{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,24]],"date-time":"2026-08-24T18:21:03Z","timestamp":1787595663228,"version":"build-2736575974"},"reference-count":98,"publisher":"MDPI AG","issue":"9","license":[{"start":{"date-parts":[[2026,8,24]],"date-time":"2026-08-24T00:00:00Z","timestamp":1787529600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Micromachines"],"abstract":"<jats:p>Wireless power transfer (WPT) has emerged as a promising technology for modern implantable medical devices (IMDs), providing a reliable alternative to traditional batteries and reducing the need for repeat surgical procedures. WPT-based IMDs are extensively employed in biomedical applications such as deep brain stimulators, endoscopic capsules, pacemakers, and cardiac monitoring systems, which are being commercialized. As the IMD market is expected to grow with the aging population, extensive research efforts are proceeding to address key design and implementation challenges. A key challenge lies in simultaneously achieving high power-transfer efficiency (PTE), high data rates, low power consumption, and low circuit complexity. This review paper thoroughly examines recent developments, design trends, and current research problems in simultaneous power and bidirectional data transmission over a single inductive link, as well as the associated modulation and demodulation techniques. We reviewed various uplink and downlink modulation techniques, focusing on key characteristics such as data rate, power consumption, circuit complexity, and health and safety considerations. Finally, future research directions toward efficient, compact, and reliable simultaneous wireless power and data transfer (SWPDT) for the next generation of IMDs are discussed. This review paper will hopefully guide ongoing research into more efficient, scalable, and safe SWPDT systems.<\/jats:p>","DOI":"10.3390\/mi17090998","type":"journal-article","created":{"date-parts":[[2026,8,24]],"date-time":"2026-08-24T17:20:28Z","timestamp":1787592028000},"page":"998","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Wireless Power and Data Transfer over Inductive Links for Biomedical Applications: Recent Advances, Challenges, and Limitations"],"prefix":"10.3390","volume":"17","author":[{"ORCID":"https:\/\/orcid.org\/0009-0009-2125-2753","authenticated-orcid":false,"given":"Naqeeb","family":"Ullah","sequence":"first","affiliation":[{"name":"Graduate School of Information Science and Electrical Engineering, Kyushu University, Fukuoka 819-0396, Japan"},{"name":"Electronic Engineering Department, Faculty of Information and Communication Technology, Balochistan University of Information Technology, Engineering and Management Sciences (BUITEMS), Quetta 87300, Balochistan, Pakistan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0270-5480","authenticated-orcid":false,"given":"Adel","family":"Barakat","sequence":"additional","affiliation":[{"name":"Graduate School of Information Science and Electrical Engineering, Kyushu University, Fukuoka 819-0396, Japan"},{"name":"eSync SSB, Inc., Fukuoka 814-0001, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0357-2306","authenticated-orcid":false,"given":"Haruichi","family":"Kanaya","sequence":"additional","affiliation":[{"name":"Graduate School of Information Science and Electrical Engineering, Kyushu University, Fukuoka 819-0396, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2026,8,24]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1016\/j.eng.2021.10.019","article-title":"Recent Advances in Organ-Specific Wireless Bioelectronic Devices: Perspective on Biotelemetry and Power Transfer Using Antenna Systems","volume":"11","author":"Khan","year":"2022","journal-title":"Engineering"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"1875","DOI":"10.1002\/cta.70080","article-title":"Wireless Power Transfer for Biomedical Implants","volume":"54","author":"Aboualalaa","year":"2025","journal-title":"Int. J. Circuit Theory Appl."