{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T19:41:02Z","timestamp":1790883662170,"version":"4.1.0"},"reference-count":24,"publisher":"MDPI AG","issue":"2","license":[{"start":{"date-parts":[[2026,4,20]],"date-time":"2026-04-20T00:00:00Z","timestamp":1776643200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/100000002","name":"National Institutes of Health","doi-asserted-by":"publisher","award":["5R42HD107747"],"award-info":[{"award-number":["5R42HD107747"]}],"id":[{"id":"10.13039\/100000002","id-type":"DOI","asserted-by":"publisher"}]},{"award":["5R42HD107747"],"award-info":[{"award-number":["5R42HD107747"]}],"id":[{"id":"https:\/\/ror.org\/01cwqze88","id-type":"ROR","asserted-by":"publisher"}]},{"name":"National Institute of Child Health and Human Development"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Reports"],"abstract":"<jats:p>Background and Clinical Significance: Conventional hard sockets are reported to result in skin breakdown for almost half of transtibial prosthesis users. Adjustable sockets have been developed to better accommodate residual limb shape and volume changes. They have demonstrated optimal skin health in prospective adult clinical studies. Case Presentation: We present the case of a 57-year-old male with a transtibial amputation who enrolled in a research study at the University of Pennsylvania. In the year before enrollment, he experienced frequent, near-constant skin breakdown of the distal residual limb at the anterior tibia due to limb volume fluctuations and excessive pressure from a conventional hard socket and was frequently unable to use his socket due to skin breakdown. The subject was fit with an adjustable, immediate fit transtibial prosthesis (iFIT Prosthetics\u00ae). After a two-week home trial, he rated the adjustable prosthesis 62 out of 70 on an adapted Prosthetic Evaluation Questionnaire, compared with a score of 20 for his conventional prosthesis. Due to improved comfort, he discontinued the use of his conventional device. The subject was followed for over one year and wore the adjustable prosthesis exclusively without a recurrence of skin breakdown. Residual limb volume changes commonly lead to poor socket fit and skin irritation in conventionally fabricated hard sockets, often progressing to skin breakdown. In individuals with diabetes, wound healing can be prolonged and functionally limiting. In this case, an adjustable prosthesis successfully eliminated anterior tibial skin breakdown in a subject predisposed to this injury when using conventional hard sockets. Conclusions: Adjustable sockets can prevent skin breakdown in individuals with transtibial limb loss.<\/jats:p>","DOI":"10.3390\/reports9020125","type":"journal-article","created":{"date-parts":[[2026,4,20]],"date-time":"2026-04-20T07:15:08Z","timestamp":1776669308000},"page":"125","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Adjustable Prosthetic Sockets Are a Potential Solution to Skin Breakdown for Individuals with Lower Limb Loss: A Case Report"],"prefix":"10.3390","volume":"9","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6416-1450","authenticated-orcid":false,"given":"Jessica","family":"Kenia","sequence":"first","affiliation":[{"name":"Department of Physical Medicine and Rehabilitation, University of Pennsylvania School of Medicine, Philadelphia, PA 19146, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jim","family":"Marschalek","sequence":"additional","affiliation":[{"name":"Advanced Design Concepts, Oconomowoc, WI 53066, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3945-1186","authenticated-orcid":false,"given":"Timothy","family":"Dillingham","sequence":"additional","affiliation":[{"name":"Department of Physical Medicine and Rehabilitation, University of Pennsylvania School of Medicine, Philadelphia, PA 19146, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2026,4,20]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"25833","DOI":"10.1038\/s41598-024-74504-3","article-title":"A clinical comparison of a digital versus conventional design methodology for transtibial prosthetic interfaces","volume":"14","author":"Lee","year":"2024","journal-title":"Sci. Rep."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"574","DOI":"10.1097\/PXR.0000000000000351","article-title":"A scoping review of digital fabrication techniques applied to prosthetics and orthotics: Part 1 of 2\u2014Prosthetics","volume":"48","author":"Oldfrey","year":"2024","journal-title":"Prosthet. Orthot. Int."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"1119","DOI":"10.1682\/JRRD.2013.11.0243","article-title":"Reduction of residual limb volume in people with transtibial amputation","volume":"51","author":"Tantua","year":"2014","journal-title":"J. Rehabil. Res. Dev."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"1566","DOI":"10.1016\/j.jbiomech.2004.08.008","article-title":"Changes in interface pressures and shear stresses over time on trans-tibial amputee subjects ambulating with prosthetic limbs: Comparison of diurnal and six-month differences","volume":"38","author":"Sanders","year":"2005","journal-title":"J. Biomech."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"949","DOI":"10.1682\/JRRD.2010.09.0189","article-title":"Residual limb volume change: Systematic review of measurement and management","volume":"48","author":"Sanders","year":"2011","journal-title":"J. Rehabil. Res. Dev."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"683","DOI":"10.1682\/JRRD.2003.10.0153","article-title":"Shape and volume change in the transtibial residuum over the short term: Preliminary investigation of six subjects","volume":"41","author":"Zachariah","year":"2004","journal-title":"J. Rehabil. Res. Dev."