{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,6]],"date-time":"2026-07-06T15:19:43Z","timestamp":1783351183707,"version":"3.54.6"},"reference-count":20,"publisher":"MDPI AG","issue":"7","license":[{"start":{"date-parts":[[2026,7,6]],"date-time":"2026-07-06T00:00:00Z","timestamp":1783296000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Presidential Foundation of CAEP","award":["YZJJZL2025008"],"award-info":[{"award-number":["YZJJZL2025008"]}]},{"DOI":"10.13039\/501100013287","name":"Science Challenge Project","doi-asserted-by":"publisher","award":["TZ202515"],"award-info":[{"award-number":["TZ202515"]}],"id":[{"id":"10.13039\/501100013287","id-type":"DOI","asserted-by":"publisher"}]},{"name":"National Key Laboratory on Advanced Laser and High-Power Microwave","award":["LMLB202404002"],"award-info":[{"award-number":["LMLB202404002"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Micromachines"],"abstract":"<jats:p>The high sensitivity of HgCdTe infrared detectors makes them highly vulnerable to laser irradiation, yet the influence of pulse width on damage behavior in the short-wave infrared (SWIR) band remains insufficiently understood. In this study, we experimentally and numerically investigate the damage effects of SWIR pulsed lasers on HgCdTe focal plane array detectors, focusing on the role of pulse width. Three lasers with pulse widths of 5.5 ns, 0.6 ms and 2 ms are used to irradiate the detector, and the damage thresholds for spot damage, line damage, and complete failure are measured. Damage morphologies are characterized by optical microscopy and scanning electron microscopy. A finite-element thermal model is also established to calculate transient temperature distributions and theoretical damage thresholds. For the 0.6 ms pulse, the measured thresholds for spot damage, line damage, and complete failure are 5.7 J\/cm2, 65.4 J\/cm2, and 157.3 J\/cm2, respectively; for the 2 ms pulse, these increase to 12.1 J\/cm2, 149.3 J\/cm2, and 405 J\/cm2 due to energy dispersion. Microscopic analysis reveals that spot damage arises from melting of HgCdTe and indium bumps, line damage from partial damage to the read-out integrated circuit (ROIC) layer, and complete failure from melt-through of the ROIC layer. The spot damage threshold of the 5.5 ns pulse is 1.2 J\/cm2, while neither line damage nor complete failure occurs even with a 352.5 J\/cm2 laser pulse, indicating different damage mechanisms due to a thermal confinement effect. The simulation results agree well with the experimental observations. These findings clarify the pulse-width dependence of damage thresholds and provide practical guidance for detector hardening and photoelectric countermeasure design.<\/jats:p>","DOI":"10.3390\/mi17070813","type":"journal-article","created":{"date-parts":[[2026,7,6]],"date-time":"2026-07-06T14:56:42Z","timestamp":1783349802000},"page":"813","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["The Damage Effects on a HgCdTe Detector of a Short-Infrared Pulsed Laser with Different Pulse Widths"],"prefix":"10.3390","volume":"17","author":[{"given":"Qiheng","family":"Wei","sequence":"first","affiliation":[{"name":"Institute of Fluid Physics, China Academy of Engineering Physics, Mianyang 621900, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xianfeng","family":"Wu","sequence":"additional","affiliation":[{"name":"Institute of Fluid Physics, China Academy of Engineering Physics, Mianyang 621900, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lingyuan","family":"Wu","sequence":"additional","affiliation":[{"name":"Institute of Fluid Physics, China Academy of Engineering Physics, Mianyang 621900, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yongqiang","family":"Zhang","sequence":"additional","affiliation":[{"name":"Institute of Fluid Physics, China Academy of Engineering Physics, Mianyang 621900, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fuli","family":"Tan","sequence":"additional","affiliation":[{"name":"Institute of Fluid Physics, China Academy of Engineering Physics, Mianyang 621900, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bo","family":"Fu","sequence":"additional","affiliation":[{"name":"Institute of Fluid Physics, China Academy of Engineering Physics, Mianyang 621900, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wei","family":"Li","sequence":"additional","affiliation":[{"name":"Institute of Fluid Physics, China Academy of Engineering Physics, Mianyang 621900, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yanglong","family":"Li","sequence":"additional","affiliation":[{"name":"Institute of Fluid Physics, China Academy of Engineering Physics, Mianyang 621900, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2026,7,6]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"325","DOI":"10.1016\/0022-3697(59)90110-6","article-title":"Preparation and Properties of HgTe and Mixed Crystals of HgTe-CdTe","volume":"9","author":"Lawson","year":"1959","journal-title":"J. Phys. Chem. Solids"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"2267","DOI":"10.1088\/0034-4885\/68\/10\/R01","article-title":"HgCdTe Infrared Detector Material: History, Status and Outlook","volume":"68","author":"Rogalski","year":"2005","journal-title":"Rep. Prog. Phys."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"091101","DOI":"10.1063\/1.3099572","article-title":"Third-Generation Infrared Photodetector Arrays","volume":"105","author":"Rogalski","year":"2009","journal-title":"J. Appl. Phys."