{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,9]],"date-time":"2026-10-09T20:09:11Z","timestamp":1791576551995,"version":"4.3.4"},"reference-count":59,"publisher":"MDPI AG","issue":"13","license":[{"start":{"date-parts":[[2022,6,22]],"date-time":"2022-06-22T00:00:00Z","timestamp":1655856000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Molecules"],"abstract":"<jats:p>Poly(ethylene glycol) diacrylate (PEGDA) microgels with tuneable size and porosity find applications as extracellular matrix mimics for tissue-engineering scaffolds, biosensors, and drug carriers. Monodispersed PEGDA microgels were produced by modular droplet microfluidics using the dispersed phase with 49\u201399 wt% PEGDA, 1 wt% Darocur 2959, and 0\u201350 wt% water, while the continuous phase was 3.5 wt% silicone-based surfactant dissolved in silicone oil. Pure PEGDA droplets were fully cured within 60 s at the UV light intensity of 75 mW\/cm2. The droplets with higher water content required more time for curing. Due to oxygen inhibition, the polymerisation started in the droplet centre and advanced towards the edge, leading to a temporary solid core\/liquid shell morphology, confirmed by tracking the Brownian motion of fluorescent latex nanoparticles within a droplet. A volumetric shrinkage during polymerisation was 1\u20134% for pure PEGDA droplets and 20\u201332% for the droplets containing 10\u201340 wt% water. The particle volume increased by 36\u201350% after swelling in deionised water. The surface smoothness and sphericity of the particles decreased with increasing water content in the dispersed phase. The porosity of swollen particles was controlled from 29.7% to 41.6% by changing the water content in the dispersed phase from 10 wt% to 40 wt%.<\/jats:p>","DOI":"10.3390\/molecules27134013","type":"journal-article","created":{"date-parts":[[2022,6,22]],"date-time":"2022-06-22T23:11:19Z","timestamp":1655939479000},"page":"4013","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":26,"title":["Facile Microfluidic Fabrication of Biocompatible Hydrogel Microspheres in a Novel Microfluidic Device"],"prefix":"10.3390","volume":"27","author":[{"given":"Minjun","family":"Chen","sequence":"first","affiliation":[{"name":"Department of Chemical Engineering, Loughborough University, Loughborough LE11 3TU, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ruqaiya","family":"Aluunmani","sequence":"additional","affiliation":[{"name":"Department of Chemical Engineering, Loughborough University, Loughborough LE11 3TU, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2380-0794","authenticated-orcid":false,"given":"Guido","family":"Bolognesi","sequence":"additional","affiliation":[{"name":"Department of Chemical Engineering, Loughborough University, Loughborough LE11 3TU, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8894-975X","authenticated-orcid":false,"given":"Goran T.","family":"Vladisavljevi\u0107","sequence":"additional","affiliation":[{"name":"Department of Chemical Engineering, Loughborough University, Loughborough LE11 3TU, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2022,6,22]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1016\/j.jare.2013.07.006","article-title":"Hydrogel: Preparation, characterization, and applications: A review","volume":"6","author":"Ahmed","year":"2015","journal-title":"J. Adv. Res."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"252","DOI":"10.1016\/j.eurpolymj.2014.11.024","article-title":"Biomedical applications of hydrogels: A review of patents and commercial products","volume":"65","author":"Khutoryanskiy","year":"2015","journal-title":"Eur. Polym. J."},{"key":"ref_3","doi-asserted-by":"crossref","unstructured":"Bashir, S., Hina, M., Iqbal, J., Rajpar, A.H., Mujtaba, M.A., Alghamdi, N.A., Wageh, S., Ramesh, K., and Ramesh, S. (2020). Fundamental concepts of hydrogels: Synthesis, properties, and their applications. Polymers, 12.","DOI":"10.3390\/polym12112702"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"456","DOI":"10.1016\/j.ijbiomac.2008.08.010","article-title":"Chitosan\/polyethylene glycol diacrylate films as potential wound dressing material","volume":"43","author":"Zhang","year":"2008","journal-title":"Int. J. Biol. Macromol."