{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,4]],"date-time":"2026-04-04T00:18:28Z","timestamp":1775261908865,"version":"3.50.1"},"reference-count":81,"publisher":"MDPI AG","issue":"3","license":[{"start":{"date-parts":[[2020,2,25]],"date-time":"2020-02-25T00:00:00Z","timestamp":1582588800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Micromachines"],"abstract":"<jats:p>Fast point-of-use detection of, for example, early-stage zoonoses, e.g., Q-fever, bovine tuberculosis, or the Covid-19 coronavirus, is beneficial for both humans and animal husbandry as it can save lives and livestock. The latter prevents farmers from going bankrupt after a zoonoses outbreak. This paper describes the development of a fabrication process and the proof-of-principle of a disposable DNA amplification chip with an integrated heater. Based on the analysis of the milling process, metal adhesion studies, and COMSOL MultiPhysics heat transfer simulations, the first batch of chips has been fabricated and successful multiple displacement amplification reactions are performed inside these chips. This research is the first step towards the development of an early-stage zoonoses detection device. Tests with real zoonoses and DNA specific amplification reactions still need to be done.<\/jats:p>","DOI":"10.3390\/mi11030238","type":"journal-article","created":{"date-parts":[[2020,2,25]],"date-time":"2020-02-25T08:12:22Z","timestamp":1582618342000},"page":"238","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":14,"title":["Disposable DNA Amplification Chips with Integrated Low-Cost Heaters \u2020"],"prefix":"10.3390","volume":"11","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-6044-5891","authenticated-orcid":false,"given":"Henk-Willem","family":"Veltkamp","sequence":"first","affiliation":[{"name":"Department of Integrated Devices and Systems, University of Twente, P.O. Box 217, 7500 AE Enschede, The Netherlands"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8095-7459","authenticated-orcid":false,"given":"Fernanda","family":"Akegawa Monteiro","sequence":"additional","affiliation":[{"name":"Department of Integrated Devices and Systems, University of Twente, P.O. Box 217, 7500 AE Enschede, The Netherlands"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Remco","family":"Sanders","sequence":"additional","affiliation":[{"name":"Department of Integrated Devices and Systems, University of Twente, P.O. Box 217, 7500 AE Enschede, The Netherlands"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5571-739X","authenticated-orcid":false,"given":"Remco","family":"Wiegerink","sequence":"additional","affiliation":[{"name":"Department of Integrated Devices and Systems, University of Twente, P.O. Box 217, 7500 AE Enschede, The Netherlands"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Joost","family":"L\u00f6tters","sequence":"additional","affiliation":[{"name":"Department of Integrated Devices and Systems, University of Twente, P.O. Box 217, 7500 AE Enschede, The Netherlands"},{"name":"Bronkhorst High-Tech BV, Nijverheidsstraat 1A, 7261 AK Ruurlo, The Netherlands"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2020,2,25]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"166","DOI":"10.3389\/fvets.2018.00166","article-title":"Zoonotic diseases and phytochemical medicines for microbial infection in veterinary science: Current state and future perspective","volume":"5","author":"Shin","year":"2018","journal-title":"Front. Vet. Sci."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"144","DOI":"10.3389\/fpubh.2014.00144","article-title":"Review: The important bacterial zoonoses in \u201cOne Health\u201d concept","volume":"2","author":"Cantas","year":"2014","journal-title":"Front. Public Health"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"S27","DOI":"10.1016\/j.jcpa.2015.03.004","article-title":"Bacterial zoonoses transmitted by household pets: State-of-the-art and future perspectives for targeted research and policy actions","volume":"155","author":"Damborg","year":"2016","journal-title":"J. Comp. Pathol."