\/1526602818783505","article-title":"Effect of open- vs closed-cell stent design on periprocedural outcomes and restenosis after carotid artery stenting: A systematic review and comprehensive meta-analysis","volume":"25","author":"Texakalidis","year":"2018","journal-title":"J. Endovasc. Ther."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"171","DOI":"10.23736\/S0392-9590.20.04316-3","article-title":"OCTOPVS Study","volume":"39","author":"Setacci","year":"2020","journal-title":"Int. Angiol."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"1063","DOI":"10.1007\/s00330-022-09024-7","article-title":"State-of-the-art CT and MR imaging and assessment of atherosclerotic carotid artery disease: Standardization of scanning protocols and measurements\u2014A consensus document by the European Society of Cardiovascular Radiology (ESCR)","volume":"33","author":"Saba","year":"2023","journal-title":"Eur. Radiol."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"1088","DOI":"10.1007\/s00330-022-09025-6","article-title":"State-of-the-art CT and MR imaging and assessment of atherosclerotic carotid artery disease: The reporting\u2014A consensus document by the European Society of Cardiovascular Radiology (ESCR)","volume":"33","author":"Saba","year":"2023","journal-title":"Eur. Radiol."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"559","DOI":"10.1016\/S1474-4422(19)30035-3","article-title":"Imaging biomarkers of vulnerable carotid plaques for stroke risk prediction and their potential clinical implications","volume":"18","author":"Saba","year":"2019","journal-title":"Lancet Neurol."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"466","DOI":"10.1016\/j.ultrasmedbio.2019.10.020","article-title":"Contrast-enhanced ultrasound to assess carotid intraplaque neovascularization","volume":"46","author":"Schinkel","year":"2020","journal-title":"Ultrasound Med. Biol."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"809","DOI":"10.1111\/ene.14157","article-title":"Plaque neovascularization detected with contrast-enhanced ultrasound predicts ischaemic stroke recurrence in patients with carotid atherosclerosis","volume":"27","author":"Casoni","year":"2020","journal-title":"Eur. J. Neurol."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"2366","DOI":"10.1161\/01.ATV.0000240518.90124.57","article-title":"In vivo characterization and quantification of atherosclerotic carotid plaque components with multidetector computed tomography and histopathological correlation","volume":"26","author":"Ouhlous","year":"2006","journal-title":"Arterioscler. Thromb. Vasc. Biol."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"880","DOI":"10.3174\/ajnr.A7921","article-title":"MR imaging of carotid artery atherosclerosis: Updated evidence on high-risk plaque features and emerging trends","volume":"44","author":"Benson","year":"2023","journal-title":"AJNR Am. J. Neuroradiol."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"1081","DOI":"10.1016\/j.jacc.2013.06.015","article-title":"Meta-analysis and systematic review of the predictive value of carotid plaque hemorrhage on cerebrovascular events by magnetic resonance imaging","volume":"62","author":"Saam","year":"2013","journal-title":"J. Am. Coll. Cardiol."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"774","DOI":"10.1016\/j.jvs.2013.09.028","article-title":"Intravascular ultrasound as a clinical adjunct for carotid plaque characterization","volume":"59","author":"Hitchner","year":"2014","journal-title":"J. Vasc. Surg."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"1494","DOI":"10.3174\/ajnr.A3016","article-title":"Intravascular frequency-domain optical coherence tomography assessment of atherosclerosis and stent-vessel interactions in human carotid arteries","volume":"33","author":"Jones","year":"2012","journal-title":"AJNR Am. J. Neuroradiol."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1016\/j.ejvs.2006.09.019","article-title":"Does free cell area influence the outcome in carotid artery stenting?","volume":"33","author":"Bosiers","year":"2007","journal-title":"Eur. J. Vasc. Endovasc. Surg."},{"key":"ref_29","first-page":"102429","article-title":"Carotid antiembolic (\u201cmesh\u201d) stents: Not created equal","volume":"3","author":"Musialek","year":"2024","journal-title":"J. Soc. Cardiovasc. Angiogr. Interv."