{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,19]],"date-time":"2026-09-19T21:15:19Z","timestamp":1789852519653,"version":"4.0.1"},"reference-count":272,"publisher":"MDPI AG","issue":"19","license":[{"start":{"date-parts":[[2023,9,24]],"date-time":"2023-09-24T00:00:00Z","timestamp":1695513600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Polymers"],"abstract":"<jats:p>The inner walls of the drinking water distribution system (DWDS) are expected to be clean to ensure a safe quality of drinking water. Complex physical, chemical, and biological processes take place when water comes into contact with the pipe surface. This paper describes the impact of leaching different compounds from the water supply pipes into drinking water and subsequent risks. Among these compounds, there are heavy metals. It is necessary to prevent these metals from getting into the DWDS. Those compounds are susceptible to impacting the quality of the water delivered to the population either by leaching dangerous chemicals into water or by enhancing the development of microorganism growth on the pipe surface. The corrosion process of different pipe materials, scale formation mechanisms, and the impact of bacteria formed in corrosion layers are discussed. Water treatment processes and the pipe materials also affect the water composition. Pipe materials act differently in the flowing and stagnation conditions. Moreover, they age differently (e.g., metal-based pipes are subjected to corrosion while polymer-based pipes have a decreased mechanical resistance) and are susceptible to enhanced bacterial film formation. Water distribution pipes are a dynamic environment, therefore, the models that are used must consider the changes that occur over time. Mathematical modeling of the leaching process is complex and includes the description of corrosion development over time, correlated with a model for the biofilm formation and the disinfectants\u2013corrosion products and disinfectants\u2013biofilm interactions. The models used for these processes range from simple longitudinal dispersion models to Monte Carlo simulations and 3D modeling. This review helps to clarify what are the possible sources of compounds responsible for drinking water quality degradation. Additionally, it gives guidance on the measures that are needed to maintain stable and safe drinking water quality.<\/jats:p>","DOI":"10.3390\/polym15193872","type":"journal-article","created":{"date-parts":[[2023,9,24]],"date-time":"2023-09-24T10:46:21Z","timestamp":1695552381000},"page":"3872","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":26,"title":["The Behavior of Polymeric Pipes in Drinking Water Distribution System\u2014Comparison with Other Pipe Materials"],"prefix":"10.3390","volume":"15","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9787-194X","authenticated-orcid":false,"given":"Daniela Simina","family":"Stefan","sequence":"first","affiliation":[{"name":"Department of Analytical Chemistry and Environmental Engineering, Faculty of Chemical Engineering and Biotechnologies, National University of Science and Technology Politehnica of Bucharest, 1-7 Polizu Street, 011061 Bucharest, Romania"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Magdalena","family":"Bosomoiu","sequence":"additional","affiliation":[{"name":"Department of Analytical Chemistry and Environmental Engineering, Faculty of Chemical Engineering and Biotechnologies, National University of Science and Technology Politehnica of Bucharest, 1-7 Polizu Street, 011061 Bucharest, Romania"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Georgeta","family":"Teodorescu","sequence":"additional","affiliation":[{"name":"Department of Analytical Chemistry and Environmental Engineering, Faculty of Chemical Engineering and Biotechnologies, National University of Science and Technology Politehnica of Bucharest, 1-7 Polizu Street, 011061 Bucharest, Romania"},{"name":"Doctoral School, Specialization of Environmental Engineering, Faculty of Chemical Engineering and Biotechnologies, National University of Science and Technology Politehnica of Bucharest, 1-7 Polizu Street, 011061 Bucharest, Romania"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2023,9,24]]},"reference":[{"key":"ref_1","unstructured":"(2023, June 08). DIRECTIVE (EU) 2020\/2184 of the European Parliament and of the Council of 16 December 2020. Available online: https:\/\/eur-lex.europa.eu\/legal-content\/EN\/TXT\/PDF\/?uri=CELEX:32020L2184."},{"key":"ref_2","doi-asserted-by":"crossref","unstructured":"Prest, E.I., Hammes, F., van Loosdrecht, M.C.M., and Vrouwenvelder, J.S. (2016). Biological Stability of Drinking Water: Controlling Factors, Methods, and Challenges. Front. Microbiol., 7.","DOI":"10.3389\/fmicb.2016.00045"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"174","DOI":"10.1002\/jobm.200610224","article-title":"Potential of the adhesion of bacteria isolated from drinking water to materials","volume":"47","author":"Simoes","year":"2007","journal-title":"J. Basic Microbiol."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"286","DOI":"10.1111\/jam.12516","article-title":"Bacterial community dynamics during the early stages of biofilm formation in a chlorinated experimental drinking water distribution system: Implications for drinking water discolouration","volume":"117","author":"Douterelo","year":"2014","journal-title":"J. Appl. Microbiol."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1016\/j.jbiotec.2004.02.012","article-title":"The influence of cell and substratum surface hydrophobicities on microbial attachment","volume":"110","author":"Liu","year":"2004","journal-title":"J. Biotechnol."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"163","DOI":"10.2166\/wst.2010.813","article-title":"Microbial diversity in biofilms on water distribution pipes of different materials","volume":"61","author":"Yu","year":"2010","journal-title":"Water Sci. Technol."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1016\/S0043-1354(99)00113-X","article-title":"Bacterial biofilm formation on polyvinyl chloride, polyethylene and stainless steel exposed to ozonated water","volume":"34","author":"Zacheus","year":"2000","journal-title":"Water Res."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1584","DOI":"10.2105\/AJPH.2007.113555","article-title":"The lead industry and Lead Water Pipes \u201cA MODEST CAMPAIGN","volume":"98","author":"Rabin","year":"2008","journal-title":"Am. J. Public Health"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"102644","DOI":"10.1016\/j.jhealeco.2022.102644","article-title":"Lead in drinking water and birth outcomes: A tale of two water treatment plants","volume":"84","author":"Dave","year":"2022","journal-title":"J. Health Econ."},{"key":"ref_10","unstructured":"(2023, September 15). Proposal for a Directive of the European Parliament and of the Council on the Quality of Water Intended for Human Consumption. Available online: https:\/\/eur-lex.europa.eu\/legal-content\/EN\/TXT\/?uri=CELEX%3A52017PC0753."},{"key":"ref_11","unstructured":"(2023, September 15). Available online: https:\/\/www.who.int\/publications\/m\/item\/chemical-fact-sheets--lead."},{"key":"ref_12","unstructured":"(2023, September 15). US Environmental Protection Agency, Safe Drinking Act Lead and Copper Rule, Available online: https:\/\/www.epa.gov\/ground-water-and-drinking-water\/basic-information-about-lead-drinking-water."},{"key":"ref_13","unstructured":"Butler, G., and Ison, H.C.K. (1966). Corrosion and Its Prevention in Waters, Leonard-Hill."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1016\/j.watres.2016.04.050","article-title":"Evaluation of exposure to lead from drinking water in large buildings","volume":"99","author":"Deshommes","year":"2016","journal-title":"Water Res."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"110","DOI":"10.1016\/j.watres.2018.04.045","article-title":"Sampling in schools and large institutional buildings: Implications for regulations, exposure and management of lead and copper","volume":"140","author":"Dore","year":"2018","journal-title":"Water Res."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"327","DOI":"10.1016\/j.watres.2019.03.005","article-title":"True exposure to lead at the tap: Insights from proportional sampling, regulated sampling and water use monitoring","volume":"156","author":"Riblet","year":"2019","journal-title":"Water Res."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"116641","DOI":"10.1016\/j.watres.2020.116641","article-title":"Developing a framework for classifying water lead levels at private drinking water systems: A Bayesian Belief Network approach","volume":"189","author":"Fasaee","year":"2021","journal-title":"Water Res."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"489","DOI":"10.1093\/aje\/kwn348","article-title":"Aluminum and Silica in Drinking Water and the Risk of Alzheimer\u2019s Disease or Cognitive Decline: Findings From 15-Year Follow-up of the PAQUID Cohort","volume":"169","author":"Rondeau","year":"2009","journal-title":"Am. J. Epidemiol."},{"key":"ref_19","unstructured":"(2023, September 15). Available online: https:\/\/www.who.int\/publications\/m\/item\/chemical-fact-sheets--aluminium."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"224","DOI":"10.1016\/j.envres.2004.07.017","article-title":"Cancer incidence and asbestos in drinking water, Town of Woodstock, New York, 1980\u20131998","volume":"98","author":"Browne","year":"2005","journal-title":"Environ. Res."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"593","DOI":"10.1007\/s10552-004-7844-1","article-title":"Cancer of the gastrointestinal tract and exposure to asbestos in drinking water among lighthouse keepers (Norway)","volume":"16","author":"Ulvestad","year":"2005","journal-title":"Cancer Causes Control"},{"key":"ref_22","unstructured":"(2023, September 15). Available online: https:\/\/www.epa.gov\/sites\/default\/files\/2015-06\/documents\/ny_hh_336_w_03121998.pdf."},{"key":"ref_23","unstructured":"(2023, September 15). Available online: https:\/\/www.anses.fr\/en\/content\/asbestos-still-very-topical-problem."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"50","DOI":"10.1016\/j.scitotenv.2005.05.022","article-title":"Daily intakes of copper, zinc and arsenic in drinking water by population of Shanghai, China","volume":"362","author":"Xu","year":"2006","journal-title":"Sci. Total Environ."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"101865","DOI":"10.1016\/j.jksus.2022.101865","article-title":"Impact of heavy metals on the environment and human health: Novel therapeutic insights to counter the toxicity","volume":"34","author":"Mitra","year":"2022","journal-title":"J. King Saud Univ. Sci."