{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,30]],"date-time":"2026-07-30T18:59:42Z","timestamp":1785437982348,"version":"3.56.0"},"reference-count":59,"publisher":"MDPI AG","issue":"6","license":[{"start":{"date-parts":[[2026,6,20]],"date-time":"2026-06-20T00:00:00Z","timestamp":1781913600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100012166","name":"National Key R&D Program of China","doi-asserted-by":"crossref","award":["2023YFC2415000"],"award-info":[{"award-number":["2023YFC2415000"]}],"id":[{"id":"10.13039\/501100012166","id-type":"DOI","asserted-by":"crossref"}]},{"DOI":"10.13039\/501100010881","name":"Suzhou Basic Research Programs","doi-asserted-by":"publisher","award":["SSD2024012"],"award-info":[{"award-number":["SSD2024012"]}],"id":[{"id":"10.13039\/501100010881","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100002367","name":"Chinese Academy of Sciences Basic and Interdisciplinary Frontier Research Program","doi-asserted-by":"publisher","award":["XDB0820101"],"award-info":[{"award-number":["XDB0820101"]}],"id":[{"id":"10.13039\/501100002367","id-type":"DOI","asserted-by":"publisher"}]},{"award":["XDB0820101"],"award-info":[{"award-number":["XDB0820101"]}],"id":[{"id":"https:\/\/ror.org\/034t30j35","id-type":"ROR","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Micromachines"],"abstract":"<jats:p>Preterm infants, especially extremely preterm infants under 28 weeks of gestation, face high mortality rates due to respiratory distress resulting from pulmonary immaturity. Conventional mechanical ventilation and extracorporeal membrane oxygenation (ECMO) therapy inevitably cause irreversible lung injury or severe complications, respectively. Here, we developed a microfluidic oxygenator (MO) mimicking the human alveolar-capillary barrier to provide respiratory support for preterm infants. These structures promoted uniform flow distribution, reduced high-shear stress and flow stagnation, and improved gas exchange efficiency. In vitro experiments demonstrated that a single-layer MO raised blood oxygen saturation from 64.7% to 96.5% at 8 mL\/min, with a corrected vol% oxygen transfer of 5.24% (52.4 mL O2\/L blood). Hemolysis and coagulation measurements after a 6 h circulation confirmed good hemocompatibility, with most blood damage attributable to the pump. An eight-layer stacked MO was configured with a total priming volume of approximately 5.6 mL and a pressure drop of 25\u201335 mmHg at 24\u201340 mL\/min, indicating its potential in pumpless extracorporeal circulation for preterm neonates. This MO holds promise for providing minimally invasive and customizable respiratory support in an artificial uterus system.<\/jats:p>","DOI":"10.3390\/mi17060745","type":"journal-article","created":{"date-parts":[[2026,7,7]],"date-time":"2026-07-07T12:06:43Z","timestamp":1783426003000},"page":"745","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Physiology-Mimicking Microfluidic Oxygenator with Good Hemocompatibility for In Vitro Respiratory Support of Preterm Infants"],"prefix":"10.3390","volume":"17","author":[{"given":"Yu","family":"Tao","sequence":"first","affiliation":[{"name":"School of Biomedical Engineering (Suzhou), University of Science and Technology of China, Hefei 230026, China"},{"name":"Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3712-4915","authenticated-orcid":false,"given":"Yao","family":"Lu","sequence":"additional","affiliation":[{"name":"School of Biomedical Engineering (Suzhou), University of Science and Technology of China, Hefei 230026, China"},{"name":"Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Weijun","family":"Zeng","sequence":"additional","affiliation":[{"name":"School of Biomedical Engineering (Suzhou), University of Science and Technology of China, Hefei 230026, China"},{"name":"Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Donggen","family":"Xiao","sequence":"additional","affiliation":[{"name":"Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0009-6454-7156","authenticated-orcid":false,"given":"Haixuan","family":"Sun","sequence":"additional","affiliation":[{"name":"School of Biomedical Engineering (Suzhou), University of Science and Technology of China, Hefei 230026, China"},{"name":"Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2026,6,20]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1002\/ijgo.13195","article-title":"Global burden of preterm birth","volume":"150","author":"Walani","year":"2020","journal-title":"Int. J. Gynecol. Obstet."