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"1347","DOI":"10.4244\/EIJ-D-16-00866","article-title":"Optical coherence tomography assessment of new-generation mesh-covered stents after carotid stenting","volume":"13","author":"Umemoto","year":"2017","journal-title":"EuroIntervention"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"1229","DOI":"10.1016\/j.jcin.2015.04.016","article-title":"A prospective, multicenter study of a novel mesh-covered carotid stent: The CGuard CARENET trial (Carotid Embolic Protection Using MicroNet)","volume":"8","author":"Schofer","year":"2015","journal-title":"JACC Cardiovasc. Interv."},{"key":"ref_32","first-page":"149","article-title":"Highly-calcific carotid lesions endovascular management in symptomatic and increased-stroke-risk asymptomatic patients using the CGuard\u2122 dual-layer carotid stent system: Analysis from the PARADIGM study","volume":"94","author":"Mazurek","year":"2019","journal-title":"Catheter. Cardiovasc. Interv."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"1917","DOI":"10.1016\/j.jcin.2021.05.045","article-title":"1-Year results from a prospective experience on CAS using the CGuard stent system: The IRONGUARD 2 study","volume":"14","author":"Sirignano","year":"2021","journal-title":"JACC Cardiovasc. Interv."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"2377","DOI":"10.1016\/j.jcin.2021.08.005","article-title":"Randomized controlled trial of conventional versus MicroNet-covered stent in carotid artery revascularization","volume":"14","author":"Karpenko","year":"2021","journal-title":"JACC Cardiovasc. Interv."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"3087","DOI":"10.1016\/j.jcin.2025.09.027","article-title":"Safety and efficacy of a novel micro-net carotid stent system: Results of the C-GUARDIANS trial","volume":"18","author":"Metzger","year":"2025","journal-title":"JACC Cardiovasc. Interv."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"e671","DOI":"10.4244\/EIJY16M05_04","article-title":"The CLEAR-ROAD study: Evaluation of a new dual layer micromesh stent system for the carotid artery","volume":"12","author":"Bosiers","year":"2016","journal-title":"EuroIntervention"},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"1147","DOI":"10.4244\/EIJ-D-18-00513","article-title":"Carotid artery stenting with a new-generation double-mesh stent in three high-volume Italian centres: 12-month follow-up results","volume":"14","author":"Nerla","year":"2018","journal-title":"EuroIntervention"},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"403","DOI":"10.1016\/j.jcin.2019.09.007","article-title":"Carotid Wallstent versus Roadsaver stent and distal versus proximal protection on cerebral microembolization during carotid artery stenting","volume":"13","author":"Montorsi","year":"2020","journal-title":"JACC Cardiovasc. Interv."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"277","DOI":"10.1007\/s00270-021-03051-5","article-title":"Real-world study of a dual-layer micromesh stent in elective treatment of symptomatic and asymptomatic carotid artery stenosis (ROADSAVER)","volume":"45","author":"Kedev","year":"2022","journal-title":"Cardiovasc. Interv. Radiol."},{"key":"ref_40","doi-asserted-by":"crossref","unstructured":"Fujii, T., Maehara, S., Fukui, Y., Maruyama, K., Takigawa, K., Tashiro, N., Matsukawa, H., Hashiguchi, Y., Yasumoto, M., and Yasaka, M. (2025). Carotid artery stenting using CASPER has a lower incidence of ischemic complications compared to Carotid WALLSTENT, but there is no significant difference in postoperative restenosis. Interv. Neuroradiol.","DOI":"10.1177\/15910199251347774"},{"key":"ref_41","first-page":"121","article-title":"Evaluation of a novel mesh-covered stent for treatment of carotid stenosis in patients at high risk for endarterectomy: 1-year results of the SCAFFOLD trial","volume":"96","author":"Gray","year":"2020","journal-title":"Catheter. Cardiovasc. Interv."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"1709","DOI":"10.1016\/j.jcin.2020.03.048","article-title":"Use of dual-layered stents for carotid artery angioplasty: 1-year results of a patient-based meta-analysis","volume":"13","author":"Stabile","year":"2020","journal-title":"JACC Cardiovasc. Interv."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"339","DOI":"10.1177\/15266028221126940","article-title":"Carotid artery stenting with double-layer stent: A systematic review and meta-analysis","volume":"31","author":"Pini","year":"2024","journal-title":"J. Endovasc. Ther."