{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,22]],"date-time":"2026-03-22T02:46:22Z","timestamp":1774147582535,"version":"3.50.1"},"reference-count":76,"publisher":"MDPI AG","issue":"23","license":[{"start":{"date-parts":[[2022,11,23]],"date-time":"2022-11-23T00:00:00Z","timestamp":1669161600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Nanomaterials"],"abstract":"<jats:p>It has been proven that viral infections pose a serious hazard to humans and also affect social health, including morbidity and mental suffering, as illustrated by the COVID-19 pandemic. The early detection and isolation of virally infected people are, thus, required to control the spread of viruses. Due to the outstanding and unparalleled properties of nanomaterials, numerous biosensors were developed for the early detection of viral diseases via sensitive, minimally invasive, and simple procedures. To that aim, viral detection technologies based on carbon nanotubes (CNTs) are being developed as viable alternatives to existing diagnostic approaches. This article summarizes the advancements in CNT-based biosensors since the last decade in the detection of different human viruses, namely, SARS-CoV-2, dengue, influenza, human immunodeficiency virus (HIV), and hepatitis. Finally, the shortcomings and benefits of CNT-based biosensors for the detection of viruses are outlined and discussed.<\/jats:p>","DOI":"10.3390\/nano12234132","type":"journal-article","created":{"date-parts":[[2022,11,23]],"date-time":"2022-11-23T03:15:24Z","timestamp":1669173324000},"page":"4132","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":13,"title":["Decadal Journey of CNT-Based Analytical Biosensing Platforms in the Detection of Human Viruses"],"prefix":"10.3390","volume":"12","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-7402-7917","authenticated-orcid":false,"given":"Joydip","family":"Sengupta","sequence":"first","affiliation":[{"name":"Department of Electronic Science, Jogesh Chandra Chaudhuri College, Kolkata 700033, India"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1964-4338","authenticated-orcid":false,"given":"Chaudhery Mustansar","family":"Hussain","sequence":"additional","affiliation":[{"name":"Department of Chemistry and Environmental Science, New Jersey Institute of Technology, Newark, NJ 07102, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2022,11,23]]},"reference":[{"key":"ref_1","first-page":"88","article-title":"The Structure of Carbon Produced by Thermal Decomposition of Carbon Monoxide on an Iron Catalyst","volume":"26","author":"Radushkevich","year":"1952","journal-title":"Russ. J. Phys. Chem."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1038\/354056a0","article-title":"Helical Microtubules of Graphitic Carbon","volume":"354","author":"Iijima","year":"1991","journal-title":"Nature"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"43704","DOI":"10.1039\/D0RA09438B","article-title":"Carbon Nanotubes: Functionalisation and Their Application in Chemical Sensors","volume":"10","author":"Demon","year":"2020","journal-title":"RSC Adv."},{"key":"ref_4","unstructured":"(2022, October 18). Chemistry (IUPAC), T.I.U. of P. and A. IUPAC-Biosensor (B00663). Available online: https:\/\/goldbook.iupac.org\/terms\/view\/B00663."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1111\/j.1749-6632.1962.tb13623.x","article-title":"Electrode Systems for Continuous Monitoring in Cardiovascular Surgery","volume":"102","author":"Clark","year":"1962","journal-title":"Ann. N.Y. Acad. Sci."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1016\/0166-0934(90)90144-5","article-title":"Detection of Rubella Antibody Using an Optical Immunosensor","volume":"27","author":"Parry","year":"1990","journal-title":"J. Virol. Methods"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"261","DOI":"10.1016\/S0020-1693(97)05926-4","article-title":"The Immobilisation of Proteins in Carbon Nanotubes","volume":"272","author":"Davis","year":"1998","journal-title":"Inorg. Chim. Acta"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1912","DOI":"10.1002\/(SICI)1521-3773(19990712)38:13\/14<1912::AID-ANIE1912>3.0.CO;2-2","article-title":"Helical Crystallization of Proteins on Carbon Nanotubes: A First Step towards the Development of New Biosensors","volume":"38","author":"Balavoine","year":"1999","journal-title":"Angew. Chem. Int. Ed."