},{"key":"ref_26","doi-asserted-by":"crossref","unstructured":"Bhat, R.A., Bakhshalizadeh, S., Guerrera, M.C., Kesbi\u00e7, O.S., and Fazio, F. (2023). Toxic effect of heavy metals on ovarian deformities, apoptotic changes, oxidative stress, and steroid hormones in rainbow trout. J. Trace Elem. Med. Biol., 75.","DOI":"10.1016\/j.jtemb.2022.127106"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"130928","DOI":"10.1016\/j.jhazmat.2023.130928","article-title":"Toxicity risks associated with trace metals call for conservation of threatened fish species in heavily sediment-laden Yellow River","volume":"448","author":"Li","year":"2023","journal-title":"J. Hazard. Mater."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"100545","DOI":"10.1016\/j.jics.2022.100545","article-title":"Analytical approaches on some selected toxic heavy metals in the environment and their socio-environmental impacts: A meticulous review","volume":"99","author":"Patle","year":"2022","journal-title":"J. Indian Chem. Soc."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"114455","DOI":"10.1016\/j.molliq.2020.114455","article-title":"Toxicity of heavy metals in plants and animals and their uptake by magnetic iron oxide nanoparticles","volume":"321","author":"Rehman","year":"2021","journal-title":"J. Mol. Liq."},{"key":"ref_30","unstructured":"(2023, September 15). Available online: https:\/\/www.who.int\/publications\/m\/item\/chemical-fact-sheets--arsenic."},{"key":"ref_31","unstructured":"(2023, September 15). Available online: https:\/\/www.who.int\/publications\/m\/item\/chemical-fact-sheets--chromium."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"111386","DOI":"10.1016\/j.jenvman.2020.111386","article-title":"Effective immobilization of hexavalent chromium from drinking water by nano-FeOOH coating activated carbon: Adsorption and reduction","volume":"277","author":"Li","year":"2021","journal-title":"J. Environ. Manag."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"132512","DOI":"10.1016\/j.jclepro.2022.132512","article-title":"Leaching of chromium and lead from the cement mortar lining into the flowing drinking water shortly after pipeline rehabilitation","volume":"362","author":"Zielina","year":"2022","journal-title":"J. Clean. Prod."},{"key":"ref_34","unstructured":"(2023, September 15). Available online: https:\/\/www.who.int\/publications\/m\/item\/chemical-fact-sheets--cadmium."},{"key":"ref_35","unstructured":"(2023, September 16). Available online: https:\/\/www.atsdr.cdc.gov\/spl\/index.html#2022spl."},{"key":"ref_36","unstructured":"(2023, September 16). Available online: https:\/\/www.who.int\/publications\/m\/item\/chemical-fact-sheets--antimony."},{"key":"ref_37","unstructured":"(2023, September 16). Available online: https:\/\/www.who.int\/publications\/m\/item\/chemical-fact-sheets--copper."},{"key":"ref_38","unstructured":"(2023, September 16). Available online: https:\/\/www.who.int\/publications\/m\/item\/chemical-fact-sheets--manganese."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"105648","DOI":"10.1016\/j.aquatox.2020.105648","article-title":"Investigating the mechanism of vanadium toxicity in freshwater organisms","volume":"229","author":"Meina","year":"2020","journal-title":"Aquat. Toxicol."},{"key":"ref_40","unstructured":"(2023, September 16). Available online: https:\/\/www.who.int\/publications\/m\/item\/chemical-fact-sheets--vinyl-chloride."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"5049","DOI":"10.1016\/j.watres.2012.06.046","article-title":"Impact of galvanic corrosion on lead release from aged lead service lines","volume":"46","author":"Wang","year":"2012","journal-title":"Water Res."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"16","DOI":"10.5991\/OPF.2018.44.0027","article-title":"Identify Lead Plumbing Sources to Protect Public Health","volume":"44","author":"Lytle","year":"2018","journal-title":"Opflow"},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"e1246","DOI":"10.1002\/aws2.1246","article-title":"Lead pipe and lead\u2013tin solder scale formation and structure: A conceptual model","volume":"3","author":"Snoeyink","year":"2021","journal-title":"AWWA Wat. Sci."},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"118890","DOI":"10.1016\/j.watres.2022.118890","article-title":"Effects of pipeline geometry, sample volume, and flow rate on Pb monitoring outcomes in copper pipe drinking water supply systems","volume":"222","author":"Chang","year":"2022","journal-title":"Water Res."},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"129169","DOI":"10.1016\/j.jhazmat.2022.129169","article-title":"Prediction of lead leaching from galvanic corrosion of lead-containing components in copper pipe drinking water supply systems","volume":"436","author":"Chang","year":"2022","journal-title":"J. Hazard. Mater."},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"1510","DOI":"10.1016\/j.scitotenv.2018.04.402","article-title":"Lead as a legendary pollutant with emerging concern: Survey of lead in tap water in an old campus building using four sampling methods","volume":"636","author":"Ng","year":"2018","journal-title":"Sci. Total Environ."},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"661","DOI":"10.1016\/j.watres.2012.10.033","article-title":"Impact of treatment on Pb release from full and partially replaced harvested Lead Service Lines (LSLs)","volume":"47","author":"Cartier","year":"2013","journal-title":"Water Res."},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"1297","DOI":"10.1080\/10643389.2011.556556","article-title":"Lead (Pb) in Tap Water and in Blood: Implications for Lead Exposure in the United States","volume":"42","author":"Triantafyllidou","year":"2012","journal-title":"Crit. Rev. Environ. Sci. Technol."},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"3365","DOI":"10.1021\/acs.est.7b06010","article-title":"Mineralogical evidence of galvanic corrosion in drinking water lead pipe joints","volume":"52","author":"DeSantis","year":"2018","journal-title":"Environ. Sci. Technol."},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"2763","DOI":"10.1016\/j.watres.2011.02.023","article-title":"Effect of pH on the concentrations of lead and trace contaminants in drinking water: A combined batch, pipe loop and sentinel home study","volume":"45","author":"Kim","year":"2011","journal-title":"Water Res."},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1016\/j.watres.2014.02.004","article-title":"Effect of water chemistry on the dissolution rate of the lead corrosion product hydrocerussite","volume":"54","author":"Noel","year":"2014","journal-title":"Water Res."},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"106259","DOI":"10.1016\/j.envint.2020.106259","article-title":"Variability and sampling of lead (Pb) in drinking water: Assessing potential human exposure depends on the sampling protocol","volume":"146","author":"Triantafyllidou","year":"2021","journal-title":"Environ. Int."},{"key":"ref_53","doi-asserted-by":"crossref","first-page":"111186","DOI":"10.1016\/j.jenvman.2020.111186","article-title":"Optimization of disinfectant dosage for simultaneous control of lead and disinfection-byproducts in water distribution networks","volume":"276","author":"Maheshwari","year":"2020","journal-title":"J. Environ. Manag."},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"1498","DOI":"10.1016\/j.scitotenv.2017.07.119","article-title":"Increasing chloride in rivers of the conterminous U.S. and linkages to potential corrosivity and lead action level exceedances in drinking water","volume":"613\u2013614","author":"Stets","year":"2018","journal-title":"Sci. Total Environ."},{"key":"ref_55","doi-asserted-by":"crossref","first-page":"13672","DOI":"10.1021\/acs.est.0c03797","article-title":"Lead Particle Size Fractionation and Identification in Newark, New Jersey\u2019s Drinking Water","volume":"54","author":"Lytle","year":"2020","journal-title":"Environ. Sci. Technol."},{"key":"ref_56","doi-asserted-by":"crossref","first-page":"6054","DOI":"10.1021\/es101328u","article-title":"Characteristics of Lead Corrosion Scales Formed during Drinking Water Distribution and Their Influence on the Release of Lead and Other Contaminants","volume":"44","author":"Kim","year":"2010","journal-title":"Environ. Sci. Technol."},{"key":"ref_57","doi-asserted-by":"crossref","first-page":"4412","DOI":"10.1021\/es900501t","article-title":"Identification and Distribution of Vanadinite (Pb5(V5+O4)3Cl) in Lead Pipe Corrosion By-Products","volume":"43","author":"Gerke","year":"2009","journal-title":"Environ. Sci. Technol."},{"key":"ref_58","doi-asserted-by":"crossref","first-page":"336","DOI":"10.5942\/jawwa.2014.106.0064","article-title":"Importance of pipe deposits to Lead and Copper Rule compliance","volume":"106","author":"Schock","year":"2014","journal-title":"J. Am. Water Works Assoc."},{"key":"ref_59","doi-asserted-by":"crossref","first-page":"e1278","DOI":"10.1002\/aws2.1278","article-title":"A holistic approach to lead pipe scale analysis: Importance, methodology, and limitations","volume":"4","author":"Harmon","year":"2022","journal-title":"AWWA Wat. Sci."},{"key":"ref_60","doi-asserted-by":"crossref","first-page":"160","DOI":"10.1038\/s41370-022-00461-6","article-title":"A national survey of lead and other metal(loids) in residential drinking water in the United States","volume":"33","author":"Bradham","year":"2023","journal-title":"J. Expo. Sci. Environ. Epidemiol."},{"key":"ref_61","doi-asserted-by":"crossref","first-page":"3746","DOI":"10.1021\/es505886h","article-title":"Low Contribution of PbO2-Coated Lead Service Lines to Water Lead Contamination at the Tap","volume":"49","author":"Triantafyllidou","year":"2015","journal-title":"Environ. Sci. Technol."},{"key":"ref_62","unstructured":"(2023, July 03). Available online: https:\/\/www.lenntech.com\/periodic\/water\/lead\/lead-and-water.htm."},{"key":"ref_63","doi-asserted-by":"crossref","first-page":"475","DOI":"10.1061\/(ASCE)0733-9372(2000)126:5(475)","article-title":"Effect of calcium on lead in soft-water distribution systems","volume":"126","author":"Bisogni","year":"2000","journal-title":"J. Environ. Eng."},{"key":"ref_64","doi-asserted-by":"crossref","first-page":"151","DOI":"10.1016\/j.jhazmat.2016.03.001","article-title":"A new analytical approach to understanding nanoscale lead-iron interactions in drinking water distribution systems","volume":"311","author":"Trueman","year":"2016","journal-title":"J. Hazard. Mater."},{"key":"ref_65","doi-asserted-by":"crossref","first-page":"14302","DOI":"10.1021\/acs.est.0c03027","article-title":"Orthophosphate Interactions with Destabilized PbO2 Scales","volume":"54","author":"DeSantis","year":"2020","journal-title":"Environ. Sci. Technol."