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"40","DOI":"10.2144\/btn-2018-0083","article-title":"Recent advances in photo-crosslinkable hydrogels for biomedical applications","volume":"66","author":"Choi","year":"2019","journal-title":"BioTechniques"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"36","DOI":"10.1007\/s11095-017-2298-9","article-title":"Synthesis and characterisation of photocrosslinked poly (ethylene glycol) diacrylate implants for sustained ocular drug delivery","volume":"35","author":"McAvoy","year":"2018","journal-title":"Pharm. Res."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"444","DOI":"10.1089\/wound.2014.0614","article-title":"Chronic wound dressings based on collagen-mimetic proteins","volume":"4","author":"Cereceres","year":"2015","journal-title":"Adv. Wound Care"},{"key":"ref_8","first-page":"386","article-title":"Hydrogel microparticles for biosensing","volume":"72","author":"Srinivas","year":"2014","journal-title":"Eur. Polym. J."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"22362","DOI":"10.1007\/s11356-019-05557-5","article-title":"Hydrophobic-force-driven adsorption of bisphenol A from aqueous solution by polyethylene glycol diacrylate hydrogel microsphere","volume":"26","author":"Du","year":"2019","journal-title":"Environ. Sci. Pollut. Res. Int."},{"key":"ref_10","doi-asserted-by":"crossref","unstructured":"Papavasiliou, G., Sokic, S., and Turturro, M. (2012). Synthetic PEG hydrogels as extracellular matrix mimics for tissue engineering applications. Biotechnology\u2014Molecular Studies and Novel Applications for Improved Quality of Human Life, IntechOpen.","DOI":"10.5772\/31695"},{"key":"ref_11","doi-asserted-by":"crossref","unstructured":"Varghese, S., and Elisseeff, J.H. (2006). Hydrogels for musculoskeletal tissue engineering. Polymers for Regenerative Medicine, Springer.","DOI":"10.1007\/12_072"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"10096","DOI":"10.1021\/ja051977c","article-title":"Direct fabrication and harvesting of monodisperse, shape-specific nanobiomaterials","volume":"127","author":"Rolland","year":"2005","journal-title":"J. Am. Chem. Soc."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"9370","DOI":"10.1021\/ac302128u","article-title":"Multiplexed detection of mRNA using porosity-tuned hydrogel microparticles","volume":"84","author":"Choi","year":"2012","journal-title":"Anal. Chem."},{"key":"ref_14","first-page":"e54331","article-title":"Fabrication of inverted colloidal crystal poly (ethylene glycol) scaffold: A three-dimensional cell culture platform for liver tissue engineering","volume":"114","author":"Shirahama","year":"2016","journal-title":"J. Vis. Exp."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"844","DOI":"10.1021\/bm1011695","article-title":"Poly (ethylene glycol) microparticles produced by precipitation polymerization in aqueous solution","volume":"12","author":"Flake","year":"2011","journal-title":"Biomacromolecules"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"5391","DOI":"10.1016\/j.biomaterials.2006.06.005","article-title":"Micromolding of shape-controlled, harvestable cell-laden hydrogels","volume":"27","author":"Yeh","year":"2006","journal-title":"Biomaterials"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"5851","DOI":"10.1021\/ac101032r","article-title":"Fabrication of uniform DNA-conjugated hydrogel microparticles via replica molding for facile nucleic acid hybridization assays","volume":"82","author":"Lewis","year":"2010","journal-title":"Anal. Chem."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"258","DOI":"10.1002\/btm2.10070","article-title":"Peptide delivery with poly (ethylene glycol) diacrylate microneedles through swelling effect","volume":"2","author":"Liu","year":"2017","journal-title":"Bioeng. Transl. Med."