{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,3]],"date-time":"2026-10-03T17:28:55Z","timestamp":1791048535229,"version":"4.1.0"},"reference-count":55,"publisher":"MDPI AG","issue":"18","license":[{"start":{"date-parts":[[2020,9,18]],"date-time":"2020-09-18T00:00:00Z","timestamp":1600387200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Patients at risk of developing respiratory dysfunctions, such as patients with severe forms of muscular dystrophy, need a careful respiratory assessment, and periodic follow-up visits to monitor the progression of the disease. In these patients, at-home continuous monitoring of respiratory activity patterns could provide additional understanding about disease progression, allowing prompt clinical intervention. The core aim of the present study is thus to investigate the feasibility of using an innovative wearable device for respiratory monitoring, particularly breathing frequency variation assessment, in patients with muscular dystrophy. A comparison of measurements of breathing frequency with gold standard methods showed that the device based on the inertial measurement units (IMU-based device) provided optimal results in terms of accuracy errors, correlation, and agreement. Participants positively evaluated the device for ease of use, comfort, usability, and wearability. Moreover, preliminary results confirmed that breathing frequency is a valuable breathing parameter to monitor, at the clinic and at home, because it strongly correlates with the main indexes of respiratory function.<\/jats:p>","DOI":"10.3390\/s20185346","type":"journal-article","created":{"date-parts":[[2020,9,18]],"date-time":"2020-09-18T10:22:23Z","timestamp":1600424543000},"page":"5346","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":16,"title":["A Wearable Device for Breathing Frequency Monitoring: A Pilot Study on Patients with Muscular Dystrophy"],"prefix":"10.3390","volume":"20","author":[{"given":"Ambra","family":"Cesareo","sequence":"first","affiliation":[{"name":"Scientific Institute, IRCCS \u201cE. Medea\u201d, Bioengineering Lab, Bosisio Parini, 23842 Lecco, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1494-6684","authenticated-orcid":false,"given":"Santa Aurelia","family":"Nido","sequence":"additional","affiliation":[{"name":"Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, 20133 Milano, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Emilia","family":"Biffi","sequence":"additional","affiliation":[{"name":"Scientific Institute, IRCCS \u201cE. Medea\u201d, Bioengineering Lab, Bosisio Parini, 23842 Lecco, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sandra","family":"Gandossini","sequence":"additional","affiliation":[{"name":"Scientific Institute, IRCCS \u201cE. Medea\u201d, Department of Neurorehabilitation, Neuromuscular Unit, Bosisio Parini, 23842 Lecco, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maria Grazia","family":"D\u2019Angelo","sequence":"additional","affiliation":[{"name":"Scientific Institute, IRCCS \u201cE. Medea\u201d, Department of Neurorehabilitation, Neuromuscular Unit, Bosisio Parini, 23842 Lecco, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2950-0231","authenticated-orcid":false,"given":"Andrea","family":"Aliverti","sequence":"additional","affiliation":[{"name":"Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, 20133 Milano, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2020,9,18]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1002\/(SICI)1099-0496(200002)29:2<141::AID-PPUL9>3.0.CO;2-Y","article-title":"Pulmonary Manifestations of Neuromuscular Disease with Special Reference to Duchenne Muscular Dystrophy and Spinal Muscular Atrophy","volume":"29","author":"Gozal","year":"2000","journal-title":"Pediatr. Pulmonol."