},{"key":"ref_66","doi-asserted-by":"crossref","first-page":"626","DOI":"10.1002\/j.1551-8833.1980.tb04599.x","article-title":"Bacterial, chemical, and mineralogical characteristics of tubercles in distribution pipelines","volume":"72","author":"Touvinen","year":"1980","journal-title":"J. Am. Water Works Assoc."},{"key":"ref_67","doi-asserted-by":"crossref","unstructured":"Katner, A., Pieper, K., Brown, K., Lin, H.Y., Parks, J., Wang, X., Hu, C.Y., Masters, S., Mielke, H., and Edwards, M. (2018). Effectiveness of Prevailing Flush Guidelines to Prevent Exposure to Lead in Tap Water. Int. J. Environ. Res. Public Health, 15.","DOI":"10.20944\/preprints201805.0405.v1"},{"key":"ref_68","doi-asserted-by":"crossref","first-page":"e1127","DOI":"10.1002\/aws2.1127","article-title":"Water quality\u2013pipe deposit relationships in Midwestern lead pipes","volume":"1","author":"Tully","year":"2019","journal-title":"AWWA Wat. Sci."},{"key":"ref_69","doi-asserted-by":"crossref","first-page":"E464","DOI":"10.5942\/jawwa.2017.109.0121","article-title":"Scale Formation Under Blended Phosphate Treatment for a Utility With Lead Pipes","volume":"109","author":"Wasserstrom","year":"2017","journal-title":"J. Am. Water Works Assoc."},{"key":"ref_70","unstructured":"(2023, July 15). Available online: https:\/\/www.rinkerpipe.com\/a-complete-guide-to-reinforced-concrete-pipe\/."},{"key":"ref_71","unstructured":"Meland, I.S. (June, January 30). Durability of mortar linings in ductile iron pipes. In: Durability of building materials and components. Proceedings of the Eighth International Conference on Durability of Building Materials and Components, Vancouver, BC, Canada."},{"key":"ref_72","doi-asserted-by":"crossref","first-page":"332","DOI":"10.1038\/232332a0","article-title":"Asbestos fibres in beverages and drinking water","volume":"232","author":"Cunningham","year":"1971","journal-title":"Nature"},{"key":"ref_73","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1016\/S0013-9351(88)80029-X","article-title":"Asbestos-Contaminated Drinking Water: Its Impact on Household Air","volume":"46","author":"Webber","year":"1988","journal-title":"Environ. Res."},{"key":"ref_74","doi-asserted-by":"crossref","first-page":"131977","DOI":"10.1016\/j.chemosphere.2021.131977","article-title":"Degradation of asbestos\u2014Reinforced water supply cement pipes after a long-term operation","volume":"287","author":"Zavasnik","year":"2022","journal-title":"Chemosphere"},{"key":"ref_75","doi-asserted-by":"crossref","first-page":"4445","DOI":"10.2166\/ws.2022.108","article-title":"The concentration and prevalence of asbestos fibres in Christchurch, New Zealand\u2019s drinking water supply","volume":"22","author":"Mager","year":"2022","journal-title":"Water Supply"},{"key":"ref_76","unstructured":"Mindess, S., and Young, F. (1981). Concrete, Prentice-Hall."},{"key":"ref_77","unstructured":"Kosmatka, S., and Panarese, W. (1988). Design and Control of Concrete Mixes, Portland Cement Association."},{"key":"ref_78","doi-asserted-by":"crossref","first-page":"104602","DOI":"10.1016\/j.cemconcomp.2022.104602","article-title":"Binding of Cu(II) and Zn(II) in Portland cement immobilization systems: Effect of C-A-S-H composition","volume":"131","author":"Liu","year":"2022","journal-title":"Cem. Concr. Compos."},{"key":"ref_79","first-page":"233","article-title":"Use of rice husk ash in concrete","volume":"6","author":"Mattit","year":"1984","journal-title":"Int. J. Cem. Compos. Lightweight Concr."},{"key":"ref_80","first-page":"723","article-title":"Cement Mortar Lining as a Potential Source of Water Contamination","volume":"8","author":"Zielina","year":"2014","journal-title":"Int. J. Environ. Ecol. Eng."},{"key":"ref_81","doi-asserted-by":"crossref","unstructured":"M\u0142y\u0144ska, A., and Zielina, M. (2017, January 23\u201325). The influence of prefabricated pipe cement coatings and those made during pipe renovation on drinking water quality. Proceedings of the E3S Web of Conferences, 9th Conference on Interdisciplinary Problems in Environmental Protection and Engineering EKO-DOK, Bogusz\u00f3w-Gorce, Poland.","DOI":"10.1051\/e3sconf\/20171700061"},{"key":"ref_82","doi-asserted-by":"crossref","first-page":"685","DOI":"10.2166\/aqua.2018.063","article-title":"A comparative study of Portland cements CEM I used for water pipe renovation in terms of pollutants leaching from cement coatings and their impact on water quality","volume":"67","author":"Zielina","year":"2018","journal-title":"J. Water Supply Res. Technol. AQUA"},{"key":"ref_83","unstructured":"Achternbosch, M., Brautigam, K.R., Hartlieb, N., Kupsch, C., Richers, U., and Stemmermann, P. (2003). Heavy Metals in Cement and Concrete Resulting from the Co-Incineration of Wastes in Cement Kilns with Regard to the Legitimacy of Waste Utilisation, Forschungszentrum Karlsruhe. Umweltforschungsplan Des Bundesministeriums F\u00fcr Umwelt, Naturschutz und Reaktorsicherheit, F\u00f6rderkennzeichen (UFOPLAN No.) 200 33 335."},{"key":"ref_84","doi-asserted-by":"crossref","first-page":"94","DOI":"10.1016\/j.jclepro.2013.02.026","article-title":"The effect of using thermally dried sewage sludge as an alternative fuel on Portland cement clinker production","volume":"52","author":"Donatello","year":"2013","journal-title":"J. Clean. Prod."},{"key":"ref_85","doi-asserted-by":"crossref","first-page":"481","DOI":"10.1016\/j.fuel.2016.07.038","article-title":"Influence of alternative fuels on trace element content of ordinary portland cement","volume":"184","author":"Horsley","year":"2016","journal-title":"Fuel"},{"key":"ref_86","doi-asserted-by":"crossref","first-page":"127754","DOI":"10.1016\/j.conbuildmat.2022.127754","article-title":"Effects of phosphorus and iron on the composition and property of Portland cement clinker utilized incinerated sewage sludge ash","volume":"341","author":"Guo","year":"2022","journal-title":"Constr. Build. Mater."},{"key":"ref_87","doi-asserted-by":"crossref","first-page":"516","DOI":"10.1007\/s42452-019-0507-3","article-title":"Contamination of drinking water soon after cement mortar lining renovation depending on the disinfectant doses","volume":"1","author":"Mlynska","year":"2019","journal-title":"SN Appl. Sci."},{"key":"ref_88","unstructured":"Ekstr\u00f6m, T. (2001). Leaching of Concrete: Experiments and Modelling. [Licentiate Thesis, Lund University, Division of Building Materials]."},{"key":"ref_89","doi-asserted-by":"crossref","first-page":"711","DOI":"10.1016\/j.cemconres.2003.10.025","article-title":"Effect of crack opening on the local diffusion of chloride in inert materials","volume":"34","author":"Ismail","year":"2004","journal-title":"Cem. Concr. Res."},{"key":"ref_90","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1016\/j.conbuildmat.2015.03.003","article-title":"Time dependence and service life prediction of chloride resistance of concrete coatings","volume":"83","author":"Li","year":"2015","journal-title":"Constr. Build. Mater."},{"key":"ref_91","doi-asserted-by":"crossref","first-page":"402","DOI":"10.1016\/j.conbuildmat.2017.12.111","article-title":"Effect of pore structures on gas permeability and chloride diffusivity of concrete","volume":"163","author":"Zhang","year":"2018","journal-title":"Constr. Build. Mater."},{"key":"ref_92","doi-asserted-by":"crossref","first-page":"117182","DOI":"10.1016\/j.conbuildmat.2019.117182","article-title":"The difference in chloride ion diffusion coefficient of concrete made with drinking water and wastewater","volume":"231","author":"Hassani","year":"2020","journal-title":"Constr. Build. Mater."},{"key":"ref_93","doi-asserted-by":"crossref","first-page":"117556","DOI":"10.1016\/j.conbuildmat.2019.117556","article-title":"Experimental studies on the chloride ion permeability of concrete considering the effect of freeze\u2013thaw damage","volume":"236","author":"Wang","year":"2020","journal-title":"Constr. Build. Mater."},{"key":"ref_94","doi-asserted-by":"crossref","first-page":"381","DOI":"10.1007\/s11267-009-9234-x","article-title":"Leaching of Alkali from Concrete in Contact with Waterways","volume":"9","author":"Setunge","year":"2009","journal-title":"Water Air Soil Pollut. Focus"},{"key":"ref_95","doi-asserted-by":"crossref","first-page":"321","DOI":"10.1016\/j.conbuildmat.2017.08.156","article-title":"Concrete filled PVC tube: A review","volume":"156","author":"Abdulla","year":"2017","journal-title":"Constr. Build. Mater."},{"key":"ref_96","doi-asserted-by":"crossref","first-page":"104957","DOI":"10.1016\/j.jobe.2022.104957","article-title":"Effects of pipe diameter, curing age and exposure temperature on chloride diffusion of concrete with embedded PVC pipe","volume":"57","author":"Du","year":"2022","journal-title":"J. Build. Eng."},{"key":"ref_97","unstructured":"(2023, September 15). COMMISSION DIRECTIVE 1999\/77\/EC of 26 July 1999 Adapting to Technical Progress for the Sixth Time Annex I to Council Directive 76\/769\/EEC on the Approximation of the Laws, Regulations and Administrative Provisions of the Member States Relating to Restrictions on the Marketing and Use of Certain Dangerous Substances and Preparations (Asbestos). Available online: https:\/\/eur-lex.europa.eu\/legal-content\/EN\/TXT\/PDF\/?uri=CELEX:31999L0077&qid=1695460632571."},{"key":"ref_98","unstructured":"(2023, September 15). Available online: https:\/\/www.canada.ca\/en\/health-canada\/services\/publications\/healthy-living\/asbestos-drinking-water-infographic-2021.html."},{"key":"ref_99","doi-asserted-by":"crossref","first-page":"15730","DOI":"10.1016\/j.heliyon.2023.e15730","article-title":"A critical review of asbestos concentrations in water and air, according to exposure sources","volume":"9","author":"Saba","year":"2023","journal-title":"Heliyon"},{"key":"ref_100","unstructured":"(2023, September 15). Available online: https:\/\/www.wsaa.asn.au\/sites\/default\/files\/publication\/download\/Asbestos%20Fact%20Sheet%202017.pdf."},{"key":"ref_101","unstructured":"(2023, September 15). Available online: https:\/\/www.sawater.com.au\/__data\/assets\/pdf_file\/0008\/193616\/SA-Water-Fact-Sheet-asbestos-cement-pipes.pdf."},{"key":"ref_102","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1016\/j.jes.2015.12.035","article-title":"Stainless steel corrosion scale formed in reclaimed water: Characteristics, model for scale growth and metal element release","volume":"48","author":"Cui","year":"2016","journal-title":"J. Environ. Sci."