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"31901","DOI":"10.1038\/srep31901","article-title":"Electrically controllable microparticle synthesis and digital microfluidic manipulation by electric-field-induced droplet dispensing into immiscible fluids","volume":"6","author":"Um","year":"2016","journal-title":"Sci. Rep."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"2006336","DOI":"10.1002\/adma.202006336","article-title":"Continuous high-throughput fabrication of architected micromaterials via in-air photopolymerization","volume":"33","author":"Jiang","year":"2021","journal-title":"Adv. Mater."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"591","DOI":"10.1039\/C6LC01023G","article-title":"Recent advances in engineering microparticles and their nascent utilization in biomedical delivery and diagnostic applications","volume":"17","author":"Choi","year":"2017","journal-title":"Lab Chip"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"365","DOI":"10.1038\/nmat1617","article-title":"Continuous-flow lithography for high-throughput microparticle synthesis","volume":"5","author":"Dendukuri","year":"2006","journal-title":"Nat. Mater."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"022006","DOI":"10.1063\/1.3694869","article-title":"Utilizing microfluidics to synthesize polyethylene glycol microbeads for F\u00f6rster resonance energy transfer based glucose sensing","volume":"6","author":"Kantak","year":"2012","journal-title":"Biomicrofluidics"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"333","DOI":"10.1007\/s10404-014-1436-5","article-title":"Microfluidic synthesis of monodisperse PEGDA microbeads for sustained release of 5-fluorouracil","volume":"18","author":"Xue","year":"2015","journal-title":"Microfluid. Nanofluid."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"1457","DOI":"10.1039\/C6LC00254D","article-title":"Monodisperse polyethylene glycol diacrylate hydrogel microsphere formation by oxygen-controlled photopolymerization in a microfluidic device","volume":"16","author":"Krutkramelis","year":"2016","journal-title":"Lab Chip"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"2216","DOI":"10.1021\/la4041198","article-title":"High throughput synthesis of uniform biocompatible polymer beads with high quantum dot loading using microfluidic jet-mode breakup","volume":"30","author":"Lee","year":"2014","journal-title":"Langmuir"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"482","DOI":"10.1039\/C5TB02209F","article-title":"Microfluidic synthesis of QD-encoded PEGDA microspheres for suspension assay","volume":"4","author":"Liu","year":"2016","journal-title":"J. Mater. Chem. B"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"537","DOI":"10.1126\/science.1109164","article-title":"Monodisperse double emulsions generated from a microcapillary device","volume":"308","author":"Utada","year":"2005","journal-title":"Science"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"39662","DOI":"10.1039\/D0RA07318K","article-title":"Injectable microfluidic hydrogel microspheres based on chitosan and poly (ethylene glycol) diacrylate (PEGDA) as chondrocyte carriers","volume":"10","author":"Lin","year":"2020","journal-title":"RSC Adv."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"125586","DOI":"10.1016\/j.colsurfa.2020.125586","article-title":"Coupling electrohydrodynamics with photopolymerization for microfluidics-based generation of polyethylene glycol diacrylate (PEGDA) microparticles and hydrogels","volume":"608","author":"Pullagura","year":"2021","journal-title":"Colloids Surf. A"},{"key":"ref_31","doi-asserted-by":"crossref","unstructured":"Xia, H., Li, A., Man, J., Li, J., and Li, J. (2021). Fabrication of multi-layered microspheres based on phase separation for drug delivery. Micromachines, 12.","DOI":"10.3390\/mi12060723"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"5646","DOI":"10.1039\/C7CS00263G","article-title":"Microfluidic fabrication of microparticles for biomedical applications","volume":"47","author":"Li","year":"2018","journal-title":"Chem. Soc. Rev."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"6544","DOI":"10.1021\/ac0346712","article-title":"Solvent compatibility of poly (dimethylsiloxane)-based microfluidic devices","volume":"75","author":"Lee","year":"2003","journal-title":"Anal. Chem."