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"1139","DOI":"10.1109\/ACCESS.2018.2885620","article-title":"A Novel RF-Powered Wireless Pacing via a Rectenna-Based Pacemaker and a Wearable Transmit-Antenna Array","volume":"7","author":"Asif","year":"2019","journal-title":"IEEE Access"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"2100614","DOI":"10.1002\/adhm.202100614","article-title":"Wireless Power Transfer and Telemetry for Implantable Bioelectronics","volume":"10","author":"Yoo","year":"2021","journal-title":"Adv. Healthc. Mater."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"48","DOI":"10.1109\/TBCAS.2010.2072782","article-title":"Design and Optimization of Resonance-Based Efficient Wireless Power Delivery Systems for Biomedical Implants","volume":"5","author":"RamRakhyani","year":"2011","journal-title":"IEEE Trans. Biomed. Circuits Syst."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"775","DOI":"10.1109\/TBME.2016.2576469","article-title":"Cavity Resonator Wireless Power Transfer System for Freely Moving Animal Experiments","volume":"64","author":"Mei","year":"2017","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"11775","DOI":"10.1109\/ACCESS.2019.2891815","article-title":"Performance Analysis of MICS-Based RF Wireless Power Transfer System for Implantable Medical Devices","volume":"7","author":"Abdulfattah","year":"2019","journal-title":"IEEE Access"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1038\/s41746-017-0009-x","article-title":"Highly flexible, wearable, and disposable cardiac biosensors for remote and ambulatory monitoring","volume":"1","author":"Lee","year":"2018","journal-title":"npj Digit. Med."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"eabb1093","DOI":"10.1126\/sciadv.abb1093","article-title":"Wirelessly controlled, bioresorbable drug delivery device with active valves that exploit electrochemically triggered crevice corrosion","volume":"6","author":"Koo","year":"2020","journal-title":"Sci. Adv."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"25100","DOI":"10.1021\/acs.langmuir.5c01350","article-title":"Wireless Power-Up and Readout of Label-Free Nanosensors for In-Vivo Monitoring of Protein Concentrations in Live Animals","volume":"41","author":"Raji","year":"2025","journal-title":"Langmuir"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1021\/acsabm.0c00798","article-title":"Wearable Sensing Devices for Point of Care Diagnostics","volume":"4","author":"Mondal","year":"2020","journal-title":"ACS Appl. Bio Mater."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"1506","DOI":"10.1021\/acssensors.5c03838","article-title":"Wearable Nanosensor for Noninvasive Multimodal Monitoring of Theophylline Pharmacokinetics and Hemodynamics","volume":"11","author":"Wang","year":"2026","journal-title":"ACS Sens."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"66","DOI":"10.1109\/MEMB.2005.1511502","article-title":"Implantable biomimetic microelectronic systems design","volume":"24","author":"Liu","year":"2005","journal-title":"IEEE Eng. Med. Biol. Mag."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"643","DOI":"10.1109\/TBCAS.2015.2466592","article-title":"A Single-Chip Full-Duplex High Speed Transceiver for Multi-Site Stimulating and Recording Neural Implants","volume":"10","author":"Mirbozorgi","year":"2016","journal-title":"IEEE Trans. Biomed. Circuits Syst."},{"key":"ref_15","doi-asserted-by":"crossref","unstructured":"Gong, C., Liu, D., Miao, Z., and Li, M. (2017). A Magnetic-Balanced Inductive Link for the Simultaneous Uplink Data and Power Telemetry. Sensors, 17.","DOI":"10.3390\/s17081768"},{"key":"ref_16","unstructured":"Atluri, S., and Ghovanloo, M. (2005, January 16\u201319). Design of a Wideband Power-Efficient Inductive Wireless Link for Implantable Biomedical Devices Using Multiple Carriers. Proceedings of the 2nd International IEEE EMBS Conference on Neural Engineering, Arlington, VA, USA."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"200","DOI":"10.1109\/TAP.2022.3222695","article-title":"Multi-Channel Implantable Cubic Rectenna MIMO System with CP Diversity in Orthogonal Space for Enhanced Wireless Power Transfer in Biotelemetry","volume":"71","author":"Kaim","year":"2023","journal-title":"IEEE Trans. Antennas Propag."