{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,4]],"date-time":"2026-05-04T13:17:46Z","timestamp":1777900666218,"version":"3.51.4"},"reference-count":31,"publisher":"MDPI AG","issue":"2","license":[{"start":{"date-parts":[[2023,1,4]],"date-time":"2023-01-04T00:00:00Z","timestamp":1672790400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100004329","name":"Slovenian Research Agency","doi-asserted-by":"publisher","award":["P1-0153"],"award-info":[{"award-number":["P1-0153"]}],"id":[{"id":"10.13039\/501100004329","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Molecules"],"abstract":"<jats:p>Citrate anticoagulant concentration affects the results of coagulation tests. Until now, the end user had no direct insight into the quality of evacuated blood collection tubes. By introducing an easy-to-perform UV spectrometric method for citrate determination on a purified water model, we enabled the evaluation of (1) the accuracy of the anticoagulant amount added into the tubes by a producer, (2) the accuracy of the volume of anticoagulant solution in the tube at the instant of examination, (3) the anticoagulant concentrations at a draw volume. We examined the Vacuette\u00ae, Greiner BIO-ONE, Vacutube, LT Burnik d.o.o., and BD Vacutainer\u00ae tubes. The anticoagulant amount added into the tubes during production had a relative bias between 3.2 and 23.0%. The anticoagulant volume deficiency at the instant of examination expressed as a relative bias ranged between \u221211.6 and \u221291.1%. The anticoagulant concentration relative bias after the addition of purified water in a volume that equalled a nominal draw volume extended from 9.3 to 25.7%. Draw-volume was mostly compliant during shelf life. Only Vacutube lost water over time. Contamination with potassium, magnesium, or both was observed in all the tubes but did not exceed a 0.21 mmol\/L level. This study enables medical laboratories to gain insight into the characteristics of the citrate blood collection tubes as one of the preanalytical variables. In situations that require anticoagulant adjustment for accurate results, this can help make the right decisions. The methodology gives producers additional means of controlling the quality of their production process.<\/jats:p>","DOI":"10.3390\/molecules28020486","type":"journal-article","created":{"date-parts":[[2023,1,4]],"date-time":"2023-01-04T05:31:44Z","timestamp":1672810304000},"page":"486","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Accuracy of Citrate Anticoagulant Amount, Volume, and Concentration in Evacuated Blood Collection Tubes Evaluated with UV Molecular Absorption Spectrometry on a Purified Water Model"],"prefix":"10.3390","volume":"28","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8316-8017","authenticated-orcid":false,"given":"Nata\u0161a","family":"Gros","sequence":"first","affiliation":[{"name":"Faculty of Chemistry and Chemical Technology, University of Ljubljana, Ve\u010dna Pot 113, SI1000 Ljubljana, Slovenia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tadej","family":"Klobu\u010dar","sequence":"additional","affiliation":[{"name":"Faculty of Chemistry and Chemical Technology, University of Ljubljana, Ve\u010dna Pot 113, SI1000 Ljubljana, Slovenia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Klara","family":"Gaber","sequence":"additional","affiliation":[{"name":"Faculty of Chemistry and Chemical Technology, University of Ljubljana, Ve\u010dna Pot 113, SI1000 Ljubljana, Slovenia"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2023,1,4]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"433","DOI":"10.1055\/s-0039-1692700","article-title":"Preanalytical Variables in Coagulation Testing: Setting the Stage for Accurate Results","volume":"45","author":"Gosselin","year":"2019","journal-title":"Semin. Thromb. Hemost."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"1321","DOI":"10.1016\/j.clinbiochem.2016.10.004","article-title":"Blood collection tubes as medical devices: The potential to affect assays and proposed verification and validation processes for the clinical laboratory","volume":"49","author":"Bowen","year":"2016","journal-title":"Clin. Biochem."},{"key":"ref_3","unstructured":"CLSI (2010). Validation and Verification of Tubes for Venous and Capillary Blood Specimen Collection, CLSI. Approved Guideline; CLSI document GP34-A."