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"443","DOI":"10.1542\/peds.2009-2959","article-title":"Neonatal Outcomes of Extremely Preterm Infants from the NICHD Neonatal Research Network","volume":"126","author":"Stoll","year":"2010","journal-title":"Pediatrics"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"179","DOI":"10.1053\/j.sempedsurg.2013.10.005","article-title":"Neonatal Pulmonary Physiology","volume":"22","author":"Davis","year":"2013","journal-title":"Semin. Pediatr. Surg."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"1039","DOI":"10.1001\/jama.2015.10244","article-title":"Trends in Care Practices, Morbidity, and Mortality of Extremely Preterm Neonates","volume":"314","author":"Stoll","year":"2015","journal-title":"J. Am. Med. Assoc."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"e425","DOI":"10.1542\/peds.2012-2189","article-title":"Population-Based Estimates of in-Unit Survival for Very Preterm Infants","volume":"131","author":"Manktelow","year":"2013","journal-title":"Pediatrics"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"637","DOI":"10.1542\/peds.2008-2874","article-title":"Chronic Lung Disease and Developmental Delay at 2 Years of Age in Children Born before 28 Weeks\u2019 Gestation","volume":"124","author":"Laughon","year":"2009","journal-title":"Pediatrics"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"171","DOI":"10.1542\/peds.2013-3442","article-title":"Respiratory Support in Preterm Infants at Birth","volume":"133","author":"Carlo","year":"2014","journal-title":"Pediatrics"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"2126","DOI":"10.1056\/NEJMra1208707","article-title":"Ventilator-Induced Lung Injury","volume":"22","author":"Slutsky","year":"2013","journal-title":"N. Engl. J. Med."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1213\/00000539-198802000-00007","article-title":"The Effect of Incremental Positive End-Expiratory Pressure on Right Ventricular Hemodynamics and Ejection Fraction","volume":"67","author":"Biondi","year":"1988","journal-title":"Anesth. Analg."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"1389","DOI":"10.1113\/JP270926","article-title":"Increase in Pulmonary Blood Flow at Birth: Role of Oxygen and Lung Aeration","volume":"594","author":"Lang","year":"2016","journal-title":"J. Physiol."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"377","DOI":"10.5301\/ijao.5000195","article-title":"Artificial Placenta-Lung Assist Devices for Term and Preterm Newborns with Respiratory Failure","volume":"36","author":"Rochow","year":"2013","journal-title":"Int. J. Artif. Organs"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"506","DOI":"10.1016\/S0022-3476(96)70114-2","article-title":"Relationship between Blood Pressure and Cardiac Output in Preterm Infants Requiring Mechanical Ventilation","volume":"129","author":"Kluckow","year":"1996","journal-title":"J. Pediatr."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"112","DOI":"10.1007\/s002469900127","article-title":"Postnatal Left Ventricular Contractility in Very Low Birth Weight Infants","volume":"18","author":"Takahashi","year":"1997","journal-title":"Pediatr. Cardiol."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"15112","DOI":"10.1038\/ncomms15112","article-title":"An Extra-Uterine System to Physiologically Support the Extreme Premature Lamb","volume":"8","author":"Partridge","year":"2017","journal-title":"Nat. Commun."},{"key":"ref_15","doi-asserted-by":"crossref","unstructured":"Eixarch, E., Illa, M., Fucho, R., Rezaei, K., Hawkins-villarreal, A., Bobillo-p, S., Randanne, P.C., Moran, M., Chorda, M., and Sanchez-martinez, S. (2023). An Artificial Placenta Experimental System in Sheep: Critical Issues for Successful Transition and Survival up to One Week. Biomedicines, 11.","DOI":"10.3390\/biomedicines11030702"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"552","DOI":"10.1097\/MAT.0000000000000676","article-title":"Cerebral Oxygenation of Premature Lambs Supported by an Artificial Placenta","volume":"64","author":"Gray","year":"2018","journal-title":"ASAIO J."