},{"key":"ref_103","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1179\/174327806X94009","article-title":"General corrosion of copper in domestic drinking water installations: Scientific background and mechanistic understanding","volume":"41","author":"Merkel","year":"2006","journal-title":"Corros. Eng. Sci. Technol."},{"key":"ref_104","doi-asserted-by":"crossref","first-page":"138","DOI":"10.1016\/j.desal.2015.07.028","article-title":"Performance of inhibitors on CaCO3 scale deposition in stainless steel & copper pipe surface","volume":"375","author":"Hussain","year":"2015","journal-title":"Desalination"},{"key":"ref_105","doi-asserted-by":"crossref","first-page":"119597","DOI":"10.1016\/j.watres.2023.119597","article-title":"Study on electrochemical reduction mechanisms of iron oxides in pipe scale in drinking water distribution system","volume":"231","author":"Zhao","year":"2023","journal-title":"Water Res."},{"key":"ref_106","unstructured":"Schock, M.R., Lytle, D.A., and Clement, J.A. (1995). Effect of pH, DIC, Orthophosphate and Sulfate on Drinking Water Cuprosolvency, USEPA, Office of Research and Development. EPA\/600\/R-95\/085."},{"key":"ref_107","doi-asserted-by":"crossref","first-page":"1030","DOI":"10.1016\/j.corsci.2009.02.014","article-title":"Influence of solid corrosion by-products on the consumption of dissolved oxygen in copper pipes","volume":"51","author":"Vargas","year":"2009","journal-title":"Corros. Sci."},{"key":"ref_108","doi-asserted-by":"crossref","first-page":"536","DOI":"10.5006\/1.3577869","article-title":"A Morphological Study of Pitting Corrosion of Copper in Soft Tap Water","volume":"45","author":"Shalaby","year":"1989","journal-title":"Corrosion"},{"key":"ref_109","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1002\/maco.200905241","article-title":"Copper corrosion in drinking water systems\u2014Effect of pH and phosphate-dosage","volume":"61","author":"Dartmann","year":"2010","journal-title":"Mater. Corros."},{"key":"ref_110","doi-asserted-by":"crossref","first-page":"683","DOI":"10.1016\/S0043-1354(00)00320-1","article-title":"Role of temperature, chlorine, and organic matter in copper corrosion by-product release in soft water","volume":"35","author":"Boulay","year":"2001","journal-title":"Water Res."},{"key":"ref_111","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1002\/j.1551-8833.2004.tb10724.x","article-title":"Role of chlorine and chloramine in corrosion of lead bearing plumbing materials","volume":"96","author":"Edwards","year":"2004","journal-title":"J. Am. Water Work. Assoc."},{"key":"ref_112","doi-asserted-by":"crossref","first-page":"1057","DOI":"10.1016\/S0010-938X(01)00112-3","article-title":"Phosphate inhibition of soluble copper corrosion by-product release","volume":"44","author":"Edwards","year":"2002","journal-title":"Corros. Sci."},{"key":"ref_113","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1002\/awwa.1109","article-title":"A Model for Estimating the Impact of Orthophosphate on Copper in Water","volume":"110","author":"Lytle","year":"2018","journal-title":"J. Am. Water Works Assoc."},{"key":"ref_114","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1016\/0265-3036(91)90004-B","article-title":"Continuous culture studies of biofilm associated with copper corrosion","volume":"27","author":"Walker","year":"1991","journal-title":"Int. Biodeter."},{"key":"ref_115","doi-asserted-by":"crossref","first-page":"177","DOI":"10.1023\/A:1008206918628","article-title":"Microbiologically influenced copper corrosion in potable water with emphasis on practical relevance","volume":"8","author":"Wagner","year":"1997","journal-title":"Biodegradation"},{"key":"ref_116","doi-asserted-by":"crossref","first-page":"91","DOI":"10.2166\/wst.2004.0096","article-title":"The physico-chemistry of biofilm-mediated pitting corrosion of copper pipe supplying potable water","volume":"49","author":"Keevil","year":"2004","journal-title":"Water Sci. Technol."},{"key":"ref_117","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1016\/j.ibiod.2007.06.001","article-title":"Microbiologically induced corrosion of copper pipes in low-pH water","volume":"61","author":"Reyes","year":"2008","journal-title":"Int. Biodeterior. Biodegrad."},{"key":"ref_118","doi-asserted-by":"crossref","first-page":"473","DOI":"10.1016\/j.corsci.2013.11.064","article-title":"Experimental evidence for enhanced copper release from domestic copper plumbing under hydrodynamic control","volume":"80","author":"Olivares","year":"2014","journal-title":"Corros. Sci."},{"key":"ref_119","doi-asserted-by":"crossref","unstructured":"Ng, D.Q., and Lin, Y.P. (2016). Evaluation of Lead Release in a Simulated Lead-Free Premise Plumbing System Using a Sequential Sampling Approach. Int. J. Environ. Res. Public Health, 13.","DOI":"10.3390\/ijerph13030266"},{"key":"ref_120","doi-asserted-by":"crossref","first-page":"280","DOI":"10.1002\/j.1551-8833.1980.tb04512.x","article-title":"An experimental approach to corrosion control","volume":"72","author":"Shull","year":"1980","journal-title":"J. Am. Water Works Assoc."},{"key":"ref_121","doi-asserted-by":"crossref","first-page":"91","DOI":"10.2166\/ws.2001.0056","article-title":"Water treatment to reduce internal corrosion in the drinking water distribution system in Oslo","volume":"1","author":"Hem","year":"2001","journal-title":"Water Sci. Technol. Water Supply"},{"key":"ref_122","doi-asserted-by":"crossref","first-page":"322","DOI":"10.1016\/j.corsci.2005.02.005","article-title":"Characteristics of iron corrosion scales established under blending of ground, surface, and saline waters and their impacts on iron release in the pipe distribution system","volume":"48","author":"Tang","year":"2006","journal-title":"Corros. Sci."},{"key":"ref_123","doi-asserted-by":"crossref","first-page":"136","DOI":"10.1016\/j.watres.2014.05.053","article-title":"Changes of the corrosion potential of iron in stagnation and flow conditions and their relationship with metal release","volume":"62","author":"Fabbricino","year":"2014","journal-title":"Water Res."},{"key":"ref_124","doi-asserted-by":"crossref","first-page":"417","DOI":"10.1007\/s11783-013-0558-4","article-title":"A red water occurrence in drinking water distribution systems caused by changes in water source in Beijing, China: Mechanism analysis and control measures","volume":"8","author":"Zhang","year":"2014","journal-title":"Front. Environ. Sci. Eng."},{"key":"ref_125","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1016\/j.watres.2014.04.003","article-title":"Effect of sulfate on the transformation of corrosion scale composition and bacterial community in cast iron water distribution pipes","volume":"59","author":"Yang","year":"2014","journal-title":"Water Res."},{"key":"ref_126","doi-asserted-by":"crossref","first-page":"119146","DOI":"10.1016\/j.watres.2022.119146","article-title":"Impact of initial chlorine concentration on water quality change in old unlined iron pipes","volume":"225","author":"Li","year":"2022","journal-title":"Water Res."},{"key":"ref_127","unstructured":"(1996). Internal Corrosion of Water Distribution Systems, AWWA Research Foundation, DVGW-Technologiezentrum Wasser. [2nd ed.]."},{"key":"ref_128","doi-asserted-by":"crossref","first-page":"498","DOI":"10.5006\/1.3277640","article-title":"Oxidation of Fe2+ ions in sulfate- and chloride-containing aqueous medium","volume":"58","author":"Oh","year":"2002","journal-title":"Corrosion"},{"key":"ref_129","doi-asserted-by":"crossref","first-page":"88","DOI":"10.1002\/j.1551-8833.2001.tb09246.x","article-title":"Iron pipe corrosion in distribution systems","volume":"93","author":"McNeill","year":"2001","journal-title":"J. Am. Water Works Assoc."},{"key":"ref_130","doi-asserted-by":"crossref","first-page":"5257","DOI":"10.1016\/j.watres.2013.06.004","article-title":"Effects of chloride, sulfate and natural organic matter (NOM) on the accumulation and release of trace-level inorganic contaminants from corroding iron","volume":"47","author":"Peng","year":"2013","journal-title":"Water Res."},{"key":"ref_131","doi-asserted-by":"crossref","unstructured":"Sachan, R., Singh, A.K., and Negi, Y.S. (2020). Study of Microbially Influenced Corrosion in the Presence of Iron-Oxidizing Bacteria (Strain DASEWM2). J. Bio-Tribo-Corros., 6.","DOI":"10.1007\/s40735-020-00409-z"},{"key":"ref_132","doi-asserted-by":"crossref","first-page":"129396","DOI":"10.1016\/j.chemosphere.2020.129396","article-title":"Accumulation of vanadium and arsenic by cast iron pipe scales under drinking water conditions: A batch study","volume":"269","author":"He","year":"2021","journal-title":"Chemosphere"},{"key":"ref_133","doi-asserted-by":"crossref","first-page":"221","DOI":"10.1016\/0010-938X(88)90106-0","article-title":"Investigations of the reduction and re-oxidation kinetics of iron (III) oxide scales formed in waters","volume":"28","author":"Kuch","year":"1988","journal-title":"Corros. Sci."},{"key":"ref_134","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1016\/j.jes.2021.03.016","article-title":"Modeling iron release from cast iron pipes in an urban water distribution system caused by source water switch","volume":"110","author":"Lin","year":"2021","journal-title":"J. Environ. Sci."},{"key":"ref_135","doi-asserted-by":"crossref","first-page":"177","DOI":"10.1016\/j.jes.2018.03.004","article-title":"Variations regularity of microorganisms and corrosion of cast iron in water distribution system","volume":"74","author":"Qiu","year":"2018","journal-title":"J. Environ. Sci."},{"key":"ref_136","doi-asserted-by":"crossref","first-page":"88","DOI":"10.1002\/j.1551-8833.2005.tb10915.x","article-title":"Corrosion and corrosion control of iron pipe: 75 years of research","volume":"97","author":"Bonds","year":"2005","journal-title":"J.-Am. Water Work. Assoc."},{"key":"ref_137","doi-asserted-by":"crossref","first-page":"156465","DOI":"10.1016\/j.scitotenv.2022.156465","article-title":"Characteristics of vanadium release from layered steel pipe scales to bulk, steady, and occluded water in drinking water distribution systems","volume":"838","author":"Tian","year":"2022","journal-title":"Sci. Total Environ."},{"key":"ref_138","doi-asserted-by":"crossref","first-page":"5845","DOI":"10.1016\/j.scitotenv.2010.08.036","article-title":"Speciation and distribution of vanadium in drinking water iron pipe corrosion by-products","volume":"408","author":"Gerke","year":"2010","journal-title":"Sci. Total Environ."},{"key":"ref_139","doi-asserted-by":"crossref","first-page":"18778","DOI":"10.1007\/s11356-021-15754-w","article-title":"Cr release after Cr(III) and Cr(VI) enrichment from different layers of cast iron corrosion scales in drinking water distribution systems: The impact of pH, temperature, sulfate, and chloride","volume":"29","author":"Tian","year":"2022","journal-title":"Environ. Sci. Pollut. Res."