{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T17:50:36Z","timestamp":1790877036220,"version":"4.1.0"},"reference-count":18,"publisher":"MDPI AG","issue":"11","license":[{"start":{"date-parts":[[2022,5,25]],"date-time":"2022-05-25T00:00:00Z","timestamp":1653436800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Innovation Incubator 2.0: \u201cData base of the intelligent Cheneau brace\u201d"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>This study presents a prototype of Intelligent Brace\u2014the gold medal winner in the 68th edition of the International EUREKA 2019 Competition, in Valencia, Spain. It shows how to improve the effectiveness of a static orthopedic brace, with modern technology based on advanced electronic solutions. The research uses in-house-made thin-film graphene sensors, an electronic system with a microcontroller and derotating pads, a mobile application for Android system, and a remote database. The article presents a description of the real project, the system principle of operation, and the layout of the system elements in the orthosis. A prototype device was designed and built that was tested not only in laboratory conditions, but also during trials with the first patient. Approximately two months of data were collected and interpreted. The collected research results provided basic knowledge about the range of forces exerted by the brace on the patient\u2019s body, as well as the regularity of wearing the orthosis by the patient and compliance with the doctor\u2019s recommendations.<\/jats:p>","DOI":"10.3390\/s22114015","type":"journal-article","created":{"date-parts":[[2022,5,31]],"date-time":"2022-05-31T02:30:06Z","timestamp":1653964206000},"page":"4015","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":10,"title":["TLSO with Graphene Sensors\u2014An Application to Measurements of Corrective Forces in the Prototype of Intelligent Brace"],"prefix":"10.3390","volume":"22","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5889-2043","authenticated-orcid":false,"given":"Patrycja","family":"Tymi\u0144ska","sequence":"first","affiliation":[{"name":"Lublin University of Technology, Nadbystrzycka Street 38D, 20-618 Lublin, Poland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5240-9890","authenticated-orcid":false,"given":"Katarzyna","family":"Zaborowska-Sapeta","sequence":"additional","affiliation":[{"name":"University of Warmia and Mazury in Olsztyn, Micha\u0142a Oczapowskiego Street 2, 10-719 Olsztyn, Poland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2289-7771","authenticated-orcid":false,"given":"Daniel","family":"Janczak","sequence":"additional","affiliation":[{"name":"Warsaw University of Technology, Plac Politechniki 1, 00-661 Warsaw, Poland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7884-1801","authenticated-orcid":false,"given":"Tomasz","family":"Gi\u017cewski","sequence":"additional","affiliation":[{"name":"Lublin University of Technology, Nadbystrzycka Street 38D, 20-618 Lublin, Poland"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2022,5,25]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1186\/s13013-017-0145-8","article-title":"2016 SOSORT guidelines: Orthopaedic and rehabilitation treatment of idiopathic scoliosis during growth","volume":"13","author":"Negrini","year":"2018","journal-title":"Scoliosis Spinal Disord."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"908","DOI":"10.1109\/TIM.2002.807792","article-title":"Low power wireless load monitoring system for the treatment of scoliosis","volume":"51","author":"Lou","year":"2002","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"ref_3","doi-asserted-by":"crossref","unstructured":"Lou, E., Zbinden, D., Mosberger, P., Hill, D.L., and Raso, V.J. (2008, January 20\u201325). A wireless personal wearable network system to understand the biomechanics of orthotic for the treatment of scoliosis. Proceedings of the 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Vancouver, BC, Canada.","DOI":"10.1109\/IEMBS.2008.4649942"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"1146","DOI":"10.1109\/TIM.2004.831458","article-title":"An intelligent active brace system for the treatment of scoliosis","volume":"53","author":"Lou","year":"2004","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"ref_5","doi-asserted-by":"crossref","unstructured":"Bache, B.A., Iftikhar, O., and Dehzangi, O. (2017, January 18\u201321). Brace Treatment Monitoring