{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,29]],"date-time":"2026-07-29T14:15:24Z","timestamp":1785334524174,"version":"3.55.0"},"reference-count":35,"publisher":"MDPI AG","issue":"8","license":[{"start":{"date-parts":[[2026,7,29]],"date-time":"2026-07-29T00:00:00Z","timestamp":1785283200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Italian Ministry of Health with \u201cCurrent Research funds\u201d"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Pharmaceuticals"],"abstract":"<jats:p>Background: Volumetric absorptive microsampling (VAMS) is an emerging tool for therapeutic drug monitoring (TDM) of several drugs including antiseizure medications (ASMs). Here, we compared the concentrations of carbamazepine (CBZ), levetiracetam (LEV), lacosamide (LCS), topiramate (TPR) and the benzodiazepine (BZ) clobazam (CLB) in plasma and VAMS samples. Methods: VAMS samples were collected by fingerprick in pediatric patients followed at our center. Patients were also subjected to conventional venous blood sampling. Plasma and VAMS samples were analyzed by using a UHPLC-MS\/MS validated kit for AEs and BZs (ClinMass LC-MS\/MS Complete Kit\u00ae). A cross-validation analysis was performed by using Spearman correlation (rho), Deming regression and Bland\u2013Altman plots. Results: Two analytical methods for measuring selected AEs and BZs in VAMS samples were developed and validated in accordance with the ICH M10 guidelines. Based on Bland\u2013Altman results, a satisfactory agreement was observed between VAMS and plasma for CBZ, LCS, TPR, LEV and N-CLB. Considering the absence of interchangeability between capillary blood and plasma levels for CBZ-Diol, -Epoxi and CLB, a blood to plasma ratio was used to convert VAMS values into estimated plasma concentrations. Comparison of estimated vs. observed plasma results showed a successful predictive performance for this conversion approach. Conclusions: A positive agreement between plasma and VAMS was found for CBZ, LCS, TPR, LEV and N-CLB. Conversely, a conversion factor based on blood to plasma ratio should be adopted to convert CBZ-Diol, -Epoxi and CLB VAMS results into estimated plasma concentrations. This study confirmed the utility of VAMS for TDM of selected ASMs in pediatric patients during routine clinical practice.<\/jats:p>","DOI":"10.3390\/ph19081188","type":"journal-article","created":{"date-parts":[[2026,7,29]],"date-time":"2026-07-29T13:53:31Z","timestamp":1785333211000},"page":"1188","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Volumetric Absorptive Microsampling (VAMS) for Therapeutic Drug Monitoring of Antiseizure Medications (ASMs) in Pediatric Patients"],"prefix":"10.3390","volume":"19","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3989-7703","authenticated-orcid":false,"given":"Raffaele","family":"Simeoli","sequence":"first","affiliation":[{"name":"Division of Metabolic Diseases and Hepatology, Bambino Ges\u00f9 Children\u2019s Hospital, IRCCS, 00146 Rome, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1059-2292","authenticated-orcid":false,"given":"Alessandro","family":"Mancini","sequence":"additional","affiliation":[{"name":"Division of Metabolic Diseases and Hepatology, Bambino Ges\u00f9 Children\u2019s Hospital, IRCCS, 00146 Rome, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5925-0974","authenticated-orcid":false,"given":"Sara","family":"Cairoli","sequence":"additional","affiliation":[{"name":"Division of Metabolic Diseases and Hepatology, Bambino Ges\u00f9 Children\u2019s Hospital, IRCCS, 00146 Rome, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0007-5792-4393","authenticated-orcid":false,"given":"Chiara","family":"Rossi","sequence":"additional","affiliation":[{"name":"Division of Metabolic Diseases and Hepatology, Bambino Ges\u00f9 Children\u2019s Hospital, IRCCS, 00146 Rome, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Costanza","family":"Calabrese","sequence":"additional","affiliation":[{"name":"Neurology, Epilepsy, and Movement Disorders Unit, Full Member of European Reference Network EpiCARE, Bambino Ges\u00f9 Children\u2019s Hospital, IRCCS, 00146 Rome, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marina","family":"Trivisano","sequence":"additional","affiliation":[{"name":"Neurology, Epilepsy, and Movement Disorders Unit, Full Member of European Reference Network EpiCARE, Bambino Ges\u00f9 Children\u2019s Hospital, IRCCS, 00146 Rome, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Licia","family":"Salimbene","sequence":"additional","affiliation":[{"name":"Neurology, Epilepsy, and Movement Disorders Unit, Full