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"859","DOI":"10.1046\/j.1525-1594.1998.06121.x","article-title":"Cytokine Release during Long-Term Extracorporeal Circulation in an Experimental Model","volume":"22","author":"Adrian","year":"1998","journal-title":"Artif. Organs"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1080\/09629350220131908","article-title":"Complement Activation by in Vivo Neonatal and in Vitro Extracorporeal Membrane Oxygenation","volume":"11","author":"Graulich","year":"2002","journal-title":"Mediat. Inflamm."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"679","DOI":"10.1203\/00006450-200011000-00021","article-title":"Leukocyte and Endothelial Activation in a Laboratory Model of Extracorporeal Membrane Oxygenation (ECMO)","volume":"48","author":"Graulich","year":"2000","journal-title":"Pediatr. Res."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"387","DOI":"10.1186\/s13054-016-1570-4","article-title":"The Inflammatory Response to Extracorporeal Membrane Oxygenation (ECMO): A Review of the Pathophysiology","volume":"20","author":"Millar","year":"2016","journal-title":"Crit. Care"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"121742","DOI":"10.1016\/j.memsci.2023.121742","article-title":"Effect of Hollow Fiber Configuration and Replacement on the Gas Exchange Performance of Artificial Membrane Lungs","volume":"680","author":"Halfwerk","year":"2023","journal-title":"J. Memb. Sci."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"391","DOI":"10.1111\/aor.12180","article-title":"Flow Dynamics of Different Adult ECMO Systems: A Clinical Evaluation","volume":"38","author":"Lehle","year":"2014","journal-title":"Artif. Organs"},{"key":"ref_23","doi-asserted-by":"crossref","unstructured":"Appelt, H., Philipp, A., Mueller, T., Foltan, M., Lubnow, M., Lunz, D., Zeman, F., and Lehle, K. (2020). Factors Associated with Hemolysis during Extracorporeal Membrane Oxygenation (ECMO)\u2014Comparison of VA- versus VV ECMO. PLoS ONE, 15.","DOI":"10.1371\/journal.pone.0227793"},{"key":"ref_24","doi-asserted-by":"crossref","unstructured":"Thaus, C., Lubnow, M., and Krenkel, L. (2025). Material-Induced Platelet Adhesion\/Activation and Hemolysis of Membrane Lung Components from Extracorporeal Membrane Oxygenation. Biomedicines, 13.","DOI":"10.3390\/biomedicines13102323"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"347","DOI":"10.1177\/03913988241252255","article-title":"Novel Tubing Connectors Reduce ECMO Circuit Thrombosis","volume":"47","author":"Bakshi","year":"2024","journal-title":"Int. J. Artif. Organs"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"190","DOI":"10.1016\/j.actbio.2020.05.008","article-title":"Assessing and Improving the Biocompatibility of Microfluidic Artificial Lungs","volume":"112","author":"Thompson","year":"2020","journal-title":"Acta Biomater."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"044101","DOI":"10.1063\/1.5034791","article-title":"An Artificial Placenta Type Microfluidic Blood Oxygenator with Double-Sided Gas Transfer Microchannels and Its Integration as a Neonatal Lung Assist Device","volume":"12","author":"Dabaghi","year":"2018","journal-title":"Biomicrofluidics"},{"key":"ref_28","doi-asserted-by":"crossref","unstructured":"Ma, L.J., Akor, E.A., Thompson, A.J., and Potkay, J.A. (2022). A Parametric Analysis of Capillary Height in Single-Layer, Small-Scale Microfluidic Artificial Lungs. Micromachines, 13.","DOI":"10.3390\/mi13060822"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"2001860","DOI":"10.1002\/advs.202001860","article-title":"A Pumpless Microfluidic Neonatal Lung Assist Device for Support of Preterm Neonates in Respiratory Distress","volume":"7","author":"Dabaghi","year":"2020","journal-title":"Adv. Sci."