{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,1]],"date-time":"2026-07-01T17:33:06Z","timestamp":1782927186670,"version":"3.54.5"},"reference-count":55,"publisher":"MDPI AG","issue":"20","license":[{"start":{"date-parts":[[2021,10,18]],"date-time":"2021-10-18T00:00:00Z","timestamp":1634515200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>This work reports the fabrication of integrated electrochemical fluidic paper-based analytical devices (ePADs) using a marker pen drawing and screen-printing. Electrodes were deposited on paper using screen-printing with conductive carbon ink. Then, the desired fluidic patterns were formed on the paper substrate by drawing with a commercial hydrophobic marker pen using an inexpensive computer-controlled x-y plotter. The working electrode was characterized by cyclic voltammetry and scanning electron microscopy. The analytical utility of the electrochemical PADs is demonstrated through electrochemical determination of Pb(II) and Cd(II) by anodic stripping voltammetry. For this purpose, the sample was mixed with a buffer solution and a Bi(III) solution, applied to the test zone of the PAD, the metals were preconcentrated as a bismuth alloy on the electrode surface and oxidized by applying an anodic potential scan. The proposed manufacturing approach enables the large-scale fabrication of fit-for-purpose disposable PADs at low cost which can be used for rapid on-site environmental monitoring.<\/jats:p>","DOI":"10.3390\/s21206908","type":"journal-article","created":{"date-parts":[[2021,10,20]],"date-time":"2021-10-20T21:31:26Z","timestamp":1634765486000},"page":"6908","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":12,"title":["Single-Use Fluidic Electrochemical Paper-Based Analytical Devices Fabricated by Pen Plotting and Screen-Printing for On-Site Rapid Voltammetric Monitoring of Pb(II) and Cd(II)"],"prefix":"10.3390","volume":"21","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-3289-3408","authenticated-orcid":false,"given":"Dionysios","family":"Soulis","sequence":"first","affiliation":[{"name":"Department of Chemistry, National and Kapodistrian University of Athens, 15771 Athens, Greece"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8271-0134","authenticated-orcid":false,"given":"Maria","family":"Trachioti","sequence":"additional","affiliation":[{"name":"Department of Chemistry, University of Ioannina, 45110 Ioannina, Greece"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4696-0245","authenticated-orcid":false,"given":"Christos","family":"Kokkinos","sequence":"additional","affiliation":[{"name":"Department of Chemistry, National and Kapodistrian University of Athens, 15771 Athens, Greece"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4590-9261","authenticated-orcid":false,"given":"Anastasios","family":"Economou","sequence":"additional","affiliation":[{"name":"Department of Chemistry, National and Kapodistrian University of Athens, 15771 Athens, Greece"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mamas","family":"Prodromidis","sequence":"additional","affiliation":[{"name":"Department of Chemistry, University of Ioannina, 45110 Ioannina, Greece"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2021,10,18]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"167","DOI":"10.1093\/bmb\/ldg032","article-title":"Hazards of heavy metal contamination","volume":"68","author":"Jarup","year":"2003","journal-title":"Br. Med. Bull."},{"key":"ref_2","unstructured":"Sarkar, D., Datta, R., and Hannigan, R. (2007). Metal ions speciation in the environment: Distribution, toxicities and analyses. Developments in Environmental Science, Elsevier."},{"key":"ref_3","unstructured":"El-Din, H., Saleh, M., and Aglan, R.F. (2018). Environmental contamination by heavy metals. Heavy Metals, Intech Open."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"476","DOI":"10.1016\/j.scitotenv.2016.06.166","article-title":"Heavy metals in drinking water: Occurrences, implications, and future needs in developing countries","volume":"569\u2013570","author":"Chowdhury","year":"2016","journal-title":"Sci. Total Environ."},{"key":"ref_5","first-page":"567","article-title":"Heavy metal pollution in drinking water\u2014A global risk for human health: A review","volume":"7","author":"Luna","year":"2013","journal-title":"Afr. J. Environ. Sci. Technol."},{"key":"ref_6","unstructured":"World Health Organization (1972). Evaluation of Certain Food Additives and the Contaminats Mercury, Lead, and Cadmium, Sixteenth Report of the Joint FAO\/WHO Expert Committee on Food Additive, World Health Organization. Available online: https:\/\/apps.who.int\/iris\/handle\/10665\/40985."