},{"key":"ref_4","doi-asserted-by":"crossref","unstructured":"Helmy, Y.A., El-Adawy, H., and Abdelwhab, E.M. (2017). A comprehensive review of common bacterial, parasitic and viral zoonoses at the human-anmial interface in Egypt. Pathogens, 6.","DOI":"10.3390\/pathogens6030033"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"646","DOI":"10.1111\/j.1469-0691.2012.03850.x","article-title":"Extended-spectrum \u03b2-lactamase-producing and AmpC-producing Escherichia coli from livestock and companion animals, and their putative impact on public health: A global perspective","volume":"18","author":"Ewers","year":"2012","journal-title":"Clin. Microbiol. Infect."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"233","DOI":"10.1016\/j.jcv.2003.08.004","article-title":"Early diagnosis of SARS coronavirus infection by real time RT-PCR","volume":"28","author":"Poon","year":"2003","journal-title":"J. Clin. Virol."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"329","DOI":"10.1007\/978-94-007-4315-1_17","article-title":"Epidemic Q fever in humans in the Netherlands","volume":"984","author":"Morroy","year":"2012","journal-title":"Adv. Exp. Med. Biol."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1350","DOI":"10.1126\/science.2999980","article-title":"Enzymatic amplification of beta-globin genomic sequences and restriction site analysis for diagnosis of sickle cell anemia","volume":"230","author":"Saiki","year":"1985","journal-title":"Science"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"795","DOI":"10.1038\/sj.embor.7400200","article-title":"Helicase-dependent isothermal DNA amplification","volume":"5","author":"Vincent","year":"2004","journal-title":"EMBO Rep."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"15.11.1","DOI":"10.1002\/0471142727.mb1511s104","article-title":"Helicase-dependent amplification of nucleic acids","volume":"104","author":"Cao","year":"2013","journal-title":"Curr. Protoc. Mol. Biol."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"e61","DOI":"10.1093\/nar\/28.12.e63","article-title":"Loop-mediated isothermal amplification of DNA","volume":"28","author":"Notomi","year":"2000","journal-title":"Nucleic Acids Res."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"8769","DOI":"10.1039\/c3cs60144g","article-title":"Portable nucleic acid thermocyclers","volume":"42","author":"Almassian","year":"2013","journal-title":"Chem. Soc. Rev."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"44","DOI":"10.1016\/j.trac.2019.01.015","article-title":"LAMP-on-a-chip: Revising microfluidic platforms for loop-mediated DNA amplification","volume":"113","author":"Zhang","year":"2019","journal-title":"TrAC Trends Anal. Chem."},{"key":"ref_14","doi-asserted-by":"crossref","unstructured":"Bruijns, B.B., van Asten, A.C., Tiggelaar, R.M., and Gardeniers, J. (2016). Microfluidic Devices for Forensic DNA Analysis: A Review. Biosensors, 6.","DOI":"10.3390\/bios6030041"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1016\/j.aca.2009.02.038","article-title":"Microfluidic DNA amplification\u2014A review","volume":"638","author":"Zhang","year":"2009","journal-title":"Anal. Chim. Acta"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"1611","DOI":"10.1007\/s00604-013-1140-2","article-title":"Extraction, amplification and detection of DNA in microfluidic chip-based assays","volume":"181","author":"Wu","year":"2013","journal-title":"Microchim. Acta"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"1420","DOI":"10.1039\/c0lc00666a","article-title":"Miniaturized isothermal nucleic acid amplification, a review","volume":"11","author":"Asiello","year":"2011","journal-title":"Lab Chip"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"784","DOI":"10.1111\/j.1556-4029.2007.00468.x","article-title":"Forensic DNA analysis on microfluidic devices: A review","volume":"52","author":"Horsman","year":"2007","journal-title":"J. Forensic Sci."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1016\/S1389-0352(01)00033-2","article-title":"Flow-through polymerase chain reactions in chip thermocyclers","volume":"82","year":"2001","journal-title":"Rev. Mol. Biotech."