},{"key":"ref_140","doi-asserted-by":"crossref","first-page":"127904","DOI":"10.1016\/j.chemosphere.2020.127904","article-title":"Manganese release from corrosion products of cast iron pipes in drinking water distribution systems: Effect of water temperature, pH, alkalinity, SO42\u2212 concentration and disinfectants","volume":"262","author":"Zhang","year":"2021","journal-title":"Chemosphere"},{"key":"ref_141","doi-asserted-by":"crossref","first-page":"5423","DOI":"10.1016\/j.watres.2012.07.031","article-title":"Morphological and physicochemical characteristics of iron corrosion scales formed under different water source histories in a drinking water distribution system","volume":"46","author":"Yang","year":"2012","journal-title":"Water Res."},{"key":"ref_142","doi-asserted-by":"crossref","first-page":"173","DOI":"10.1016\/j.jes.2022.04.024","article-title":"Review on corrosion and corrosion scale formation upon unlined cast iron pipes in drinking water distribution systems","volume":"117","author":"Zhang","year":"2022","journal-title":"J. Environ. Sci."},{"key":"ref_143","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.watres.2011.10.006","article-title":"Corrosion in drinking water pipes: The importance of green rusts","volume":"46","author":"Swietlik","year":"2012","journal-title":"Water Res."},{"key":"ref_144","doi-asserted-by":"crossref","first-page":"115742","DOI":"10.1016\/j.watres.2020.115742","article-title":"Early period corrosion and scaling characteristics of ductile iron pipe for ground water supply with sodium hypochlorite disinfection","volume":"176","author":"Zhang","year":"2020","journal-title":"Water Res."},{"key":"ref_145","doi-asserted-by":"crossref","first-page":"177","DOI":"10.1016\/j.scitotenv.2017.02.108","article-title":"Formation of known and unknown disinfection by-products from natural organic matter fractions during chlorination, chloramination, and ozonation","volume":"587\u2013588","author":"Li","year":"2017","journal-title":"Sci. Total Environ."},{"key":"ref_146","doi-asserted-by":"crossref","first-page":"166","DOI":"10.1016\/j.jhazmat.2018.07.022","article-title":"Chemical characterization and relative toxicity assessment of disinfection byproduct mixtures in a large drinking water supply network","volume":"359","author":"Postigo","year":"2018","journal-title":"J. Hazard. Mater."},{"key":"ref_147","doi-asserted-by":"crossref","first-page":"103659","DOI":"10.1016\/j.jece.2020.103659","article-title":"Contemporary issues on the occurrence and removal of disinfection byproducts in drinking water\u2014A review","volume":"8","author":"Chaukura","year":"2020","journal-title":"J. Environ. Chem. Eng."},{"key":"ref_148","doi-asserted-by":"crossref","first-page":"103939","DOI":"10.1016\/j.jece.2020.103939","article-title":"To regulate or not to regulate? What to do with more toxic disinfection by-products?","volume":"8","author":"Richardson","year":"2020","journal-title":"J. Environ. Chem. Eng."},{"key":"ref_149","doi-asserted-by":"crossref","first-page":"133364","DOI":"10.1016\/j.chemosphere.2021.133364","article-title":"Effects of cast iron pipe corrosion on nitrogenous disinfection by-products formation in drinking water distribution systems via interaction among iron particles, biofilms, and chlorine","volume":"292","author":"Qi","year":"2022","journal-title":"Chemosphere"},{"key":"ref_150","doi-asserted-by":"crossref","first-page":"572","DOI":"10.1002\/j.1551-8833.1981.tb04801.x","article-title":"Siderite model of the formation of corrosion-resistant scales","volume":"73","author":"Sontheimer","year":"1981","journal-title":"J. Am. Water Works Assoc."},{"key":"ref_151","doi-asserted-by":"crossref","first-page":"593","DOI":"10.1016\/j.watres.2016.10.044","article-title":"Characteristics of iron corrosion scales and water quality variations in drinking water distribution systems of different pipe materials","volume":"106","author":"Li","year":"2016","journal-title":"Water Res."},{"key":"ref_152","doi-asserted-by":"crossref","first-page":"3215","DOI":"10.1016\/j.watres.2011.03.039","article-title":"Distribution of Asellus aquaticus and microinvertebrates in a non-chlorinated drinking water supply system\u2013Effects of pipe material and sedimentation","volume":"45","author":"Christensen","year":"2011","journal-title":"Water Res."},{"key":"ref_153","doi-asserted-by":"crossref","first-page":"1141","DOI":"10.1016\/j.chemosphere.2014.10.005","article-title":"Identification and characterization of steady and occluded water in drinking water distribution systems","volume":"119","author":"Tong","year":"2015","journal-title":"Chemosphere"},{"key":"ref_154","doi-asserted-by":"crossref","first-page":"2961","DOI":"10.1016\/S0043-1354(00)00591-1","article-title":"Physicochemical characteristics of corrosion scales in old iron pipes","volume":"35","author":"Sarin","year":"2001","journal-title":"Water Res."},{"key":"ref_155","doi-asserted-by":"crossref","unstructured":"Tong, H., Li, Z., Hu, X., Xu, W., and Li, Z. (2019). Metals in Occluded Water: A New Perspective for Pollution in Drinking Water Distribution Systems. Int. J. Environ. Res. Public Health, 16.","DOI":"10.3390\/ijerph16162849"},{"key":"ref_156","doi-asserted-by":"crossref","first-page":"129270","DOI":"10.1016\/j.chemosphere.2020.129270","article-title":"Co-release potential and human health risk of heavy metals from galvanized steel pipe scales under stagnation conditions of drinking water","volume":"267","author":"Tian","year":"2021","journal-title":"Chemosphere"},{"key":"ref_157","doi-asserted-by":"crossref","first-page":"452","DOI":"10.1016\/j.matpr.2021.11.291","article-title":"Improving mild steel corrosion resistance in tap water: Influence of water flow and supply rates","volume":"50","author":"Vasyliev","year":"2022","journal-title":"Mater. Today Proc."},{"key":"ref_158","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1016\/j.cemconres.2015.12.015","article-title":"Chloride-induced corrosion mechanism and rate of enamel- and epoxy-coated deformed steel bars embedded in mortar","volume":"82","author":"Tang","year":"2016","journal-title":"Cem. Concr. Res."},{"key":"ref_159","doi-asserted-by":"crossref","first-page":"102267","DOI":"10.1016\/j.scs.2020.102267","article-title":"The application of life cycle assessment for the optimization of pipe materials of building water supply and drainage system","volume":"60","author":"Xiong","year":"2020","journal-title":"Sustain. Cities Soc."},{"key":"ref_160","doi-asserted-by":"crossref","first-page":"371","DOI":"10.1016\/0048-9697(85)90343-2","article-title":"Characterization of low molecular weight products desorbed from polyethylene tubings","volume":"47","author":"Anselme","year":"1985","journal-title":"Sci. Total Environ."},{"key":"ref_161","doi-asserted-by":"crossref","first-page":"378","DOI":"10.1016\/j.polymertesting.2009.01.011","article-title":"Determination of the concentration profile and homogeneity of antioxidants and degradation products in a cross-linked polyethylene type A (PEXa) pipe","volume":"28","author":"Denberg","year":"2009","journal-title":"Polym. Test."},{"key":"ref_162","doi-asserted-by":"crossref","first-page":"117980","DOI":"10.1016\/j.watres.2021.117980","article-title":"Effects of pipe materials on the characteristic recognition, disinfection byproduct formation, and toxicity risk of pipe wall biofilms during chlorination in water supply pipelines","volume":"210","author":"Yan","year":"2022","journal-title":"Water Res."},{"key":"ref_163","unstructured":"Corfitzen, C.B. (2004). Investigation of Aftergrowth Potential of Polymers for Use in Drinking Water Distribution: Factors Affecting Migration of Bioavailable Compounds Investigated by Batch Set-Ups and Continuous Flow Model Systems, DTU Environment."},{"key":"ref_164","doi-asserted-by":"crossref","first-page":"269","DOI":"10.1016\/j.watres.2015.05.054","article-title":"Degradation of specific aromatic compounds migrating from PEX pipes into drinking water","volume":"81","author":"Ryssel","year":"2015","journal-title":"Water Res."},{"key":"ref_165","doi-asserted-by":"crossref","first-page":"483","DOI":"10.2166\/wh.2011.165","article-title":"Long-term study of migration of volatile organic compounds from cross-linked polyethylene (PEX) pipes and effects on drinking water quality","volume":"9","author":"Lund","year":"2011","journal-title":"J. Water Health"},{"key":"ref_166","doi-asserted-by":"crossref","first-page":"1006","DOI":"10.1016\/j.scitotenv.2018.12.127","article-title":"Iron stability on the inner wall of prepared polyethylene drinking pipe: Effects of multi-water quality factors","volume":"658","author":"Wang","year":"2019","journal-title":"Sci. Total Environ."},{"key":"ref_167","doi-asserted-by":"crossref","first-page":"100143","DOI":"10.1016\/j.wroa.2022.100143","article-title":"The interplay of suspended sediment concentration, particle size and fluid velocity on the rapid deposition of suspended iron oxide particles in PVC drinking water pipes","volume":"15","author":"Braga","year":"2022","journal-title":"Water Res. X"},{"key":"ref_168","doi-asserted-by":"crossref","first-page":"2720","DOI":"10.1016\/j.watres.2006.04.035","article-title":"Effect of PVC and iron materials on Mn(II) deposition in drinking water distribution systems","volume":"40","author":"Cerrato","year":"2006","journal-title":"Water Res."},{"key":"ref_169","doi-asserted-by":"crossref","first-page":"6902","DOI":"10.1021\/es201552x","article-title":"Predicting the Migration Rate of Dialkyl Organotins from PVC Pipe into Water","volume":"45","author":"Adams","year":"2011","journal-title":"Environ. Sci. Technol."},{"key":"ref_170","first-page":"263","article-title":"Migration of lead from unplasticized polyvinyl chloride pipes","volume":"B82","year":"2001","journal-title":"J. Hazard. Mater."},{"key":"ref_171","doi-asserted-by":"crossref","first-page":"2151","DOI":"10.1016\/j.watres.2006.04.010","article-title":"The effects of changing water flow velocity on the formation of biofilms and water quality in pilot distribution system consisting of copper or polyethylene pipes","volume":"40","author":"Lehtola","year":"2006","journal-title":"Water Res."},{"key":"ref_172","doi-asserted-by":"crossref","first-page":"1912","DOI":"10.1016\/S0043-1354(02)00576-6","article-title":"Volatile organic components migrating from plastic pipes (HDPE, PEX and PVC) into drinking water","volume":"37","author":"Skjevrak","year":"2003","journal-title":"Water Res."},{"key":"ref_173","doi-asserted-by":"crossref","first-page":"119480","DOI":"10.1016\/j.watres.2022.119480","article-title":"a A non-target screening study of high-density polyethylene pipes revealed rubber compounds as main contaminant in a drinking water distribution system","volume":"229","author":"Diera","year":"2023","journal-title":"Water Res."