},{"key":"ref_7","first-page":"94","article-title":"Effect of toxic metals on human health","volume":"3","author":"Mudgal","year":"2014","journal-title":"Open Nutraceuticals J."},{"key":"ref_8","doi-asserted-by":"crossref","unstructured":"Karcioglu, O., and Arslan, B. (2019). Mechanism and health effects of heavy metal toxicity in humans. Poisoning in the Modern World-New Tricks for an Old Dog, IntechOpen.","DOI":"10.5772\/intechopen.73906"},{"key":"ref_9","first-page":"10","article-title":"Effect on human health due to drinking water contaminated with heavy metals","volume":"5","author":"QA","year":"2016","journal-title":"J. Pollut. Eff. Control"},{"key":"ref_10","first-page":"2015","article-title":"Effect of heavy metal ions in water on human health","volume":"4","author":"Chouhan","year":"2016","journal-title":"Int. J. Sci. Eng. Res."},{"key":"ref_11","first-page":"12","article-title":"Heavy metals (As, Cd & Pb) toxicity & detection of these metals in ground water sample: A review on different techniques","volume":"7","author":"Bhattacharjee","year":"2018","journal-title":"Int. J. Eng. Sci. Invent."},{"key":"ref_12","first-page":"20178002","article-title":"Analytical techniques for trace element determination","volume":"2","author":"Bulska","year":"2017","journal-title":"Phys. Sci. Rev."},{"key":"ref_13","first-page":"427","article-title":"Main analytical techniques used for elemental analysis in various matrices","volume":"15","author":"Khalid","year":"2016","journal-title":"J. Pharm. Res."},{"key":"ref_14","doi-asserted-by":"crossref","unstructured":"Arrigan, D.W.M. (2016). Electrochemical Strategies in Detection Science, The Royal Society of Chemistry.","DOI":"10.1039\/9781782622529"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"6834","DOI":"10.1039\/C9AN01437C","article-title":"Addressing the practicalities of anodic stripping voltammetry for heavy metal detection: A tutorial review","volume":"144","author":"Borrill","year":"2019","journal-title":"Analyst"},{"key":"ref_16","unstructured":"Thomas, S., Ahmadi, M., Nguyen, T.A., Afkhami, A., and Madrakian, T. (2021). Micro-and Nanotechnology Enabled Applications for Portable Miniaturized Analytical Systems, Elsevier. [1st ed.]."},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Rios, A., Escarpa, A., and Simonet, B. (2009). Miniaturization of Analytical Systems: Principles, Designs and Applications, Wiley.","DOI":"10.1002\/9780470748091"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"589","DOI":"10.1016\/j.cclet.2019.09.022","article-title":"Miniaturized electrochemical sensors and their point-of-care applications","volume":"31","author":"Zhang","year":"2020","journal-title":"Chin. Chem. Lett."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"1605271","DOI":"10.1002\/adfm.201605271","article-title":"Wearable and Miniaturized sensor technologies for personalized and preventive medicine","volume":"27","author":"Tricoli","year":"2017","journal-title":"Adv. Funct. Mater."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"7573","DOI":"10.1007\/s00216-013-6911-4","article-title":"Sensing approaches on paper-based devices: A review","volume":"405","author":"Nery","year":"2013","journal-title":"Anal. Bioanal. Chem."},{"key":"ref_21","doi-asserted-by":"crossref","unstructured":"Tribhuwan Singh, A., Lantigua, D., Meka, A., Taing, S., Pandher, M., and Camci-Unal, G. (2018). Paper-based sensors: Emerging themes and applications. Sensors, 18.","DOI":"10.3390\/s18092838"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"126855","DOI":"10.1016\/j.snb.2019.126855","article-title":"Microfluidic paper-based analytical devices for environmental analysis of soil, air, ecology and river water","volume":"301","author":"Kung","year":"2019","journal-title":"Sens. Actuat. B Chem."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"196","DOI":"10.1016\/j.trac.2018.08.018","article-title":"Detection methods and applications of microfluidic paper-based analytical devices","volume":"107","author":"Fu","year":"2018","journal-title":"Trends Anal. Chem. TrAC"},{"key":"ref_24","doi-asserted-by":"crossref","unstructured":"Lim, H., Turab Jafry, A., and Lee, J. (2019). Fabrication, flow control, and applications of microfluidic paper-based analytical devices. Molecules, 24.","DOI":"10.3390\/molecules24162869"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1146\/annurev-anchem-061318-114845","article-title":"Advances in paper-based analytical devices","volume":"13","author":"Ozer","year":"2020","journal-title":"Ann. Rev. Anal. Chem."