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"1686","DOI":"10.1039\/c2lc21156d","article-title":"Performance and Scaling Effects in a Multilayer Microfluidic Extracorporeal Lung Oxygenation Device","volume":"12","author":"Kniazeva","year":"2012","journal-title":"Lab Chip"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"2641","DOI":"10.1039\/c3lc41417e","article-title":"Lung Assist Device: Development of Microfluidic Oxygenators for Preterm Infants with Respiratory Failure","volume":"13","author":"Wu","year":"2013","journal-title":"Lab Chip"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"700","DOI":"10.1039\/C0LC00158A","article-title":"Lung Assist Device Technology with Physiologic Blood Flow Developed on a Tissue Engineered Scaffold Platform","volume":"11","author":"Hoganson","year":"2011","journal-title":"Lab Chip"},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"1312","DOI":"10.1097\/MAT.0000000000001647","article-title":"Multilayer Scaling of a Biomimetic Microfluidic Oxygenator","volume":"68","author":"Vedula","year":"2022","journal-title":"ASAIO J."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"4637","DOI":"10.1039\/D1LC00287B","article-title":"Design and Construction of Three-Dimensional Physiologically-Based Vascular Branching Networks for Respiratory Assist Devices","volume":"21","author":"Santos","year":"2021","journal-title":"Lab Chip"},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"e2207455","DOI":"10.1002\/advs.202207455","article-title":"A Clinical-Scale Microfluidic Respiratory Assist Device with 3D Branching Vascular Networks","volume":"10","author":"Isenberg","year":"2023","journal-title":"Adv. Sci."},{"key":"ref_36","doi-asserted-by":"crossref","unstructured":"Imtiaz, N., Poskus, M.D., Stoddard, W.A., Gaborski, T.R., and Day, S.W. (2024). Empirical and Computational Evaluation of Hemolysis in a Microfluidic Extracorporeal Membrane Oxygenator Prototype. Micromachines, 15.","DOI":"10.3390\/mi15060790"},{"key":"ref_37","doi-asserted-by":"crossref","unstructured":"Bruus, H. (2014). Governing Equations in Microfluidics. Microscale Acoustofluidics, Royal Society of Chemistry.","DOI":"10.1039\/9781849737067-00001"},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1073\/pnas.12.3.207","article-title":"The Physiological Principle of Minimum Work: I. The Vascular System and the Cost of Blood Volume","volume":"12","author":"Murray","year":"1926","journal-title":"Proc. Natl. Acad. Sci. USA"},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"835","DOI":"10.1085\/jgp.9.6.835","article-title":"The Physiological Principle of Minimum Work Applied to the Angle of Branching of Arteries","volume":"9","author":"Murray","year":"1926","journal-title":"J. Gen. Physiol."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"4122","DOI":"10.1039\/C4LC00828F","article-title":"The Promise of Microfluidic Artificial Lungs","volume":"14","author":"Potkay","year":"2014","journal-title":"Lab Chip"},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"397","DOI":"10.1007\/s10544-013-9736-1","article-title":"A Simple, Closed-Form, Mathematical Model for Gas Exchange in Microchannel Artificial Lungs","volume":"15","author":"Potkay","year":"2013","journal-title":"Biomed. Microdevices"},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"2901","DOI":"10.1039\/c1lc20020h","article-title":"Bio-Inspired, Efficient, Artificial Lung Employing Air as the Ventilating Gas","volume":"11","author":"Potkay","year":"2011","journal-title":"Lab Chip"},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"990","DOI":"10.1016\/j.jtcvs.2010.02.062","article-title":"Branched Vascular Network Architecture: A New Approach to Lung Assist Device Technology","volume":"140","author":"Hoganson","year":"2010","journal-title":"J. Thorac. Cardiovasc. Surg."},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"390","DOI":"10.1097\/MAT.0b013e31817eda02","article-title":"Microchannel Technologies for Artificial Lungs: (3) Open Rectangular Channels","volume":"54","author":"Lee","year":"2008","journal-title":"ASAIO J."},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"1082","DOI":"10.1109\/TBME.2018.2866782","article-title":"Design Analysis and Optimization of a Single-Layer PDMS Microfluidic Artificial Lung","volume":"66","author":"Thompson","year":"2019","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_46","first-page":"iv","article-title":"The Possible Effects of the Aggregation of the Molecules of H\u00e6moglobin on Its Dissociation Curves","volume":"40","author":"Hill","year":"1910","journal-title":"J. Physiol."