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"295","DOI":"10.1093\/brain\/119.1.295","article-title":"Juvenile Limb-Girdle Muscular Dystrophy: Clinical, Histopathological and Genetic Data from a Small Community Living in the Reunion Island","volume":"119","author":"Fardeau","year":"1996","journal-title":"Brain"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"3237","DOI":"10.1093\/brain\/awm259","article-title":"Analysis of the UK Diagnostic Strategy for Limb Girdle Muscular Dystrophy 2A","volume":"130","author":"Groen","year":"2007","journal-title":"Brain"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"1735","DOI":"10.1093\/brain\/121.9.1735","article-title":"Limb-Girdle Muscular Dystrophy in Guipuzcoa (Basque Country, Spain)","volume":"121","author":"Urtasun","year":"1998","journal-title":"Brain"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"229","DOI":"10.1016\/j.bbadis.2006.06.009","article-title":"Current Treatment of Adult Duchenne Muscular Dystrophy","volume":"1772","author":"Wagner","year":"2007","journal-title":"Biochim. Biophys. Acta Mol. Basis Dis."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"1453","DOI":"10.1212\/WNL.0000000000000892","article-title":"Evidence-Based Guideline Summary: Diagnosis and Treatment of Limb-Girdle and Distal Dystrophies: Report of the Guideline Development Subcommittee of the American Academy of Neurology and the Practice Issues Review Panel of the American Association of Neuromuscular & Electrodiagnostic Medicine","volume":"83","author":"Narayanaswami","year":"2014","journal-title":"Neurology"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"657","DOI":"10.5694\/j.1326-5377.2008.tb01825.x","article-title":"Respiratory Rate: The Neglected Vital Sign","volume":"188","author":"Cretikos","year":"2008","journal-title":"Med. J. Aust."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"797","DOI":"10.1046\/j.1365-2044.2003.03258.x","article-title":"Effect of Introducing the Modified Early Warning Score on Clinical Outcomes, cardio-pulmonary Arrests and Intensive Care Utilisation in Acute Medical Admissions","volume":"58","author":"Subbe","year":"2003","journal-title":"Anaesthesia"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"527","DOI":"10.1378\/chest.65.5.527","article-title":"Factors Determining Survival in Patients with Cardiac Arrest","volume":"65","author":"Castagna","year":"1974","journal-title":"Chest"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"354","DOI":"10.1007\/BF02600071","article-title":"Respiratory Rate Predicts Cardiopulmonary Arrest for Internal Medicine Inpatients","volume":"8","author":"Fieselmann","year":"1993","journal-title":"J. Gen. Intern. Med."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"1317","DOI":"10.1378\/chest.97.6.1317","article-title":"Importance of Respiratory Rate as an Indicator of Respiratory Dysfunction in Patients with Cystic Fibrosis","volume":"97","author":"Browning","year":"1990","journal-title":"Chest"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"1123","DOI":"10.1001\/jama.1980.03310100041029","article-title":"Respiratory Rate as an Indicator of Acute Respiratory Dysfunction","volume":"244","author":"Gravelyn","year":"1980","journal-title":"JAMA"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"626","DOI":"10.1136\/bmj.284.6316.626","article-title":"Raised Respiratory Rate in Elderly Patients: A Valuable Physical Sign","volume":"284","author":"McFadden","year":"1982","journal-title":"Br. Med. J."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"1019","DOI":"10.1139\/apnm-2015-0140","article-title":"Validation of the Hexoskin wearable vest during lying, sitting, standing, and walking activities","volume":"40","author":"Villar","year":"2015","journal-title":"Appl. Physiol. Nutr. Metab."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"231","DOI":"10.1016\/j.ijcard.2018.06.044","article-title":"Qualitative and quantitative evaluation of a new wearable device for ECG and respiratory Holter monitoring","volume":"272","author":"Sarmento","year":"2018","journal-title":"Int. J. Cardiol."