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"2857","DOI":"10.1111\/jth.15514","article-title":"Guidance on the critical shortage of sodium citrate coagulation tubes for hemostasis testing","volume":"19","author":"Gosselin","year":"2021","journal-title":"J. Thromb. Haemost."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"319","DOI":"10.1515\/CCLM.2005.055","article-title":"Preanalytical variability in laboratory testing: Influence of the blood drawing technique","volume":"43","author":"Lippi","year":"2005","journal-title":"Clin. Chem. Lab. Med."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"31","DOI":"10.11613\/BM.2014.006","article-title":"Interferences from blood collection tube components on clinical chemistry assays","volume":"24","author":"Bowen","year":"2014","journal-title":"Biochem. Med."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"304","DOI":"10.1309\/JCQE33NBYGE0FFQR","article-title":"The evolution of evacuated blood collection tubes","volume":"34","author":"Bush","year":"2003","journal-title":"Lab. Med."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"843","DOI":"10.1309\/7V2KP1HP9Q29BMN2","article-title":"Comparison of samples obtained from 3.2% sodium citrate glass and two 3.2% sodium citrate plastic blood collection tubes used in coagulation testing","volume":"122","author":"Gosselin","year":"2004","journal-title":"Am. J. Clin. Pathol."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"732","DOI":"10.1309\/BMQHCD6B8984RLA3","article-title":"A comparison of blood collection in glass versus plastic vacutainers on results of esoteric coagulation assays","volume":"34","author":"Flanders","year":"2003","journal-title":"Lab. Med."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"664","DOI":"10.1055\/s-0037-1614084","article-title":"A comparison of two sodium citrate concentrations in two evacuated blood collection systems for prothrombin time and ISI determination","volume":"84","author":"Chantarangkul","year":"2000","journal-title":"Thromb. Haemost."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"367","DOI":"10.5505\/tjh.2012.59254","article-title":"Influence of Blood Collection Systems on Coagulation Tests","volume":"29","author":"Yavas","year":"2012","journal-title":"Turk. J. Hematol."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1016\/S0049-3848(02)00383-3","article-title":"How to evaluate the influence of blood collection systems on the international sensitivity index. Protocol applied to two new evacuated tubes and eight coagulometer\/thromboplastin combinations","volume":"108","author":"Tripodi","year":"2002","journal-title":"Thromb. Res."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1080\/09537104.2017.1327655","article-title":"Effects of pH and concentration of sodium citrate anticoagulant on platelet aggregation measured by light transmission aggregometry induced by adenosine diphosphate","volume":"29","author":"Germanovich","year":"2018","journal-title":"Platelets"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"614","DOI":"10.1111\/ijlh.12099","article-title":"Validation of the minimal citrate tube fill volume for routine coagulation tests on ACL TOP 500 CTS (R)","volume":"35","author":"Elst","year":"2013","journal-title":"Int. J. Lab. Hematol."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"84","DOI":"10.1055\/s-0038-1648816","article-title":"Effect of concentration of trisodium citrate anticoagulant on calculation of the international normalized ratio and the international sensitivity index of thromboplastin","volume":"72","author":"Duncan","year":"1994","journal-title":"Thromb. Haemost."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"754","DOI":"10.1093\/ajcp\/109.6.754","article-title":"Prolonged prothrombin time and activated partial thromboplastin time due to underfilled specimen tubes with 109 mmol\/L (3.2%) citrate anticoagulant","volume":"109","author":"Reneke","year":"1998","journal-title":"Am. J. Clin. Pathol."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"400","DOI":"10.1309\/RRQKT2JEYV33D19D","article-title":"Effect on routine and special coagulation testing values of citrate anticoagulant adjustment in patients with high hematocrit values","volume":"126","author":"Marlar","year":"2006","journal-title":"Am. J. Clin. Pathol."},{"key":"ref_18","first-page":"19","article-title":"Thrombin generation in different commercial sodium citrate blood tubes","volume":"39","author":"Salvagno","year":"2020","journal-title":"J. Med. Biochem."