{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,17]],"date-time":"2026-09-17T09:02:57Z","timestamp":1789635777429,"version":"4.0.0"},"reference-count":56,"publisher":"MDPI AG","issue":"18","license":[{"start":{"date-parts":[[2026,9,17]],"date-time":"2026-09-17T00:00:00Z","timestamp":1789603200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Polymers"],"abstract":"<jats:p>Inorganic fillers are incorporated into polyetheretherketone (PEEK) to enhance mechanical performance, yet their long-term stability in chromogenic media remains insufficiently explored. This study evaluated the color stability, surface roughness, and chemical changes in modified PEEK variants following coffee thermal cycling. In this study, four PEEK materials were tested: unfilled (P), glass fiber-reinforced (GFP), nanoceramic-filled (CR), and titanium dioxide-filled (TP). A total of 40 disk-shaped specimens (10 \u00d7 2 mm, n = 10) were prepared and subjected to 30,000 cycles (5\u201355 \u00b0C) in coffee. Color differences (\u0394E) after 5000 and 30,000 cycles, roughness changes (\u0394Ra), and chemical alterations via qualitative Fourier-transform infrared (FTIR) spectroscopy were evaluated. Thermal cycling significantly affected all materials (p &lt; 0.05). TP demonstrated superior stability with the lowest roughness increase (\u0394Ra = 0.017 \u00b1 0.003 \u03bcm) and minimal discoloration (\u0394E = 1.66 \u00b1 0.25), remaining within the clinically acceptable threshold (\u0394E &lt; 3.3). Conversely, GFP showed the greatest degradation (\u0394Ra = 0.133 \u00b1 0.008 \u03bcm; \u0394E = 8.45 \u00b1 0.34). FTIR confirmed no chemical backbone cleavage across groups. Filler type significantly dictates thermochemical resistance in PEEK. While titanium dioxide reinforcement preserves surface smoothness and color stability under in vitro aging, glass fiber reinforcement markedly accelerates staining and roughening. This study highlights the necessity of considering hydrothermal aging resistance and microstructural filler stability when selecting PEEK biomaterials for long-term clinical restorations.<\/jats:p>","DOI":"10.3390\/polym18182264","type":"journal-article","created":{"date-parts":[[2026,9,17]],"date-time":"2026-09-17T08:03:17Z","timestamp":1789632197000},"page":"2264","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Evaluation of Surface Roughness, Color Stability, and FTIR Characterization of Different Inorganic-Filled PEEK Materials After Coffee Thermal Cycling"],"prefix":"10.3390","volume":"18","author":[{"ORCID":"https:\/\/orcid.org\/0009-0009-2623-241X","authenticated-orcid":false,"given":"Aybike","family":"Cengiz Da\u011ftekin","sequence":"first","affiliation":[{"name":"Department of Prosthodontics, Faculty of Dentistry, F\u0131rat University, 23119 Elazig, T\u00fcrkiye"}],"role":[{"vocabulary":"crossref","role":"author"},{"role":"conceptualization","vocabulary":"credit"},{"role":"methodology","vocabulary":"credit"},{"role":"software","vocabulary":"credit"},{"role":"resources","vocabulary":"credit"},{"role":"visualization","vocabulary":"credit"},{"role":"investigation","vocabulary":"credit"},{"role":"formal-analysis","vocabulary":"credit"},{"role":"writing-original-draft","vocabulary":"credit"},{"role":"project-administration","vocabulary":"credit"},{"role":"funding-acquisition","vocabulary":"credit"},{"role":"writing-review-editing","vocabulary":"credit"},{"role":"validation","vocabulary":"credit"},{"role":"data-curation","vocabulary":"credit"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8883-8307","authenticated-orcid":false,"given":"Samet","family":"Tekin","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics, Faculty of Dentistry, F\u0131rat University, 23119 Elazig, T\u00fcrkiye"}],"role":[{"vocabulary":"crossref","role":"author"},{"role":"conceptualization","vocabulary":"credit"},{"role":"methodology","vocabulary":"credit"},{"role":"software","vocabulary":"credit"},{"role":"validation","vocabulary":"credit"},{"role":"formal-analysis","vocabulary":"credit"},{"role":"investigation","vocabulary":"credit"},{"role":"resources","vocabulary":"credit"},{"role":"writing-review-editing","vocabulary":"credit"},{"role":"supervision","vocabulary":"credit"},{"role":"project-administration","vocabulary":"credit"},{"role":"funding-acquisition","vocabulary":"credit"}]}],"member":"1968","published-online":{"date-parts":[[2026,9,17]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"1191","DOI":"10.1007\/s00784-016-1892-2","article-title":"Discoloration of PMMA, composite, and PEEK","volume":"21","author":"Heimer","year":"2017","journal-title":"Clin. Oral Investig."