Member of European Reference Network EpiCARE, Bambino Ges\u00f9 Children\u2019s Hospital, IRCCS, 00146 Rome, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0007-3379","authenticated-orcid":false,"given":"Carlo","family":"Dionisi Vici","sequence":"additional","affiliation":[{"name":"Division of Metabolic Diseases and Hepatology, Bambino Ges\u00f9 Children\u2019s Hospital, IRCCS, 00146 Rome, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2446-796X","authenticated-orcid":false,"given":"Nicola","family":"Pietrafusa","sequence":"additional","affiliation":[{"name":"Neurology, Epilepsy, and Movement Disorders Unit, Full Member of European Reference Network EpiCARE, Bambino Ges\u00f9 Children\u2019s Hospital, IRCCS, 00146 Rome, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8120-0287","authenticated-orcid":false,"given":"Nicola","family":"Specchio","sequence":"additional","affiliation":[{"name":"Neurology, Epilepsy, and Movement Disorders Unit, Full Member of European Reference Network EpiCARE, Bambino Ges\u00f9 Children\u2019s Hospital, IRCCS, 00146 Rome, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bianca Maria","family":"Goffredo","sequence":"additional","affiliation":[{"name":"Division of Metabolic Diseases and Hepatology, Bambino Ges\u00f9 Children\u2019s Hospital, IRCCS, 00146 Rome, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2026,7,29]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"296","DOI":"10.1212\/WNL.0000000000003509","article-title":"Prevalence and incidence of epilepsy: A systematic review and meta-analysis of international studies","volume":"88","author":"Fiest","year":"2017","journal-title":"Neurology"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"526","DOI":"10.1097\/FTD.0000000000000546","article-title":"Therapeutic Drug Monitoring of Antiepileptic Drugs in Epilepsy: A 2018 Update","volume":"40","author":"Patsalos","year":"2018","journal-title":"Ther. Drug Monit."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"723","DOI":"10.1016\/S1474-4422(23)00151-5","article-title":"Drug resistance in epilepsy","volume":"22","author":"Perucca","year":"2023","journal-title":"Lancet Neurol."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"1239","DOI":"10.1111\/j.1528-1167.2008.01561.x","article-title":"Antiepileptic drugs--best practice guidelines for therapeutic drug monitoring: A position paper by the subcommission on therapeutic drug monitoring, ILAE Commission on Therapeutic Strategies","volume":"49","author":"Patsalos","year":"2008","journal-title":"Epilepsia"},{"key":"ref_5","doi-asserted-by":"crossref","unstructured":"Simeoli, R., Dorlo, T.P.C., Hanff, L.M., Huitema, A.D.R., and Dreesen, E. (2022). Editorial: Therapeutic Drug Monitoring (TDM): A Useful Tool for Pediatric Pharmacology Applied to Routine Clinical Practice. Front. Pharmacol., 13.","DOI":"10.3389\/fphar.2022.931843"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"322","DOI":"10.1097\/FTD.0000000000000884","article-title":"Microsampling Devices for Routine Therapeutic Drug Monitoring-Are We There Yet?","volume":"43","author":"Morgan","year":"2021","journal-title":"Ther. Drug Monit."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"310","DOI":"10.1097\/FTD.0000000000000864","article-title":"Alternative Sampling Devices to Collect Dried Blood Microsamples: State-of-the-Art","volume":"43","author":"Delahaye","year":"2021","journal-title":"Ther. Drug Monit."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"e01199-18","DOI":"10.1128\/AAC.01199-18","article-title":"Validation of Heel Stick Microsampling To Optimize Micafungin Doses in Neonates and Young Infants","volume":"62","author":"Auriti","year":"2018","journal-title":"Antimicrob. Agents Chemother."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"653","DOI":"10.4155\/bio.14.310","article-title":"A device for dried blood microsampling in quantitative bioanalysis: Overcoming the issues associated blood hematocrit","volume":"7","author":"Spooner","year":"2015","journal-title":"Bioanalysis"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1016\/j.aca.2018.09.004","article-title":"Tutorial: Volumetric absorptive microsampling (VAMS)","volume":"1046","author":"Protti","year":"2019","journal-title":"Anal. Chim. Acta"},{"key":"ref_11","doi-asserted-by":"crossref","unstructured":"Wang, X., Dai, X., Wan, S., Fan, Y., Wu, L., Xu, H., Yan, L., Gong, X., Li, Y., and Luo, Y. (2022). A Volumetric Absorptive Microsampling UPLC-MS\/MS Method for Simultaneous Quantification of Tacrolimus, Mycophenolic Acid and Creatinine in Whole Blood of Renal Transplant