},{"key":"ref_19","unstructured":"CLSI (2010). Tubes and Additives for Venous and Capillary Blood Specimen Collection, CLSI. [6th ed.]. CLSI document GP39-A6."},{"key":"ref_20","unstructured":"NCCLS (2003). Tubes and Additives for Venous Blood Specimen Collection, NCCLS. [5th ed.]. NCCLS document H1-A5."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"1043","DOI":"10.1515\/cclm-2012-0507","article-title":"Evacuated blood-collection tubes for haematological tests-a quality evaluation prior to their intended use for specimen collection","volume":"51","author":"Gros","year":"2013","journal-title":"Clin. Chem. Lab. Med."},{"key":"ref_22","unstructured":"Varaprasad, B.E. (2018). Pre-Analytical Within-Laboratory Evacuated Blood-Collection Tube Quality Evaluation. Biochemical Testing: Clinical Correlation and Diagnosis, IntechOpen."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"137","DOI":"10.1016\/S0003-2670(03)00194-6","article-title":"Effect of citrate impurities on the reference pH value of potassium dihydrogen buffer solution","volume":"482","author":"Lito","year":"2003","journal-title":"Anal. Chim. Acta"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"1274","DOI":"10.1021\/ja01172a039","article-title":"Resolution of the dissociation constants of citric acid at 0-degrees to 50-degrees, and determination of certain related thermodynamic functions","volume":"71","author":"Bates","year":"1949","journal-title":"J. Am. Chem. Soc."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"717","DOI":"10.1016\/j.jfda.2017.01.009","article-title":"Convenient UV-spectrophotometric determination of citrates in aqueous solutions with applications in the pharmaceutical analysis of oral electrolyte formulations","volume":"25","author":"Krukowski","year":"2017","journal-title":"J. Food Drug Anal."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"276","DOI":"10.1080\/00365513.2019.1609696","article-title":"Filling accuracy and imprecision of commercial evacuated sodium citrate coagulation tubes","volume":"79","author":"Lippi","year":"2019","journal-title":"Scand. J. Clin. Lab. Investig."},{"key":"ref_27","first-page":"484","article-title":"Hybrid Blood Collection Tubes: Combining the Best Attributes of Glass and Plastic for Safety and Shelf life","volume":"25","author":"Weikart","year":"2020","journal-title":"SLAS Technol. Transl. Life Sci. Innov."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"403","DOI":"10.1111\/ijlh.12301","article-title":"Sodium citrate blood contamination by K-2-ethylenediaminetetraacetic acid (EDTA): Impact on routine coagulation testing","volume":"37","author":"Salvagno","year":"2015","journal-title":"Int. J. Lab. Hematol."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"647","DOI":"10.1055\/s-0037-1615647","article-title":"Prothrombin time ratio is reduced by magnesium contamination in evacuated blood collection tubes","volume":"85","author":"Sturk","year":"2001","journal-title":"Thromb. Haemost."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"248","DOI":"10.1309\/AJCPGSB5YPJRREEV","article-title":"Comparative Study of Blood Collection Tubes and Thromboplastin Reagents for Correction of INR Discrepancies A Proposal for Maximum Allowable Magnesium Contamination in Sodium Citrate Anticoagulant Solutions","volume":"138","author":"Brantjes","year":"2012","journal-title":"Am. J. Clin. Pathol."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1016\/j.thromres.2014.04.016","article-title":"A comparative study of conventional versus new, magnesium-poor Vacutainer (R) Sodium Citrate blood collection tubes for determination of prothrombin time and INR","volume":"134","author":"Berendes","year":"2014","journal-title":"Thromb. Res."}],"container-title":["Molecules"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1420-3049\/28\/2\/486\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T17:58:44Z","timestamp":1760119124000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1420-3049\/28\/2\/486"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,1,4]]},"references-count":31,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2023,1]]}},"alternative-id":["molecules28020486"],"URL":"https:\/\/doi.org\/10.3390\/molecules28020486","relation":{},"ISSN":["1420-3049"],"issn-type":[{"value":"1420-3049","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,1,4]]}}}