},{"key":"ref_9","first-page":"59","article-title":"Carbon Nanotube Biosensors","volume":"3","author":"Morris","year":"2015","journal-title":"Front. Chem."},{"key":"ref_10","unstructured":"Awasthi, K. (2021). 23-Zinc Oxide Nanostructures\u2013Based Biosensors. Nanostructured Zinc Oxide, Elsevier. Metal Oxides."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"70","DOI":"10.1109\/TBME.1970.4502688","article-title":"Development of an Ion-Sensitive Solid-State Device for Neurophysiological Measurements","volume":"BME-17","author":"Bergveld","year":"1970","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_12","doi-asserted-by":"crossref","unstructured":"Zhang, Z., Cong, Y., Huang, Y., and Du, X. (2019). Nanomaterials-Based Electrochemical Immunosensors. Micromachines, 10.","DOI":"10.3390\/mi10060397"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"260","DOI":"10.3390\/electrochem1030017","article-title":"Supported and Suspended 2D Material-Based FET Biosensors","volume":"1","author":"Masurkar","year":"2020","journal-title":"Electrochem"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"111693","DOI":"10.1016\/j.bios.2019.111693","article-title":"Optical Biosensors Based on Refractometric Sensing Schemes: A Review","volume":"144","author":"Chen","year":"2019","journal-title":"Biosens. Bioelectron."},{"key":"ref_15","unstructured":"Grumezescu, A.M. (2017). 5-Nanomaterial-Based Electrochemical Biosensors for Food Safety and Quality Assessment. Nanobiosensors, Academic Press."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"2272","DOI":"10.1021\/acs.nanolett.1c00118","article-title":"Rapid SARS-CoV-2 Spike Protein Detection by Carbon Nanotube-Based Near-Infrared Nanosensors","volume":"21","author":"Pinals","year":"2021","journal-title":"Nano Lett."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"10321","DOI":"10.1021\/acsami.0c22589","article-title":"Rapid Detection of SARS-CoV-2 Antigens Using High-Purity Semiconducting Single-Walled Carbon Nanotube-Based Field-Effect Transistors","volume":"13","author":"Shao","year":"2021","journal-title":"ACS Appl. Mater. Interfaces"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"107982","DOI":"10.1016\/j.bioelechem.2021.107982","article-title":"Carbon Nanotube Field-Effect Transistor (CNT-FET)-Based Biosensor for Rapid Detection of SARS-CoV-2 (COVID-19) Surface Spike Protein S1","volume":"143","author":"Zamzami","year":"2022","journal-title":"Bioelectrochemistry"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"2546","DOI":"10.1016\/j.matpr.2021.05.011","article-title":"Selective and Electronic Detection of COVID-19 (Coronavirus) Using Carbon Nanotube Field Effect Transistor-Based Biosensor: A Proof-of-Concept Study","volume":"49","author":"Thanihaichelvan","year":"2022","journal-title":"Mater. Today Proc."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"100354","DOI":"10.1016\/j.mtbio.2022.100354","article-title":"An Ultra-Sensitive Electrochemical Biosensor Using the Spike Protein for Capturing Antibodies against SARS-CoV-2 in Point-of-Care","volume":"16","author":"Cardoso","year":"2022","journal-title":"Mater. Today Bio"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"19204","DOI":"10.1021\/acsami.2c02405","article-title":"A Folding-Based Electrochemical Aptasensor for the Single-Step Detection of the SARS-CoV-2 Spike Protein","volume":"14","author":"Curti","year":"2022","journal-title":"ACS Appl. Mater. Interfaces"},{"key":"ref_22","doi-asserted-by":"crossref","unstructured":"Li, T., Soelberg, S.D., Taylor, Z., Sakthivelpathi, V., Furlong, C.E., Kim, J.-H., Ahn, S., Han, P.D., Starita, L.M., and Zhu, J. (2022). Highly Sensitive Immunoresistive Sensor for Point-Of-Care Screening for COVID-19. Biosensors, 12.","DOI":"10.3390\/bios12030149"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"2100111","DOI":"10.1002\/smsc.202100111","article-title":"Computational Method-Based Optimization of Carbon Nanotube Thin-Film Immunosensor for Rapid Detection of SARS-CoV-2 Virus","volume":"2","author":"Kim","year":"2022","journal-title":"Small Sci."