},{"key":"ref_4","doi-asserted-by":"crossref","unstructured":"Kopytko, M., Sobieski, J., Gawron, W., and Martyniuk, P. (2022). Study of HgCdTe (100) and HgCdTe (111)B Heterostructures Grown by MOCVD and Their Potential Application to APDs Operating in the IR Range up to 8 \u00b5m. Sensors, 22.","DOI":"10.3390\/s22030924"},{"key":"ref_5","doi-asserted-by":"crossref","unstructured":"Madejczyk, P., Manyk, T., and Rutkowski, J. (2023). Research on Electro-Optical Characteristics of Infrared Detectors with HgCdTe Operating at Room Temperature. Sensors, 23.","DOI":"10.3390\/s23031088"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"6074","DOI":"10.1007\/s11664-019-07177-8","article-title":"MCT-Based High Performance Bispectral Detectors by AIM","volume":"48","author":"Eich","year":"2019","journal-title":"J. Electron. Mater."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"109433","DOI":"10.1016\/j.optlastec.2023.109433","article-title":"Laser-Interfered Studies in HgCdTe Infrared Focal Plane Array Detector by High-Repetition-Rate Mid-Infrared Supercontinuum Fiber Laser","volume":"163","author":"Wang","year":"2023","journal-title":"Opt. Laser Technol."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"172","DOI":"10.1016\/j.optlastec.2013.10.023","article-title":"Analysis of Damage Threshold on HgCdTe Crystal Irradiated by Multi-pulsed CO2 laser","volume":"58","author":"Tang","year":"2014","journal-title":"Opt. Laser Technol."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"3713","DOI":"10.1063\/1.1662827","article-title":"Laser Damage in Triglycine Sulfate\u2014Experimental Results and Thermal Analysis","volume":"44","author":"Bartoli","year":"1973","journal-title":"J. Appl. Phys."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"4519","DOI":"10.1063\/1.321387","article-title":"Thermal Modeling of Laser Damage in 8\u201314 \u03bcm HgCdTe Photoconductive and PbSnTe Photovoltaic Detectors","volume":"46","author":"Bartoli","year":"1975","journal-title":"J. Appl. Phys."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"2875","DOI":"10.1063\/1.323064","article-title":"A Generalized Thermal Model for Laser Damage in Infrared Detectors","volume":"47","author":"Bartoli","year":"1976","journal-title":"J. Appl. Phys."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"2499","DOI":"10.1364\/AO.14.002499","article-title":"Thermal Recovery Processes in Laser Irradiated HgCdTe (PC) detectors","volume":"14","author":"Bartoli","year":"1975","journal-title":"Appl. Opt."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"0214002","DOI":"10.3788\/AOS201333.0214002","article-title":"Experimental Study of HgCdTe Imaging Sensor Irradiated by TEA-CO2 Laser","volume":"33","author":"Lei","year":"2013","journal-title":"Acta Opt. Sin."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"1217","DOI":"10.37188\/OPE.20212906.1217","article-title":"Damage Effect of TEA CO2 Long Wave Infrared Laser on Detector Assembly of Infrared Staring Imaging System","volume":"29","author":"Zhang","year":"2021","journal-title":"Opt. Precis. Eng."},{"key":"ref_15","doi-asserted-by":"crossref","unstructured":"Liu, Y., Zhou, F., Wang, Y., Zhang, Y., Zhang, Y., Zheng, H., and Shao, J. (2024). Experimental Study on Damage Effect of Mid-Infrared Pulsed Laser on Charge Coupled Device (CCD) and HgCdTe Detectors. Sensors, 24.","DOI":"10.3390\/s24134380"},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"Zhang, Y., Zheng, C., Liu, Y., Wang, Y., Xu, Y., and Shao, J. (2023). Damage Mechanism of HgCdTe Focal Plane Array Detector Irradiated Using Mid-Infrared Pulse Laser. Sensors, 23.","DOI":"10.3390\/s23239370"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"88","DOI":"10.1088\/1464-4258\/8\/1\/014","article-title":"Analysis of Laser Damage Threshold and Morphological Changes at the Surface of a HgCdTe Crystal","volume":"8","author":"Chen","year":"2006","journal-title":"J. Opt. A Pure Appl. Opt."},{"key":"ref_18","first-page":"3057266","article-title":"The Enhancement Laser Dazzling Effect Induced by CW Laser Combined with Nanosecond Laser","volume":"13543","author":"Li","year":"2025","journal-title":"Proc. SPIE"},{"key":"ref_19","doi-asserted-by":"crossref","unstructured":"Ma, Y., Zhou, W., Chang, H., and Jian, Z. (2024). Laser-Induced Interference to Infrared Detector Using Continuous Wave and Short-Pulse Lasers. Sensors, 24.","DOI":"10.3390\/s24154885"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"105941","DOI":"10.1016\/j.infrared.2025.105941","article-title":"Thermo-mechanical simulations of pulsed CO2 laser-HgCdTe detector","volume":"150","author":"Gao","year":"2025","journal-title":"Infrared Phys. Technol."}],"container-title":["Micromachines"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2072-666X\/17\/7\/813\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,6]],"date-time":"2026-07-06T15:05:28Z","timestamp":1783350328000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2072-666X\/17\/7\/813"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,6]]},"references-count":20,"journal-issue":{"issue":"7","published-online":{"date-parts":[[2026,7]]}},"alternative-id":["mi17070813"],"URL":"https:\/\/doi.org\/10.3390\/mi17070813","relation":{},"ISSN":["2072-666X"],"issn-type":[{"value":"2072-666X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,6]]}}}