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"4545","DOI":"10.1021\/nn401246y","article-title":"In Vivo Silicon-Based Flexible Radio Frequency Integrated Circuits Monolithically Encapsulated with Biocompatible Liquid Crystal Polymers","volume":"7","author":"Hwang","year":"2013","journal-title":"ACS Nano"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"1749","DOI":"10.1109\/JSSC.2020.2991524","article-title":"A Single-Chip Bidirectional Neural Interface with High-Voltage Stimulation and Adaptive Artifact Cancellation in Standard CMOS","volume":"55","author":"Uehlin","year":"2020","journal-title":"IEEE J. Solid-State Circuits"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"64","DOI":"10.1109\/TBCAS.2016.2580513","article-title":"An Integrated Passive Phase-Shift Keying Modulator for Biomedical Implants with Power Telemetry over a Single Inductive Link","volume":"11","author":"Jiang","year":"2017","journal-title":"IEEE Trans. Biomed. Circuits Syst."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"978","DOI":"10.1109\/JSSC.2014.2387832","article-title":"A 13.56 MHz Wireless Power Transfer System with Reconfigurable Resonant Regulating Rectifier and Wireless Power Control for Implantable Medical Devices","volume":"50","author":"Li","year":"2015","journal-title":"IEEE J. Solid-State Circuits"},{"key":"ref_22","first-page":"260","article-title":"An RFID-Based Closed-Loop Wireless Power Transmission System for Biomedical Applications","volume":"57","author":"Kiani","year":"2010","journal-title":"IEEE Trans. Circuits Syst. II Express Briefs"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"72","DOI":"10.1109\/RBME.2018.2873817","article-title":"Maximizing Data Transmission Rate for Implantable Devices over a Single Inductive Link: Methodological Review","volume":"12","author":"Trigui","year":"2019","journal-title":"IEEE Rev. Biomed. Eng."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"7145","DOI":"10.1109\/JSEN.2021.3049918","article-title":"Wireless Power and Data Transmission for Implanted Devices via Inductive Links: A Systematic Review","volume":"21","author":"Karimi","year":"2021","journal-title":"IEEE Sens. J."},{"key":"ref_25","first-page":"4","article-title":"A review of wireless power and data transfer systems for biomedical implants","volume":"3","author":"Hong","year":"2026","journal-title":"Neuroelectronics"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1109\/TBCAS.2007.893180","article-title":"Feedback Analysis and Design of RF Power Links for Low-Power Bionic Systems","volume":"1","author":"Baker","year":"2007","journal-title":"IEEE Trans. Biomed. Circuits Syst."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"544","DOI":"10.1109\/TIE.2010.2046002","article-title":"Analysis, Experimental Results, and Range Adaptation of Magnetically Coupled Resonators for Wireless Power Transfer","volume":"58","author":"Sample","year":"2011","journal-title":"IEEE Trans. Ind. Electron."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"1595","DOI":"10.1016\/j.mejo.2014.08.001","article-title":"Single frequency wireless power transfer and full-duplex communication system for intracranial epilepsy monitoring","volume":"45","author":"Yilmaz","year":"2014","journal-title":"Microelectron. J."},{"key":"ref_29","doi-asserted-by":"crossref","unstructured":"Garcer\u00e1n-Hern\u00e1ndez, V., and Mart\u00ednez-Rams, E.A. (2013). Cochlear Implant: Transcutaneous Transmission Link with OFDM. Natural and Artificial Models in Computation and Biology, Springer.","DOI":"10.1007\/978-3-642-38637-4_37"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1109\/MCAS.2005.1405898","article-title":"Wireless smart implants dedicated to multichannel monitoring and microstimulation","volume":"5","author":"Sawan","year":"2005","journal-title":"IEEE Circuits Syst. Mag."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"1386","DOI":"10.1109\/JSSC.2019.2943871","article-title":"A Wireless Power and Data Transfer Receiver Achieving 75.4% Effective Power Conversion Efficiency and Supporting 0.1% Modulation Depth for ASK Demodulation","volume":"55","author":"Ye","year":"2020","journal-title":"IEEE J. Solid-State Circuits"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"2552","DOI":"10.1109\/TCSI.2005.858163","article-title":"A fully integrated low-power BPSK demodulator for implantable medical devices","volume":"52","author":"Hu","year":"2005","journal-title":"IEEE Trans. Circuits Syst. I Regul. Pap."