{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,16]],"date-time":"2026-07-16T09:04:56Z","timestamp":1784192696671,"version":"3.55.0"},"reference-count":42,"publisher":"MDPI AG","issue":"7","license":[{"start":{"date-parts":[[2026,7,15]],"date-time":"2026-07-15T00:00:00Z","timestamp":1784073600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Heilongjiang Province\u2019s Key Research and Development Project","award":["2023ZXJ03C02"],"award-info":[{"award-number":["2023ZXJ03C02"]}]},{"name":"Harbin Manufacturing Industry Science and Technology Innovation Talent Program","award":["2023CXRCGD031"],"award-info":[{"award-number":["2023CXRCGD031"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Micromachines"],"abstract":"<jats:p>Droplet splitting technology on open digital microfluidic platforms still faces significant challenges in terms of process complexity, the degree of automation, and operating conditions, which hinder its further development. This study proposes a fully automated method for precise droplet splitting based on printed circuit boards with open-coplanar asymmetric electrodes and a slippery liquid-infused porous surface. This method uses simple square electrodes arranged in a 3 \u00d7 5 array, combined with low-adhesion blade-assisted cutting and electrowetting-on-dielectric to drive droplet splitting, enabling accurate, stable, and repeatable automated droplet splitting on an open digital microfluidic platform. It has the advantages of a simple method, easy maintenance and integration, and high automation. This study systematically investigated the effects of droplet volume, applied voltage, blade thickness, cutting speed, and electrode shape on droplet splitting performance. We developed an active droplet position calibration method based on a simple 3 \u00d7 3 square electrode array combined with an enveloping voltage configuration strategy. For droplets with a volume of 10 \u03bcL, the positioning error can be controlled to within 0.06 mm, representing a reduction of more than 95% compared to the conventional EWOD free drive method. The experimental results show that to achieve stable and approximately equal-volume droplet splitting, the cutting speed needs to exceed the critical value related to the blade thickness. Among the square, zigzag, and hexagonal electrode shapes tested, the square electrode required the lowest splitting voltage. When the blade thickness is 0.3 mm, the droplets can be successfully split at a minimum voltage of 165 V. After increasing the splitting voltage to 400 V, the droplet splitting time was reduced from 5.57 s to 0.27 s, with a reduction of 95.2%, which significantly improves droplet splitting efficiency. This method provides a practical, stable, automated, and precise droplet splitting method for sample preparation, biochemical reactions, and portable droplet analysis systems.<\/jats:p>","DOI":"10.3390\/mi17070839","type":"journal-article","created":{"date-parts":[[2026,7,16]],"date-time":"2026-07-16T08:08:34Z","timestamp":1784189314000},"page":"839","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["A Self-Centering, Blade-Assisted, Electrowetting-Enabled Strategy for Precise Droplet Splitting on Open Digital Microfluidic Platforms"],"prefix":"10.3390","volume":"17","author":[{"given":"Hao","family":"Liang","sequence":"first","affiliation":[{"name":"School of Astronautics, Harbin Institute of Technology, Harbin 150001, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Liang","family":"Chen","sequence":"additional","affiliation":[{"name":"School of Astronautics, Harbin Institute of Technology, Harbin 150001, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4917-746X","authenticated-orcid":false,"given":"Haifeng","family":"Zhang","sequence":"additional","affiliation":[{"name":"School of Astronautics, Harbin Institute of Technology, Harbin 150001, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiaowei","family":"Liu","sequence":"additional","affiliation":[{"name":"School of Astronautics, Harbin Institute of Technology, Harbin 150001, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2026,7,15]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"78","DOI":"10.1038\/s41378-025-00940-4","article-title":"Recent advances in bio-microsystem integration and Lab-on-PCB technology","volume":"11","author":"Papamatthaiou","year":"2025","journal-title":"Microsyst. Nanoeng."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"4197","DOI":"10.1021\/acs.langmuir.8b04136","article-title":"Apparent Contact Angles on Lubricant-Impregnated Surfaces\/SLIPS: From Superhydrophobicity to Electrowetting","volume":"35","author":"McHale","year":"2019","journal-title":"Langmuir"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"70166","DOI":"10.1021\/acsami.5c09237","article-title":"Enhancing Digital Microfluidics: A Comprehensive Investigation into the Performance of Slippery Liquid-Infused Porous Surfaces","volume":"17","author":"Kalyani","year":"2025","journal-title":"ACS Appl. Mater. Interfaces"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"591","DOI":"10.1016\/j.tibtech.2023.11.002","article-title":"Printed circuit boards: System automation and alternative matrix for biosensing","volume":"42","author":"Mahapatra","year":"2024","journal-title":"Trends Biotechnol."