{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,8]],"date-time":"2026-10-08T18:02:20Z","timestamp":1791482540429,"version":"4.3.4"},"reference-count":29,"publisher":"MDPI AG","issue":"13","license":[{"start":{"date-parts":[[2024,7,8]],"date-time":"2024-07-08T00:00:00Z","timestamp":1720396800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"National Natural Science Foundation of China","award":["52077018"],"award-info":[{"award-number":["52077018"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Polymers"],"abstract":"<jats:p>Composite insulators have been widely used in power grids due to their excellent electrical-external-insulation performance. Long-term operation at high voltage levels accelerates the aging of composite insulators; however, there is a scarcity of research on aged composite insulators operating at 500 kV for over ten years. In this paper, the mechanical, electrical, and microscopic properties were tested on different sheds along a 500 kV composite insulator that had been running for 18 years. Additionally, the results were compared with a new insulator and the standards for live insulator operation. The results showed that the aging of the high-voltage end of composite insulators was the most serious. The results of the physical properties test indicated that the insulator\u2019s hardness was compliant but its tensile strength and break elongation did not meet standards. Under wet conditions, the pollution flashover voltage decreases by about 50% compared to the new insulator. Combined with the microscopic test results, the shed skeleton structure could be damaged and the filler might be lost during the aging process of polydimethylsiloxane (PDMS). The hardness of the insulator would increase by the precipitation of inorganic silicon; however, inorganic silicon might destroy the hydrophobicity and other properties of insulator sheds. These results can provide theoretical references for insulator life prediction and operation protection.<\/jats:p>","DOI":"10.3390\/polym16131944","type":"journal-article","created":{"date-parts":[[2024,7,8]],"date-time":"2024-07-08T04:52:49Z","timestamp":1720414369000},"page":"1944","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":9,"title":["Study on the Aging Characteristics of a \u00b1500 kV Composite Dead-End Insulator in Longtime Service"],"prefix":"10.3390","volume":"16","author":[{"given":"Zhijin","family":"Zhang","sequence":"first","affiliation":[{"name":"Xuefeng Mountain Energy Equipment Safety National Observation and Research Station, Chongqing University, Chongqing 400044, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bingbing","family":"Wang","sequence":"additional","affiliation":[{"name":"Xuefeng Mountain Energy Equipment Safety National Observation and Research Station, Chongqing University, Chongqing 400044, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xuze","family":"Li","sequence":"additional","affiliation":[{"name":"Xuefeng Mountain Energy Equipment Safety National Observation and Research Station, Chongqing University, Chongqing 400044, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shude","family":"Jing","sequence":"additional","affiliation":[{"name":"Xuefeng Mountain Energy Equipment Safety National Observation and Research Station, Chongqing University, Chongqing 400044, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuan","family":"Gao","sequence":"additional","affiliation":[{"name":"Xuefeng Mountain Energy Equipment Safety National Observation and Research Station, Chongqing University, Chongqing 400044, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dong","family":"Zeng","sequence":"additional","affiliation":[{"name":"Xuefeng Mountain Energy Equipment Safety National Observation and Research Station, Chongqing University, Chongqing 400044, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xingliang","family":"Jiang","sequence":"additional","affiliation":[{"name":"Xuefeng Mountain Energy Equipment Safety National Observation and Research Station, Chongqing University, Chongqing 400044, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2024,7,8]]},"reference":[{"key":"ref_1","first-page":"2888","article-title":"Rapid development of silicone rubber composite insulator in China","volume":"42","author":"Liang","year":"2016","journal-title":"High Volt. Eng."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"4132","DOI":"10.1049\/gtd2.12584","article-title":"Study on decay-like fracture of 500 kV composite insulators: Infrared, ultraviolet and electric field distribution detection","volume":"16","author":"Zhang","year":"2022","journal-title":"IET Gener. Transm. Distrib."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"122","DOI":"10.1049\/hve.2016.0034","article-title":"Progress in and prospects for electrical insulating materials","volume":"1","author":"Li","year":"2016","journal-title":"High Volt."},{"key":"ref_4","doi-asserted-by":"crossref","unstructured":"Zhang, H., Tu, Y., Lu, Y., Xu, Z., Chen, C., and Xie, L. (2012, January 10\u201313). Study on aging characteristics of silicone rubber insulator sheds using FTIR. Proceedings of the 2012 IEEE International Symposium on Electrical Insulation, San Juan, PR, USA.","DOI":"10.1109\/ELINSL.2012.6251431"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"130","DOI":"10.1109\/TDEI.2007.302881","article-title":"Aging of silicone rubber composite insulators on 400 kV transmission lines","volume":"14","author":"Rowland","year":"2007","journal-title":"IEEE Trans. Dielectr. Electr. Insul."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"2437","DOI":"10.1016\/S0196-8904(01)00174-1","article-title":"Effect of desert environmental conditions on the flashover voltage of insulators","volume":"43","author":"Hamza","year":"2002","journal-title":"Energy Convers. Manag."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"1068","DOI":"10.1109\/TDEI.2017.006386","article-title":"Mechanism of saline deposition and surface flashover on outdoor insulators near coastal areas part II. impact of various environment stresses","volume":"24","author":"Hussain","year":"2017","journal-title":"IEEE Trans. Dielectr. Electr. Insul."