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"429","DOI":"10.2144\/05383RV02","article-title":"Disposable microfluidic devices: Fabrication, function, and application","volume":"38","author":"Fiorini","year":"2005","journal-title":"BioTechniques"},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"279","DOI":"10.1016\/j.jcis.2015.03.032","article-title":"Dynamics of double emulsion break-up in three phase glass capillary microfluidic devices","volume":"450","author":"Nabavi","year":"2015","journal-title":"J. Colloid Interface Sci."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"9034","DOI":"10.1021\/la1037102","article-title":"Mastering a double emulsion in a simple co-flow microfluidic to generate complex polymersomes","volume":"27","author":"Perro","year":"2011","journal-title":"Langmuir"},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1088\/0960-1317\/24\/1\/015019","article-title":"Simple and inexpensive microfluidic devices for the generation of monodisperse multiple emulsions","volume":"24","author":"Li","year":"2014","journal-title":"J. Micromech. Microeng."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"23","DOI":"10.1016\/j.jcis.2019.01.119","article-title":"Versatile reconfigurable glass capillary microfluidic devices with Lego\u00ae inspired blocks for drop generation and micromixing","volume":"542","author":"Bandulasena","year":"2019","journal-title":"J. Colloid Interface Sci."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"4178","DOI":"10.1039\/C4LC00992D","article-title":"A 3D-printed microcapillary assembly for facile double emulsion generation","volume":"14","author":"Martino","year":"2014","journal-title":"Lab Chip"},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"451","DOI":"10.1016\/j.jcis.2021.12.094","article-title":"Novel glass capillary microfluidic devices for the flexible and simple production of multi-cored double emulsions","volume":"611","author":"Leister","year":"2022","journal-title":"J. Colloid Interface Sci."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"1091","DOI":"10.1016\/S0161-6420(99)90261-0","article-title":"Chemical stability of silicone oil in the human eye after prolonged clinical use","volume":"106","author":"Lakits","year":"1999","journal-title":"Ophthalmology"},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"548","DOI":"10.1002\/jbm.10079","article-title":"Biocompatibility assessment of silicone oil and perfluorocarbon liquids used in retinal reattachment surgery in rat retinal cultures","volume":"60","author":"Morgillo","year":"2002","journal-title":"J. Biomed. Mater. Res."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"426","DOI":"10.1002\/adma.201001758","article-title":"Interfacial rheology through microfluidics","volume":"23","author":"Martin","year":"2011","journal-title":"Adv. Mat."},{"key":"ref_44","doi-asserted-by":"crossref","unstructured":"Loizou, K., Wong, V.L., and Hewakandamby, B. (2018). Examining the effect of flow rate ratio on droplet generation and regime transition in a microfluidic T-junction at constant capillary numbers. Inventions, 3.","DOI":"10.3390\/inventions3030054"},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"4163","DOI":"10.1103\/PhysRevLett.86.4163","article-title":"Dynamic pattern formation in a vesicle-generating microfluidic device","volume":"86","author":"Thorsen","year":"2001","journal-title":"Phys. Rev. Lett."},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"12948","DOI":"10.1021\/la302092f","article-title":"Emulsion templating of poly(lactic acid) particles: Droplet formation behavior","volume":"28","author":"Duncanson","year":"2012","journal-title":"Langmuir"},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"911","DOI":"10.1016\/j.dental.2006.06.034","article-title":"Shrinkage stress in light-cured composite resins: Influence of material and photoactivation mode","volume":"23","author":"Charton","year":"2007","journal-title":"Dent. Mater."