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.aca.2012.04.031","article-title":"Miniaturized nucleic acid amplification systems for rapid and point-of-care diagnostics: A review","volume":"733","author":"Ahmad","year":"2012","journal-title":"Anal. Chim. Acta"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"2469","DOI":"10.1039\/c2lc40100b","article-title":"Isothermal nucleic acid amplification technologies for point-of-care diagnostics: A critical review","volume":"12","author":"Craw","year":"2012","journal-title":"Lab Chip"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"2053","DOI":"10.1007\/s00216-011-4947-x","article-title":"Three-dimensional on-chip continuous-flow polymerase chain reaction employing a single heater","volume":"400","author":"Wu","year":"2011","journal-title":"Anal. Bioanal. Chem."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"2","DOI":"10.5213\/inj.2013.17.1.2","article-title":"Recent progress in lab-on-a-chip technology and its potential application to clinical diagnoses","volume":"17","author":"Lee","year":"2013","journal-title":"Int. Neurol. J."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"264101","DOI":"10.1063\/1.3530452","article-title":"Exploring the limits of ultrafast polymerase chain reaction using liquid for thermal heat exchange: A proof of principle","volume":"97","author":"Maltezos","year":"2010","journal-title":"Appl. Phys. Lett."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"464","DOI":"10.1039\/C1LC20693A","article-title":"Highly-integrated lab-on-chip system for point-of-care multiparameter analysis","volume":"12","author":"Schumacher","year":"2012","journal-title":"Lab Chip"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"589","DOI":"10.1109\/TDMR.2014.2311801","article-title":"Thechnological journey towards reliable microheater development for MEMS gas sensors: A review","volume":"14","author":"Bhattacharyya","year":"2014","journal-title":"IEEE Trans. Device Mater. Reliab."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"1215","DOI":"10.1109\/TIM.2014.2364697","article-title":"Thermal modeling and characterization of a thin-film heater on glass substrate for lab-on-chip applications","volume":"64","author":"Scorzoni","year":"2015","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"031006","DOI":"10.1117\/1.3455371","article-title":"Comparison of different metal film thicknesses of cyclic olefin copolymer-substrate polymerase chain-reaction chips with single-side and double-side heaters","volume":"9","author":"Chung","year":"2010","journal-title":"J. Micro\/Nanolithogr. MEMS MOEMS"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"025025","DOI":"10.1088\/0960-1317\/21\/2\/025025","article-title":"Experimental study of heat-treated thin film Ti\/Pt heater and temperature sensor properties on a Si microfluidic platform","volume":"21","author":"Resnik","year":"2011","journal-title":"J. Micromech. Microeng."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"470","DOI":"10.1016\/j.snb.2014.04.007","article-title":"All-plastic, low-power, disposable, continuous-flow PCR chip with integrated microheaters for rapid DNA amplification","volume":"199","author":"Moschou","year":"2014","journal-title":"Sens. Actuators B Chem."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"154105","DOI":"10.1063\/1.2089174","article-title":"Thermal management in microfluidics using micro-Peltier junctions","volume":"87","author":"Maltezos","year":"2005","journal-title":"Appl. Phys. Lett."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"70","DOI":"10.1007\/s00502-009-0605-9","article-title":"Fast thermo-pneumatic actuation of a thin PDMS membrane using a micro Peltier-element for microfluidic applications","volume":"126","author":"Lederer","year":"2009","journal-title":"Elektrotech. Inf."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"401","DOI":"10.1039\/b313547k","article-title":"Bulk-micromachined submicroliter-volume PCR chip with very rapid thermal response and low power consumption","volume":"4","author":"Lee","year":"2004","journal-title":"Lab Chip"},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"359","DOI":"10.1007\/s10544-008-9242-z","article-title":"A micro circulating PCR chip using a suction-type membrane for fluidic transport","volume":"11","author":"Chien","year":"2009","journal-title":"Biomed. Microdevices"},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"72","DOI":"10.1016\/j.ijthermalsci.2012.12.003","article-title":"Thermal modeling and design analysis of a continuous flow microfluidic chip","volume":"67","author":"Kumar","year":"2013","journal-title":"Int. J. Therm. Sci."