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.aca.2017.11.010","article-title":"Review on microfluidic paper-based analytical devices towards commercialization","volume":"1001","author":"Akyazi","year":"2018","journal-title":"Anal. Chim. Acta"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1039\/C9LC00903E","article-title":"Electrochemical paper-based devices: Sensing approaches and progress toward practical applications","volume":"20","author":"Noviana","year":"2020","journal-title":"Lab. Chip"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"1030","DOI":"10.1039\/C9AY02350J","article-title":"Electrochemical paper-based analytical devices: Ten years of development","volume":"12","author":"Ataide","year":"2020","journal-title":"Anal. Methods"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"2939","DOI":"10.1002\/celc.202000512","article-title":"Paper-based electrochemical sensors and how to make them (work)","volume":"7","author":"Mazurkiewicz","year":"2020","journal-title":"ChemElectroChem"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"1420","DOI":"10.1002\/elan.201501143","article-title":"Electrochemistry on paper-based analytical devices: A review","volume":"28","author":"Mettakoonpitak","year":"2016","journal-title":"Electroanalysis"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"10454","DOI":"10.1021\/acs.analchem.7b02521","article-title":"Digitally controlled procedure for assembling fully drawn paper-based electroanalytical platforms","volume":"89","author":"Dossi","year":"2017","journal-title":"Anal. Chem."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"3553","DOI":"10.1038\/s41598-017-02931-6","article-title":"High-throughput rapid-prototyping of low-cost paper-based microfluidics","volume":"7","author":"Ghaderinezhad","year":"2017","journal-title":"Sci. Rep."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"6351","DOI":"10.1021\/acs.analchem.7b01418","article-title":"Continuous-ink, multiplexed pen-plotter approach for low-cost, high-throughput fabrication of paper-based microfluidics","volume":"89","author":"Amin","year":"2017","journal-title":"Anal. Chem"},{"key":"ref_34","doi-asserted-by":"crossref","unstructured":"Pagkali, V., Stavra, E., Soulis, D., and Ecomomou, A. (2021). Development of a high-throughput low-cost approach for fabricating fully drawn paper-based analytical devices using commercial writing tools. Chemosensors, 9.","DOI":"10.3390\/chemosensors9070178"},{"key":"ref_35","doi-asserted-by":"crossref","unstructured":"Costa-Rama, E., and Fern\u00e1ndez-Abedul, M.T. (2021). Paper-based screen-printed electrodes: A new generation of low-cost electroanalytical platforms. Biosensors, 11.","DOI":"10.3390\/bios11020051"},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"41482","DOI":"10.1039\/D0RA07096C","article-title":"Paper-based electroanalytical devices for stripping analysis of lead and cadmium in children\u2019s shoes","volume":"10","author":"Zhu","year":"2020","journal-title":"RSC Adv."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"235","DOI":"10.1016\/j.talanta.2013.04.071","article-title":"Using nanostructured conductive carbon tape modified with bismuth as the disposable working electrode for stripping analysis in paper-based analytical devices","volume":"115","author":"Feng","year":"2013","journal-title":"Talanta"},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"475","DOI":"10.1016\/j.snb.2018.01.007","article-title":"Gold-coated nanostructured carbon tape for rapid electrochemical detection of cadmium in rice with in situ electrodeposition of bismuthin paper-based analytical devices","volume":"260","author":"Bi","year":"2018","journal-title":"Sens. Actuat. B"},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"352","DOI":"10.1007\/s12678-019-00516-7","article-title":"Tuneable, pre-stored paper-based electrochemical cells (\u03bcPECs): An adsorptive stripping voltammetric approach to metal analysis","volume":"10","author":"Pokpas","year":"2019","journal-title":"Electrocatalysis"},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"6415","DOI":"10.1021\/acs.analchem.7b00144","article-title":"Electrogeneration of gold nanoparticles on porous-carbon paper-based electrodes and application to inorganic arsenic analysis in white wines by chronoamperometric stripping","volume":"89","year":"2017","journal-title":"Anal. Chem."