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"598","DOI":"10.1016\/j.prosdent.2018.06.005","article-title":"Antagonist enamel wear of tooth-supported monolithic zirconia posterior crowns in vivo: A systematic review","volume":"121","author":"Gou","year":"2019","journal-title":"J. Prosthet. Dent."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"e869","DOI":"10.1002\/cre2.869","article-title":"Effect of various staining beverages on the color stability of CAD\/CAM PMMA denture teeth: An in vitro study","volume":"10","author":"Alouch","year":"2024","journal-title":"Clin. Exp. Dent. Res."},{"key":"ref_4","doi-asserted-by":"crossref","unstructured":"Abhay, S.S., Ganapathy, D., Veeraiyan, D.N., Ariga, P., Heboyan, A., Amornvit, P., Rokaya, D., and Srimaneepong, V. (2021). Wear resistance, color stability and displacement resistance of milled PEEK crowns compared to zirconia crowns under stimulated chewing and high-performance aging. Polymers, 13.","DOI":"10.3390\/polym13213761"},{"key":"ref_5","doi-asserted-by":"crossref","unstructured":"Marchesi, G., Camurri Piloni, A., Nicolin, V., Turco, G., and Di Lenarda, R. (2021). Chairside CAD\/CAM materials: Current trends of clinical uses. Biology, 10.","DOI":"10.3390\/biology10111170"},{"key":"ref_6","first-page":"CD009606","article-title":"Metal-free materials for fixed prosthodontic restorations","volume":"12","author":"Poggio","year":"2017","journal-title":"Cochrane Database Syst. Rev."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"E254","DOI":"10.2341\/18-146-L","article-title":"Effect of thermocycling on biaxial flexural strength of CAD\/CAM, bulk fill, and conventional resin composite materials","volume":"44","author":"Jalkh","year":"2019","journal-title":"Oper. Dent."},{"key":"ref_8","doi-asserted-by":"crossref","unstructured":"Ate\u015f, G., and Gungormus, M. (2026). Effects of Thermal Aging on Optical, Surface, Mechanical, and Biological Properties of CAD\/CAM Polymer-Based Dental Materials. Polymers, 18.","DOI":"10.3390\/polym18060760"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"1377","DOI":"10.1016\/j.dental.2015.08.151","article-title":"Flexural behavior of PEEK materials for dental application","volume":"31","author":"Schwitalla","year":"2015","journal-title":"Dent. Mater."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"419","DOI":"10.1016\/j.prosdent.2016.06.016","article-title":"Surface properties of polyetheretherketone after different laboratory and chairside polishing protocols","volume":"117","author":"Heimer","year":"2017","journal-title":"J. Prosthet. Dent."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"e64","DOI":"10.1016\/j.jdent.2012.07.005","article-title":"The effects of finishing and polishing techniques on surface roughness and color stability of nanocomposites","volume":"40","year":"2012","journal-title":"J. Dent."},{"key":"ref_12","doi-asserted-by":"crossref","unstructured":"Porojan, L., Toma, F.R., Vasiliu, R.D., Topal\u0103, F.-I., Porojan, S.D., and Matichescu, A. (2021). Optical properties and color stability of dental PEEK related to artificial ageing and staining. Polymers, 13.","DOI":"10.3390\/polym13234102"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"e918","DOI":"10.1002\/cre2.918","article-title":"Effect of coffee thermocycling on color stability and translucency of CAD-CAM polychromatic high translucent zirconia compared with lithium disilicate glass ceramic","volume":"10","author":"Khomprang","year":"2024","journal-title":"Clin. Exp. Dent. Res."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"347","DOI":"10.1016\/j.prosdent.2018.03.001","article-title":"Optical properties and surface roughness of prepolymerized poly (methyl methacrylate) denture base materials","volume":"121","author":"Alp","year":"2019","journal-title":"J. Prosthet. Dent."