{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,10]],"date-time":"2026-04-10T17:59:52Z","timestamp":1775843992546,"version":"3.50.1"},"reference-count":18,"publisher":"MDPI AG","issue":"2","license":[{"start":{"date-parts":[[2026,4,10]],"date-time":"2026-04-10T00:00:00Z","timestamp":1775779200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Reports"],"abstract":"<jats:p>Background and Clinical Significance: Patients with a left ventricular assist device (LVAD) are at risk of ventricular arrhythmias, which are generally hemodynamically tolerated if they occur. In such cases, patients may experience painful implantable cardioverter-defibrillator (ICD) shocks. Case Presentation: A 71-year-old patient with a history of dilated cardiomyopathy caused by a phospholamban (PLN) gain-of-function mutation, with a primary prevention ICD and an LVAD, presented with multiple ICD shocks which she experienced as painful and traumatic. She was found to have ongoing ventricular fibrillation with apparent hemodynamic stability. Conversion to sinus rhythm was achieved through intravenous administration of antiarrhythmic drugs followed by external defibrillation using stacked shocks. Due to the traumatic nature of the shocks, the shock function of the ICD was turned off. Nearly two months later, the patient presented for a second time and was again found to have ventricular fibrillation which had been present for at least six weeks. Conversion to sinus rhythm was unsuccessful and the patient was discharged to her home with an advanced care plan and her LVAD was deactivated. The patient died two months later. Conclusions: Patients with an LVAD can remain hemodynamically stable for prolonged periods of time during ventricular arrhythmias. ICD shocks are therefore mostly experienced as painful and even traumatic. Therefore, the routine use of ICD shock therapy in patients with an LVAD should be reconsidered. Adjustment of ICD programming to higher rates and longer detection may be warranted. Further investigation is warranted regarding a switch to devices with an alarm function rather than therapies for tachyarrhythmias.<\/jats:p>","DOI":"10.3390\/reports9020117","type":"journal-article","created":{"date-parts":[[2026,4,10]],"date-time":"2026-04-10T17:05:51Z","timestamp":1775840751000},"page":"117","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Incessant Ventricular Fibrillation in a Patient with a Left Ventricular Assist Device and an Implantable Cardioverter-Defibrillator: A Case Report"],"prefix":"10.3390","volume":"9","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8515-8450","authenticated-orcid":false,"given":"Alwin B. P.","family":"Noordman","sequence":"first","affiliation":[{"name":"Department of Cardiology, Heart Center, University Medical Center Groningen, University of Groningen, 9713 GZ Groningen, The Netherlands"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2581-070X","authenticated-orcid":false,"given":"Michiel","family":"Rienstra","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Heart Center, University Medical Center Groningen, University of Groningen, 9713 GZ Groningen, The Netherlands"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7936-360X","authenticated-orcid":false,"given":"Alexander H.","family":"Maass","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Heart Center, University Medical Center Groningen, University of Groningen, 9713 GZ Groningen, The Netherlands"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2026,4,10]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"1166","DOI":"10.1016\/j.jacep.2018.05.006","article-title":"Predictors and Clinical Impact of Late Ventricular Arrhythmias in Patients with Continuous-Flow Left Ventricular Assist Devices","volume":"4","author":"Galand","year":"2018","journal-title":"JACC Clin. Electrophysiol."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"648","DOI":"10.1161\/CIRCEP.113.000113","article-title":"Ventricular arrhythmias after left ventricular assist device","volume":"6","author":"Nakahara","year":"2013","journal-title":"Circ. Arrhythm. Electrophysiol."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"515","DOI":"10.1111\/j.1540-8167.2011.02223.x","article-title":"Risk of mortality for ventricular arrhythmia in ambulatory LVAD patients","volume":"23","author":"Brenyo","year":"2012","journal-title":"J. Cardiovasc. Electrophysiol."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"835","DOI":"10.1097\/MAT.0000000000001984","article-title":"Stable Ventricular Fibrillation: A Paradigm Rather Than Septal Shift?","volume":"69","author":"Bracy","year":"2023","journal-title":"Asaio J."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"1190","DOI":"10.1016\/S0022-5223(03)00726-8","article-title":"Fifteen-month circulatory support for sustained ventricular fibrillation by left ventricular assist device","volume":"126","author":"Nishimura","year":"2003","journal-title":"J. Thorac. Cardiovasc. Surg."