{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T04:56:29Z","timestamp":1787028989478,"version":"build-2736575974"},"reference-count":43,"publisher":"MDPI AG","issue":"5","license":[{"start":{"date-parts":[[2022,5,19]],"date-time":"2022-05-19T00:00:00Z","timestamp":1652918400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"University of Rijeka \u201cAdaptation to the new EU Bathing Water Directive\u201d","award":["uniri-biomed-18-292"],"award-info":[{"award-number":["uniri-biomed-18-292"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Microorganisms"],"abstract":"<jats:p>Legionella colonization of water supply pipes is a significant public health problem. The objective of this work was to evaluate Legionella colonization in hotel hot water systems and to investigate the relationship between metal concentrations, piping materials (galvanized iron pipes and plastic pipes), and Legionella proliferation. Concentrations of calcium and magnesium ions and the presence of Legionella pneumophila were determined in a total of 108 water samples from the hot water systems of four hotels in Split-Dalmatia County over a 12-month period, and additional data on piping materials were collected. L. pneumophila was isolated in 23.1% of all samples\u2014in 28.8% (15\/52) of water samples from galvanized iron pipes and in 17.8% (10\/56) of samples from plastic pipes. L. pneumophila serogroups 2\u201314 were isolated from all samples. This study found higher prevalence of L. pneumophila at higher concentrations of Ca and Mg ions (except for Mg and plastic pipes). The metal parts of the water supply may be important factors in Legionella contamination due to the possibility of lime scale or roughness of the pipes. Higher Ca and Mg ion concentrations increased the risk of Legionella colonization.<\/jats:p>","DOI":"10.3390\/microorganisms10051051","type":"journal-article","created":{"date-parts":[[2022,5,20]],"date-time":"2022-05-20T00:18:11Z","timestamp":1653005891000},"page":"1051","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":11,"title":["Influence of Metal Concentration and Plumbing Materials on Legionella Contamination"],"prefix":"10.3390","volume":"10","author":[{"given":"Anita","family":"Raki\u0107","sequence":"first","affiliation":[{"name":"Public Health Institute of Split-Dalmatia County, Vukovarska 46, 21000 Split, Croatia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0534-2547","authenticated-orcid":false,"given":"Darija","family":"Vuki\u0107 Lu\u0161i\u0107","sequence":"additional","affiliation":[{"name":"Department of Environmental Health, Faculty of Medicine, University of Rijeka, Bra\u0107e Branchetta 20, 51000 Rijeka, Croatia"},{"name":"Department of Environmental Health, Teaching Institute of Public Health of Primorje-Gorski Kotar County, Kre\u0161imirova 52a, 51000 Rijeka, Croatia"},{"name":"Center for Advanced Computing and Modeling, University of Rijeka, Radmile Matej\u010di\u0107 2, 51000 Rijeka, Croatia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anamarija","family":"Jur\u010dev Savi\u010devi\u0107","sequence":"additional","affiliation":[{"name":"Public Health Institute of Split-Dalmatia County, Vukovarska 46, 21000 Split, Croatia"},{"name":"Department of Health Studies, University of Split, 35 P.P. 464, Ru\u0111era Bo\u0161kovi\u0107a Street, 21000 Split, Croatia"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2022,5,19]]},"reference":[{"key":"ref_1","first-page":"20417","article-title":"Legionnaires\u2019 disease in Europe, 2009\u20132010","volume":"18","author":"Zucs","year":"2013","journal-title":"Eurosurveillance"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"921","DOI":"10.1016\/j.watres.2011.12.022","article-title":"Legionellae in engineered systems and use of quantitative microbial risk assessment to predict exposure","volume":"46","author":"Buse","year":"2012","journal-title":"Water Res."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"7171","DOI":"10.1128\/AEM.00832-10","article-title":"Characterization of bacterial community structure in a drinking water distribution system during an occurrence of red water","volume":"76","author":"Li","year":"2010","journal-title":"Appl. Environ. Microbiol."},{"key":"ref_4","first-page":"109","article-title":"Hrvatske vode: \u010casopis za vodno gospodarstvo. Technical measures to prevent the propagation of bacteria Legionella spp. in hot water supply systems","volume":"24","author":"Ljoljo","year":"2016","journal-title":"Hrvat. Vode"},{"key":"ref_5","first-page":"1","article-title":"Overview of biofilm formation in distribution systems and its impact on the deterioration of water quality","volume":"26","author":"Momba","year":"2000","journal-title":"Water SA"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"3121","DOI":"10.1099\/00221287-147-11-3121","article-title":"Role of biofilms in the survival of Legionella pneumophila in a model potable-water system","volume":"147","author":"Murga","year":"2001","journal-title":"Microbiology"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"708","DOI":"10.2166\/wst.2011.696","article-title":"Chemical disinfection of Legionella in hot water systems biofilm: A pilot-scale 1 study","volume":"64","author":"Farhat","year":"2011","journal-title":"Water Sci. Technol."