},{"key":"ref_33","unstructured":"Ghovanloo, M., and Najafi, K. (2003, January 25\u201328). A high-rate frequency shift keying demodulator chip for wireless biomedical implants. Proceedings of the 2003 International Symposium on Circuits and Systems, 2003. ISCAS \u201903, Bangkok, Thailand."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"438","DOI":"10.1109\/TPEL.2018.2822722","article-title":"Performance Evaluation of Series-Compensated IPT Systems for Transcutaneous Energy Transfer","volume":"34","author":"Knecht","year":"2019","journal-title":"IEEE Trans. Power Electron."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"493","DOI":"10.1007\/s12596-024-01929-4","article-title":"Investigations on modified OOK and adaptive threshold for wavelength division multiplexing free-space optical systems impaired by interchannel crosstalk, atmospheric turbulence, and ASE noise","volume":"55","author":"Elsayed","year":"2024","journal-title":"J. Opt."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"159379","DOI":"10.1109\/ACCESS.2019.2950622","article-title":"Energy Efficient Generic Demodulator for High Data Transmission Rate over an Inductive Link for Implantable Devices","volume":"7","author":"Trigui","year":"2019","journal-title":"IEEE Access"},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"5513","DOI":"10.1109\/TPEL.2018.2868727","article-title":"Resonant Analysis of Magnetic Coupling Wireless Power Transfer Systems","volume":"34","author":"Liao","year":"2019","journal-title":"IEEE Trans. Power Electron."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"3973","DOI":"10.1109\/TIE.2018.2851953","article-title":"Design Guidelines to Avoid Bifurcation in a Series\u2013Series Compensated Inductive Power Transfer System","volume":"66","author":"Aditya","year":"2019","journal-title":"IEEE Trans. Ind. Electron."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"2602","DOI":"10.1109\/TIE.2012.2196902","article-title":"Effect of Coupling Between Multiple Transmitters or Multiple Receivers on Wireless Power Transfer","volume":"60","author":"Ahn","year":"2013","journal-title":"IEEE Trans. Ind. Electron."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"350","DOI":"10.1109\/TIE.2011.2177611","article-title":"Contactless Energy Transfer Systems Using Antiparallel Resonant Loops","volume":"60","author":"Lee","year":"2013","journal-title":"IEEE Trans. Ind. Electron."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"6097","DOI":"10.1109\/TPEL.2014.2387835","article-title":"A Method of Using Nonidentical Resonant Coils for Frequency Splitting Elimination in Wireless Power Transfer","volume":"30","author":"Lyu","year":"2015","journal-title":"IEEE Trans. Power Electron."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"889","DOI":"10.1109\/TAP.2013.2290795","article-title":"Wireless Power Transfer System Adaptive to Change in Coil Separation","volume":"62","author":"Lee","year":"2014","journal-title":"IEEE Trans. Antennas Propag."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"6233","DOI":"10.1109\/TIE.2015.2420041","article-title":"Range-Adaptive Wireless Power Transfer Using Multiloop and Tunable Matching Techniques","volume":"62","author":"Kim","year":"2015","journal-title":"IEEE Trans. Ind. Electron."},{"key":"ref_44","doi-asserted-by":"crossref","unstructured":"Dang, Z., and Abu Qahouq, J.A. (2015, January 11). Extended-range two-coil adaptively reconfigurable wireless power transfer system. Proceedings of the 2015 IEEE Applied Power Electronics Conference and Exposition (APEC), Charlotte, NC, USA.","DOI":"10.1109\/APEC.2015.7104566"},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"5340","DOI":"10.1109\/TMTT.2019.2938753","article-title":"A Real-Time Range-Adaptive Impedance Matching Utilizing a Machine Learning Strategy Based on Neural Networks for Wireless Power Transfer Systems","volume":"67","author":"Jeong","year":"2019","journal-title":"IEEE Trans. Microw. Theory Tech."},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"10924","DOI":"10.1109\/TPEL.2018.2806402","article-title":"A Dynamic Tuning Method Utilizing Inductor Paralleled with Load for Inductive Power Transfer","volume":"33","author":"Mai","year":"2018","journal-title":"IEEE Trans. Power Electron."