},{"key":"ref_174","doi-asserted-by":"crossref","first-page":"140135","DOI":"10.1016\/j.chemosphere.2023.140135","article-title":"Lead (Pb) deposition onto new and biofilm-laden potable water pipes","volume":"342","author":"Haddiuzaman","year":"2023","journal-title":"Chemosphere"},{"key":"ref_175","doi-asserted-by":"crossref","first-page":"132669","DOI":"10.1016\/j.chemosphere.2021.132669","article-title":"Degradation analysis of polymeric pipe materials used for water supply systems under various disinfectant conditions","volume":"291","author":"Khan","year":"2022","journal-title":"Chemosphere"},{"key":"ref_176","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1016\/j.tust.2015.04.013","article-title":"Laboratory evaluation of installation of a steel-reinforced high-density polyethylene pipe in soil","volume":"49","author":"Khatri","year":"2015","journal-title":"Tunn. Undergr. Space Technol."},{"key":"ref_177","doi-asserted-by":"crossref","first-page":"105750","DOI":"10.1016\/j.engfailanal.2021.105750","article-title":"Leakage analysis of steel wire reinforced polyethylene composite pipe used for waste water transportation","volume":"130","author":"Zhang","year":"2021","journal-title":"Eng. Fail Anal."},{"key":"ref_178","doi-asserted-by":"crossref","first-page":"149225","DOI":"10.1016\/j.scitotenv.2021.149225","article-title":"Characterizing the premise plumbing microbiome in both water and biofilms of a 50-year-old building","volume":"798","author":"Huang","year":"2021","journal-title":"Sci. Total Environ."},{"key":"ref_179","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1016\/j.watres.2017.03.031","article-title":"Potential impacts of changing supply-water quality on drinking water distribution: A review","volume":"116","author":"Liu","year":"2017","journal-title":"Water Res."},{"key":"ref_180","doi-asserted-by":"crossref","first-page":"150896","DOI":"10.1016\/j.scitotenv.2021.150896","article-title":"Effect of disinfectant exposure and starvation treatment on the detachment of simulated drinking water biofilms","volume":"807","author":"Chen","year":"2022","journal-title":"Sci. Total Environ."},{"key":"ref_181","doi-asserted-by":"crossref","first-page":"190","DOI":"10.1016\/j.ijheh.2010.05.003","article-title":"Integration of Pseudomonas aeruginosa and Legionella pneumophila in drinking water biofilms grown on domestic plumbing materials","volume":"213","author":"Moritz","year":"2010","journal-title":"Int. J. Hyg. Environ. Health"},{"key":"ref_182","doi-asserted-by":"crossref","first-page":"417","DOI":"10.1016\/j.ijheh.2011.05.009","article-title":"Biofilms in drinking water and their role as reservoir for pathogens","volume":"214","author":"Wingender","year":"2011","journal-title":"Int. J. Hyg. Environ. Health"},{"key":"ref_183","doi-asserted-by":"crossref","first-page":"115951","DOI":"10.1016\/j.watres.2020.115951","article-title":"Corroding copper and steel exposed to intermittently flowing tap water promote biofilm formation and growth of Legionella pneumophila","volume":"183","author":"Veenendaal","year":"2020","journal-title":"Water Res."},{"key":"ref_184","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1016\/j.watres.2017.12.013","article-title":"Pilot investigation on formation of 2,4,6-trichloroanisole via microbial O-methylation of 2,4,6-trichlorophenol in drinking water distribution system: An insight into microbial mechanism","volume":"131","author":"Zhang","year":"2018","journal-title":"Water Res."},{"key":"ref_185","doi-asserted-by":"crossref","first-page":"133218","DOI":"10.1016\/j.chemosphere.2021.133218","article-title":"Impact of pipe material and chlorination on the biofilm structure and microbial communities","volume":"289","author":"Zhang","year":"2022","journal-title":"Chemosphere"},{"key":"ref_186","doi-asserted-by":"crossref","first-page":"166","DOI":"10.1016\/j.engfailanal.2015.11.048","article-title":"Characteristics of corrosion scales and biofilm in aged pipe distribution systems with switching water source","volume":"60","author":"Li","year":"2016","journal-title":"Eng. Fail. Anal."},{"key":"ref_187","doi-asserted-by":"crossref","first-page":"116293","DOI":"10.1016\/j.envpol.2020.116293","article-title":"Characteristics of biostability of drinking water in aged pipes after water source switching: ATP evaluation, biofilms niches and microbial community transition","volume":"271","author":"Pan","year":"2021","journal-title":"Environ. Pollut."},{"key":"ref_188","doi-asserted-by":"crossref","first-page":"154940","DOI":"10.1016\/j.scitotenv.2022.154940","article-title":"Water and biofilm in drinking water distribution systems in the Netherlands","volume":"831","author":"Learbuch","year":"2022","journal-title":"Sci. Total Environ."},{"key":"ref_189","first-page":"2077","article-title":"Interaction between phosphorus and biodegradable organic carbon on drinking water biofilm subject to chlorination","volume":"108","author":"Park","year":"2010","journal-title":"J. Appl. Microbiol."},{"key":"ref_190","doi-asserted-by":"crossref","first-page":"1426","DOI":"10.1021\/es402636u","article-title":"Effect of disinfectant, water age, and pipe materials on bacterial and eukaryotic community structure in drinking water biofilm","volume":"48","author":"Wang","year":"2014","journal-title":"Environ. Sci. Technol."},{"key":"ref_191","doi-asserted-by":"crossref","first-page":"104476","DOI":"10.1016\/j.jece.2020.104476","article-title":"Biofilm growth on PVC and HDPE pipes impacts chlorine stability in the recycled water","volume":"8","author":"Trinh","year":"2020","journal-title":"J. Environ. Chem. Eng."},{"key":"ref_192","doi-asserted-by":"crossref","unstructured":"Liduino, V.S., Cravo-Laureau, C., Noel, C., Carbon, A., Duran, R., Lutterbach, M.T., and Camporese S\u00e9rvulo, E.F. (2019). Comparison of flow regimes on biocorrosion of steel pipe weldments: Community composition and diversity of biofilms. Int. Biodeterior. Biodegrad., 143.","DOI":"10.1016\/j.ibiod.2019.104717"},{"key":"ref_193","doi-asserted-by":"crossref","first-page":"116510","DOI":"10.1016\/j.jenvman.2022.116510","article-title":"Impacts of hydraulic conditions on microplastics biofilm development, shear stresses distribution, and microbial community structures in drinking water distribution pipes","volume":"325","author":"Chen","year":"2023","journal-title":"J. Environ. Manag."},{"key":"ref_194","doi-asserted-by":"crossref","first-page":"259","DOI":"10.1051\/metal\/2011063","article-title":"A long term study on biofilm development in drinking water distribution system: Comparison of stainless steel grades with commonly used materials","volume":"108","author":"Allion","year":"2011","journal-title":"Rev. M\u00e9tall."},{"key":"ref_195","doi-asserted-by":"crossref","first-page":"280","DOI":"10.1111\/1574-6941.12294","article-title":"Microbial diversities (16S and 18S rRNA gene pyrosequencing) and environmental pathogens within drinking water biofilms grown on the common premise plumbing materials unplasticized polyvinylchloride and copper","volume":"88","author":"Buse","year":"2014","journal-title":"FEMS Microbiol. Ecol."},{"key":"ref_196","doi-asserted-by":"crossref","first-page":"10713","DOI":"10.1007\/s00253-015-6885-6","article-title":"Pyrosequencing analysis of bacterial communities in biofilms from different pipe materials in a city drinking water distribution system of East China","volume":"99","author":"Ren","year":"2015","journal-title":"Appl. Microbiol. Biotechnol."},{"key":"ref_197","doi-asserted-by":"crossref","first-page":"142851","DOI":"10.1016\/j.scitotenv.2020.142851","article-title":"Occurrence and quantification of culturable and viable but non-culturable (VBNC) pathogens in biofilm on different pipes from a metropolitan drinking water distribution system","volume":"764","author":"Fu","year":"2021","journal-title":"Sci. Total Environ."},{"key":"ref_198","doi-asserted-by":"crossref","first-page":"110433","DOI":"10.1016\/j.envres.2020.110433","article-title":"Influence of pipe material on biofilm microbial communities found in drinking water supply system","volume":"196","author":"Goraj","year":"2021","journal-title":"Environ. Res."},{"key":"ref_199","doi-asserted-by":"crossref","first-page":"116922","DOI":"10.1016\/j.watres.2021.116922","article-title":"Influence of pipe materials on the microbial community in unchlorinated drinking water and biofilm","volume":"194","author":"Learbuch","year":"2021","journal-title":"Water Res."},{"key":"ref_200","doi-asserted-by":"crossref","unstructured":"Lee, D., Calendo, G., Kopec, K., Henry, R., Coutts, S., McCarthy, D., and Murphy, H.M. (2021). The Impact of Pipe Material on the Diversity of Microbial Communities in Drinking Water Distribution Systems. Front. Microbiol., 12.","DOI":"10.3389\/fmicb.2021.779016"},{"key":"ref_201","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1016\/j.procbio.2023.03.012","article-title":"Effect of domestic pipe materials on microbiological safety of drinking water: Different biofilm formation and chlorination resistance for diverse pipe materials","volume":"129","author":"Shan","year":"2023","journal-title":"Process Biochem."},{"key":"ref_202","doi-asserted-by":"crossref","first-page":"223","DOI":"10.1111\/j.1365-2672.1979.tb01748.x","article-title":"Dissolved oxygen utilization as an indicator of total microbial activity on non-metallic materials in contact with potable water","volume":"47","author":"Colbourne","year":"1979","journal-title":"J. Appl. Bacteriol."},{"key":"ref_203","unstructured":"DVGW (1999). Vermehrung von Mikroorganismen auf Werkstoffen fur den Trinkwasserbereich\u2014Pr\u00fcfung und Bewertung, DVGW. Technische Regeln Arbeitsblatt W270."},{"key":"ref_204","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1002\/j.1551-8833.1999.tb08568.x","article-title":"Maintaining quality without a disinfectant residual","volume":"91","author":"Schellart","year":"1999","journal-title":"J. Am. Water Works Assoc."},{"key":"ref_205","doi-asserted-by":"crossref","first-page":"431","DOI":"10.1007\/s11157-018-9473-2","article-title":"A review: Microbiologically influenced corrosion and the effect of cathodic polarization on typical bacteria","volume":"17","author":"Lv","year":"2018","journal-title":"Rev. Environ. Sci. Biotechnol."},{"key":"ref_206","doi-asserted-by":"crossref","first-page":"631","DOI":"10.1016\/j.jmst.2018.10.026","article-title":"Toward a better understanding of microbiologically influenced corrosion caused by sulfate reducing bacteria","volume":"35","author":"Gu","year":"2019","journal-title":"J. Mater. Sci. Technol."