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"216","DOI":"10.1016\/j.bios.2012.12.033","article-title":"A Sensor Tip Based on Carbon Nanotube-Ink Printed Electrode for the Dengue Virus NS1 Protein","volume":"44","author":"Dias","year":"2013","journal-title":"Biosens. Bioelectron."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"194","DOI":"10.1002\/jctb.4305","article-title":"Electrochemical Detection of Dengue Virus NS1 Protein with a Poly(Allylamine)\/Carbon Nanotube Layered Immunoelectrode","volume":"90","author":"Silva","year":"2015","journal-title":"J. Chem. Technol. Biotechnol."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"811","DOI":"10.1016\/j.bios.2017.01.017","article-title":"A Heparin-Functionalized Carbon Nanotube-Based Affinity Biosensor for Dengue Virus","volume":"91","author":"Wasik","year":"2017","journal-title":"Biosens. Bioelectron."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"679","DOI":"10.1021\/acs.analchem.7b03407","article-title":"Point-of-Use Nanobiosensor for Detection of Dengue Virus NS1 Antigen in Adult Aedes Aegypti: A Potential Tool for Improved Dengue Surveillance","volume":"90","author":"Wasik","year":"2018","journal-title":"Anal. Chem."},{"key":"ref_28","doi-asserted-by":"crossref","unstructured":"Wasik, D., Mulchandani, A., and Yates, M.V. (2018). Salivary Detection of Dengue Virus NS1 Protein with a Label-Free Immunosensor for Early Dengue Diagnosis. Sensors, 18.","DOI":"10.3390\/s18082641"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"84","DOI":"10.1016\/j.electacta.2018.04.099","article-title":"Impedimetric Quantification of Anti-Dengue Antibodies Using Functional Carbon Nanotube Deposits Validated with Blood Plasma Assays","volume":"274","author":"Palomar","year":"2018","journal-title":"Electrochim. Acta"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"363","DOI":"10.1007\/s00604-020-04339-y","article-title":"Voltammetric Sensing of Recombinant Viral Dengue Virus 2 NS1 Based on Au Nanoparticle\u2013Decorated Multiwalled Carbon Nanotube Composites","volume":"187","author":"Palomar","year":"2020","journal-title":"Microchim. Acta"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"4873","DOI":"10.1007\/s00216-021-03449-7","article-title":"NS1 Glycoprotein Detection in Serum and Urine as an Electrochemical Screening Immunosensor for Dengue and Zika Virus","volume":"413","author":"Santos","year":"2021","journal-title":"Anal. Bioanal. Chem."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"1543","DOI":"10.1016\/j.elecom.2009.05.055","article-title":"Label-Free Electrochemical Detection of Avian Influenza Virus Genotype Utilizing Multi-Walled Carbon Nanotubes\u2013Cobalt Phthalocyanine\u2013PAMAM Nanocomposite Modified Glassy Carbon Electrode","volume":"11","author":"Zhu","year":"2009","journal-title":"Electrochem. Commun."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"118","DOI":"10.1016\/j.jim.2009.08.002","article-title":"DNA Sensor Development Based on Multi-Wall Carbon Nanotubes for Label-Free Influenza Virus (Type A) Detection","volume":"350","author":"Tam","year":"2009","journal-title":"J. Immunol. Methods"},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"1765","DOI":"10.1039\/c000532k","article-title":"del Impedimetric Detection of Influenza A (H1N1) DNA Sequence Using Carbon Nanotubes Platform and Gold Nanoparticles Amplification","volume":"135","author":"Bonanni","year":"2010","journal-title":"Analyst"},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"3482","DOI":"10.1016\/j.bios.2011.01.029","article-title":"Carbon Nanotube Electric Immunoassay for the Detection of Swine Influenza Virus H1N1","volume":"26","author":"Lee","year":"2011","journal-title":"Biosens. Bioelectron."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"5415","DOI":"10.1039\/C4AN01335B","article-title":"Electrical Immunosensor Based on Dielectrophoretically-Deposited Carbon Nanotubes for Detection of Influenza Virus H1N1","volume":"139","author":"Singh","year":"2014","journal-title":"Analyst"},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"311","DOI":"10.1016\/j.bios.2014.09.021","article-title":"A Plasmon-Assisted Fluoro-Immunoassay Using Gold Nanoparticle-Decorated Carbon Nanotubes for Monitoring the Influenza Virus","volume":"64","author":"Lee","year":"2015","journal-title":"Biosens. Bioelectron."