{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,28]],"date-time":"2026-09-28T16:25:35Z","timestamp":1790612735173,"version":"4.1.0"},"reference-count":20,"publisher":"MDPI AG","issue":"8","license":[{"start":{"date-parts":[[2020,8,14]],"date-time":"2020-08-14T00:00:00Z","timestamp":1597363200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100003654","name":"Korea Environmental Industry and Technology Institute","doi-asserted-by":"publisher","award":["2016001970001"],"award-info":[{"award-number":["2016001970001"]}],"id":[{"id":"10.13039\/501100003654","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Membranes"],"abstract":"<jats:p>A large quantity of volatile organic compounds (VOCs) can be released into water environments from oil spills and chemical exposure accidents. A recently developed solid ceramic dosimeter (SCD) could be used for long-term measuring of low VOCs concentrations in water. However, calibration and field testing of these SCDs have thus been far insufficient to apply for VOCs monitoring in a water environment in a chemical industrial area. We conducted laboratory calibration experiments and stability tests of the SCD. The mass accumulation of 14 target VOCs from 2 to 100 \u03bcg\/L was increased linearly with time in the sampler. The absorption rate of the VOCs was related to Henry\u2019s law constant. The average diffusion coefficient of the 14 VOCs in the SCD wall was 1.02 \u00d7 10\u22129 m2\/s. The SCD was utilized in a petrochemical plant complex in South Korea with an industrial wastewater reservoir. After a total of 7 days of deployment, chloroform, ethylbenzene, and toluene were detected by both passive sampling and grab sampling at the same VOC concentrations.<\/jats:p>","DOI":"10.3390\/membranes10080186","type":"journal-article","created":{"date-parts":[[2020,8,14]],"date-time":"2020-08-14T13:00:18Z","timestamp":1597410018000},"page":"186","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Application of a Solid Ceramic Membrane for Monitoring Volatile Organic Compounds in Industrial Wastewater"],"prefix":"10.3390","volume":"10","author":[{"given":"Injeong","family":"Kim","sequence":"first","affiliation":[{"name":"Jeonbuk Department of Inhalation Research, Korea Institute of Toxicology, Jeongeup 56212, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jinseul","family":"Yoon","sequence":"additional","affiliation":[{"name":"School of Earth Sciences and Environmental Engineering, Gwangju Institute of Science and Technology, 123 Cheomdangwagi-ro, Buk-gu, Gwangju 61005, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sang","family":"Kim","sequence":"additional","affiliation":[{"name":"School of Earth Sciences and Environmental Engineering, Gwangju Institute of Science and Technology, 123 Cheomdangwagi-ro, Buk-gu, Gwangju 61005, Korea"},{"name":"Center for Chemicals Risk Assessment, Gwangju Institute of Science and Technology, 123 Cheomdangwagi-ro, Buk-gu, Gwangju 61005, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2020,8,14]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"361","DOI":"10.1016\/j.jlp.2009.01.006","article-title":"Case studies of chemical incidents and emergency information service in Korea","volume":"22","author":"Chung","year":"2009","journal-title":"J. Loss. Prev. Process Ind."},{"key":"ref_2","doi-asserted-by":"crossref","unstructured":"Bloemen, H.J., and Burn, J. (1993). Chemistry and Analysis of Volatile Organic Compounds in the Environment, Springer Science & Business Media. [1st ed.].","DOI":"10.1007\/978-94-011-2152-1"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1080\/10643380091184183","article-title":"Transport, behavior, and fate of volatile organic compounds in streams","volume":"30","author":"Rathbun","year":"2000","journal-title":"Crit. Rev. Environ. Sci. Technol."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"180","DOI":"10.1016\/j.chemosphere.2016.12.153","article-title":"Human health and ecological assessment programs for Hebei Spirit oil spill accident of 2007: Status, lessons, and future challenges","volume":"173","author":"Jung","year":"2017","journal-title":"Chemosphere"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"273","DOI":"10.1007\/s00216-009-3244-4","article-title":"Passive sampling as a tool for obtaining reliable analytical information in environmental quality monitoring","volume":"396","author":"Urbanowicz","year":"2010","journal-title":"Anal. Bioanal. Chem."