},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"Antonelli, A., Guilizzoni, D., Angelucci, A., Melloni, G., Mazza, F., Stanzi, A., Venturino, M., Kuller, D., and Aliverti, A. (2020). Comparison between the Airgo\u2122 Device and a Metabolic Cart during Rest and Exercise. Sensors, 20.","DOI":"10.3390\/s20143943"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1038\/s41746-019-0083-3","article-title":"Respiration rate and volume measurements using wearable strain sensors","volume":"2","author":"Chu","year":"2019","journal-title":"NPJ Digit. Med."},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Naranjo-Hern\u00e1ndez, D., Talaminos-Barroso, A., Reina-Tosina, J., Roa, L.M., Barbarov-Rosta, G., Cejudo-Ramos, P., M\u00e1rquez-Mart\u00edn, E., and Ortega-Ruiz, F. (2018). Smart Vest for Respiratory Rate Monitoring of COPD Patients Based on Non-Contact Capacitive Sensing. Sensors, 18.","DOI":"10.3390\/s18072144"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"e201700263","DOI":"10.1002\/jbio.201700263","article-title":"Smart textile for respiratory monitoring andthoraco-abdominal motion pattern evaluation","volume":"11","author":"Massaroni","year":"2018","journal-title":"J. Biophotonics"},{"key":"ref_20","doi-asserted-by":"crossref","unstructured":"Hung, P., Bonnet, S., Guillemaud, R., Castelli, E., and Yen, P.T.N. (2008, January 14\u201317). Estimation of Respiratory Waveform using an Accelerometer. Proceedings of the 2008 5th IEEE International Symposium on Biomedical Imaging: From Nano to Macro, Paris, France.","DOI":"10.1109\/ISBI.2008.4541291"},{"key":"ref_21","unstructured":"Jin, A., Yin, B., Morren, G., Duric, H., and Aarts, R.M. (2009, January 3\u20136). Performance Evaluation of a Tri-Axial Accelerometry-Based Respiration Monitoring for Ambient Assisted Living. Proceedings of the 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Minneapolis, MN, USA."},{"key":"ref_22","doi-asserted-by":"crossref","unstructured":"Bates, A., Ling, M.J., Mann, J., and Arvind, D. (2010, January 7\u20139). Respiratory Rate and Flow Waveform Estimation from Tri-Axial Accelerometer Data. Proceedings of the 2010 International Conference on Body Sensor Networks, Singapore.","DOI":"10.1109\/BSN.2010.50"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"705","DOI":"10.1089\/tmj.2011.0022","article-title":"Estimation of Respiration Rate from Three-Dimensional Acceleration Data Based on Body Sensor Network","volume":"17","author":"Liu","year":"2011","journal-title":"Telemed. E-Health"},{"key":"ref_24","doi-asserted-by":"crossref","unstructured":"Mann, J., Rabinovich, R., Bates, A., Giavedoni, S., MacNee, W., and Arvind, D. (2011, January 23\u201325). Simultaneous Activity and Respiratory Monitoring using an Accelerometer. Proceedings of the 2011 International Conference on Body Sensor Networks, Dallas, TX, USA.","DOI":"10.1109\/BSN.2011.26"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"11204","DOI":"10.3390\/s140611204","article-title":"A Medical Cloud-Based Platform for Respiration Rate Measurement and Hierarchical Classification of Breath Disorders","volume":"14","author":"Fekr","year":"2014","journal-title":"Sensors"},{"key":"ref_26","doi-asserted-by":"crossref","unstructured":"Cesareo, A., Gandolfi, S., Pini, I., Biffi, E., Reni, G., and Aliverti, A. (2017, January 11\u201315). A Novel, Low Cost, Wearable Contact-Based Device for Breathing Frequency Monitoring. Proceedings of the 2017 39th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Seogwipo, Korea.","DOI":"10.1109\/EMBC.2017.8037340"},{"key":"ref_27","doi-asserted-by":"crossref","unstructured":"Cesareo, A., Previtali, Y., Biffi, E., and Aliverti, A. (2019). Assessment of Breathing Parameters using an Inertial Measurement Unit (IMU)-Based System. Sensors, 19.","DOI":"10.3390\/s19010088"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1007\/s11517-020-02125-9","article-title":"A Novel Acquisition Platform for Long-Term Breathing Frequency Monitoring Based on Inertial Measurement Units","volume":"58","author":"Cesareo","year":"2020","journal-title":"Med. Biol. Eng. Comput."