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"425","DOI":"10.1016\/j.bios.2017.11.052","article-title":"A Multi-Functional Gold\/Iron-Oxide Nanoparticle-CNT Hybrid Nanomaterial as Virus DNA Sensing Platform","volume":"102","author":"Lee","year":"2018","journal-title":"Biosens. Bioelectron."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"503","DOI":"10.1016\/j.bios.2016.05.050","article-title":"Enhanced Catalytic Activity of Gold Nanoparticle-Carbon Nanotube Hybrids for Influenza Virus Detection","volume":"85","author":"Ahmed","year":"2016","journal-title":"Biosens. Bioelectron."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"691","DOI":"10.1016\/j.snb.2017.04.080","article-title":"Chemiresistive Biosensors Based on Carbon Nanotubes for Label-Free Detection of DNA Sequences Derived from Avian Influenza Virus H5N1","volume":"249","author":"Fu","year":"2017","journal-title":"Sens. Actuators B Chem."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1016\/j.physe.2017.05.019","article-title":"Detection of Influenza A Virus Using Carbon Nanotubes Field Effect Transistor Based DNA Sensor","volume":"93","author":"Tran","year":"2017","journal-title":"Phys. E Low-Dimens. Syst. Nanostruct."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"8469","DOI":"10.2147\/IJN.S219976","article-title":"Aptamer-Antibody Complementation on Multiwalled Carbon Nanotube-Gold Transduced Dielectrode Surfaces to Detect Pandemic Swine Influenza Virus","volume":"14","author":"Wang","year":"2019","journal-title":"IJN"},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"2311","DOI":"10.1038\/s41598-022-06101-1","article-title":"Paper-Based Electrochemical Immunosensor for Label-Free Detection of Multiple Avian Influenza Virus Antigens Using Flexible Screen-Printed Carbon Nanotube-Polydimethylsiloxane Electrodes","volume":"12","author":"Lee","year":"2022","journal-title":"Sci. Rep."},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"7056","DOI":"10.1021\/ac801174r","article-title":"Impedance Method for Detecting HIV-1 Protease and Screening for Its Inhibitors Using Ferrocene-Peptide Conjugate\/Au Nanoparticle\/Single-Walled Carbon Nanotube Modified Electrode","volume":"80","author":"Mahmoud","year":"2008","journal-title":"Anal. Chem."},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"1680","DOI":"10.1080\/00032711003653924","article-title":"A Sensitive Electrochemical Assay for Early Detection of HIV-1 Protease Using Ferrocene-Peptide Conjugate\/Au Nanoparticle\/Single Walled Carbon Nanotube Modified Electrode","volume":"43","author":"Mahmoud","year":"2010","journal-title":"Anal. Lett."},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"4457","DOI":"10.1016\/j.bios.2011.05.002","article-title":"A Novel Amperometric Immunosensor Based on Acetone-Extracted Propolis for the Detection of the HIV-1 P24 Antigen","volume":"26","author":"Kheiri","year":"2011","journal-title":"Biosens. Bioelectron."},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1016\/j.talanta.2016.11.043","article-title":"A Multi-Walled Carbon Nanotubes Based Molecularly Imprinted Polymers Electrochemical Sensor for the Sensitive Determination of HIV-P24","volume":"164","author":"Ma","year":"2017","journal-title":"Talanta"},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"39970","DOI":"10.1039\/C7RA07245G","article-title":"Innovative Gold-Free Carbon Nanotube\/Chitosan-Based Competitive Immunosensor for Determination of HIV-Related P24 Capsid Protein in Serum","volume":"7","author":"Giannetto","year":"2017","journal-title":"RSC Adv."},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"1236","DOI":"10.1021\/acssensors.9b00025","article-title":"HIV Detection via a Carbon Nanotube RNA Sensor","volume":"4","author":"Harvey","year":"2019","journal-title":"ACS Sens."