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"490","DOI":"10.1109\/TDEI.2016.006077","article-title":"Evaluation of field-ageing effects on insulating materials of composite suspension insulators","volume":"24","author":"Mavrikakis","year":"2017","journal-title":"IEEE Trans. Dielectr. Electr. Insul."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"38849","DOI":"10.1109\/ACCESS.2024.3375399","article-title":"Intensification of electric field stresses in field aged 380-kV composite insulators due to loss of hydrophobicity","volume":"12","author":"Asif","year":"2024","journal-title":"IEEE Access"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"1630","DOI":"10.1109\/TDEI.2015.7116359","article-title":"Aging characteristic at different depths in a single composite insulators shed","volume":"22","author":"Zhou","year":"2015","journal-title":"IEEE Trans. Dielectr. Electr. Insul."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"66714","DOI":"10.1109\/ACCESS.2019.2917700","article-title":"Characterization of silicone rubber degradation under salt-fog environment with AC test voltage","volume":"7","author":"Zhang","year":"2019","journal-title":"IEEE Access"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"16889","DOI":"10.1038\/s41598-023-35701-8","article-title":"Study on material and mechanical characteristics of silicone rubber shed of field-aged 110kV composite insulators","volume":"13","author":"Mu","year":"2023","journal-title":"Sci. Rep."},{"key":"ref_13","first-page":"2831","article-title":"Comparative experimental study on corona aging characteristics effect of nano composite RTV and HTV","volume":"43","author":"Yao","year":"2017","journal-title":"High Volt. Eng."},{"key":"ref_14","first-page":"4083","article-title":"Corona aging characteristics of composite insulators based on orthogonal experiment","volume":"44","author":"Liang","year":"2018","journal-title":"High Volt. Eng."},{"key":"ref_15","first-page":"2309","article-title":"Influence of trap on flashover voltage of silicone rubber after corona aging","volume":"43","author":"Liang","year":"2017","journal-title":"High Volt. Eng."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"95553","DOI":"10.1109\/ACCESS.2022.3203473","article-title":"Mechanical properties of high-temperature vulcanized silicone rubber under acid-fog with AC energized","volume":"10","author":"Zhang","year":"2022","journal-title":"IEEE Access"},{"key":"ref_17","first-page":"94","article-title":"Effect of fog water conductivity on AC fog flashover characteristics of FXBW-35\/70 composite insulator","volume":"53","author":"Liang","year":"2017","journal-title":"High Volt. Appar."},{"key":"ref_18","first-page":"433","article-title":"Flashover characteristics of post insulators under fog and haze conditions","volume":"45","author":"Wang","year":"2019","journal-title":"High Volt. Eng."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"164292","DOI":"10.1109\/ACCESS.2020.3022521","article-title":"Performance evaluation of 230 kV polymer insulators in the coastal area of Saudi Arabia","volume":"8","author":"Maraaba","year":"2020","journal-title":"IEEE Access"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"105679","DOI":"10.1016\/j.ijepes.2019.105679","article-title":"Reliability assessment of aged SiR insulators under humidity and pollution conditions","volume":"117","author":"Mirzaie","year":"2020","journal-title":"Int. J. Electr. Power Energy Syst."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"488","DOI":"10.1016\/j.ijepes.2013.05.023","article-title":"Reliability of directly-molded polymer surge arresters. degradation by immersion test versus electrical performance","volume":"53","author":"Antonionni","year":"2013","journal-title":"Int. J. Electr. Power Energy Syst."},{"key":"ref_22","unstructured":"(2009). Geometrical Product Specifications (GPS) Surface texture: Profile method-Surface Roughness Parameters and Their Values (Standard No. GB\/T 1031-2009)."},{"key":"ref_23","unstructured":"(2008). Rubber, Vulcanized or Thermoplastic Determination of Indentation Hardness Part 1: Duromerer Method (Shore hardness) (Standard No. ISO 7619-1)."},{"key":"ref_24","unstructured":"(2012). Technical Specification for Long Rod Composite Insulators with a Nominal Voltage of \u00b1500 kV DC and Above (Standard No. DL\/T 810-2012)."},{"key":"ref_25","unstructured":"(2009). Rubber, Vulcanized or Thermoplastic Determination of Tensile Stress-Strain Properties (Standard No. ISO 37-2005)."},{"key":"ref_26","unstructured":"(1996). Environmental Pollution Classification and External Insulation Selection for High Voltage Transmission Line, Power Plant and Substation (Standard No. GB\/T 16434-1996)."},{"key":"ref_27","unstructured":"(2013). Electrical Strength of Insulating Materials-Test Methods Part 1: Tests at Power Frequencies (Standard No. IEC 60243-1)."},{"key":"ref_28","unstructured":"(2004). Application Guide of Composite Insulators for AC Overhand Lines with a Nominal Voltage over 1000 V (Standard No. DL\/T 864-2004)."},{"key":"ref_29","unstructured":"(2005). Rubber, Vulcanized\u2014Determination of Electrical Breakdown Strength and Voltage Resistant at Commercial Power Frequency (Standard No. GB\/T 1695-2005)."}],"container-title":["Polymers"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2073-4360\/16\/13\/1944\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T15:11:31Z","timestamp":1760109091000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2073-4360\/16\/13\/1944"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,7,8]]},"references-count":29,"journal-issue":{"issue":"13","published-online":{"date-parts":[[2024,7]]}},"alternative-id":["polym16131944"],"URL":"https:\/\/doi.org\/10.3390\/polym16131944","relation":{},"ISSN":["2073-4360"],"issn-type":[{"value":"2073-4360","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,7,8]]}}}