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"347","DOI":"10.1016\/S1474-4422(18)30025-5","article-title":"Diagnosis and Management of Duchenne Muscular Dystrophy, Part 2: Respiratory, Cardiac, Bone Health, and Orthopaedic Management","volume":"17","author":"Birnkrant","year":"2018","journal-title":"Lancet Neurol."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"1305","DOI":"10.1111\/j.1468-1331.2007.01979.x","article-title":"EFNS Guideline on Diagnosis and Management of Limb Girdle Muscular Dystrophies","volume":"14","author":"Norwood","year":"2007","journal-title":"Eur. J. Neurol."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1183\/09031936.05.00034505","article-title":"General Considerations for Lung Function Testing","volume":"26","author":"Miller","year":"2005","journal-title":"Eur. Respir. J."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"319","DOI":"10.1183\/09031936.05.00034805","article-title":"Standardisation of Spirometry","volume":"26","author":"Miller","year":"2005","journal-title":"Eur. Respir. J."},{"key":"ref_33","doi-asserted-by":"crossref","unstructured":"American Thoracic Society\/European Respiratory Society (2002). ATS\/ERS Statement on Respiratory Muscle Testing. Am. J. Respir. Crit. Care Med., 166, 518\u2013624.","DOI":"10.1164\/rccm.166.4.518"},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"60","DOI":"10.1114\/1.1332084","article-title":"Compartmental Analysis of Breathing in the Supine and Prone Positions by Optoelectronic Plethysmography","volume":"29","author":"Aliverti","year":"2001","journal-title":"Ann. Biomed. Eng."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"1546","DOI":"10.1164\/ajrccm.161.5.9903024","article-title":"Optoelectronic Plethysmography in Intensive Care Patients","volume":"161","author":"Aliverti","year":"2000","journal-title":"Am. J. Respir. Crit. Care Med."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"2680","DOI":"10.1152\/jappl.1996.81.6.2680","article-title":"Chest Wall and Lung Volume Estimation by Optical Reflectance Motion Analysis","volume":"81","author":"Cala","year":"1996","journal-title":"J. Appl. Physiol."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"1242","DOI":"10.1152\/jappl.1997.83.4.1242","article-title":"Rib Cage Mechanics during Quiet Breathing and Exercise in Humans","volume":"83","author":"Kenyon","year":"1997","journal-title":"J. Appl. Physiol."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"473","DOI":"10.1016\/j.resp.2013.08.023","article-title":"Optoelectronic Plethysmography: Intra-Rater and Inter-Rater Reliability in Healthy Subjects","volume":"189","author":"Vieira","year":"2013","journal-title":"Respir. Physiol. Neurobiol."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"362","DOI":"10.1016\/j.resp.2012.09.004","article-title":"Optoelectronic Plethysmography Compared to Spirometry during Maximal Exercise","volume":"185","author":"Layton","year":"2013","journal-title":"Respir. Physiol. Neurobiol."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"1943","DOI":"10.1152\/japplphysiol.00393.2000","article-title":"Determinants of Exercise Performance in Normal Men with Externally Imposed Expiratory Flow Limitation","volume":"92","author":"Iandelli","year":"2002","journal-title":"J. Appl. Physiol."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"1118","DOI":"10.1183\/09031936.00037209","article-title":"Abdominal Volume Contribution to Tidal Volume as an Early Indicator of Respiratory Impairment in Duchenne Muscular Dystrophy","volume":"35","author":"Romei","year":"2010","journal-title":"Eur. Respir. J."