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"772","DOI":"10.1016\/j.healun.2014.04.012","article-title":"Prolonged left ventricular assist device support (18 months) in refractory ventricular fibrillation","volume":"33","author":"Naito","year":"2014","journal-title":"J. Heart Lung Transplant."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"771","DOI":"10.1016\/j.healun.2010.02.001","article-title":"Implantable cardioverter-defibrillator shocks in patients with a left ventricular assist device","volume":"29","author":"Ambardekar","year":"2010","journal-title":"J. Heart Lung Transplant."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1506","DOI":"10.1016\/j.hrthm.2019.06.021","article-title":"Incidence, predictors, and clinical impact of electrical storm in patients with left ventricular assist devices: New insights from the ASSIST-ICD study","volume":"16","author":"Martins","year":"2019","journal-title":"Heart Rhythm."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"589","DOI":"10.1161\/hc0502.103330","article-title":"Quality of life in the antiarrhythmics versus implantable defibrillators trial: Impact of therapy and influence of adverse symptoms and defibrillator shocks","volume":"105","author":"Schron","year":"2002","journal-title":"Circulation"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1093\/europace\/euv411","article-title":"2015 HRS\/EHRA\/APHRS\/SOLAECE expert consensus statement on optimal implantable cardioverter-defibrillator programming and testing","volume":"18","author":"Wilkoff","year":"2016","journal-title":"Europace"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"204","DOI":"10.1111\/pace.14438","article-title":"Impact of ultra-conservative ICD programming in patients with LVADs: Avoiding potentially unnecessary tachy-therapies","volume":"45","author":"Robinson","year":"2022","journal-title":"Pacing Clin. Electrophysiol."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1097\/MAT.0000000000000739","article-title":"Implantable Cardioverter Defibrillators and Survival in Continuous-Flow Left Ventricular Assist Device Patients","volume":"65","author":"Kutyifa","year":"2019","journal-title":"Asaio J."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1016\/j.jacep.2018.08.009","article-title":"Catheter Ablation of Ventricular Tachycardia in Patients with a Ventricular Assist Device: A Systematic Review of Procedural Characteristics and Outcomes","volume":"5","author":"Anderson","year":"2019","journal-title":"JACC Clin. Electrophysiol."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"1708","DOI":"10.1111\/jocs.14639","article-title":"Video assisted thoracoscopic sympathectomy for intractable recurrent VT after minimal-invasive LVAD implantation","volume":"35","author":"Salewski","year":"2020","journal-title":"J. Card. Surg."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"916","DOI":"10.1016\/j.jchf.2017.08.014","article-title":"Implantable Cardioverter-Defibrillators in Patients with a Continuous-Flow Left Ventricular Assist Device: An Analysis of the INTERMACS Registry","volume":"5","author":"Clerkin","year":"2017","journal-title":"JACC Heart Fail."},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"Sgarito, G., Campo, F., Genovese, D., Mugnai, G., Santoro, F., Francia, P., Ruggiero, D., Perrotta, L., and Conti, S. (2026). Contemporary Management of Cardiac Implantable Electronic Devices in the LVAD Era: Evidence, Controversies, and Clinical Implications. Hearts, 7.","DOI":"10.3390\/hearts7010004"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"815","DOI":"10.1016\/j.hroo.2023.11.004","article-title":"Reducing inappropriate and unnecessary implantable cardioverter-defibrillator therapy: Is patient confirmation via a mobile application the solution?","volume":"4","author":"Noordman","year":"2023","journal-title":"Heart Rhythm O2"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"610","DOI":"10.1016\/j.jemermed.2025.10.007","article-title":"Smartwatch-Based Detection of Ventricular Dysrhythmias: A Systematic Review of Literature","volume":"79","author":"Avidan","year":"2025","journal-title":"J. Emerg. Med."}],"container-title":["Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2571-841X\/9\/2\/117\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,10]],"date-time":"2026-04-10T17:10:57Z","timestamp":1775841057000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2571-841X\/9\/2\/117"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4,10]]},"references-count":18,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2026,6]]}},"alternative-id":["reports9020117"],"URL":"https:\/\/doi.org\/10.3390\/reports9020117","relation":{},"ISSN":["2571-841X"],"issn-type":[{"value":"2571-841X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,4,10]]}}}