},{"key":"ref_44","doi-asserted-by":"crossref","unstructured":"Mazurek, A., Malinowski, K., Rosenfield, K., Capoccia, L., Speziale, F., de Donato, G., Setacci, C., Wissgott, C., Sirignano, P., and Tekieli, L. (2022). Clinical outcomes of second- versus first-generation carotid stents: A systematic review and meta-analysis. J. Clin. Med., 11.","DOI":"10.3390\/jcm11164819"},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"213","DOI":"10.23736\/S0021-9509.24.13033-9","article-title":"Dual-layered micromesh stent technology for embolic prevention in carotid revascularization: Technical experience and clinical outcomes from a high-volume interventional radiology center","volume":"65","author":"Stefanini","year":"2024","journal-title":"J. Cardiovasc. Surg."},{"key":"ref_46","doi-asserted-by":"crossref","unstructured":"Mikelis, K., Kurminas, M., Lengvenis, G., Jan\u010diauskas, R., Misonis, N., Budrys, P., \u0160erpytis, R., and Ber\u016bk\u0161tis, A. (2025). Use of double-layer carotid stents is associated with improved patient survival and lower neurological complications: A single-center retrospective observational study. J. Clin. Med., 14.","DOI":"10.3390\/jcm14030888"},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"2534","DOI":"10.1161\/STROKEAHA.123.043117","article-title":"Impact of carotid stent design on embolic filter debris load during carotid artery stenting","volume":"54","author":"Squizzato","year":"2023","journal-title":"Stroke"},{"key":"ref_48","first-page":"e001156","article-title":"Transradial access versus transfemoral approach for carotid artery stenting: A systematic review and meta-analysis","volume":"4","author":"Guerrero","year":"2023","journal-title":"Stroke Vasc. Interv. Neurol."},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"447","DOI":"10.1177\/17085381221140616","article-title":"Embolic protection devices for carotid artery stenting: A network meta-analysis","volume":"32","author":"Giannopoulos","year":"2024","journal-title":"Vascular"},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"616","DOI":"10.1016\/j.jvs.2015.03.069","article-title":"Poststent ballooning is associated with increased periprocedural stroke and death rate in carotid artery stenting","volume":"62","author":"Obeid","year":"2015","journal-title":"J. Vasc. Surg."},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"384","DOI":"10.1016\/j.neurad.2019.03.006","article-title":"Efficacy of post-dilatation during carotid artery stenting for unstable plaque using closed-cell design stent evaluated by optical coherence tomography","volume":"46","author":"Harada","year":"2019","journal-title":"J. Neuroradiol."},{"key":"ref_52","first-page":"172","article-title":"A multi-center study of the MicroNET-covered stent in consecutive patients with acute carotid-related stroke: SAFEGUARD-STROKE","volume":"20","author":"Tekieli","year":"2024","journal-title":"Adv. Interv. Cardiol."},{"key":"ref_53","doi-asserted-by":"crossref","first-page":"219","DOI":"10.1080\/14779072.2020.1756777","article-title":"Clinical considerations and recommendations for OCT-guided carotid artery stenting","volume":"18","author":"Pasqui","year":"2020","journal-title":"Expert Rev. Cardiovasc. Ther."},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"756","DOI":"10.1161\/01.CIR.0000138103.91187.E3","article-title":"Carotid plaque echolucency increases the risk of stroke in carotid stenting: The Imaging in Carotid Angioplasty and Risk of Stroke (ICAROS) study","volume":"110","author":"Biasi","year":"2004","journal-title":"Circulation"},{"key":"ref_55","doi-asserted-by":"crossref","unstructured":"Gargiulo, G., Sannino, A., Stabile, E., Perrino, C., Trimarco, B., and Esposito, G. (2015). New cerebral lesions at magnetic resonance imaging after carotid artery stenting versus endarterectomy: An updated meta-analysis. PLoS ONE, 10.","DOI":"10.1371\/journal.pone.0129209"}],"container-title":["Medicina"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1648-9144\/62\/7\/1235\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,26]],"date-time":"2026-06-26T10:38:19Z","timestamp":1782470299000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1648-9144\/62\/7\/1235"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,26]]},"references-count":55,"journal-issue":{"issue":"7","published-online":{"date-parts":[[2026,7]]}},"alternative-id":["medicina62071235"],"URL":"https:\/\/doi.org\/10.3390\/medicina62071235","relation":{},"ISSN":["1648-9144"],"issn-type":[{"value":"1648-9144","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,6,26]]}}}