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"43522","DOI":"10.1109\/JSEN.2025.3622368","article-title":"Easy-to-Fabricate Digital Microfluidic Chip Based on PCB With Glucose Enzyme-Free Detection Function","volume":"25","author":"Huang","year":"2025","journal-title":"IEEE Sens. J."},{"key":"ref_6","doi-asserted-by":"crossref","unstructured":"Yi, Z.C., Feng, H.Q., Zhou, X.F., and Shui, L.L. (2020). Design of an Open Electrowetting on Dielectric Device Based on Printed Circuit Board by Using a Parafilm M. Front. Phys., 8.","DOI":"10.3389\/fphy.2020.00193"},{"key":"ref_7","doi-asserted-by":"crossref","unstructured":"Feng, H.Q., Yi, Z.C., Yang, R.Z., Qin, X.F., Shen, S.T., Zeng, W.J., Shui, L.L., Zhou, G.F., and Zhang, C.F. (2020). Designing Splicing Digital Microfluidics Chips Based on Polytetrafluoroethylene Membrane. Micromachines, 11.","DOI":"10.3390\/mi11121067"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s40486-023-00192-9","article-title":"PCB-based digital microfluidic platform for droplet mixing on an open surface","volume":"12","author":"Kim","year":"2024","journal-title":"Micro Nano Syst. Lett."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"896","DOI":"10.1039\/C6LC01539E","article-title":"A 3D microblade structure for precise and parallel droplet splitting on digital microfluidic chips","volume":"17","author":"Dong","year":"2017","journal-title":"Lab Chip"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"9540","DOI":"10.1021\/acs.langmuir.0c01543","article-title":"Stripped Electrode Based Electrowetting-on-Dielectric Digital Microfluidics for Precise and Controllable Parallel Microdrop Generation","volume":"36","author":"Guan","year":"2020","journal-title":"Langmuir"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"051304","DOI":"10.1063\/5.0267868","article-title":"Droplet splitting in microfluidics: A review","volume":"37","author":"Agnihotri","year":"2025","journal-title":"Phys. Fluids"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"242","DOI":"10.1007\/s13206-020-4302-4","article-title":"A Numerical Study of Droplet Splitting using Different Spacers in EWOD Device","volume":"14","author":"Wang","year":"2020","journal-title":"BioChip J."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"1886","DOI":"10.1039\/D1LC00101A","article-title":"A robust and scalable active-matrix driven digital microfluidic platform based on printed-circuit board technology","volume":"21","author":"Xing","year":"2021","journal-title":"Lab Chip"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"3266","DOI":"10.1021\/la200258u","article-title":"Non-Stick Droplet Surgery with a Superhydrophobic Scalpel","volume":"27","author":"Bormashenko","year":"2011","journal-title":"Langmuir"},{"key":"ref_15","doi-asserted-by":"crossref","unstructured":"Yanashima, R., Garc\u00eda, A.A., Aldridge, J., Weiss, N., Hayes, M.A., and Andrews, J.H. (2012). Cutting a Drop of Water Pinned by Wire Loops Using a Superhydrophobic Surface and Knife. PLoS ONE, 7.","DOI":"10.1371\/journal.pone.0045893"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"748","DOI":"10.1039\/D2LC00849A","article-title":"Robotic digital microfluidics: A droplet-based total analysis system","volume":"23","author":"Kiani","year":"2022","journal-title":"Lab Chip"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"6420","DOI":"10.1021\/jacs.2c13674","article-title":"Noncontact Charge Shielding Knife for Liquid Microfluidics","volume":"145","author":"Han","year":"2023","journal-title":"J. Am. Chem. Soc."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"2200240","DOI":"10.1002\/admi.202200240","article-title":"Open-Chip Droplet Splitting in Electrowetting","volume":"9","author":"Sagar","year":"2022","journal-title":"Adv. Mater. Interfaces"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"137765","DOI":"10.1016\/j.snb.2025.137765","article-title":"Efficient in-droplet concentration of particles for digital microfluidics on coplanar electrodes by integrating electrowetting-on-dielectric (EWOD) and surface acoustic wave (SAW) technologies","volume":"438","author":"Chen","year":"2025","journal-title":"Sens. Actuator B Chem."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"5211","DOI":"10.1039\/C9SM00812H","article-title":"Droplet manipulation with polarity-dependent low-voltage electrowetting on an open slippery liquid infused porous surface","volume":"15","author":"He","year":"2019","journal-title":"Soft Matter"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"1330","DOI":"10.1039\/b704084a","article-title":"Asymmetric electrowetting\u2014Moving droplets by a square wave","volume":"7","author":"Fan","year":"2007","journal-title":"Lab Chip"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"106401","DOI":"10.1016\/j.rinp.2023.106401","article-title":"Asymmetric electrodes for droplet directional actuation by a square wave on an open surface","volume":"48","author":"He","year":"2023","journal-title":"Results Phys."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"114299","DOI":"10.1016\/j.sna.2023.114299","article-title":"Minimum movable droplet volume in digital microfluidics depends on the grounding scheme in addition to electrode size","volume":"355","author":"Abdelgawad","year":"2023","journal-title":"Sens. Actuator A Phys."},{"key":"ref_24","doi-asserted-by":"crossref","unstructured":"Alistar, M., and Gaudenz, U. (2017). Opendrop: An integrated do-it-yourself platform for personal use of biochips. Bioengineering, 4.","DOI":"10.3390\/bioengineering4020045"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"094506","DOI":"10.1063\/1.3117216","article-title":"Optimization of device geometry in single-plate digital microfluidics","volume":"105","author":"Abdelgawad","year":"2009","journal-title":"J. Appl. Phys."