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1016\/j.snb.2019.04.144","article-title":"On-chip real-time monitoring of multiple displacement amplification of DNA","volume":"293","author":"Bruijns","year":"2019","journal-title":"Sens. Actuators B Chem."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"085014","DOI":"10.1088\/1361-6439\/aabd2c","article-title":"A comprehensive methodology for design and development of an integrated microheater for on-chip DNA amplification","volume":"28","author":"Barman","year":"2018","journal-title":"J. Micromech. Microeng."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"3002","DOI":"10.1021\/ac1000652","article-title":"Loop-mediated isothermal amplification integrated on microfluidic chips for point-of-care quantitative detection of pathogens","volume":"82","author":"Fang","year":"2010","journal-title":"Anal. Chem."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1146\/annurev.matsci.28.1.153","article-title":"Soft lithography","volume":"28","author":"Xia","year":"1998","journal-title":"Annu. Rev. Mater. Sci."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"3858","DOI":"10.1021\/acs.analchem.7b00136","article-title":"Comparing microfluidic performance of three-dimensional (3D) printing platforms","volume":"89","author":"Macdonald","year":"2017","journal-title":"Anal. Chem."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"2364","DOI":"10.1039\/C5LC00234F","article-title":"Micromilling: A method for ultra-rapid prototyping of plastic microfulidic devices","volume":"15","author":"Guckenberger","year":"2015","journal-title":"Lab Chip"},{"key":"ref_42","unstructured":"Topas Advanced Polymers (2019, June 18). Cyclic Olefin Copolymer (COC). Available online: https:\/\/topas.com\/sites\/default\/files\/files\/TOPAS_Brochure_E_2014_06(1).pdf."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"353","DOI":"10.1007\/s10544-009-9391-8","article-title":"An integrated disposable device for DNA extraction and helicase dependent amplification","volume":"12","author":"Mahalanabis","year":"2010","journal-title":"Biomed. Microdevices"},{"key":"ref_44","unstructured":"Bruijns, B.B. (2019). Microfluidic Devices for Presumptive Forensic Tests. [Ph.D. Thesis, University of Twente]."},{"key":"ref_45","doi-asserted-by":"crossref","unstructured":"Bruijns, B.B., Veciana, A., Tiggelaar, R.M., and Gardeniers, J.G.E. (2019). Cyclic olefin copolymer microfluidic devices for forensic applications. Biosensors, 9.","DOI":"10.3390\/bios9030085"},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"689","DOI":"10.1002\/sia.1737","article-title":"Surface modification of cycloolefinic copolymers for optimization of the adhesion to metals","volume":"36","author":"Nikolova","year":"2004","journal-title":"Surf. Interface Anal."},{"key":"ref_47","unstructured":"Anderson, H.S. (1998). Organic Pre-Etch Treatment for Metal Plating of Cyclic Olefin Polymers. (USH1807H), U.S. Patent, Available online: https:\/\/patents.google.com\/patent\/USH1807H\/en."},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"3037","DOI":"10.1039\/C4LC00423J","article-title":"Cyclic olefin copolymer plasma millireactors","volume":"14","author":"Schelcher","year":"2014","journal-title":"Lab Chip"},{"key":"ref_49","first-page":"802902","article-title":"Instrument-free nucleic acid amplification assays for global health settings","volume":"8029","author":"LaBarre","year":"2011","journal-title":"Proc. SPIE Int. Soc. Opt. Eng."},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"603","DOI":"10.1002\/humu.20341","article-title":"Multiple displacement amplification to create a long-lasting source of DNA for genetic studies","volume":"27","author":"Lovmar","year":"2006","journal-title":"Hum. Mutat."},{"key":"ref_51","first-page":"1","article-title":"Whole genome amplification in preimplantation genetic diagnosis","volume":"12","author":"Zheng","year":"2011","journal-title":"J. Zheijang Univ. Sci. B Biomed. Biotech."