},{"key":"ref_207","doi-asserted-by":"crossref","first-page":"134652","DOI":"10.1016\/j.chemosphere.2022.134652","article-title":"Iron release and characteristics of corrosion scales and bacterial communities in drinking water supply pipes of different materials with varied nitrate concentrations","volume":"301","author":"Zhang","year":"2022","journal-title":"Chemosphere"},{"key":"ref_208","doi-asserted-by":"crossref","first-page":"124454","DOI":"10.1016\/j.conbuildmat.2021.124454","article-title":"Corrosion mechanism of nitrate reducing bacteria on X80 steel correlated to its intermediate metabolite nitrite","volume":"303","author":"Liu","year":"2021","journal-title":"Constr. Build. Mater."},{"key":"ref_209","doi-asserted-by":"crossref","first-page":"870","DOI":"10.1007\/s00284-017-1254-6","article-title":"The role of localized acidity generation in microbially influenced corrosion","volume":"74","author":"Kryachko","year":"2017","journal-title":"Curr. Microbiol."},{"key":"ref_210","doi-asserted-by":"crossref","first-page":"540","DOI":"10.1016\/j.corsci.2007.07.008","article-title":"Electrochemical behaviour of stainless steels in media containing iron-oxidizing bacteria (IOB) by corrosion process modeling","volume":"50","author":"Starosvetsky","year":"2008","journal-title":"Corros. Sci."},{"key":"ref_211","doi-asserted-by":"crossref","first-page":"2816","DOI":"10.1016\/j.corsci.2008.07.008","article-title":"Effect of biofilm on cast iron pipe corrosion in drinking water distribution system: Corrosion scales characterization and microbial community structure investigation","volume":"50","author":"Teng","year":"2008","journal-title":"Corros. Sci."},{"key":"ref_212","doi-asserted-by":"crossref","first-page":"1203","DOI":"10.1016\/S1001-0742(09)60239-4","article-title":"Bacteriological challenges to asbestos cement water distribution pipelines","volume":"22","author":"Wang","year":"2010","journal-title":"J. Environ. Sci."},{"key":"ref_213","doi-asserted-by":"crossref","first-page":"128694","DOI":"10.1016\/j.jhazmat.2022.128694","article-title":"The role of pipe biofilms on dissemination of viral pathogens and virulence factor genes in a full-scale drinking water supply system","volume":"432","author":"Miao","year":"2022","journal-title":"J. Hazard. Mater."},{"key":"ref_214","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1016\/j.cemconres.2015.06.011","article-title":"Microbiologically induced concrete corrosion: A case study from a combined sewer network","volume":"77","author":"Grengg","year":"2015","journal-title":"Cem. Concr. Res."},{"key":"ref_215","doi-asserted-by":"crossref","first-page":"698","DOI":"10.1016\/j.proeng.2016.08.229","article-title":"The Durability of a Concrete Sewer Pipeline Under Deterioration by Sulphate and Chloride Corrosion","volume":"153","author":"Sulikowski","year":"2016","journal-title":"Procedia Eng."},{"key":"ref_216","doi-asserted-by":"crossref","first-page":"810","DOI":"10.1016\/j.ibiod.2011.05.004","article-title":"Biodeterioration of asbestos cement (AC) pipe in drinking water distribution systems","volume":"65","author":"Wang","year":"2011","journal-title":"Int. Biodeterior. Biodegrad."},{"key":"ref_217","doi-asserted-by":"crossref","first-page":"127324","DOI":"10.1016\/j.jhazmat.2021.127324","article-title":"Field study on the characteristics of scales in damaged multi-material water supply pipelines: Insights into heavy metal and biological stability","volume":"424","author":"Jia","year":"2022","journal-title":"J. Hazard. Mater."},{"key":"ref_218","doi-asserted-by":"crossref","first-page":"362","DOI":"10.1016\/j.watres.2014.07.042","article-title":"Effects of microbial redox cycling of iron on cast iron pipe corrosion in drinking water distribution systems","volume":"65","author":"Wang","year":"2014","journal-title":"Water Res."},{"key":"ref_219","doi-asserted-by":"crossref","first-page":"331","DOI":"10.1016\/j.corsci.2014.10.028","article-title":"Characteristics of biofilms and iron corrosion scales with ground and surface waters in drinking water distribution systems","volume":"90","author":"Li","year":"2015","journal-title":"Corros. Sci."},{"key":"ref_220","doi-asserted-by":"crossref","first-page":"174","DOI":"10.1016\/j.watres.2014.04.035","article-title":"Characterization of biofilm and corrosion of cast iron pipes in drinking water distribution system with UV\/Cl2 disinfection","volume":"60","author":"Zhu","year":"2014","journal-title":"Water Res."},{"key":"ref_221","doi-asserted-by":"crossref","first-page":"484","DOI":"10.1016\/j.corsci.2015.08.023","article-title":"Corrosion behavior of carbon steel in the presence of sulfate reducing bacteria and iron oxidizing bacteria cultured in oilfeld produced water","volume":"100","author":"Liu","year":"2015","journal-title":"Corros. Sci."},{"key":"ref_222","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1016\/j.corsci.2015.09.023","article-title":"The effect of magnetic field on biomineralization and corrosion behavior of carbon steel induced by iron-oxidizing bacteria","volume":"102","author":"Liu","year":"2016","journal-title":"Corros. Sci."},{"key":"ref_223","doi-asserted-by":"crossref","first-page":"115","DOI":"10.4014\/jmb.1010.10012","article-title":"Effects of Diverse Water Pipe Materials on Bacterial Communities and Water Quality in the Annular Reactor","volume":"21","author":"Choi","year":"2011","journal-title":"J. Microbiol. Biotechnol."},{"key":"ref_224","doi-asserted-by":"crossref","first-page":"313","DOI":"10.1016\/j.watres.2019.05.024","article-title":"Disinfection byproduct formation during drinking water treatment and distribution: A review of unintended effects of engineering agents and materials","volume":"160","author":"Ding","year":"2019","journal-title":"Water Res."},{"key":"ref_225","doi-asserted-by":"crossref","first-page":"74","DOI":"10.1016\/j.watres.2018.04.058","article-title":"Succession of bacterial and fungal communities within biofilms of a chlorinated drinking water distribution system","volume":"141","author":"Douterelo","year":"2018","journal-title":"Water Res."},{"key":"ref_226","doi-asserted-by":"crossref","unstructured":"Ginige, M.P., Garbin, S., Wylie, J., and Krishna, K.C.B. (2017). Effectiveness of Devices to Monitor Biofouling and Metals Deposition on Plumbing Materials Exposed to a Full-Scale Drinking Water Distribution System. PLoS ONE, 12.","DOI":"10.1371\/journal.pone.0169140"},{"key":"ref_227","doi-asserted-by":"crossref","first-page":"908","DOI":"10.1111\/jam.12272","article-title":"Adherence and biofilm formation of Mycobacterium avium, Mycobacterium intracellulare and Mycobacterium abscessus to household plumbing materials","volume":"115","author":"Mullis","year":"2013","journal-title":"J. Appl. Microbiol."},{"key":"ref_228","doi-asserted-by":"crossref","first-page":"109150","DOI":"10.1016\/j.envres.2020.109150","article-title":"Formation of biofilms from new pipelines at both ends of the drinking water distribution system and comparison of disinfection by-products formation potential","volume":"182","author":"Chen","year":"2020","journal-title":"Environ. Res."},{"key":"ref_229","doi-asserted-by":"crossref","first-page":"1805","DOI":"10.1128\/aem.61.5.1805-1809.1995","article-title":"Precision and accuracy of recovery of legionella pneumophila from seeded tap water by filtration and centrifugation","volume":"61","author":"Boulanger","year":"1995","journal-title":"Appl. Environ. Microbiol."},{"key":"ref_230","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1016\/j.mcp.2015.05.011","article-title":"Viability-qPCR for detecting legionella: Comparison of two assays based on different amplicon lengths","volume":"29","author":"Ditommaso","year":"2015","journal-title":"Mol. Cell Probes."},{"key":"ref_231","doi-asserted-by":"crossref","unstructured":"Toplitsch, D., Platzer, S., Zehner, R., Maitz, S., Mascher, F., and Kittinger, C. (2021). Comparison of Updated Methods for Legionella Detection in Environmental Water Samples. Int. J. Environ. Res. Public Health, 18.","DOI":"10.3390\/ijerph18105436"},{"key":"ref_232","doi-asserted-by":"crossref","first-page":"1962","DOI":"10.1016\/j.watres.2005.03.009","article-title":"Pipeline materials modify the effectiveness of disinfectants in drinking water distribution systems","volume":"39","author":"Lehtola","year":"2005","journal-title":"Water Res."},{"key":"ref_233","doi-asserted-by":"crossref","first-page":"117736","DOI":"10.1016\/j.envpol.2021.117736","article-title":"Impacts of antibiotics on biofilm bacterial community and disinfection performance on simulated drinking water supply pipe wall","volume":"288","author":"Zhang","year":"2021","journal-title":"Environ. Pollut."},{"key":"ref_234","doi-asserted-by":"crossref","first-page":"368","DOI":"10.1016\/j.chemosphere.2018.03.143","article-title":"Impact of biofilm formation and detachment on the transmission of bacterial antibiotic resistance in drinking water distribution systems","volume":"203","author":"Zhang","year":"2018","journal-title":"Chemosphere"},{"key":"ref_235","doi-asserted-by":"crossref","first-page":"131048","DOI":"10.1016\/j.chemosphere.2021.131048","article-title":"The role of antibiotics and heavy metals on the development, promotion, and dissemination of antimicrobial resistance in drinking water biofilms","volume":"282","author":"Rilstone","year":"2021","journal-title":"Chemosphere"},{"key":"ref_236","doi-asserted-by":"crossref","first-page":"7673","DOI":"10.1007\/s00253-020-10777-8","article-title":"The impact of metal pipe materials, corrosion products, and corrosion inhibitors on antibiotic resistance in drinking water distribution systems","volume":"104","author":"Kimbell","year":"2020","journal-title":"Appl. Microbiol. Biotechnol."},{"key":"ref_237","doi-asserted-by":"crossref","first-page":"126493","DOI":"10.1016\/j.chemosphere.2020.126493","article-title":"Occurrence and identification of microplastics in tap water from China","volume":"252","author":"Tong","year":"2020","journal-title":"Chemosphere"},{"key":"ref_238","doi-asserted-by":"crossref","first-page":"70","DOI":"10.1016\/j.cotox.2021.09.003","article-title":"Microplastic pollution in drinking water","volume":"28","author":"Kirstein","year":"2021","journal-title":"Curr. Opin. Toxicol."},{"key":"ref_239","doi-asserted-by":"crossref","first-page":"44","DOI":"10.1016\/j.cofs.2021.02.011","article-title":"Microplastics in drinking water? Present state of knowledge and open questions","volume":"41","year":"2021","journal-title":"Curr. Opin. Food Sci."