},{"key":"ref_47","doi-asserted-by":"crossref","unstructured":"Ullah, N., Barakat, A., Kanaya, H., and Pokharel, R.K. (2025). Wideband ASK-OOK Data Recovery Circuit for Data Transmission in Over-Coupled Mode of SWPDT System. Electronics, 14.","DOI":"10.3390\/electronics14020355"},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"1281","DOI":"10.1002\/cta.70051","article-title":"A Comparator-Less ASK-OOK Data Demodulator Circuit for Downlink Data Transfer over Inductive Link","volume":"54","author":"Ullah","year":"2025","journal-title":"Int. J. Circuit Theory Appl."},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"1","DOI":"10.3390\/electronics2010001","article-title":"Implantable Devices: Issues and Challenges","volume":"2","author":"Bazaka","year":"2012","journal-title":"Electronics"},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"301","DOI":"10.1109\/TBCAS.2008.2005295","article-title":"Power-Efficient Impedance-Modulation Wireless Data Links for Biomedical Implants","volume":"2","author":"Mandal","year":"2008","journal-title":"IEEE Trans. Biomed. Circuits Syst."},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1109\/TBCAS.2014.2304956","article-title":"A 13.56-Mbps Pulse Delay Modulation Based Transceiver for Simultaneous Near-Field Data and Power Transmission","volume":"9","author":"Kiani","year":"2015","journal-title":"IEEE Trans. Biomed. Circuits Syst."},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1088\/0967-3334\/26\/1\/008","article-title":"An implantable bi-directional wireless transmission system for transcutaneous biological signal recording","volume":"26","author":"Liang","year":"2005","journal-title":"Physiol. Meas."},{"key":"ref_53","doi-asserted-by":"crossref","unstructured":"Puers, R., and Thon\u00e9, J. (2010). Short Distance Wireless Communications. Bio-Medical CMOS ICs, Springer.","DOI":"10.1007\/978-1-4419-6597-4_7"},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"6078","DOI":"10.1109\/TPEL.2015.2399417","article-title":"Inductive Power Transfer System with Self-Calibrated Primary Resonant Frequency","volume":"30","author":"Trigui","year":"2015","journal-title":"IEEE Trans. Power Electron."},{"key":"ref_55","doi-asserted-by":"crossref","unstructured":"Troyk, P.R., and Cogan, S.F. (2005). Sensory Neural Prostheses. Neural Engineering, Springer.","DOI":"10.1007\/0-306-48610-5_1"},{"key":"ref_56","first-page":"1420","article-title":"A 1.5-pJ\/bit, 9.04-Mbit\/s Carrier-Width Demodulator for Data Transmission over an Inductive Link Supporting Power and Data Transfer","volume":"65","author":"Trigui","year":"2018","journal-title":"IEEE Trans. Circuits Syst. II Express Briefs"},{"key":"ref_57","doi-asserted-by":"crossref","unstructured":"Trigui, A., Ali, M., Ammari, A.C., Savaria, Y., and Sawan, M. (2016, January 24). Quad-Level Carrier Width Modulation demodulator for micro-implants. Proceedings of the 2016 14th IEEE International New Circuits and Systems Conference (NEWCAS), Vancouver, BC, Canada.","DOI":"10.1109\/NEWCAS.2016.7604801"},{"key":"ref_58","doi-asserted-by":"crossref","first-page":"100128","DOI":"10.1016\/j.memori.2025.100128","article-title":"Counter-based CMOS QCWM demodulator for wide frequency range WPT biohealth applications","volume":"10","author":"Zulkalnain","year":"2025","journal-title":"Mem.-Mater. Devices Circuits Syst."},{"key":"ref_59","doi-asserted-by":"crossref","unstructured":"Khanna, V.K. (2016). Wireless Communications and Powering of Implants. Implantable Medical Electronics, Springer.","DOI":"10.1007\/978-3-319-25448-7_10"},{"key":"ref_60","doi-asserted-by":"crossref","first-page":"184","DOI":"10.1109\/TBCAS.2008.924444","article-title":"Active High Power Conversion Efficiency Rectifier with Built-In Dual-Mode Back Telemetry in Standard CMOS Technology","volume":"2","author":"Bawa","year":"2008","journal-title":"IEEE Trans. Biomed. Circuits Syst."