{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,30]],"date-time":"2026-07-30T08:41:01Z","timestamp":1785400861109,"version":"3.56.0"},"reference-count":8,"publisher":"MDPI AG","issue":"7","license":[{"start":{"date-parts":[[2026,7,13]],"date-time":"2026-07-13T00:00:00Z","timestamp":1783900800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100007207","name":"Toray Industries, Inc.","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100007207","id-type":"DOI","asserted-by":"crossref"}]},{"id":[{"id":"https:\/\/ror.org\/029xh1r47","id-type":"ROR","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Neurology International"],"abstract":"<jats:p>Background\/Objectives: Detecting covert paroxysmal atrial fibrillation (AF) in patients with suspected embolic stroke of undetermined source (ESUS) is important for secondary prevention. This study evaluated the feasibility, AF detection, and wearability of the hitoe\u00ae wearable electrocardiogram (ECG) monitoring system II, a Holter-type device recording continuously for up to 14 days. Methods: Between March 2022 and October 2023, 31 patients with suspected ESUS were enrolled. After excluding two cases, 29 patients (mean age 74.7 \u00b1 17.3 years; 16 men) underwent ECG monitoring. Clinical outcomes were analyzed in 27 acute-phase patients and wearability in 24 questionnaire respondents. ECG recordings and questionnaire responses were analyzed descriptively, with between-group comparisons. Results: In 29 monitored patients, the mean recording duration was 12.4 \u00b1 3.7 days, the ECG acquisition rate was 64.0 \u00b1 23.4% (median 72.1%), and the mean analyzable duration was 8.1 \u00b1 3.7 days. In the 27 acute-phase patients, covert paroxysmal AF was detected in 2 patients (7.4%), on days 1, 3, and 15 in one patient and on day 7 in the other. In AF-positive patients, the mean ectopic burden was 1.33% for supraventricular and 0.24% for ventricular activity. Wearability was favorable: 77.8% reported no interference with daily activities, none reported sleep disturbance, and 72.7% adapted within 1\u20134 days. Conclusions: The hitoe\u00ae wearable ECG monitoring system II enabled prolonged monitoring across inpatient and outpatient settings, detecting covert paroxysmal AF in 7.4% of acute-phase patients with suspected ESUS. These findings support garment-type wearable ECG monitoring as a non-invasive option for extended rhythm surveillance.<\/jats:p>","DOI":"10.3390\/neurolint18070134","type":"journal-article","created":{"date-parts":[[2026,7,13]],"date-time":"2026-07-13T07:28:27Z","timestamp":1783927707000},"page":"134","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Utility and Wearability of the hitoe\u00ae Wearable ECG Monitoring System II for Detecting Covert Paroxysmal Atrial Fibrillation in Patients with Suspected ESUS Across Inpatient and Outpatient Settings: ACROSS-AF in ESUS"],"prefix":"10.3390","volume":"18","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4491-6064","authenticated-orcid":false,"given":"Hisanao","family":"Akiyama","sequence":"first","affiliation":[{"name":"Department of Neurology, St. Marianna University School of Medicine, 2-16-1 Sugao, Miyamae-ku, Kawasaki 216-8511, Kanagawa, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yasutaka","family":"Watanabe","sequence":"additional","affiliation":[{"name":"Department of Neurology, St. Marianna University School of Medicine, 2-16-1 Sugao, Miyamae-ku, Kawasaki 216-8511, Kanagawa, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takayuki","family":"Fukano","sequence":"additional","affiliation":[{"name":"Department of Neurology, St. Marianna University School of Medicine, 2-16-1 Sugao, Miyamae-ku, Kawasaki 216-8511, Kanagawa, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0516-412X","authenticated-orcid":false,"given":"Takahiro","family":"Shimizu","sequence":"additional","affiliation":[{"name":"Department of Neurology, St. Marianna University School of Medicine, 2-16-1 Sugao, Miyamae-ku, Kawasaki 216-8511, Kanagawa, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7527-0345","authenticated-orcid":false,"given":"Yoshihisa","family":"Yamano","sequence":"additional","affiliation":[{"name":"Department of Neurology, St. Marianna University School of Medicine, 2-16-1 Sugao, Miyamae-ku, Kawasaki 216-8511, Kanagawa, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2026,7,13]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"2478","DOI":"10.1056\/NEJMoa1313600","article-title":"Cryptogenic stroke and underlying atrial fibrillation","volume":"370","author":"Sanna","year":"2014","journal-title":"N. Engl. J. Med."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"2467","DOI":"10.1056\/NEJMoa1311376","article-title":"Atrial fibrillation in patients with cryptogenic stroke","volume":"370","author":"Gladstone","year":"2014","journal-title":"N. Engl. J. Med."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"158","DOI":"10.1159\/000369793","article-title":"Atrial fibrillation in young ischemic stroke patients: An underestimated cause?","volume":"73","author":"Hutyra","year":"2015","journal-title":"Eur. Neurol."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"544","DOI":"10.5551\/jat.58420","article-title":"Atrial fibrillation after ischemic stroke detected by chest strap-style 7-day Holter monitoring and the risk predictors: EDUCATE-ESUS","volume":"28","author":"Miyazaki","year":"2021","journal-title":"J. Atheroscler. Thromb."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1016\/j.ijcard.2017.10.063","article-title":"Yield of atrial fibrillation detection with textile wearable holter from the acute phase of stroke: Pilot study of Crypto-AF registry","volume":"251","author":"Pagola","year":"2018","journal-title":"Int. J. Cardiol."},{"key":"ref_6","doi-asserted-by":"crossref","unstructured":"Sgarra, L., Desantis, V., Matteucci, A., Caccavo, V.P., Troisi, F., Di Monaco, A., Mangini, F., Katsouras, G., Guaricci, A.I., and Dadamo, M.L. (2025). Non-Anticoagulation Strategies Aimed at Primary Stroke Prevention in Nascent Atrial Fibrillation. Biomedicines, 13.","DOI":"10.3390\/biomedicines13030660"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"915","DOI":"10.1111\/ejh.70155","article-title":"Oral Anticoagulation After Atrial Fibrillation Ablation: An Updated Systematic Review and Meta-Analysis of 267,443 Patients","volume":"116","author":"Matteucci","year":"2026","journal-title":"Eur. J. Haematol."},{"key":"ref_8","doi-asserted-by":"crossref","unstructured":"Machino, T., Aonuma, K., Maruo, K., Komatsu, Y., Yamasaki, H., Igarashi, M., Nogami, A., and Ieda, M. (2023). Randomized crossover trial of 2-week Garment electrocardiogram with dry textile electrode to reveal instances of post-ablation recurrence of atrial fibrillation underdiagnosed during 24-hour Holter monitoring. PLoS ONE, 18.","DOI":"10.1371\/journal.pone.0281818"}],"container-title":["Neurology International"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2035-8377\/18\/7\/134\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,15]],"date-time":"2026-07-15T04:19:01Z","timestamp":1784089141000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2035-8377\/18\/7\/134"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,13]]},"references-count":8,"journal-issue":{"issue":"7","published-online":{"date-parts":[[2026,7]]}},"alternative-id":["neurolint18070134"],"URL":"https:\/\/doi.org\/10.3390\/neurolint18070134","relation":{},"ISSN":["2035-8377"],"issn-type":[{"value":"2035-8377","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,13]]}}}