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"422","DOI":"10.1097\/PXR.0000000000000285","article-title":"Prosthetic device and service satisfaction, quality of life, and functional performance in lower limb prosthesis clients","volume":"48","author":"DadeMatthews","year":"2024","journal-title":"Prosthet. Orthot. Int."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"563","DOI":"10.1097\/00002060-200108000-00003","article-title":"Use and satisfaction with prosthetic devices among persons with trauma-related amputations: A long-term outcome study","volume":"80","author":"Dillingham","year":"2001","journal-title":"Am. J. Phys. Med. Rehabil."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"659","DOI":"10.1016\/j.apmr.2004.09.003","article-title":"Dermatologic conditions associated with use of a lower-extremity prosthesis","volume":"86","author":"Dudek","year":"2005","journal-title":"Arch. Phys. Med. Rehabil."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"173","DOI":"10.2340\/00015555-1040","article-title":"Skin problems of the stump in lower limb amputees: 1. A clinical study","volume":"91","author":"Meulenbelt","year":"2011","journal-title":"Acta Derm. Venereol."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"1210","DOI":"10.1002\/pmrj.12133","article-title":"A prospective assessment of an adjustable, immediate fit, transtibial prosthesis","volume":"11","author":"Dillingham","year":"2019","journal-title":"PM&R"},{"key":"ref_12","first-page":"100090","article-title":"Improved self-reported comfort, stability, and limb temperature regulation with an immediate fit, adjustable transtibial prosthesis","volume":"2","author":"McCloskey","year":"2020","journal-title":"Arch. Rehabil. Res. Clin. Transl."},{"key":"ref_13","first-page":"100200","article-title":"A prospective assessment of an adjustable, immediate fit, subischial transfemoral prosthesis","volume":"4","author":"Dillingham","year":"2022","journal-title":"Arch. Rehabil. Res. Clin. Transl."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"931","DOI":"10.1016\/S0003-9993(98)90090-9","article-title":"Prosthetic Evaluation Questionnaire (PEQ)","volume":"79","author":"Legro","year":"1998","journal-title":"Arch. Phys. Med. Rehabil."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"50","DOI":"10.1001\/jama.2010.1923","article-title":"Gait speed and survival in older adults","volume":"305","author":"Studenski","year":"2011","journal-title":"JAMA"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1519\/00139143-200932020-00002","article-title":"Walking speed: The sixth vital sign","volume":"32","author":"Fritz","year":"2009","journal-title":"J. Geriatr. Phys. Ther."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"45517","DOI":"10.33137\/cpoj.v8i1.45517","article-title":"Exploring the correlation between gait speed and balance in limb prosthesis users: A pilot study","volume":"8","author":"Alhuzaymi","year":"2025","journal-title":"Can. Prosthet. Orthot. J."},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Aguila, S.I., S\u00e1nchez, G.J., Sauvain, E.E., Alemon, B., Fuentes-Aguilar, R.Q., and Huegel, J.C. (2020). Interface pressure system to compare the functional performance of prosthetic sockets during gait in people with trans-tibial amputation. Sensors, 20.","DOI":"10.3390\/s20247043"},{"key":"ref_19","first-page":"176","article-title":"Quantitative analysis of interface pressures in transfemoral prosthetic sockets","volume":"48","author":"Truppa","year":"2023","journal-title":"Prosthet. Orthot. Int."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"629","DOI":"10.4239\/wjd.v15.i4.629","article-title":"Prevalence and risk factors of wound complications after transtibial amputation in patients with diabetic foot","volume":"15","author":"Park","year":"2024","journal-title":"World J. Diabetes"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"535","DOI":"10.1001\/journalofethics.2015.17.6.stas1-1506","article-title":"Ethics, rehabilitation access, and quality care following amputation","volume":"17","author":"Pasquina","year":"2015","journal-title":"AMA J. Ethics"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"175","DOI":"10.21300\/18.2-3.2016.175","article-title":"Comparative effectiveness of an adjustable transfemoral prosthetic interface accommodating volume fluctuation: Case Study","volume":"18","author":"Kahle","year":"2016","journal-title":"Technol. Innov."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"8","DOI":"10.1080\/19498241.2024.2420595","article-title":"Adjustable-volume prosthetic interfaces: A systematic literature review and meta-analysis of clinical outcomes","volume":"24","author":"Klenow","year":"2025","journal-title":"Technol. Innov."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"147","DOI":"10.1186\/s12984-023-01270-0","article-title":"Adjustable prosthetic sockets: A systematic review of industrial and research design characteristics and their justifications","volume":"20","author":"Baldock","year":"2023","journal-title":"J. Neuroeng. Rehabil."}],"container-title":["Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2571-841X\/9\/2\/125\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,22]],"date-time":"2026-04-22T04:13:16Z","timestamp":1776831196000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2571-841X\/9\/2\/125"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4,20]]},"references-count":24,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2026,6]]}},"alternative-id":["reports9020125"],"URL":"https:\/\/doi.org\/10.3390\/reports9020125","relation":{},"ISSN":["2571-841X"],"issn-type":[{"value":"2571-841X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,4,20]]}}}