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1016\/j.aca.2007.09.013","article-title":"Advances in passive sampling in environmental studies","volume":"602","author":"Urbanowicz","year":"2007","journal-title":"Anal. Chim. Acta"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"6868","DOI":"10.1021\/es070807s","article-title":"Passive sampler for combined chemical and toxicological long-term monitoring of groundwater: The ceramic toximeter","volume":"41","author":"Bopp","year":"2007","journal-title":"Environ. Sci. Technol."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"137","DOI":"10.1016\/j.chroma.2004.12.049","article-title":"Time-integrated monitoring of polycyclic aromatic hydrocarbons (PAHs) in groundwater using the Ceramic Dosimeter passive sampling device","volume":"1072","author":"Bopp","year":"2005","journal-title":"J. Chromatogr. A"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1016\/j.envpol.2012.08.014","article-title":"Assessment of flame retardants in river water using a ceramic dosimeter passive sampler","volume":"172","author":"Cristale","year":"2013","journal-title":"Environ. Pollut."},{"key":"ref_10","unstructured":"Huckins, J.N., Petty, J.D., and Booij, K. (2006). Introduction to Passive Sampling. Monitors of Organic Chemicals in the Environment: Semipermeable Membrane Devices, Springer Science & Business Media. [1st ed.]."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"12557","DOI":"10.1021\/acs.est.7b03678","article-title":"Development of Solid Ceramic Dosimeters for the Time-Integrative Passive Sampling of Volatile Organic Compounds in Waters","volume":"51","author":"Bonifacio","year":"2017","journal-title":"Environ. Sci. Technol."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"234","DOI":"10.1016\/j.chroma.2007.07.070","article-title":"Passive sampling in environmental analysis","volume":"1184","author":"Seethapathy","year":"2008","journal-title":"J. Chromatogr. A"},{"key":"ref_13","first-page":"279","article-title":"Use of ceramic dosimeters in water monitoring","volume":"48","author":"Schirmer","year":"2007","journal-title":"Compr. Anal. Chem."},{"key":"ref_14","doi-asserted-by":"crossref","unstructured":"Zogorski, J.S., Carter, J.M., Ivahnenko, T., Lapham, W.W., Moran, M.J., Rowe, B.L., Squillace, P.J., and Toccalino, P.L. (2006). The Quality of Our Nation\u2019s Waters\u2014Volatile Organic Compounds in the Nation\u2019s Ground Water and Drinking-Water Supply Wells.","DOI":"10.3133\/cir1292"},{"key":"ref_15","unstructured":"(2020, January 12). OEHHA Home Page, Available online:https:\/\/oehha.ca.gov\/proposition-65\/proposition-65-list."},{"key":"ref_16","unstructured":"(2020, January 12). IARC Monographs on the Identification of Carcinogenic Hazards to Humans Home Page. Available online: https:\/\/monographs.iarc.fr\/list-of-classifications\/."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"4399","DOI":"10.5194\/acp-15-4399-2015","article-title":"Compilation of Henry\u2019s law constants (version 4.0) for water as solvent","volume":"15","author":"Sander","year":"2015","journal-title":"Atmos. Chem. Phys."},{"key":"ref_18","unstructured":"United States Environmental Protection Agency (USEPA) (2002). Method 5035A: Closed-System Purge-and-Trap and Extraction for Volatile Organics in Soil and Waste Samples. Draft Revision 1."},{"key":"ref_19","unstructured":"United States Environmental Protection Agency (USEPA) (2016). Definition and Procedure for the Determination of the Method Detection Limit, Revision 2."},{"key":"ref_20","unstructured":"European Commission (2017). Guidance Document on Analytical Quality Control and Method Validation Procedures for Pesticide Residues and Analysis in Food and Feed, Revision 0, European Commission."}],"container-title":["Membranes"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2077-0375\/10\/8\/186\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T10:01:06Z","timestamp":1760176866000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2077-0375\/10\/8\/186"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,8,14]]},"references-count":20,"journal-issue":{"issue":"8","published-online":{"date-parts":[[2020,8]]}},"alternative-id":["membranes10080186"],"URL":"https:\/\/doi.org\/10.3390\/membranes10080186","relation":{},"ISSN":["2077-0375"],"issn-type":[{"value":"2077-0375","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,8,14]]}}}