{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,28]],"date-time":"2026-09-28T18:35:03Z","timestamp":1790620503934,"version":"4.1.0"},"reference-count":25,"publisher":"MDPI AG","issue":"4","license":[{"start":{"date-parts":[[2020,4,13]],"date-time":"2020-04-13T00:00:00Z","timestamp":1586736000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100000268","name":"Biotechnology and Biological Sciences Research Council","doi-asserted-by":"publisher","award":["BB\/R012415\/1"],"award-info":[{"award-number":["BB\/R012415\/1"]}],"id":[{"id":"10.13039\/501100000268","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Micromachines"],"abstract":"<jats:p>Obstructions of the ureter lumen can originate from intrinsic or extrinsic factors, such as kidney stones, tumours, or strictures. These can affect the physiological flow of urine from the kidneys to the bladder, potentially causing infection, pain, and kidney failure. To overcome these complications, ureteral stents are often deployed clinically in order to temporarily re-establish urinary flow. Despite their clinical benefits, stents are prone to encrustation and biofilm formation that lead to reduced quality of life for patients; however, the mechanisms underlying the formation of crystalline biofilms in stents are not yet fully understood. In this study, we developed microfluidic-based devices replicating the urodynamic field within different configurations of an occluded and stented ureter. We employed computational fluid dynamic simulations to characterise the flow dynamic field within these models and investigated bacterial attachment (Pseudomonas fluorescens) by means of crystal violet staining and fluorescence microscopy. We identified the presence of hydrodynamic cavities in the vicinity of a ureteric occlusion, which were characterised by low levels of wall shear stress (WSS &lt; 40 mPa), and observed that initiation of bacterial attachment occurred in these specific regions of the stented ureter. Notably, the bacterial coverage area was directly proportional to the number of cavities present in the model. Fluorescence microscopy confirmed that the number density of bacteria was greater within cavities (3 bacteria\u00b7mm\u22122) when compared to side-holes of the stent (1 bacterium\u00b7mm\u22122) or its luminal surface (0.12 bacteria\u00b7mm\u22122). These findings informed the design of a novel technological solution against bacterial attachment, which reduces the extent of cavity flow and increases wall shear stress over the stent\u2019s surface.<\/jats:p>","DOI":"10.3390\/mi11040408","type":"journal-article","created":{"date-parts":[[2020,4,14]],"date-time":"2020-04-14T03:10:01Z","timestamp":1586833801000},"page":"408","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":33,"title":["A Microfluidic-Based Investigation of Bacterial Attachment in Ureteral Stents"],"prefix":"10.3390","volume":"11","author":[{"given":"Antonio","family":"De Grazia","sequence":"first","affiliation":[{"name":"Bioengineering Science Research Group, Faculty of Engineering and Physical Sciences, University of Southampton, Southampton SO17 1BJ, UK"},{"name":"Institute for Life Sciences (IfLS), University of Southampton, Southampton SO17 1BJ, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5383-1081","authenticated-orcid":false,"given":"Gareth","family":"LuTheryn","sequence":"additional","affiliation":[{"name":"Bioengineering Science Research Group, Faculty of Engineering and Physical Sciences, University of Southampton, Southampton SO17 1BJ, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alireza","family":"Meghdadi","sequence":"additional","affiliation":[{"name":"Bioengineering Science Research Group, Faculty of Engineering and Physical Sciences, University of Southampton, Southampton SO17 1BJ, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ali","family":"Mosayyebi","sequence":"additional","affiliation":[{"name":"Bioengineering Science Research Group, Faculty of Engineering and Physical Sciences, University of Southampton, Southampton SO17 1BJ, UK"},{"name":"Institute for Life Sciences (IfLS), University of Southampton, Southampton SO17 1BJ, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Erika","family":"Espinosa-Ortiz","sequence":"additional","affiliation":[{"name":"Center for Biofilm Engineering and Department of Chemical and Biological Engineering, Montana State University, Bozeman, MT 59717, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robin","family":"Gerlach","sequence":"additional","affiliation":[{"name":"Center for Biofilm Engineering and Department of Chemical and Biological Engineering, Montana State University, Bozeman, MT 59717, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dario","family":"Carugo","sequence":"additional","affiliation":[{"name":"Bioengineering Science Research Group, Faculty of Engineering and Physical Sciences, University of Southampton, Southampton SO17 1BJ, UK"},{"name":"Institute for Life Sciences (IfLS), University of Southampton, Southampton SO17 1BJ, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2020,4,13]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"1092","DOI":"10.1016\/j.juro.2014.10.123","article-title":"The use of internal stents in chronic ureteral obstruction","volume":"193","author":"Fiuk","year":"2015","journal-title":"J. Urol."},{"key":"ref_2","doi-asserted-by":"crossref","unstructured":"Kulkarni, R. (2017). Ureteric Stenting, Wiley Blackwell. [1st ed.].","DOI":"10.1002\/9781119085713"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"S436","DOI":"10.21037\/tau.2019.08.16","article-title":"Latest advancements in ureteral stent technology","volume":"8","author":"Somani","year":"2019","journal-title":"Transl. Urol."},{"key":"ref_4","first-page":"e147","article-title":"Risk factor analysis and management of ureteral double-j stent complications","volume":"12","author":"Ahallal","year":"2010","journal-title":"Rev. Urol."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1177\/1756287210370699","article-title":"Ureteral stents: New ideas, new designs","volume":"2","author":"Kyriazis","year":"2010","journal-title":"Adv. Urol."