},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"407","DOI":"10.1111\/1574-6976.12015","article-title":"The future is now: Single-cell genomics of bacteria and archaea","volume":"37","author":"Blainey","year":"2013","journal-title":"FEMS Microbiol. Rev."},{"key":"ref_53","doi-asserted-by":"crossref","first-page":"466","DOI":"10.1002\/biot.200600011","article-title":"Sequence quality is maintained after multiple displacement amplification of non-invasively obtained macaque semen DNA","volume":"1","author":"Ferrando","year":"2006","journal-title":"Biotech. J."},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"33","DOI":"10.3390\/diagnostics3010033","article-title":"A review of heating and temperature control in microfluidic systems: Techniques and applications","volume":"3","author":"Miralles","year":"2013","journal-title":"Diagnostics"},{"key":"ref_55","doi-asserted-by":"crossref","first-page":"127","DOI":"10.1007\/s10404-017-1961-0","article-title":"A versatile technology platform for microfluidic handling systems, part I: Fabrication and functionalization","volume":"21","author":"Groenesteijn","year":"2017","journal-title":"Microfluid. Nanofluid."},{"key":"ref_56","unstructured":"COMSOL MultiPhysics (2020, January 15). Modeling Natural and Forced Convection in COMSOL Multiphysics. Available online: https:\/\/www.comsol.com\/blogs\/modeling-natural-and-forced-convection-in-comsol-multiphysics\/."},{"key":"ref_57","doi-asserted-by":"crossref","first-page":"691","DOI":"10.1088\/0305-4608\/3\/4\/010","article-title":"Electromigration in thin gold films","volume":"3","author":"Klein","year":"1973","journal-title":"J. Phys. Metal Phys."},{"key":"ref_58","doi-asserted-by":"crossref","first-page":"114709","DOI":"10.1063\/1.4901937","article-title":"Power regulation and electromigration in platinum microwires","volume":"85","author":"Vasile","year":"2014","journal-title":"Rev. Sci. Instrum."},{"key":"ref_59","doi-asserted-by":"crossref","first-page":"065016","DOI":"10.1088\/0960-1317\/20\/6\/065016","article-title":"Reduction of surface roughness for optical quality microfluidic devices in PMMA and COC","volume":"20","author":"Ogilvie","year":"2010","journal-title":"J. Micromech. Microeng."},{"key":"ref_60","doi-asserted-by":"crossref","first-page":"1381","DOI":"10.1063\/1.1138605","article-title":"Improved adhesion of thin conformal organic films to metal surfaces","volume":"57","author":"Silvera","year":"1986","journal-title":"Rev. Sci. Instrum."},{"key":"ref_61","first-page":"72256","article-title":"Tough bonding of metallic layers to hydrocarbon surfaces by depositing Ag films","volume":"76","author":"Chen","year":"2016","journal-title":"RCS Adva."},{"key":"ref_62","unstructured":"(2019, November 11). Gwyddion. Available online: http:\/\/gwyddion.net\/."},{"key":"ref_63","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/1472-6750-7-76","article-title":"Characterization of EvaGreen and the implication of its physicochemical properties for qPCR applications","volume":"7","author":"Mao","year":"2007","journal-title":"BMC Biotech."},{"key":"ref_64","doi-asserted-by":"crossref","first-page":"313","DOI":"10.1063\/1.1735158","article-title":"Temperature coefficients of resistance of metallic films in the temperature range 25 \u00b0C to 600 \u00b0C","volume":"30","author":"Belser","year":"1959","journal-title":"J. Appl. Phys."},{"key":"ref_65","doi-asserted-by":"crossref","first-page":"89","DOI":"10.1016\/0040-6090(74)90254-5","article-title":"Electrical and structural properties of thin gold films obtained by vacuum evaporation and sputtering","volume":"24","author":"Adamov","year":"1974","journal-title":"Thin Solid Films"},{"key":"ref_66","doi-asserted-by":"crossref","first-page":"1698","DOI":"10.1002\/app.22666","article-title":"Characterization of evaporated and sputtered thin Au layers on poly(ethylene terephtalate)","volume":"99","author":"Zehentner","year":"2006","journal-title":"J. Appl. Polym. Sci."},{"key":"ref_67","unstructured":"Fraden, J. (2004). Handbook of Modern Sensors: Physics, Designs, and Applications, Springer Inc.. [3rd ed.]."},{"key":"ref_68","unstructured":"Rumble, J.R. (2019). Thermal and Physical Properties of Pure Metals, in CRC Handbook of Chemistry and Physics, CRC Press\/Taylor & Francis. [100th ed.]."