},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"113229","DOI":"10.1016\/j.bios.2021.113229","article-title":"Flexible Paper-Based Ni-MOF Composite\/AuNPs\/CNTs Film Electrode for HIV DNA Detection","volume":"184","author":"Lu","year":"2021","journal-title":"Biosens. Bioelectron."},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"321","DOI":"10.1089\/oli.2008.0143","article-title":"Label-Free Electrochemical Detection of Short Sequences Related to the Hepatitis B Virus Using 4,4\u2032-Diaminoazobenzene Based on Multiwalled Carbon Nanotube-Modified GCE","volume":"18","author":"Li","year":"2008","journal-title":"Oligonucleotides"},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"e229","DOI":"10.1016\/j.cap.2009.06.045","article-title":"Carbon Nanotube-Based Biosensor for Detection Hepatitis B","volume":"9","author":"Oh","year":"2009","journal-title":"Curr. Appl. Phys."},{"key":"ref_53","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1016\/j.jcv.2008.09.005","article-title":"Diagnosis of Human Hepatitis B Virus in Non-Treated Blood by the Bovine IgG DNA-Linked Carbon Nanotube Biosensor","volume":"44","author":"Ly","year":"2009","journal-title":"J. Clin. Virol."},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1016\/j.bioelechem.2011.01.005","article-title":"Facile Preparation of Carbon Nanotube-Conducting Polymer Network for Sensitive Electrochemical Immunoassay of Hepatitis B Surface Antigen in Serum","volume":"81","author":"Hu","year":"2011","journal-title":"Bioelectrochemistry"},{"key":"ref_55","doi-asserted-by":"crossref","first-page":"209","DOI":"10.1016\/j.talanta.2015.10.083","article-title":"A Label-Free Electrochemical Immunosensor for Hepatitis B Based on Hyaluronic Acid\u2013Carbon Nanotube Hybrid Film","volume":"148","author":"Cabral","year":"2016","journal-title":"Talanta"},{"key":"ref_56","doi-asserted-by":"crossref","first-page":"272","DOI":"10.1016\/j.colsurfb.2018.08.050","article-title":"A Label-Free and Reagentless Immunoelectrode for Antibodies against Hepatitis B Core Antigen (Anti-HBc) Detection","volume":"172","author":"Trindade","year":"2018","journal-title":"Colloids Surf. B Biointerfaces"},{"key":"ref_57","doi-asserted-by":"crossref","first-page":"930","DOI":"10.1166\/jbn.2019.2744","article-title":"Disposable Amperometric Immunosensor for Hepatitis B Antigen Detection Based on Multiwalled Carbon Nanotubes and Ferrocene Decorated Screen Printed Electrode","volume":"15","author":"Chen","year":"2019","journal-title":"J. Biomed. Nanotechnol."},{"key":"ref_58","doi-asserted-by":"crossref","first-page":"136335","DOI":"10.1016\/j.electacta.2020.136335","article-title":"Sequential Injection-Differential Pulse Voltammetric Immunosensor for Hepatitis B Surface Antigen Using the Modified Screen-Printed Carbon Electrode","volume":"349","author":"Upan","year":"2020","journal-title":"Electrochim. Acta"},{"key":"ref_59","doi-asserted-by":"crossref","first-page":"738","DOI":"10.1039\/b707025j","article-title":"Electrical Detection of Hepatitis C Virus RNA on Single Wall Carbon Nanotube-Field Effect Transistors","volume":"132","author":"Dastagir","year":"2007","journal-title":"Analyst"},{"key":"ref_60","doi-asserted-by":"crossref","first-page":"339","DOI":"10.1007\/s00604-022-05400-8","article-title":"Electrochemical Immunoassay for Detection of Hepatitis C Virus Core Antigen Using Electrode Modified with Pt-Decorated Single-Walled Carbon Nanotubes","volume":"189","author":"Pusomjit","year":"2022","journal-title":"Microchim. Acta"},{"key":"ref_61","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1016\/S1748-0132(07)70172-X","article-title":"Cell-Penetrating CNTs for Delivery of Therapeutics","volume":"2","author":"Lacerda","year":"2007","journal-title":"Nano Today"},{"key":"ref_62","doi-asserted-by":"crossref","first-page":"451","DOI":"10.2217\/fvl.11.21","article-title":"Virus Reactivation: A Panoramic View in Human Infections","volume":"6","author":"Traylen","year":"2011","journal-title":"Future Virol."