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"13522","DOI":"10.1021\/acs.langmuir.7b03604","article-title":"Underwater Oil Droplet Splitting on a Patterned Template","volume":"33","author":"Yang","year":"2017","journal-title":"Langmuir"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"3642","DOI":"10.1039\/c1lc20390h","article-title":"Droplet-driven transports on superhydrophobic-patterned surface microfluidics","volume":"11","author":"Xing","year":"2011","journal-title":"Lab Chip"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"682","DOI":"10.1039\/b501781e","article-title":"Behaviour and design considerations for continuous flow closed-open-closed liquid microchannels","volume":"5","author":"Melin","year":"2005","journal-title":"Lab Chip"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"16815","DOI":"10.1039\/D3RA01817B","article-title":"Research progress of electrode shapes in EWOD-based digital microfluidics","volume":"13","author":"Wu","year":"2023","journal-title":"RSC Adv."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"204701","DOI":"10.1063\/5.0118241","article-title":"Lubrication effects on droplet manipulation by electrowetting-on-dielectric (EWOD)","volume":"132","author":"Yamamoto","year":"2022","journal-title":"J. Appl. Phys."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"A19","DOI":"10.1017\/jfm.2021.677","article-title":"Dynamics of droplets under electrowetting effect with voltages exceeding the contact angle saturation threshold","volume":"925","author":"Vo","year":"2021","journal-title":"J. Fluid Mech."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"8434","DOI":"10.1039\/D3SM01178J","article-title":"Droplet detachment force and its relation to Young-Dupre adhesion","volume":"19","author":"Daniel","year":"2023","journal-title":"Soft Matter"},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"89","DOI":"10.1038\/s42005-024-01582-0","article-title":"Predicting droplet detachment force: Young-Dupr\u00e9 Model Fails, Young-Laplace Model Prevails","volume":"7","author":"Sadullah","year":"2024","journal-title":"Commun. Phys."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"8114","DOI":"10.1039\/D0SM00766H","article-title":"Factors controlling the pinning force of liquid droplets on liquid infused surfaces","volume":"16","author":"Sadullah","year":"2020","journal-title":"Soft Matter"},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"306","DOI":"10.1038\/s42005-024-01795-3","article-title":"Direct visualization of viscous dissipation and wetting ridge geometry on lubricant-infused surfaces","volume":"7","author":"Naga","year":"2024","journal-title":"Commun. Phys."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"7136","DOI":"10.1038\/s41467-021-27503-1","article-title":"Wetting ridge assisted programmed magnetic actuation of droplets on ferrofluid-infused surface","volume":"12","author":"Zhang","year":"2021","journal-title":"Nat. Commun."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"113734","DOI":"10.1016\/j.sna.2022.113734","article-title":"Experimental and theoretical study of electrowetting dynamics on slippery lubricant-infused porous surfaces","volume":"344","author":"He","year":"2022","journal-title":"Sens. Actuator A-Phys."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"8517","DOI":"10.1021\/acsnano.9b04129","article-title":"Liquid-Infused Surfaces: A Review of Theory, Design, and Applications","volume":"13","author":"Villegas","year":"2019","journal-title":"ACS Nano"},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"4901","DOI":"10.1038\/s41467-023-40279-w","article-title":"Droplet attraction and coalescence mechanism on textured oil-impregnated surfaces","volume":"14","author":"Xu","year":"2023","journal-title":"Nat. Commun."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"351","DOI":"10.1038\/s41467-022-28016-1","article-title":"Nanobubbles explain the large slip observed on lubricant-infused surfaces","volume":"13","author":"Zhu","year":"2022","journal-title":"Nat. Commun."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1016\/j.elstat.2017.02.006","article-title":"Effect of electrode geometry on droplet velocity in open EWOD based device for digital microfluidics applications","volume":"87","author":"Jain","year":"2017","journal-title":"J. Electrost."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"2275","DOI":"10.1039\/C9LC00289H","article-title":"Antifouling digital microfluidics using lubricant infused porous film","volume":"19","author":"Geng","year":"2019","journal-title":"Lab Chip"}],"container-title":["Micromachines"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2072-666X\/17\/7\/839\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,16]],"date-time":"2026-07-16T08:27:20Z","timestamp":1784190440000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2072-666X\/17\/7\/839"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,15]]},"references-count":42,"journal-issue":{"issue":"7","published-online":{"date-parts":[[2026,7]]}},"alternative-id":["mi17070839"],"URL":"https:\/\/doi.org\/10.3390\/mi17070839","relation":{},"ISSN":["2072-666X"],"issn-type":[{"value":"2072-666X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,15]]}}}