},{"key":"ref_61","doi-asserted-by":"crossref","first-page":"2664","DOI":"10.1109\/JSSC.2016.2600864","article-title":"Energy Recycling Telemetry IC with Simultaneous 11.5 mW Power and 6.78 Mb\/s Backward Data Delivery over a Single 13.56 MHz Inductive Link","volume":"51","author":"Ha","year":"2016","journal-title":"IEEE J. Solid-State Circuits"},{"key":"ref_62","doi-asserted-by":"crossref","unstructured":"Gong, C., Liu, D., Miao, Z., Wang, W., and Li, M. (2017). An NFC on Two-Coil WPT Link for Implantable Biomedical Sensors under Ultra-Weak Coupling. Sensors, 17.","DOI":"10.3390\/s17061358"},{"key":"ref_63","unstructured":"Hu, Y., Gervais, J.-F., and Sawan, M. (2002, January 15\u201318). High power efficiency inductive link with full-duplex data communication. Proceedings of the 9th International Conference on Electronics, Circuits and Systems, Dubrovnik, Croatia."},{"key":"ref_64","first-page":"714","article-title":"Fully Digital BPSK Demodulator and Multilevel LSK Back Telemetry for Biomedical Implant Transceivers","volume":"56","author":"Xu","year":"2009","journal-title":"IEEE Trans. Circuits Syst. II Express Briefs"},{"key":"ref_65","doi-asserted-by":"crossref","first-page":"221","DOI":"10.1016\/j.sna.2004.02.016","article-title":"An inductive power system with integrated bi-directional data-transmission","volume":"115","author":"Catrysse","year":"2004","journal-title":"Sens. Actuators A Phys."},{"key":"ref_66","doi-asserted-by":"crossref","first-page":"767","DOI":"10.1109\/TBCAS.2024.3483950","article-title":"A Reconfigurable Bidirectional Wireless Power and Full-Duplex Data Transceiver IC for Wearable Biomedical Applications","volume":"19","author":"Lee","year":"2025","journal-title":"IEEE Trans. Biomed. Circuits Syst."},{"key":"ref_67","doi-asserted-by":"crossref","first-page":"192","DOI":"10.1109\/TBCAS.2009.2039212","article-title":"High-Speed OQPSK and Efficient Power Transfer Through Inductive Link for Biomedical Implants","volume":"4","author":"Simard","year":"2010","journal-title":"IEEE Trans. Biomed. Circuits Syst."},{"key":"ref_68","first-page":"2793","article-title":"Rail-to-Rail-Input Dual-Radio 64-Channel Closed-Loop Neurostimulator","volume":"52","author":"Kassiri","year":"2017","journal-title":"IEEE J. Solid-State Circuits"},{"key":"ref_69","first-page":"382","article-title":"A 20-Mb\/s Pulse Harmonic Modulation Transceiver for Wideband Near-Field Data Transmission","volume":"60","author":"Kiani","year":"2013","journal-title":"IEEE Trans. Circuits Syst. II Express Briefs"},{"key":"ref_70","doi-asserted-by":"crossref","first-page":"1296","DOI":"10.1109\/JSSC.2011.2134570","article-title":"A 10.2 Mbps Pulse Harmonic Modulation Based Transceiver for Implantable Medical Devices","volume":"46","author":"Inanlou","year":"2011","journal-title":"IEEE J. Solid-State Circuits"},{"key":"ref_71","doi-asserted-by":"crossref","first-page":"2591","DOI":"10.1109\/JSSC.2009.2023159","article-title":"An Implantable 64-Channel Wireless Microsystem for Single-Unit Neural Recording","volume":"44","author":"Sodagar","year":"2009","journal-title":"IEEE J. Solid-State Circuits"},{"key":"ref_72","doi-asserted-by":"crossref","first-page":"359","DOI":"10.1007\/s10470-016-0705-5","article-title":"Remotely powered PPM demodulator by inductive coupling for rodent applications","volume":"88","author":"Ture","year":"2016","journal-title":"Analog. Integr. Circuits Signal Process."},{"key":"ref_73","unstructured":"Troyk, P.R., and Edgington, M. (2000, January 16\u201321). Inductive links and drivers for remotely-powered telemetry systems. Proceedings of the IEEE Antennas and Propagation Society International Symposium. Transmitting Waves of Progress to the Next Millennium. 2000 Digest. Held in Conjunction with: USNC\/URSI National Radio Science Meeting (Cat. No.00CH37118), Salt Lake City, UT, USA."},{"key":"ref_74","doi-asserted-by":"crossref","unstructured":"Gong, C.-S.A., Yao, K.-W., Shiue, M.-T., Lin, P.-Y., and Huang, C.-N. (2008, January 16\u201318). A Miniaturized PSK Demodulation Device for Short-Range Wireless Neural Prosthetic Systems. Proceedings of the 2008 2nd International Conference on Bioinformatics and Biomedical Engineering, Shanghai, China.","DOI":"10.1109\/ICBBE.2008.720"},{"key":"ref_75","doi-asserted-by":"crossref","first-page":"374","DOI":"10.1109\/TBCAS.2024.3427396","article-title":"A Power-Efficient Envelope-Detector-Less Amplitude-Shift-Keying Forward Telemetry for Wirelessly Powered Biomedical Devices","volume":"19","author":"Lee","year":"2025","journal-title":"IEEE Trans. Biomed. Circuits Syst."