},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"97","DOI":"10.1111\/j.1600-0722.1997.tb00188.x","article-title":"Resin composites in dentistry: The monomer systems","volume":"105","author":"Peutzfeldt","year":"1997","journal-title":"Eur. J. Oral Sci."},{"key":"ref_49","unstructured":"(2017). Technical Data Sheet, XIAMETER\u2122 PMX-200 Silicone Fluid, 50\u20131000 cSt, The Dow Chemical Company."},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"4081","DOI":"10.1002\/adma.201501603","article-title":"Step-index optical fiber made of biocompatible hydrogels","volume":"27","author":"Choi","year":"2015","journal-title":"Adv Mater."},{"key":"ref_51","doi-asserted-by":"crossref","unstructured":"Torres-Mapa, M.L., Singh, M., Simon, O., Mapa, J.L., Machida, M., G\u00fcnther, A., Roth, B., Heinemann, D., Terakawa, M., and Heisterkamp, A. (2019). Fabrication of a monolithic lab-on-a-chip platform with integrated hydrogel waveguides for chemical sensing. Sensors, 19.","DOI":"10.3390\/s19194333"},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"593","DOI":"10.1016\/0079-6700(95)00027-5","article-title":"Photoinitiated crosslinking polymerisation","volume":"21","author":"Decker","year":"1996","journal-title":"Prog. Polym. Sci."},{"key":"ref_53","doi-asserted-by":"crossref","unstructured":"Park, J.W., Shim, G.S., Lee, J.G., Jang, S.W., Kim, H.J., and Choi, J.N. (2018). Evaluation of UV curing properties of mixture systems with differently sized monomers. Materials, 11.","DOI":"10.3390\/ma11040509"},{"key":"ref_54","doi-asserted-by":"crossref","unstructured":"Acosta-Cuevas, J.M., Gonz\u00e1lez-Garc\u00eda, J., Garc\u00eda-Ram\u00edrez, M., P\u00e9rez-Luna, V.H., Cisneros-L\u00f3pez, E.O., Gonz\u00e1lez-Nu\u00f1ez, R., and Gonz\u00e1lez-Reynoso, O. (2021). Generation of photopolymerized microparticles based on PEGDA using microfluidic devices. part 1. initial gelation time and mechanical properties of the material. Micromachines, 12.","DOI":"10.3390\/mi12030293"},{"key":"ref_55","doi-asserted-by":"crossref","first-page":"eabe3245","DOI":"10.1126\/sciadv.abe3245","article-title":"Precise control of synthetic hydrogel network structure via linear, independent synthesis-swelling relationships","volume":"7","author":"Richbourg","year":"2021","journal-title":"Sci. Adv."},{"key":"ref_56","doi-asserted-by":"crossref","first-page":"334","DOI":"10.1016\/j.jcis.2017.09.081","article-title":"Interfacially-mediated oxygen inhibition for precise and continuous poly (ethylene glycol) diacrylate (PEGDA) particle fabrication","volume":"510","author":"Debroy","year":"2018","journal-title":"J. Colloid Interface Sci."},{"key":"ref_57","doi-asserted-by":"crossref","first-page":"1287","DOI":"10.1016\/S0142-9612(98)00025-8","article-title":"Characterization of permeability and network structure of interfacially photopolymerized poly(ethylene glycol) diacrylate hydrogels","volume":"19","author":"Cruise","year":"1998","journal-title":"Biomaterials"},{"key":"ref_58","doi-asserted-by":"crossref","unstructured":"Marx, P., and Wiesbrock, F. (2021). Expanding monomers as anti-shrinkage additives. Polymers, 13.","DOI":"10.3390\/polym13050806"},{"key":"ref_59","doi-asserted-by":"crossref","first-page":"30","DOI":"10.1016\/j.jmbbm.2018.09.017","article-title":"Effect of water concentration on the shock response of polyethylene glycol diacrylate (PEGDA) hydrogels: A molecular dynamics study","volume":"90","author":"Luo","year":"2019","journal-title":"J. Mech. Behav. Biomed. Mater."}],"container-title":["Molecules"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1420-3049\/27\/13\/4013\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T23:37:31Z","timestamp":1760139451000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1420-3049\/27\/13\/4013"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,6,22]]},"references-count":59,"journal-issue":{"issue":"13","published-online":{"date-parts":[[2022,7]]}},"alternative-id":["molecules27134013"],"URL":"https:\/\/doi.org\/10.3390\/molecules27134013","relation":{},"ISSN":["1420-3049"],"issn-type":[{"value":"1420-3049","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,6,22]]}}}