Recipients. Pharmaceutics, 14.","DOI":"10.3390\/pharmaceutics14122547"},{"key":"ref_12","doi-asserted-by":"crossref","unstructured":"Marasca, C., Mandrioli, R., Sardella, R., Vovk, T., Armirotti, A., Cavalli, A., Serretti, A., Protti, M., and Mercolini, L. (2022). Dried Volumetric Microsampling Approaches for the Therapeutic Drug Monitoring of Psychiatric Patients Undergoing Clozapine Treatment. Front. Psychiatry, 13.","DOI":"10.3389\/fpsyt.2022.794609"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"114361","DOI":"10.1016\/j.jpba.2021.114361","article-title":"Determination of paracetamol and its metabolites via LC-MS\/MS in dried blood volumetric absorptive microsamples: A tool for pharmacokinetic studies","volume":"206","author":"Delahaye","year":"2021","journal-title":"J. Pharm. Biomed. Anal."},{"key":"ref_14","doi-asserted-by":"crossref","unstructured":"Pigliasco, F., Cafaro, A., Barco, S., Cresta, F., Casciaro, R., Pedemonte, N., Mattioli, F., Castellani, C., and Cangemi, G. (2025). A Novel LC-MS\/MS Method for the Measurement of Elexacaftor, Tezacaftor and Ivacaftor in Plasma, Dried Plasma Spot (DPS) and Whole Blood in Volumetric Absorptive Microsampling (VAMS) Devices. Pharmaceutics, 17.","DOI":"10.3390\/pharmaceutics17020200"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"119877","DOI":"10.1016\/j.cca.2024.119877","article-title":"A novel approach to therapeutic drug monitoring of Ciclosporin in pediatric renal transplant recipients using volumetric absorptive microsampling (VAMS)\u2014Teaching old dog new tricks","volume":"562","author":"Kocur","year":"2024","journal-title":"Clin. Chim. Acta"},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"Kocur, A., Olkowski, B., Moczulski, M., Miszewska-Szyszkowska, D., Rostkowska, O.M., Polak, K., Korniluk, K., Baczkowska, T., Durlik, M., and Pawinski, T. (2025). Therapeutic Drug Monitoring of Everolimus Using Volumetric Absorptive Microsampling and Quantitative Dried Blood Spot Methods with LC-MS\/MS in Adult Solid Organ Transplant Recipients: An Analytical and Clinical Comparative Study. Molecules, 30.","DOI":"10.3390\/molecules30153139"},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Kocur, A., Marszalek, D., Rubik, J., Czajkowska, A., and Pawinski, T. (2023). Therapeutic Drug Monitoring of Tacrolimus Based on Volumetric Absorptive Microsampling Technique (VAMS) in Renal Transplant Pediatric Recipients-LC-MS\/MS Method Development, Hematocrit Effect Evaluation, and Clinical Application. Pharmaceutics, 15.","DOI":"10.3390\/pharmaceutics15010299"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"115688","DOI":"10.1016\/j.jpba.2023.115688","article-title":"Utilization of volumetric absorptive microsampling and dried plasma spot for quantification of anti-fungal triazole agents in pediatric patients by using liquid chromatography-tandem mass spectrometry","volume":"236","author":"Simeoli","year":"2023","journal-title":"J. Pharm. Biomed. Anal."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"681","DOI":"10.1097\/FTD.0000000000000652","article-title":"Volumetric Absorptive Microsampling: A New Sampling Tool for Therapeutic Drug Monitoring of Antiepileptic Drugs","volume":"41","author":"Rudge","year":"2019","journal-title":"Ther. Drug Monit."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"2331","DOI":"10.1007\/s00216-018-0866-4","article-title":"Volumetric absorptive microsampling as an alternative tool for therapeutic drug monitoring of first-generation anti-epileptic drugs","volume":"410","author":"Velghe","year":"2018","journal-title":"Anal. Bioanal. Chem."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"2144","DOI":"10.1002\/epi4.12927","article-title":"A VAMS-based LC-MS\/MS method for precise cenobamate quantification in epilepsy (patients)","volume":"9","author":"Pigliasco","year":"2024","journal-title":"Epilepsia Open"},{"key":"ref_22","doi-asserted-by":"crossref","unstructured":"Dubois, S., Marchese, F., Pigliasco, F., Barco, S., Tripodi, G., Lomonaco, T., Lattanzi, S., Russo, E., Cangemi, G., and Striano, P. (2020). A Volumetric Absorptive Microsampling Technique to Monitor Cannabidiol Levels in Epilepsy Patients. Front. Pharmacol., 11.","DOI":"10.3389\/fphar.2020.582286"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"bkaf073","DOI":"10.1093\/jat\/bkaf073","article-title":"Development and application of an LC-MS\/MS method for 8 antiepileptic drugs and 2 metabolites using microsampling techniques (DBS and VAMS)","volume":"50","author":"Lendoiro","year":"2026","journal-title":"J. Anal. Toxicol."