},{"key":"ref_76","doi-asserted-by":"crossref","unstructured":"Park, Y., Hung, P.D., Youn, D., Kwon, D., Kim, C., and Je, M. (2025, January 16\u201320). An Enhanced-Frequency-Splitting-Based Wireless Power and Data Transfer System Achieving 60.2% End-to-End Efficiency and 1 Mb\/s Data Rate with a Sub-cm RX Coil for Miniaturized Implants. Proceedings of the 2025 IEEE International Solid-State Circuits Conference (ISSCC), San Francisco, CA, USA.","DOI":"10.1109\/ISSCC49661.2025.10904522"},{"key":"ref_77","doi-asserted-by":"crossref","first-page":"108","DOI":"10.1109\/TBCAS.2022.3146559","article-title":"An Energy-Efficient ASK Demodulator Robust to Power-Carrier-Interference for Inductive Power and Data Telemetry","volume":"16","author":"Chen","year":"2022","journal-title":"IEEE Trans. Biomed. Circuits Syst."},{"key":"ref_78","first-page":"641","article-title":"Differentiating ASK Demodulator for Contactless Smart Cards Supporting VHBR","volume":"62","author":"Lee","year":"2015","journal-title":"IEEE Trans. Circuits Syst. II Express Briefs"},{"key":"ref_79","doi-asserted-by":"crossref","first-page":"502","DOI":"10.1049\/el.2015.4267","article-title":"184 \u03bcW ultrasonic on\u2013off keying\/amplitude-shift keying demodulator for downlink communication in deep implanted medical devices","volume":"52","author":"Mazzilli","year":"2016","journal-title":"Electron. Lett."},{"key":"ref_80","doi-asserted-by":"crossref","unstructured":"Navidi, M.M., and Byun, G.-S. (2013, January 7\u20139). A near-threshold ASK demodulator for ultra-low-power implantable biomedical microsystems. Proceedings of the WAMICON 2013, Orlando, FL, USA.","DOI":"10.1109\/WAMICON.2013.6572753"},{"key":"ref_81","doi-asserted-by":"crossref","first-page":"3966","DOI":"10.1109\/JSSC.2025.3611278","article-title":"A Wireless Power and Data Transfer System for Medical Implants Using a Miniaturized Inductive Link with Frequency-Splitting Enhancement","volume":"60","author":"Park","year":"2025","journal-title":"IEEE J. Solid-State Circuits"},{"key":"ref_82","doi-asserted-by":"crossref","first-page":"637","DOI":"10.1109\/TBCAS.2026.3670033","article-title":"A Dual-mode FSK Wireless Power and Data Transfer System with 1.1 Mbps Data Rate and Rectifier Output Power of 148 mW for Implantable Medical Applications","volume":"20","author":"Qian","year":"2026","journal-title":"IEEE Trans. Biomed. Circuits Syst."},{"key":"ref_83","doi-asserted-by":"crossref","first-page":"6298","DOI":"10.1002\/cta.4522","article-title":"Compact and Efficient FSK-CDR Design for Forward Data Transfer over Wireless Inductive Link","volume":"53","author":"Ullah","year":"2025","journal-title":"Int. J. Circuit Theory Appl."},{"key":"ref_84","first-page":"2954","article-title":"Distance Extension of S-PS Wireless Power Transfer System Based on Parity-Time Symmetry","volume":"70","author":"Qu","year":"2023","journal-title":"IEEE Trans. Circuits Syst. II Express Briefs"},{"key":"ref_85","doi-asserted-by":"crossref","unstructured":"Park, Y., Koh, S.-T., Lee, J., Kim, H., Choi, J., Ha, S., Kim, C., and Je, M. (2021, January 13\u201322). 33.7 A Frequency-Splitting-Based Wireless Power and Data Transfer IC for Neural Prostheses with Simultaneous 115mW Power and 2.5Mb\/s Forward Data Delivery. Proceedings of the 2021 IEEE International Solid-State Circuits Conference (ISSCC), San Francisco, CA, USA.","DOI":"10.1109\/ISSCC42613.2021.9365781"},{"key":"ref_86","doi-asserted-by":"crossref","first-page":"2109","DOI":"10.1109\/TCSI.2005.852923","article-title":"Design and analysis of an adaptive transcutaneous power telemetry for biomedical implants","volume":"52","author":"Wang","year":"2005","journal-title":"IEEE Trans. Circuits Syst. I Regul. Pap."},{"key":"ref_87","doi-asserted-by":"crossref","first-page":"98","DOI":"10.1109\/TBCAS.2015.2403282","article-title":"A Battery-Less, Implantable Neuro-Electronic Interface for Studying the Mechanisms of Deep Brain Stimulation in Rat Models","volume":"10","author":"Lin","year":"2016","journal-title":"IEEE Trans. Biomed. Circuits Syst."