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"955","DOI":"10.4187\/respcare.05895","article-title":"Acute Effects of Mechanical Insufflation-Exsufflation on the Breathing Pattern in Stable Subjects with Duchenne Muscular Dystrophy","volume":"63","author":"Cesareo","year":"2018","journal-title":"Respir. Care"},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"649","DOI":"10.1139\/apnm-2015-0269","article-title":"Effects of a Multidisciplinary Body Weight Reduction Program on Static and Dynamic Thoraco-Abdominal Volumes in Obese Adolescents","volume":"41","author":"LoMauro","year":"2016","journal-title":"Appl. Physiol. Nutr. Metab."},{"key":"ref_44","first-page":"4","article-title":"SUS-A Quick and Dirty Usability Scale","volume":"189","author":"Brooke","year":"1996","journal-title":"Usability Eval. Ind."},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"574","DOI":"10.1080\/10447310802205776","article-title":"An Empirical Evaluation of the System Usability Scale","volume":"24","author":"Bangor","year":"2008","journal-title":"Int. J. Hum. Comput. Interact."},{"key":"ref_46","doi-asserted-by":"crossref","unstructured":"Lewis, J.R., and Sauro, J. (2009, January 19\u201324). The Factor Structure of the System Usability Scale. Proceedings of the International Conference on Human Centered Design, San Diego, CA, USA.","DOI":"10.1007\/978-3-642-02806-9_12"},{"key":"ref_47","unstructured":"(2020, September 17). Measuring Usability with the System Usability Scale. Available online: https:\/\/www.userfocus.co.uk\/articles\/measuring-usability-with-the-SUS.html."},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"307","DOI":"10.2307\/2987937","article-title":"Measurement in Medicine: The Analysis of Method Comparison Studies","volume":"32","author":"Altman","year":"1983","journal-title":"Statistician"},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1016\/S0140-6736(86)90837-8","article-title":"Statistical Methods for Assessing Agreement between Two Methods of Clinical Measurement","volume":"327","author":"Bland","year":"1986","journal-title":"Lancet"},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1177\/096228029900800204","article-title":"Measuring Agreement in Method Comparison Studies","volume":"8","author":"Bland","year":"1999","journal-title":"Stat. Methods Med. Res."},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"267","DOI":"10.1111\/j.1469-8749.2011.04164.x","article-title":"The Importance of Addressing Heteroscedasticity in the Reliability Analysis of ratio-scaled Variables: An Example Based on Walking energy-cost Measurements","volume":"54","author":"Brehm","year":"2012","journal-title":"Dev. Med. Child Neurol."},{"key":"ref_52","unstructured":"(2009, December 10). How Do I Estimate Limits of Agreement When the Mean or SD of Differences Is not Constant. Available online: https:\/\/www-users.york.ac.uk\/~mb55\/meas\/glucose.htm."},{"key":"ref_53","doi-asserted-by":"crossref","first-page":"143","DOI":"10.1111\/j.1440-1681.2009.05288.x","article-title":"Confidence in Altman\u2013Bland Plots: A Critical Review of the Method of Differences","volume":"37","author":"Ludbrook","year":"2010","journal-title":"Clin. Exp. Pharmacol. Physiol."},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"491","DOI":"10.1109\/TITB.2009.2027231","article-title":"An Accelerometer-Based Device for Sleep Apnea Screening","volume":"14","author":"Morillo","year":"2010","journal-title":"IEEE Trans. Inf. Technol. Biomed."},{"key":"ref_55","doi-asserted-by":"crossref","first-page":"60","DOI":"10.1016\/j.resp.2013.11.003","article-title":"Respiratory Rate Assessments using a Dual-Accelerometer Device","volume":"191","author":"Lapi","year":"2014","journal-title":"Respir. Physiol. Neurobiol."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/20\/18\/5346\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T10:11:18Z","timestamp":1760177478000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/20\/18\/5346"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,9,18]]},"references-count":55,"journal-issue":{"issue":"18","published-online":{"date-parts":[[2020,9]]}},"alternative-id":["s20185346"],"URL":"https:\/\/doi.org\/10.3390\/s20185346","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,9,18]]}}}