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"116065","DOI":"10.1016\/j.jpba.2024.116065","article-title":"Fingerprick volumetric absorptive microsampling for therapeutic drug monitoring of antiseizure medications: Reliability and real-life feasibility in epilepsy patients","volume":"242","author":"Cancellerini","year":"2024","journal-title":"J. Pharm. Biomed. Anal."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1097\/FTD.0000000000001393","article-title":"To Convert or Not to Convert? Official International Association of Therapeutic Drug Monitoring and Clinical Toxicology Guideline: Considerations and Recommendations for Converting Capillary Blood Microsampling Concentrations to Plasma Concentrations","volume":"48","author":"Boffel","year":"2026","journal-title":"Ther. Drug Monit."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"113102","DOI":"10.1016\/j.jpba.2020.113102","article-title":"Opportunities and obstacles for microsampling techniques in bioanalysis: Special focus on DBS and VAMS","volume":"182","author":"Londhe","year":"2020","journal-title":"J. Pharm. Biomed. Anal."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"704","DOI":"10.1016\/j.jpba.2017.07.033","article-title":"Volumetric adsorptive microsampling-liquid chromatography tandem mass spectrometry assay for the simultaneous quantification of four antibiotics in human blood: Method development, validation and comparison with dried blood spot","volume":"145","author":"Barco","year":"2017","journal-title":"J. Pharm. Biomed. Anal."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"997","DOI":"10.1080\/17576180.2025.2546782","article-title":"How microsampling is impacting pharmacokinetic and toxicokinetic studies: Volumetric absorptive microsampling (VAMS)","volume":"17","author":"Protti","year":"2025","journal-title":"Bioanalysis"},{"key":"ref_29","unstructured":"Committee for Medicinal Products for Human Use (2023, August 28). CHMP The ICH Guideline M10 on Bioanalytical Method Validation and Study Sample Analysis. Available online: https:\/\/www.ema.europa.eu\/en\/ich-m10-bioanalytical-method-validation-scientific-guideline."},{"key":"ref_30","doi-asserted-by":"crossref","unstructured":"Jannetto, P.J. (2017). Chapter 8\u2014Therapeutic drug monitoring using mass spectrometry. Mass Spectrometry for the Clinical Laboratory, Academic Press.","DOI":"10.1016\/B978-0-12-800871-3.00008-0"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1055\/s-0043-116492","article-title":"Consensus Guidelines for Therapeutic Drug Monitoring in Neuropsychopharmacology: Update 2017","volume":"51","author":"Hiemke","year":"2018","journal-title":"Pharmacopsychiatry"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"3019","DOI":"10.1021\/ac020361s","article-title":"Strategies for the assessment of matrix effect in quantitative bioanalytical methods based on HPLC-MS\/MS","volume":"75","author":"Matuszewski","year":"2003","journal-title":"Anal. Chem."},{"key":"ref_33","doi-asserted-by":"crossref","unstructured":"Nugraha, R.V., Yunivita, V., Santoso, P., Hasanah, A.N., Aarnoutse, R.E., and Ruslami, R. (2023). Analytical and Clinical Validation of Assays for Volumetric Absorptive Microsampling (VAMS) of Drugs in Different Blood Matrices: A Literature Review. Molecules, 28.","DOI":"10.3390\/molecules28166046"},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"431","DOI":"10.1515\/cclm.1984.22.6.431","article-title":"Comparison of Several Regression Procedures for Method Comparison Studies and Determination of Sample Sizes Application of linear regression procedures for method comparison studies in Clinical Chemistry, Part II","volume":"22","author":"Passing","year":"1984","journal-title":"Clin. Chem. Lab. Med. (CCLM)"},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1016\/S0140-6736(86)90837-8","article-title":"Statistical methods for assessing agreement between two methods of clinical measurement","volume":"1","author":"Bland","year":"1986","journal-title":"Lancet"}],"container-title":["Pharmaceuticals"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8247\/19\/8\/1188\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,29]],"date-time":"2026-07-29T13:56:56Z","timestamp":1785333416000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8247\/19\/8\/1188"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,29]]},"references-count":35,"journal-issue":{"issue":"8","published-online":{"date-parts":[[2026,8]]}},"alternative-id":["ph19081188"],"URL":"https:\/\/doi.org\/10.3390\/ph19081188","relation":{},"ISSN":["1424-8247"],"issn-type":[{"value":"1424-8247","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,29]]}}}