},{"key":"ref_88","doi-asserted-by":"crossref","first-page":"1749","DOI":"10.1109\/TCSI.2010.2103172","article-title":"An Integrated Power-Efficient Active Rectifier with Offset-Controlled High Speed Comparators for Inductively Powered Applications","volume":"58","author":"Lee","year":"2011","journal-title":"IEEE Trans. Circuits Syst. I Regul. Pap."},{"key":"ref_89","doi-asserted-by":"crossref","first-page":"2211","DOI":"10.1109\/TCSI.2007.905187","article-title":"A Wide-Band Power-Efficient Inductive Wireless Link for Implantable Microelectronic Devices Using Multiple Carriers","volume":"54","author":"Ghovanloo","year":"2007","journal-title":"IEEE Trans. Circuits Syst. I Regul. Pap."},{"key":"ref_90","doi-asserted-by":"crossref","unstructured":"Kilinc, E.G., Dehollain, C., and Maloberti, F. (2014, January 3\u20136). A low-power PPM demodulator for remotely powered batteryless implantable devices. Proceedings of the 2014 IEEE 57th International Midwest Symposium on Circuits and Systems (MWSCAS), College Station, TX, USA.","DOI":"10.1109\/MWSCAS.2014.6908416"},{"key":"ref_91","doi-asserted-by":"crossref","unstructured":"Ranjandish, R., Ture, K., Maloberti, F., Dehollain, C., and Schmid, A. (2018, January 3\u20136). All Wireless, 16-Channel Epilepsy Control System with Sub-\u00b5W\/Channel and Closed-Loop Stimulation Using a Switched-Capacitor-Based Active Charge Balancing Method. Proceedings of the ESSCIRC 2018\u2014IEEE 44th European Solid State Circuits Conference (ESSCIRC), Dresden, Germany.","DOI":"10.1109\/ESSCIRC.2018.8494252"},{"key":"ref_92","doi-asserted-by":"crossref","first-page":"497","DOI":"10.1109\/TBCAS.2017.2679441","article-title":"A Fully Integrated Wireless SoC for Motor Function Recovery After Spinal Cord Injury","volume":"11","author":"Lo","year":"2017","journal-title":"IEEE Trans. Biomed. Circuits Syst."},{"key":"ref_93","doi-asserted-by":"crossref","first-page":"3255","DOI":"10.1109\/TBME.2012.2214385","article-title":"A Power and Data Link for a Wireless-Implanted Neural Recording System","volume":"59","author":"Rush","year":"2012","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_94","doi-asserted-by":"crossref","unstructured":"Kao, C.-H., Lin, Y.-P., and Tang, K.-T. (2011, January 3\u20135). Wireless data and power transmission circuits in biomedical implantable applications. Proceedings of the International Symposium on Bioelectronics and Bioinformations, Suzhou, China.","DOI":"10.1109\/ISBB.2011.6107632"},{"key":"ref_95","doi-asserted-by":"crossref","unstructured":"Sonkusale, S., and Luo, Z. (2008, January 20\u201325). A complete data and power telemetry system utilizing BPSK and LSK signaling for biomedical implants. Proceedings of the 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Vancouver, BC, Canada.","DOI":"10.1109\/IEMBS.2008.4649888"},{"key":"ref_96","doi-asserted-by":"crossref","first-page":"123","DOI":"10.1109\/JSSC.2006.886567","article-title":"A Low-Power Integrated Circuit for a Wireless 100-Electrode Neural Recording System","volume":"42","author":"Harrison","year":"2007","journal-title":"IEEE J. Solid-State Circuits"},{"key":"ref_97","doi-asserted-by":"crossref","unstructured":"Lee, J., Kim, Y., Kim, D., Kang, D., Song, M., and Lee, B. (2025, January 8\u201312). A Wireless Power and Synchronized Full-Duplex Data Transceiver IC with 400 Kbps Bidirectional Data Rate Using a Single Inductive Link for Low-Power Systems. Proceedings of the 2025 Symposium on VLSI Technology and Circuits (VLSI Technology and Circuits), Kyoto, Japan.","DOI":"10.23919\/VLSITechnologyandCir65189.2025.11074871"},{"key":"ref_98","unstructured":"(1999). IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz (Standard No. IEEE Std C95.1, 1999 Edition)."}],"container-title":["Micromachines"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2072-666X\/17\/9\/998\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,24]],"date-time":"2026-08-24T17:22:04Z","timestamp":1787592124000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2072-666X\/17\/9\/998"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8,24]]},"references-count":98,"journal-issue":{"issue":"9","published-online":{"date-parts":[[2026,9]]}},"alternative-id":["mi17090998"],"URL":"https:\/\/doi.org\/10.3390\/mi17090998","relation":{},"ISSN":["2072-666X"],"issn-type":[{"value":"2072-666X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8,24]]}}}