},{"key":"ref_240","doi-asserted-by":"crossref","first-page":"126612","DOI":"10.1016\/j.chemosphere.2020.126612","article-title":"Removal of microplastics via drinking water treatment: Current knowledge and future directions","volume":"251","author":"Shen","year":"2020","journal-title":"Chemosphere"},{"key":"ref_241","doi-asserted-by":"crossref","first-page":"102195","DOI":"10.1016\/j.jwpe.2021.102195","article-title":"Microplastic contamination in water supply and the removal efficiencies of the treatment plants: A case of Surabaya City, Indonesia","volume":"43","author":"Radityaningrum","year":"2021","journal-title":"J. Water Process. Eng."},{"key":"ref_242","doi-asserted-by":"crossref","first-page":"137848","DOI":"10.1016\/j.chemosphere.2023.137848","article-title":"Prevalence and implications of microplastics in potable water system: An update","volume":"317","author":"Menon","year":"2023","journal-title":"Chemosphere"},{"key":"ref_243","doi-asserted-by":"crossref","first-page":"161274","DOI":"10.1016\/j.scitotenv.2022.161274","article-title":"Occurrence of microplastics in tap and bottled water, and food packaging: A narrative review on current knowledge","volume":"865","author":"Muhib","year":"2023","journal-title":"Sci. Total Environ."},{"key":"ref_244","doi-asserted-by":"crossref","first-page":"162121","DOI":"10.1016\/j.scitotenv.2023.162121","article-title":"Tracking microplastics contamination in drinking water in Zahedan, Iran: From source to consumption taps","volume":"872","author":"Taghipour","year":"2023","journal-title":"Sci. Total Environ."},{"key":"ref_245","doi-asserted-by":"crossref","first-page":"304","DOI":"10.1016\/j.psep.2022.11.021","article-title":"Variation of microplastics and biofilm community characteristics along the long-distance raw water pipeline","volume":"169","author":"Tao","year":"2023","journal-title":"Process Saf. Environ. Prot."},{"key":"ref_246","doi-asserted-by":"crossref","first-page":"163270","DOI":"10.1016\/j.scitotenv.2023.163270","article-title":"Contamination and removal efficiency of microplastics and synthetic fibres in a conventional drinking water treatment plant in Geneva, Switzerland","volume":"880","author":"Zimmermann","year":"2023","journal-title":"Sci. Total Environ."},{"key":"ref_247","doi-asserted-by":"crossref","first-page":"143421","DOI":"10.1016\/j.scitotenv.2020.143421","article-title":"Investigation of microplastics contamination in drinking water of a German city","volume":"755","author":"Weber","year":"2021","journal-title":"Sci. Total Environ."},{"key":"ref_248","doi-asserted-by":"crossref","first-page":"114546","DOI":"10.1016\/j.marpolbul.2022.114546","article-title":"Microplastics toxicity, detection, and removal from water\/wastewater","volume":"187","author":"Adegoke","year":"2023","journal-title":"Mar. Pollut. Bull."},{"key":"ref_249","doi-asserted-by":"crossref","first-page":"147620","DOI":"10.1016\/j.scitotenv.2021.147620","article-title":"A critical review on the interactions of microplastics with heavy metals: Mechanism and their combined effect on organisms and humans","volume":"788","author":"Cao","year":"2021","journal-title":"Sci. Total Environ."},{"key":"ref_250","doi-asserted-by":"crossref","first-page":"109040","DOI":"10.1016\/j.jece.2022.109040","article-title":"Adsorption behavior of aged polystyrene microplastics (PSMPs) for manganese in water: Critical role of hydrated functional zone surrounding the microplastic surface","volume":"10","author":"He","year":"2022","journal-title":"J. Environ. Chem. Eng."},{"key":"ref_251","doi-asserted-by":"crossref","first-page":"121254","DOI":"10.1016\/j.envpol.2023.121254","article-title":"Effects of chlorination on microplastics pollution: Physicochemical transformation and chromium adsorption","volume":"323","author":"Miao","year":"2023","journal-title":"Environ. Pollut."},{"key":"ref_252","doi-asserted-by":"crossref","first-page":"115312","DOI":"10.1016\/j.envres.2023.115312","article-title":"A critical review on recent research progress on microplastic pollutants in drinking water","volume":"222","author":"Nirmala","year":"2023","journal-title":"Environ. Res."},{"key":"ref_253","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1016\/j.marchem.2014.06.001","article-title":"Interactions between trace metals and plastic production pellets under estuarine conditions","volume":"167","author":"Holmes","year":"2014","journal-title":"Mar. Chem."},{"key":"ref_254","doi-asserted-by":"crossref","first-page":"125115","DOI":"10.1016\/j.jhazmat.2021.125115","article-title":"Uptake of Pb(II) onto microplastic-associated biofilms in freshwater: Adsorption and combined toxicity in comparison to natural solid substrates","volume":"411","author":"Qi","year":"2021","journal-title":"J. Hazard. Mater."},{"key":"ref_255","doi-asserted-by":"crossref","first-page":"139237","DOI":"10.1016\/j.scitotenv.2020.139237","article-title":"Biofilm formation and its influences on the properties of microplastics as affected by exposure time and depth in the seawater","volume":"734","author":"Tu","year":"2020","journal-title":"Sci. Total Environ."},{"key":"ref_256","doi-asserted-by":"crossref","first-page":"600","DOI":"10.1016\/j.scitotenv.2019.04.331","article-title":"Biofilm facilitates metal accumulation onto microplastics in estuarine waters","volume":"683","author":"Richard","year":"2019","journal-title":"Sci. Total Environ."},{"key":"ref_257","doi-asserted-by":"crossref","first-page":"110118","DOI":"10.1016\/j.ecoenv.2019.110118","article-title":"Sorption properties of cadmium on microplastics: The common practice experiment and a two-dimensional correlation spectroscopic study","volume":"190","author":"Guo","year":"2020","journal-title":"Ecotoxicol. Environ. Saf."},{"key":"ref_258","doi-asserted-by":"crossref","first-page":"121960","DOI":"10.1016\/j.jhazmat.2019.121960","article-title":"Pb(II) uptake onto nylon microplastics: Interaction mechanism and adsorption performance","volume":"386","author":"Tang","year":"2020","journal-title":"J. Hazard. Mater."},{"key":"ref_259","doi-asserted-by":"crossref","first-page":"113440","DOI":"10.1016\/j.envpol.2019.113440","article-title":"The mechanism for adsorption of Cr(VI) ions by PE microplastics in ternary system of natural water environment","volume":"257","author":"Zhang","year":"2020","journal-title":"Environ. Pollut."},{"key":"ref_260","doi-asserted-by":"crossref","first-page":"272","DOI":"10.1016\/j.jes.2019.07.006","article-title":"The adsorption behavior of metals in aqueous solution by microplastics effected by UV radiation","volume":"87","author":"Wang","year":"2020","journal-title":"J. Environ. Sci."},{"key":"ref_261","doi-asserted-by":"crossref","first-page":"7301","DOI":"10.15666\/aeer\/1704_73017310","article-title":"Investigation of heavy metal adsorption on microplastics","volume":"17","author":"Oz","year":"2019","journal-title":"Appl. Ecol. Environ. Res."},{"key":"ref_262","doi-asserted-by":"crossref","first-page":"6001","DOI":"10.1051\/matecconf\/201825006001","article-title":"Sorptive behaviour of chromium on polyethylene microbeads in artificial seawater","volume":"250","author":"Zon","year":"2018","journal-title":"MATEC Web Conf."},{"key":"ref_263","doi-asserted-by":"crossref","first-page":"120238","DOI":"10.1016\/j.envpol.2022.120238","article-title":"Effects of microplastic sorption on microbial degradation of halogenated polycyclic aromatic hydrocarbons in water","volume":"313","author":"Sun","year":"2022","journal-title":"Environ. Pollut."},{"key":"ref_264","doi-asserted-by":"crossref","first-page":"118790","DOI":"10.1016\/j.watres.2022.118790","article-title":"Fate of microplastics in the drinking water production","volume":"221","author":"Bauerlein","year":"2022","journal-title":"Water Res."},{"key":"ref_265","doi-asserted-by":"crossref","first-page":"292","DOI":"10.1111\/wej.12766","article-title":"Microplastics throughout a tap water supply network","volume":"36","author":"Ferrer","year":"2022","journal-title":"Water Environ. J."},{"key":"ref_266","doi-asserted-by":"crossref","first-page":"129680","DOI":"10.1016\/j.jhazmat.2022.129680","article-title":"The effect of adsorption on the fate of colloidal polystyrene microplastics in drinking water distribution system pipe scales","volume":"439","author":"Chu","year":"2022","journal-title":"J. Hazard. Mater."},{"key":"ref_267","doi-asserted-by":"crossref","first-page":"150004","DOI":"10.1016\/j.scitotenv.2021.150004","article-title":"Occurrence and distribution of microplastics in water supply systems: In water and pipe scales","volume":"803","author":"Chu","year":"2022","journal-title":"Sci. Total Environ."},{"key":"ref_268","doi-asserted-by":"crossref","first-page":"1070","DOI":"10.1016\/j.watres.2011.12.001","article-title":"Effects of disinfectant and biofilm on the corrosion of cast iron pipes in a reclaimed water distribution system","volume":"46","author":"Wang","year":"2012","journal-title":"Water Res."},{"key":"ref_269","doi-asserted-by":"crossref","first-page":"112","DOI":"10.1016\/j.watres.2018.09.054","article-title":"Prioritization of unregulated disinfection by-products in drinking water distribution systems for human health risk mitigation: A critical review","volume":"147","author":"Mian","year":"2018","journal-title":"Water Res."},{"key":"ref_270","doi-asserted-by":"crossref","first-page":"04022022","DOI":"10.1061\/(ASCE)WR.1943-5452.0001562","article-title":"Examining the Longitudinal Dispersion of Solutes Inside Water Distribution Systems","volume":"148","author":"Abhijith","year":"2022","journal-title":"J. Water. Resour. Plan. Manag."},{"key":"ref_271","doi-asserted-by":"crossref","first-page":"121425","DOI":"10.1016\/j.jclepro.2020.121425","article-title":"Analysis of heavy metals leaching from internal pipe cement coating into potable water","volume":"265","author":"Bielski","year":"2020","journal-title":"J. Clean. Prod."},{"key":"ref_272","doi-asserted-by":"crossref","first-page":"1","DOI":"10.4186\/ej.2017.21.2.1","article-title":"Prediction of Asbestos Cement Water Pipe Aging and Pipe Prioritization using Monte Carlo Simulation","volume":"21","author":"Punurai","year":"2017","journal-title":"Eng. J."}],"container-title":["Polymers"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2073-4360\/15\/19\/3872\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T20:57:10Z","timestamp":1760129830000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2073-4360\/15\/19\/3872"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,9,24]]},"references-count":272,"journal-issue":{"issue":"19","published-online":{"date-parts":[[2023,10]]}},"alternative-id":["polym15193872"],"URL":"https:\/\/doi.org\/10.3390\/polym15193872","relation":{},"ISSN":["2073-4360"],"issn-type":[{"value":"2073-4360","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,9,24]]}}}