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"194","DOI":"10.1016\/j.ajur.2015.08.006","article-title":"Ureteral stent technology: Drug-eluting stents and stent coatings","volume":"2","author":"Yang","year":"2015","journal-title":"Asian J. Urol."},{"key":"ref_7","first-page":"270","article-title":"Engineering solutions to ureteral stents: Material, Coating and Design","volume":"70","author":"Mosayyebi","year":"2017","journal-title":"Cent. Eur. J. Urol."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1007\/PL00007074","article-title":"Advances in ureteral stent technology","volume":"18","author":"Denstedt","year":"2000","journal-title":"World J. Urol."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"178","DOI":"10.1089\/end.2011.0385","article-title":"Ureteral stent encrustation, incrustation, and coloring: Morbidity related to indwelling times","volume":"26","author":"Kawahara","year":"2012","journal-title":"J. Endourol."},{"key":"ref_10","doi-asserted-by":"crossref","unstructured":"Carugo, D., Elmahdy, M., Zhao, X., Drake, M.J., Zhang, X., and Clavica, F. (2013, January 3\u20137). An artificial model for studying fluid dynamics in the obstructed and stented ureter. Proceedings of the 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Osaka, Japan.","DOI":"10.1109\/EMBC.2013.6610754"},{"key":"ref_11","first-page":"848","article-title":"Predictive factors for ureteral double-J-stent-related symptoms: A prospective, multivariate analysis","volume":"109","author":"Ho","year":"2010","journal-title":"J. Med. Assoc."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"91","DOI":"10.1159\/000443379","article-title":"Economic Aspects of Morbidity Caused by Ureteral Stents","volume":"97","author":"Staubli","year":"2016","journal-title":"Urol. Int."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"3296","DOI":"10.1039\/c0lc00154f","article-title":"In situ monitoring of antibiotic susceptibility of bacterial biofilms in a microfluidic device","volume":"10","author":"Kim","year":"2010","journal-title":"Lab Chip"},{"key":"ref_14","doi-asserted-by":"crossref","unstructured":"LuTheryn, G., Glynne-Jones, P., Webb, J.S., and Carugo, D. (2019). Ultrasound-mediated therapies for the treatment of biofilms in chronic wounds: A review of present knowledge. Microb. Biotechnol., 613\u2013628.","DOI":"10.1111\/1751-7915.13471"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"563","DOI":"10.1038\/nrmicro.2016.94","article-title":"Biofilms: An emergent form of bacterial life","volume":"14","author":"Flemming","year":"2016","journal-title":"Nat. Rev. Microbiol."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1371\/journal.pone.0172113","article-title":"Impact of wall shear stress on initial bacterial adhesion in rotating annular reactor","volume":"12","author":"Saur","year":"2017","journal-title":"PLoS ONE"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"341","DOI":"10.1016\/j.bpj.2010.11.078","article-title":"Shear stress increases the residence time of adhesion of Pseudomonas aeruginosa","volume":"100","author":"Lecuyer","year":"2011","journal-title":"Biophys. J."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"9818","DOI":"10.3390\/molecules17089818","article-title":"Microfluidic approaches to bacterial biofilm formation","volume":"17","author":"Kim","year":"2012","journal-title":"Molecules"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"639","DOI":"10.1089\/end.2017.0946","article-title":"Particle accumulation in ureteral stents is governed by fluid dynamics: In vitro study using a \u201cstent-on-chip\u201d model","volume":"32","author":"Mosayyebi","year":"2018","journal-title":"J. Endourol."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"014101","DOI":"10.1063\/1.5059370","article-title":"Reducing deposition of encrustation in ureteric stents by changing the stent architecture: A microfluidic-based investigation","volume":"13","author":"Mosayyebi","year":"2019","journal-title":"Biomicrofluidics"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"198","DOI":"10.4111\/kju.2010.51.3.198","article-title":"Investigation of the location of the ureteral stone and diameter of the ureter in patients with renal colic","volume":"51","author":"Song","year":"2010","journal-title":"Korean J. Urol."},{"key":"ref_22","doi-asserted-by":"crossref","unstructured":"Clavica, F., Zhao, X., ElMahdy, M., Drake, M.J., Zhang, X., and Carugo, D. (2014). Investigating the flow dynamics in the obstructed and stented ureter by means of a biomimetic artificial model. PLoS ONE, 9.","DOI":"10.1371\/journal.pone.0087433"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"178","DOI":"10.1016\/j.juro.2017.08.083","article-title":"Evaluation of Biofilm Induced Urinary Infection Stone Formation in a Novel Laboratory Model System","volume":"199","author":"Hobbs","year":"2018","journal-title":"J. Urol."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"671","DOI":"10.1038\/nmeth.2089","article-title":"NIH Image to ImageJ: 25 years of image analysis","volume":"9","author":"Schneider","year":"2012","journal-title":"Nat. Methods"},{"key":"ref_25","doi-asserted-by":"crossref","unstructured":"Zumstein, V., Betschart, P., Albrich, W.C., Buhmann, M.T., Ren, Q., Schmid, H.P., and Abt, D. (2017). Biofilm formation on ureteral stents Incidence, clinical impact and prevention. Swiss Med. Wkly., 147.","DOI":"10.4414\/smw.2017.14408"}],"container-title":["Micromachines"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2072-666X\/11\/4\/408\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,13]],"date-time":"2025-10-13T13:21:07Z","timestamp":1760361667000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2072-666X\/11\/4\/408"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,4,13]]},"references-count":25,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2020,4]]}},"alternative-id":["mi11040408"],"URL":"https:\/\/doi.org\/10.3390\/mi11040408","relation":{},"ISSN":["2072-666X"],"issn-type":[{"value":"2072-666X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,4,13]]}}}