},{"key":"ref_69","doi-asserted-by":"crossref","first-page":"1027","DOI":"10.1007\/BF01729121","article-title":"Longitudinal and transverse strain sensitivity of gold film","volume":"6","author":"Rajanna","year":"1987","journal-title":"J. Mater. Sci. Lett."},{"key":"ref_70","doi-asserted-by":"crossref","first-page":"813","DOI":"10.1116\/1.578828","article-title":"Thin gold film strain gauges","volume":"12","author":"Li","year":"1994","journal-title":"J. Vac. Sci. Technol. A"},{"key":"ref_71","doi-asserted-by":"crossref","first-page":"248","DOI":"10.1039\/C6MH00027D","article-title":"Structural engineering of gold thin films with channel cracks for ultrasensitive strain sensing","volume":"3","author":"Yang","year":"2016","journal-title":"Mater. Horizon"},{"key":"ref_72","doi-asserted-by":"crossref","first-page":"1319","DOI":"10.1088\/0957-0233\/4\/12\/002","article-title":"Diapragm-type sputtered platinum thin film strain gauge pressure transducer","volume":"4","author":"Nayak","year":"1993","journal-title":"Meas. Sci. Technol."},{"key":"ref_73","doi-asserted-by":"crossref","unstructured":"Qu, Y.Q., Melamud, R., Chandorkar, S., Lee, H.K., and Kenny, T.W. (2010, January 24\u201328). Stress relaxation study of sputtered Platinum thin films at near room temperature using an ultrasensitive strain gauge. Proceedings of the IEEE 23rd International Conference on Micro Electro Mechanical Systems, Hong Kong, China.","DOI":"10.1109\/MEMSYS.2010.5442445"},{"key":"ref_74","doi-asserted-by":"crossref","first-page":"258","DOI":"10.1016\/j.promfg.2018.06.030","article-title":"Simultaneous measurement of strain and temperature with two resistive strain gauges made from different materials","volume":"24","author":"Dumstorff","year":"2018","journal-title":"Proced. Manuf."},{"key":"ref_75","doi-asserted-by":"crossref","first-page":"287","DOI":"10.1016\/S0257-8972(98)00718-X","article-title":"Better aluminium mirrors by integrating plasma pretreatment, sputtering, and plasma polymerization for large-scale car headlight production","volume":"111","author":"Adam","year":"1999","journal-title":"Surf. Coat. Technol."},{"key":"ref_76","doi-asserted-by":"crossref","first-page":"150","DOI":"10.1006\/bbrc.2001.5921","article-title":"Detection of loop-mediated isothermal amplification reation by turbidity derived from magnesium pyrophosphate formation","volume":"289","author":"Mori","year":"2001","journal-title":"Biochem. Biophys. Res. Commun."},{"key":"ref_77","first-page":"76","article-title":"Rapid cycle DNA amplification: Time and temperature optimization","volume":"10","author":"Wittwer","year":"1991","journal-title":"Biotechniques"},{"key":"ref_78","doi-asserted-by":"crossref","unstructured":"Islam, M.S., Aryasomayajula, A., and Selvaganapathy, P.R. (2017). A review on macroscale and microscale cell lysis methods. Micromachines, 8.","DOI":"10.3390\/mi8030083"},{"key":"ref_79","doi-asserted-by":"crossref","first-page":"3741","DOI":"10.1128\/aem.63.10.3741-3751.1997","article-title":"Inhibition and facilitation of nucleic acid amplification","volume":"63","author":"Wilson","year":"1997","journal-title":"Appl. Environ. Microbiol."},{"key":"ref_80","doi-asserted-by":"crossref","first-page":"5261","DOI":"10.1073\/pnas.082089499","article-title":"Comprehensive human genome amplification using multiple displacement amplification","volume":"99","author":"Dean","year":"2002","journal-title":"Proc. Natl. Acad. Sci. USA"},{"key":"ref_81","unstructured":"Engineering Toolbox (2019, August 06). Water\u2014Heat Capacity (Specific Heat). Available online: https:\/\/www.engineeringtoolbox.com\/specific-heat-capacity-water-d_660.html."}],"container-title":["Micromachines"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2072-666X\/11\/3\/238\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T09:01:29Z","timestamp":1760173289000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2072-666X\/11\/3\/238"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,2,25]]},"references-count":81,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2020,3]]}},"alternative-id":["mi11030238"],"URL":"https:\/\/doi.org\/10.3390\/mi11030238","relation":{},"ISSN":["2072-666X"],"issn-type":[{"value":"2072-666X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,2,25]]}}}