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1322","DOI":"10.1017\/S0950268814001964","article-title":"Community outbreak of legionellosis and an environmental investigation into a community water system","volume":"143","author":"Cohn","year":"2015","journal-title":"Epidemiol. Infect."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1016\/j.seppur.2011.05.008","article-title":"The influence of magnetic water treatment on CaCO3 scale formation in membrane distillation process","volume":"80","author":"Gryta","year":"2011","journal-title":"Sep. Purif. Technol."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"124","DOI":"10.1080\/15459624.2016.1229481","article-title":"Existence and control of Legionella bacteria in building water systems: A review","volume":"14","author":"Springston","year":"2017","journal-title":"J. Occup. Environ. Hyg."},{"key":"ref_11","doi-asserted-by":"crossref","unstructured":"Flemming, H.C. (2011). Biofilm Highlights, Springer.","DOI":"10.1007\/978-3-642-19940-0"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"4797","DOI":"10.1021\/acs.est.5b00142","article-title":"Confirmed and Potential Sources of Legionella Reviewed","volume":"49","author":"Schalk","year":"2015","journal-title":"Environ. Sci. Technol."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"2315","DOI":"10.1016\/j.watres.2011.01.009","article-title":"Parameters predictive of Legionella contamination in hot water systems: Association with trace elements and heterotrophic plate counts","volume":"45","author":"Bargellini","year":"2011","journal-title":"Water Res."},{"key":"ref_14","unstructured":"(2006). Water Quality\u2014Sampling for Microbiological Analysis (Standard No. EN ISO 19458:2006)."},{"key":"ref_15","unstructured":"(2004). Water Quality\u2014Detection and Enumeration of Legionella\u2014Part 2: Direct Membrane Filtration Method for Waters with Low Bacterial Counts (Standard No. ISO 11731-2:2004)."},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"Arrigo, I., Galia, E., Fasciana, T., Diquattro, O., Tricoli, M.R., Serra, N., Palermo, M., and Giammanco, A. (2022). Four-Year Environmental Surveillance Program of Legionella spp. in One of Palermo\u2019s Largest Hospitals. Microorganisms, 10.","DOI":"10.3390\/microorganisms10040764"},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Fasciana, T., Mascarella, C., Distefano, S.A., Cal\u00e0, C., Capra, G., Rampulla, A., Di Carlo, P., Palermo, M., and Giammanco, A. (2019). Cluster of Legionnaires\u2019 Disease in an Italian Prison. Int. J. Environ. Res. Public Health, 16.","DOI":"10.3390\/ijerph16112062"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"2104","DOI":"10.1111\/j.1365-2672.2008.03932.x","article-title":"Detection of culturable and nonculturable Legionella species from hot water systems of public buildings in Japan","volume":"105","author":"Edagawa","year":"2008","journal-title":"J. Appl. Microbiol."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"102269","DOI":"10.1016\/j.tmaid.2022.102269","article-title":"Determination of Legionella spp. prevalence in Spanish hotels in five years. Are tourists really at risk?","volume":"46","author":"Laso","year":"2022","journal-title":"Travel Med. Infect. Dis."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"623","DOI":"10.1016\/j.ajic.2007.01.002","article-title":"Thermal disinfection of hotels, hospitals, and athletic venues hot water distribution systems contaminated by Legionella species","volume":"35","author":"Mouchtouri","year":"2007","journal-title":"Am. J. Infect. Control"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"855","DOI":"10.2166\/wh.2021.175","article-title":"Environmental surveillance of Legionella pneumophila in hot water systems of hotels in Morocco","volume":"19","author":"Assaidi","year":"2021","journal-title":"J. Water Health"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"457","DOI":"10.3201\/eid1003.020707","article-title":"Legionella infection risk from domestic hot water","volume":"10","author":"Borella","year":"2004","journal-title":"Emerg. Infect. Dis."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"5614","DOI":"10.1016\/j.watres.2013.06.034","article-title":"Seasonal dynamics of bacterial community structure and composition in cold and hot drinking water derived from surface water reservoirs","volume":"47","author":"Henne","year":"2013","journal-title":"Water Res."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"6104","DOI":"10.1007\/s11356-014-3819-2","article-title":"Seasonal variation of Legionella in Taiwan\u2019s reservoir and its relationships with environmental factors","volume":"22","author":"Kao","year":"2014","journal-title":"Environ. Sci. Pollut. Res."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"8851","DOI":"10.1021\/es302042t","article-title":"Bacterial community structure in the drinking water microbiome is governed by filtration processes","volume":"46","author":"Pinto","year":"2012","journal-title":"Environ. Sci. Technol."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"143","DOI":"10.1089\/ees.2017.0115","article-title":"A 21st-Century Perspective on Calcium Carbonate Formation in Potable Water Systems","volume":"35","author":"Richards","year":"2017","journal-title":"Environ. Eng. Sci."