},{"key":"ref_63","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1016\/j.virol.2018.07.011","article-title":"Strength in Diversity: Understanding the Pathways to Herpes Simplex Virus Reactivation","volume":"522","author":"Suzich","year":"2018","journal-title":"Virology"},{"key":"ref_64","doi-asserted-by":"crossref","first-page":"651","DOI":"10.1136\/jclinpath-2019-205822","article-title":"Epstein-Barr Virus (EBV) Reactivation and Therapeutic Inhibitors","volume":"72","author":"Kerr","year":"2019","journal-title":"J. Clin. Pathol."},{"key":"ref_65","doi-asserted-by":"crossref","first-page":"151","DOI":"10.1016\/j.antiviral.2011.03.179","article-title":"Cytomegalovirus Reactivation in Critically Ill Immunocompetent Hosts: A Decade of Progress and Remaining Challenges","volume":"90","author":"Cook","year":"2011","journal-title":"Antivir. Res."},{"key":"ref_66","doi-asserted-by":"crossref","first-page":"448","DOI":"10.1172\/JCI80565","article-title":"Molecular Mechanisms of HIV Latency","volume":"126","author":"Cary","year":"2016","journal-title":"J. Clin. Investig."},{"key":"ref_67","doi-asserted-by":"crossref","first-page":"116424","DOI":"10.1016\/j.trac.2021.116424","article-title":"Paper-Based Analytical Devices for Virus Detection: Recent Strategies for Current and Future Pandemics","volume":"144","author":"Ozer","year":"2021","journal-title":"TrAC Trends Anal. Chem."},{"key":"ref_68","doi-asserted-by":"crossref","unstructured":"Beduk, T., Beduk, D., Hasan, M.R., Guler Celik, E., Kosel, J., Narang, J., Salama, K.N., and Timur, S. (2022). Smartphone-Based Multiplexed Biosensing Tools for Health Monitoring. Biosensors, 12.","DOI":"10.3390\/bios12080583"},{"key":"ref_69","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1016\/j.tiv.2019.03.028","article-title":"Surface Defects Reduce Carbon Nanotube Toxicity in Vitro","volume":"60","author":"Requardt","year":"2019","journal-title":"Toxicol. Vitr."},{"key":"ref_70","doi-asserted-by":"crossref","first-page":"2815","DOI":"10.1038\/s41598-017-02770-5","article-title":"Curing the Toxicity of Multi-Walled Carbon Nanotubes through Native Small-Molecule Drugs","volume":"7","author":"Qi","year":"2017","journal-title":"Sci. Rep."},{"key":"ref_71","doi-asserted-by":"crossref","first-page":"394","DOI":"10.1539\/joh.17-0089-RA","article-title":"Review of Toxicity Studies of Carbon Nanotubes","volume":"59","author":"Kobayashi","year":"2017","journal-title":"J. Occup. Health"},{"key":"ref_72","doi-asserted-by":"crossref","first-page":"177","DOI":"10.1007\/s00604-022-05286-6","article-title":"Prospective Pathways of Green Graphene-Based Lab-on-Chip Devices: The Pursuit toward Sustainability","volume":"189","author":"Sengupta","year":"2022","journal-title":"Microchim. Acta"},{"key":"ref_73","unstructured":"(2022, November 03). SARS-CoV-2 Variants of Concern as of 27 October 2022, Available online: https:\/\/www.ecdc.europa.eu\/en\/covid-19\/variants-concern."},{"key":"ref_74","doi-asserted-by":"crossref","first-page":"25846","DOI":"10.1021\/acsomega.1c04024","article-title":"Multiplex Biosensing for Simultaneous Detection of Mutations in SARS-CoV-2","volume":"6","author":"Xi","year":"2021","journal-title":"ACS Omega"},{"key":"ref_75","doi-asserted-by":"crossref","first-page":"105101","DOI":"10.1088\/0957-4484\/23\/10\/105101","article-title":"Light-Activated Nanotube\u2013Porphyrin Conjugates as Effective Antiviral Agents","volume":"23","author":"Banerjee","year":"2012","journal-title":"Nanotechnology"},{"key":"ref_76","doi-asserted-by":"crossref","first-page":"548","DOI":"10.1016\/j.carbon.2014.11.007","article-title":"Synthesis and Anti-HIV Activity of Carboxylated and Drug-Conjugated Multi-Walled Carbon Nanotubes","volume":"82","author":"Iannazzo","year":"2015","journal-title":"Carbon"}],"container-title":["Nanomaterials"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2079-4991\/12\/23\/4132\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T01:24:48Z","timestamp":1760145888000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2079-4991\/12\/23\/4132"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,11,23]]},"references-count":76,"journal-issue":{"issue":"23","published-online":{"date-parts":[[2022,12]]}},"alternative-id":["nano12234132"],"URL":"https:\/\/doi.org\/10.3390\/nano12234132","relation":{},"ISSN":["2079-4991"],"issn-type":[{"value":"2079-4991","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,11,23]]}}}