},{"key":"ref_15","doi-asserted-by":"crossref","unstructured":"Cengiz Da\u011ftekin, A., and Tekin, S. (2026). Effect of Beverages on the Surface Roughness and Staining of Modified Polyetheretherketone (PEEK) Materials. Polymers, 18.","DOI":"10.3390\/polym18121548"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1002\/jbm.b.34890","article-title":"Biomechanical analyses of one-piece dental implants composed of titanium, zirconia, PEEK, CFR-PEEK, or GFR-PEEK: Stresses, strains, and bone remodeling prediction by the finite element method","volume":"110","author":"Fabris","year":"2022","journal-title":"J. Biomed. Mater. Res. Part B Appl. Biomater."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"225","DOI":"10.1016\/j.jmbbm.2018.05.008","article-title":"Influence of laser structuring of PEEK, PEEK-GF30 and PEEK-CF30 surfaces on the shear bond strength to a resin cement","volume":"84","author":"Henriques","year":"2018","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"ref_18","unstructured":"(1997). Geometrical Product Specifications (GPS)\u2014Surface Texture: Profile Method\u2014Terms, Definitions and Surface Texture Parameters (Standard No. ISO 4287:1997)."},{"key":"ref_19","unstructured":"(1994). Dental Materials\u2014Guidance on Testing of Adhesion to Tooth Structure (Standard No. ISO\/TR 11405:1994)."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"467","DOI":"10.1111\/jopr.13730","article-title":"Influence of polishing technique and coffee thermal cycling on the surface roughness and color stability of additively and subtractively manufactured resins used for definitive restorations","volume":"33","author":"Akay","year":"2024","journal-title":"J. Prosthodont."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1016\/j.prosdent.2015.06.014","article-title":"Color stainability of CAD\/CAM and nanocomposite resin materials","volume":"115","author":"Acar","year":"2016","journal-title":"J. Prosthet. Dent."},{"key":"ref_22","first-page":"224.e221","article-title":"Effect of surface finishing, coffee thermal cycling, and repolishing on the optical properties of lithium disilicate-based CAD-CAM glass-ceramics","volume":"134","year":"2025","journal-title":"J. Prosthet. Dent."},{"key":"ref_23","doi-asserted-by":"crossref","unstructured":"\u017divkovi\u0107, N., Vukovi\u0107, M., Tomi\u0107, M., Mitri\u0107, J., Gnjato, S., Opa\u010di\u0107-Gali\u0107, V., Mili\u0107 Lemi\u0107, A., Mancic, L., and Savi\u0107-Stankovi\u0107, T. (2026). Effects of Thermocycling and Staining on Optical Behavior of Light-Cured and Digital Light-Processed Dental Composites. J. Compos. Sci., 10.","DOI":"10.3390\/jcs10080402"},{"key":"ref_24","doi-asserted-by":"crossref","unstructured":"\u017divkovi\u0107, N., Vukovi\u0107, M., Tomi\u0107, M., Vulovi\u0107, S., Nedi\u0107, S., Mitri\u0107, J., Mili\u0107 Lemi\u0107, A., and Mancic, L. (2026). Processing-Dependent Aging Behavior of Dental Resins: Impact on Color Stability and Translucency. Processes, 14.","DOI":"10.3390\/pr14091359"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"89","DOI":"10.1016\/S0300-5712(98)00037-2","article-title":"Thermal cycling procedures for laboratory testing of dental restorations","volume":"27","author":"Gale","year":"1999","journal-title":"J. Dent."},{"key":"ref_26","first-page":"e48189","article-title":"Evaluation and assessment of the colour stability of modified polymethyl methacrylate denture base materials and polyether ether ketone in a cast partial denture framework: An in-vitro study","volume":"15","author":"Joshua","year":"2023","journal-title":"Cureus"},{"key":"ref_27","doi-asserted-by":"crossref","unstructured":"\u0160imunovi\u0107, L., \u010cekalovi\u0107 Agovi\u0107, S., Mari\u0107, A.J., Ba\u010di\u0107, I., Klari\u0107, E., Uribe, F., and Me\u0161trovi\u0107, S. (2024). Color and chemical stability of 3D-printed and thermoformed polyurethane-based aligners. Polymers, 16.","DOI":"10.3390\/polym16081067"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"258","DOI":"10.1016\/S0109-5641(97)80038-3","article-title":"Comparison of surface roughness of oral hard materials to the threshold surface roughness for bacterial plaque retention: A review of the literature","volume":"13","author":"Bollenl","year":"1997","journal-title":"Dent. Mater."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1111\/jopr.13815","article-title":"Flexural strength, surface roughness, and biofilm formation of ceramic-reinforced PEEK: An in vitro comparative study","volume":"34","author":"Almogbel","year":"2025","journal-title":"J. Prosthodont."