},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1053\/j.semperi.2003.11.004","article-title":"Neonatal Blood Pressure Regulation","volume":"28","author":"Jones","year":"2004","journal-title":"Semin. Perinatol."},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"431","DOI":"10.1085\/jgp.78.4.431","article-title":"On Connecting Large Vessels to Small. The Meaning of Murray\u2019s Law","volume":"78","author":"Sherman","year":"1981","journal-title":"J. Gen. Physiol."},{"key":"ref_49","first-page":"599","article-title":"Simple, Accurate Equations for Human Blood O2 Dissociation Computations","volume":"46","author":"Severinghaus","year":"1979","journal-title":"J. Appl. Physiol. Respir. Environ. Exerc. Physiol."},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"E247","DOI":"10.1111\/aor.13935","article-title":"A High Gas Transfer Efficiency Microfluidic Oxygenator for Extracorporeal Respiratory Assist Applications in Critical Care Medicine","volume":"45","author":"Gimbel","year":"2021","journal-title":"Artif. Organs"},{"key":"ref_51","unstructured":"Whitmore, R. (1968). Rheology of the Circulation, Pergamon Press."},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"415","DOI":"10.1055\/s-0038-1661576","article-title":"Rheological Aspects of Thrombosis and Hae Mostasis: Basic Principles and Applications","volume":"55","author":"Goldsmith","year":"1986","journal-title":"Thromb. Haemost."},{"key":"ref_53","doi-asserted-by":"crossref","first-page":"e2210819119","DOI":"10.1073\/pnas.2210819119","article-title":"Fatigue of Red Blood Cells under Periodic Squeezes in ECMO","volume":"119","author":"Pan","year":"2022","journal-title":"Proc. Natl. Acad. Sci. USA"},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"1180","DOI":"10.1111\/j.1525-1594.2011.01243.x","article-title":"Study of Flow-Induced Hemolysis Using Novel Couette-Type Blood-Shearing Devices","volume":"35","author":"Zhang","year":"2011","journal-title":"Artif. Organs"},{"key":"ref_55","unstructured":"(2017). Standard Practice for Assessment of Hemolytic Properties of Materials (Standard No. ASTM F756-17)."},{"key":"ref_56","doi-asserted-by":"crossref","first-page":"96","DOI":"10.1097\/MAT.0b013e31818fb9fb","article-title":"Hemodynamic Energy Delivery of the Pulsatile Flow in a Simulated Pediatric Extracorporeal Circuit","volume":"55","author":"Wang","year":"2009","journal-title":"ASAIO J."},{"key":"ref_57","doi-asserted-by":"crossref","first-page":"4791","DOI":"10.1039\/D1LC00356A","article-title":"A compact integrated microfluidic oxygenator with high gas exchange efficiency and compatibility for long-lasting endothelialization","volume":"21","author":"Lachaux","year":"2021","journal-title":"Lab Chip"},{"key":"ref_58","doi-asserted-by":"crossref","first-page":"4612","DOI":"10.1021\/acsbiomaterials.3c01635","article-title":"Scaled-up Microfluidic Lung Assist Device for Artificial Placenta Application with High Gas Exchange Capacity","volume":"10","author":"Saraei","year":"2024","journal-title":"ACS Biomater. Sci. Eng."},{"key":"ref_59","doi-asserted-by":"crossref","first-page":"e70037","DOI":"10.1002\/btm2.70037","article-title":"A silicon membrane microfluidic oxygenator for use as an artificial placenta with minimal anticoagulation","volume":"10","author":"Blauvelt","year":"2025","journal-title":"Bioeng. Transl. Med."}],"container-title":["Micromachines"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2072-666X\/17\/6\/745\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,8]],"date-time":"2026-07-08T04:13:49Z","timestamp":1783484029000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2072-666X\/17\/6\/745"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,20]]},"references-count":59,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2026,6]]}},"alternative-id":["mi17060745"],"URL":"https:\/\/doi.org\/10.3390\/mi17060745","relation":{},"ISSN":["2072-666X"],"issn-type":[{"value":"2072-666X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,6,20]]}}}