},{"key":"ref_41","doi-asserted-by":"crossref","unstructured":"S\u00e1nchez-Calvo, A., Blanco-L\u00f3pez, M.C., and Costa-Garc\u00eda, A. (2020). Paper-based working electrodes coated with mercury or bismuth films for heavy metals determination. Biosensors, 10.","DOI":"10.3390\/bios10050052"},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"3999","DOI":"10.1021\/acssensors.0c01793","article-title":"Dual sample preconcentration for simultaneous quantification of metal ions using electrochemical and colorimetric assays","volume":"5","author":"Ninwong","year":"2020","journal-title":"ACS Sens."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"226","DOI":"10.1002\/elan.202060305","article-title":"A low-cost paper-based diamond electrode for trace copper analysis at on-site environmental area","volume":"33","author":"Thangphatthanarungruang","year":"2021","journal-title":"Electroanalysis"},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"324","DOI":"10.1007\/s00604-018-2821-7","article-title":"Anodic stripping voltammetric determination of total arsenic using a gold nanoparticle-modified boron-doped diamond electrode on a paper-based device","volume":"185","author":"Pungjunun","year":"2018","journal-title":"Microchim. Acta"},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"291","DOI":"10.1016\/j.talanta.2013.05.037","article-title":"Fabrication of paper-baseddevices by lacquer spraying method for the determination of nickel (II) ion in wastewater","volume":"114","author":"Nurak","year":"2013","journal-title":"Talanta"},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"1439","DOI":"10.1021\/acs.analchem.9b04632","article-title":"Janus electrochemical paper-based analytical devices for metals detection in aerosol samples","volume":"92","author":"Mettakoonpitak","year":"2020","journal-title":"Anal. Chem."},{"key":"ref_47","doi-asserted-by":"crossref","unstructured":"Wang, X., Sun, J., Tong, J., Guan, X., Bian, C., and Xia, S. (2018). Paper-based sensor chip for heavy metal ion detection by SWSV. Micromachines, 9.","DOI":"10.3390\/mi9040150"},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"128241","DOI":"10.1016\/j.snb.2020.128241","article-title":"Enhanced sensitivity and separation for simultaneous determination of tin and lead using paper-based sensors combined with a portable potentiostat","volume":"318","author":"Pungjunun","year":"2020","journal-title":"Sens. Actuat. B Chem."},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"1199","DOI":"10.1016\/j.snb.2017.07.161","article-title":"Sustainable monitoring of Zn (II) in biological fluids using office paper","volume":"253","author":"Cinti","year":"2017","journal-title":"Sens. Actuat. B"},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"3017","DOI":"10.1002\/elan.202060379","article-title":"Graphene-AuNP enhanced inkjet-printed silver nanoparticle paper electrodes for the detection of nickel (II)-Dimethylglyoxime [Ni (DMGH2)] complexes by adsorptive cathodic stripping voltammetry (AdCSV)","volume":"32","author":"Pokpas","year":"2020","journal-title":"Electroanalysis"},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1016\/j.aca.2017.07.069","article-title":"Voltammetric determination of metal ions beyond mercury electrodes. A review","volume":"990","author":"Serrano","year":"2017","journal-title":"Anal. Chim. Acta"},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"2206","DOI":"10.1016\/j.electacta.2010.12.017","article-title":"A study of in situ plated tin-film electrodes for the determination of trace metals by means of square-wave anodic stripping voltammetry","volume":"56","author":"Czop","year":"2011","journal-title":"Electrochim. Acta"},{"key":"ref_53","unstructured":"(2021, October 10). The Drinking Water Directive. Available online: https:\/\/ec.europa.eu\/environment\/water\/water-drink\/legislation_en.html."},{"key":"ref_54","unstructured":"(2021, October 10). Safe Drinking Water Act, Available online: https:\/\/www.epa.gov\/sdwa."},{"key":"ref_55","doi-asserted-by":"crossref","first-page":"2359","DOI":"10.1002\/elan.201000252","article-title":"Determination of trace Tl (I) by anodic stripping voltammetry on novel disposable microfabricated bismuth-film sensors","volume":"22","author":"Kokkinos","year":"2010","journal-title":"Electroanalysis"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/21\/20\/6908\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T07:17:28Z","timestamp":1760167048000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/21\/20\/6908"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,10,18]]},"references-count":55,"journal-issue":{"issue":"20","published-online":{"date-parts":[[2021,10]]}},"alternative-id":["s21206908"],"URL":"https:\/\/doi.org\/10.3390\/s21206908","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,10,18]]}}}