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"952","DOI":"10.1016\/j.jmapro.2025.12.039","article-title":"Effects of short glass fibre reinforcement on the machinability of PEEK polymer based on cutting force monitoring and geometric control","volume":"157","author":"Caminero","year":"2026","journal-title":"J. Manuf. Process."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"221","DOI":"10.1016\/j.matpr.2022.10.174","article-title":"Surface roughness and color changes of dental PEEK related to staining beverages and cleaning methods","volume":"78","author":"Porojan","year":"2023","journal-title":"Mater. Today Proc."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"584","DOI":"10.1016\/j.prosdent.2016.02.006","article-title":"Two-body wear performance of dental colored zirconia after different surface treatments","volume":"116","author":"Bai","year":"2016","journal-title":"J. Prosthet. Dent."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"104917","DOI":"10.1016\/j.jdent.2024.104917","article-title":"Effect of aging and bleaching on the color stability and surface roughness of a recently introduced single-shade composite resin","volume":"143","author":"Chen","year":"2024","journal-title":"J. Dent."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"2451","DOI":"10.21608\/edj.2024.272943.2957","article-title":"Effect of commonly consumed beverages on color stability of hybrid ceramics: An in vitro study","volume":"70","author":"Abdelhafez","year":"2024","journal-title":"Egypt. Dent. J."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"160","DOI":"10.1016\/j.prosdent.2018.09.011","article-title":"In vitro color stainability and relative translucency of CAD-CAM restorative materials used for laminate veneers and complete crowns","volume":"122","author":"Arif","year":"2019","journal-title":"J. Prosthet. Dent."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"325","DOI":"10.1016\/j.prosdent.2019.01.009","article-title":"Discoloration and translucency changes of CAD-CAM materials after exposure to beverages","volume":"122","author":"Bilgili","year":"2019","journal-title":"J. Prosthet. Dent."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"104993","DOI":"10.1016\/j.jmbbm.2021.104993","article-title":"Effect of post-curing time on the color stability and related properties of a tooth-colored 3D-printed resin material","volume":"126","author":"Lee","year":"2022","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"969.e1","DOI":"10.1016\/j.prosdent.2024.01.021","article-title":"Effect of coffee thermocycling on the color and translucency of milled and 3D printed definitive restoration materials","volume":"131","author":"Ismatullaev","year":"2024","journal-title":"J. Prosthet. Dent."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1016\/j.prosdent.2017.10.024","article-title":"Effect of surface treatments and coffee thermocycling on the color and translucency of CAD-CAM monolithic glass-ceramic","volume":"120","author":"Alp","year":"2018","journal-title":"J. Prosthet. Dent."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"364","DOI":"10.2174\/1874210601913010364","article-title":"Influence of the Arabic-coffee on the overall color of glazed or polished porcelain veneers\u2013in vitro study","volume":"13","author":"Alghazali","year":"2019","journal-title":"Open Dent. J."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1111\/jopr.13360","article-title":"Effect of staining solutions on color stability, gloss and surface roughness of removable partial dental prosthetic polymers","volume":"31","author":"Papathanasiou","year":"2022","journal-title":"J. Prosthodont."},{"key":"ref_42","doi-asserted-by":"crossref","unstructured":"Porojan, L., Toma, F.R., B\u00eerdeanu, M.I., Vasiliu, R.D., U\u021bu, I.-D., and Matichescu, A. (2022). Surface characteristics and color stability of dental PEEK related to water saturation and thermal cycling. Polymers, 14.","DOI":"10.3390\/polym14112144"},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"1202","DOI":"10.1016\/j.dental.2021.04.009","article-title":"The effect of different storage media on the monomer elution and hardness of CAD\/CAM composite blocks","volume":"37","author":"Alamoush","year":"2021","journal-title":"Dent. Mater."