},{"key":"ref_27","doi-asserted-by":"crossref","unstructured":"Martin, R.L., Harrison, K., Proctor, C.R., Martin, A., Williams, K., Pruden, A., and Edwards, M.A. (2020). Chlorine Disinfection of Legionella spp., L. pneumophila, and Acanthamoeba under Warm Water Premise Plumbing Conditions. Microorganisms, 8.","DOI":"10.3390\/microorganisms8091452"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"373","DOI":"10.1111\/j.1365-2672.2004.02458.x","article-title":"Legionella waterline colonization: Detection of Legionella species in domestic, hotel and hospital hot water systems","volume":"98","author":"Leoni","year":"2005","journal-title":"J. Appl. Microbiol."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"1149","DOI":"10.1128\/aem.50.5.1149-1154.1985","article-title":"Effects of metals on Legionella pneumophila growth in drinking water plumbing systems","volume":"50","author":"States","year":"1985","journal-title":"Appl. Environ. Microbiol."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"437","DOI":"10.1007\/s00284-012-0295-0","article-title":"Involvement of minerals in adherence of Legionella pneumophila to surfaces","volume":"66","author":"Koubar","year":"2013","journal-title":"Curr. Microbiol."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"125","DOI":"10.3389\/fcimb.2014.00125","article-title":"Metabolism of the vacuolar pathogen Legionella and implications for virulence","volume":"4","author":"Manske","year":"2014","journal-title":"Front. Cell. Infect. Microbiol."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"1471","DOI":"10.1080\/01694243.2018.1423664","article-title":"Effect of temperature and plumbing materials on biofilm formation by Legionella pneumophila serogroup 1 and 2\u201315","volume":"32","author":"Assaidi","year":"2018","journal-title":"J. Adhes. Sci. Technol."},{"key":"ref_33","doi-asserted-by":"crossref","unstructured":"Ji, P., Parks, J., Edwards, M.A., and Pruden, A. (2015). Impact of Water Chemistry, Pipe Material and Stagnation on the Building Plumbing Microbiome. PLoS ONE, 10.","DOI":"10.1371\/journal.pone.0141087"},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"1571","DOI":"10.1038\/ismej.2011.41","article-title":"Transitions in bacterial communities along the 2000 km salinity gradient of the Baltic Sea","volume":"5","author":"Herlemann","year":"2011","journal-title":"ISME J."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"11436","DOI":"10.1073\/pnas.0611525104","article-title":"Global patterns in bacterial diversity","volume":"104","author":"Lozupone","year":"2007","journal-title":"Proc. Natl. Acad. Sci. USA"},{"key":"ref_36","doi-asserted-by":"crossref","unstructured":"Cullom, A.C., Martin, R.L., Song, Y., Williams, K., Williams, A., Pruden, A., and Edwards, M.A. (2020). Critical Review: Propensity of Premise Plumbing Pipe Materials to Enhance or Diminish Growth of Legionella and Other Opportunistic Pathogens. Pathogens, 9.","DOI":"10.3390\/pathogens9110957"},{"key":"ref_37","doi-asserted-by":"crossref","unstructured":"Pierre, D., Baron, J.L., Ma, X., Sidari, F.P., Wagener, M.M., and Stout, J.E. (2019). Water Quality as a Predictor of Legionella Positivity of Building Water Systems. Pathogens, 8.","DOI":"10.3390\/pathogens8040295"},{"key":"ref_38","first-page":"49","article-title":"Legionella pneumophila in residential water supplies: Environmental surveillance with clinical assessment for Legionnaires\u2019 disease","volume":"109","author":"Stout","year":"1992","journal-title":"Epidemiol. Infect."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"357","DOI":"10.1017\/S0195941700067412","article-title":"Determinants of Legionella pneumophila contamination of water distribution systems: 15-hospital prospective study","volume":"8","author":"Vickers","year":"1987","journal-title":"Infect. Control"},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"115","DOI":"10.4014\/jmb.1010.10012","article-title":"Effects of diverse water pipe materials on bacterial communities and water quality in the annular reactor","volume":"21","author":"Jang","year":"2011","journal-title":"J. Microbiol. Biotechnol."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"473","DOI":"10.4014\/mbl.1907.07007","article-title":"Multispecies Interactions in Biofilms and Implications to Safety of Drinking Water Distribution System","volume":"47","author":"Reuben","year":"2019","journal-title":"Microbiol. Biotechnol. Lett."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"344","DOI":"10.1016\/j.ajic.2009.09.016","article-title":"Effective environmental sampling strategies for monitoring Legionella spp. contamination in hot water systems","volume":"38","author":"Ditommaso","year":"2010","journal-title":"Am. J. Infect. Control"},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1016\/j.watres.2007.07.054","article-title":"Effect of pipe corrosion scales on chlorine dioxide consumption in drinking water distribution systems","volume":"42","author":"Zhang","year":"2008","journal-title":"Water Res."}],"container-title":["Microorganisms"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2076-2607\/10\/5\/1051\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T23:14:57Z","timestamp":1760138097000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2076-2607\/10\/5\/1051"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,5,19]]},"references-count":43,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2022,5]]}},"alternative-id":["microorganisms10051051"],"URL":"https:\/\/doi.org\/10.3390\/microorganisms10051051","relation":{},"ISSN":["2076-2607"],"issn-type":[{"value":"2076-2607","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,5,19]]}}}