},{"key":"ref_44","doi-asserted-by":"crossref","unstructured":"Basiony, M.Z., Selima, R.A., Rady, N.A., and Hamid, S.M.A. (2026). Evaluation of thermocycling, color stability, surface roughness and hardness of nanocarbon HPP, BioHPP and PEEK used for fabrication of prosthetic restorations (in vitro study). BMC Oral Health, 26.","DOI":"10.1186\/s12903-026-09615-6"},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1016\/j.jpor.2015.10.001","article-title":"Applications of polyetheretherketone (PEEK) in oral implantology and prosthodontics","volume":"60","author":"Najeeb","year":"2016","journal-title":"J. Prosthodont. Res."},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"5","DOI":"10.25122\/jml-2019-0003","article-title":"The role of polyether ether ketone (PEEK) in dentistry\u2014A review","volume":"12","author":"Bathala","year":"2019","journal-title":"J. Med. Life"},{"key":"ref_47","first-page":"19","article-title":"A review of PEEK polymer\u2019s properties and its use in prosthodontics","volume":"19","author":"Skirbutis","year":"2017","journal-title":"Stomatologija"},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"108470","DOI":"10.1016\/j.compositesa.2024.108470","article-title":"3D printing of high-stiffness and high-strength glass fiber reinforced PEEK composites by selective laser sintering","volume":"187","author":"Tang","year":"2024","journal-title":"Compos. Part A Appl. Sci. Manuf."},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"394","DOI":"10.1016\/j.dental.2017.01.010","article-title":"Effect of monomer type on the CC degree of conversion, water sorption and solubility, and color stability of model dental composites","volume":"33","author":"Fonseca","year":"2017","journal-title":"Dent. Mater."},{"key":"ref_50","doi-asserted-by":"crossref","unstructured":"Lu, W.-J., Chen, W.-C., Srimaneepong, V., Chen, C.-S., Huang, C.-H., Lin, H.-C., Tung, O.-H., and Huang, H.-H. (2023). Fracture characteristics of commercial PEEK dental crowns: Combining the effects of aging time and TiO2 content. Polymers, 15.","DOI":"10.3390\/polym15122720"},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1007\/s10266-024-00953-x","article-title":"Effects of pre-heating on physical\u2013mechanical\u2013chemical properties of contemporary resin composites","volume":"113","author":"Bueno","year":"2025","journal-title":"Odontology"},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"S1","DOI":"10.1111\/jerd.12149","article-title":"Color difference thresholds in dentistry","volume":"27","author":"Paravina","year":"2015","journal-title":"J. Esthet. Restor. Dent."},{"key":"ref_53","doi-asserted-by":"crossref","unstructured":"Ding, L., Lu, W., Zhang, J., Yang, C., and Wu, G. (2021). Preparation and Performance Evaluation of Duotone 3D-Printed Polyetheretherketone as Oral Prosthetic Materials: A Proof-of-Concept Study. Polymers, 13.","DOI":"10.3390\/polym13121949"},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"115","DOI":"10.4047\/jap.2024.16.2.115","article-title":"Comparison of fracture strength, surface hardness, and color stain of conventionally fabricated, 3D printed, and CAD-CAM milled interim prosthodontic materials after thermocycling","volume":"16","author":"Aykent","year":"2024","journal-title":"J. Adv. Prosthodont."},{"key":"ref_55","doi-asserted-by":"crossref","unstructured":"Oyar, P., and Ulusoy, M. (2024). Effect of milling procedures in CAD-CAM systems on the color changes of CAD-CAM polymethyl methacrylate resin material as interim material. BMC Oral Health, 24.","DOI":"10.1186\/s12903-024-04350-2"},{"key":"ref_56","doi-asserted-by":"crossref","first-page":"930","DOI":"10.5005\/jp-journals-10024-3767","article-title":"Comparative Evaluation of Surface Roughness and Color Stability of Polyetheretherketone with Conventional Interim Prosthetic Materials: An In Vitro Study","volume":"25","author":"Saraswathy","year":"2025","journal-title":"J. Contemp. Dent. Pract."}],"container-title":["Polymers"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2073-4360\/18\/18\/2264\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,17]],"date-time":"2026-09-17T08:20:08Z","timestamp":1789633208000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2073-4360\/18\/18\/2264"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,17]]},"references-count":56,"journal-issue":{"issue":"18","published-online":{"date-parts":[[2026,9]]}},"alternative-id":["polym18182264"],"URL":"https:\/\/doi.org\/10.3390\/polym18182264","relation":{},"ISSN":["2073-4360"],"issn-type":[{"value":"2073-4360","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,17]]}}}