Solution for Idiopathic Scoliosis Patients. Proceedings of the 2017 16th IEEE International Conference on Machine Learning and Applications (ICMLA), Cancun, Mexico.","DOI":"10.1109\/ICMLA.2017.00-98"},{"key":"ref_6","doi-asserted-by":"crossref","unstructured":"Dehzangi, O., Iftikhar, O., Bache, B.A., Wensman, J., and Li, Y. (2018, January 12\u201314). Force and activity monitoring system for scoliosis patients wearing back braces. Proceedings of the 2018 IEEE International Conference on Consumer Electronics (ICCE), Las Vegas, NV, USA.","DOI":"10.1109\/ICCE.2018.8326190"},{"key":"ref_7","doi-asserted-by":"crossref","unstructured":"Dehzangi, O., Mohammadi, M., and Li, Y. (2016, January 9\u201311). Smart brace for monitoring patients with scoliosis using a multimodal sensor board solution. Proceedings of the 2016 IEEE Healthcare Innovation Point-Of-Care Technologies Conference (HI-POCT), Cancun, Mexico.","DOI":"10.1109\/HIC.2016.7797698"},{"key":"ref_8","doi-asserted-by":"crossref","unstructured":"Bansode, S., Shinde, T., Nimmagadda, M., Garapati, S., and Abdel-Qader, I. (2017, January 22\u201324). Design and implementation of regulated-pressure brace with on-board control and monitoring abilities for the treatment of scoliosis. Proceedings of the 2017 Second International Conference on Electrical, Computer and Communication Technologies (ICECCT), Coimbatore, India.","DOI":"10.1109\/ICECCT.2017.8117983"},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Hud\u00e1k, R., Rajt\u2019\u00fakov\u00e1, V., \u017divc\u00e1k, J., Hud\u00e1k, J., and Bednar\u010d\u00edkov\u00e1, L. (2012, January 20\u201322). The use of matrix tactile sensors (MTS) for diagnostics of the efficiency of production, testing and application of a trunk orthosis. Proceedings of the 2012 IEEE 13th International Symposium on Computational Intelligence and Informatics (CINTI), Budapest, Hungary.","DOI":"10.1109\/CINTI.2012.6496779"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"3243","DOI":"10.1109\/TIM.2013.2272202","article-title":"Optimization of a Low-Cost Force Sensor for Spinal Orthosis Applications","volume":"62","author":"Evans","year":"2013","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"ref_11","doi-asserted-by":"crossref","unstructured":"Fuss, F.K., Ahmad, A., Tan, A.M., Razman, R., and Weizman, Y. (2021). Pressure sensor system for customised scoliosis braces. Sensors, 21.","DOI":"10.3390\/s21041153"},{"key":"ref_12","unstructured":"Bernat, M. (2017). Virtual Environment for Identification of Static Characteristic Parameters of Thin-Film Resistive Pressure Sensors. [Master\u2019s Thesis, Lublin University of Technology]."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"17304","DOI":"10.3390\/s140917304","article-title":"Screen-printed resistive pressure sensors containing graphene nanoplatelets and carbon nanotubes","volume":"14","author":"Janczak","year":"2014","journal-title":"Sensors"},{"key":"ref_14","unstructured":"Wolska, W. (2019). Complex Mathematical Model of Thin-Film Pressure Sensors. [Master\u2019s Thesis, Lublin University of Technology]."},{"key":"ref_15","unstructured":"Hoffmann, K. (1974). Applying the Wheatstone Bridge Circuit, HBM."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1016\/j.medengphy.2014.12.010","article-title":"An advanced compliance monitor for patients undergoing brace treatment for idiopathic scoliosis","volume":"37","author":"Chalmers","year":"2015","journal-title":"Med. Eng. Phys."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"9","DOI":"10.2106\/JBJS.O.00359","article-title":"Effect of Compliance Counseling on Brace Use and Success in Patients with Adolescent Idiopathic Scoliosis","volume":"98","author":"Karol","year":"2016","journal-title":"J. Bone Jt. Surg."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"345","DOI":"10.1080\/03093640802016092","article-title":"Study of the pressures applied by a Ch\u00eaneau brace for correction of adolescent idiopathic scoliosis","volume":"32","author":"Pham","year":"2008","journal-title":"Prosthet. Orthot. Int."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/22\/11\/4015\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T23:18:45Z","timestamp":1760138325000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/22\/11\/4015"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,5,25]]},"references-count":18,"journal-issue":{"issue":"11","published-online":{"date-parts":[[2022,6]]}},"alternative-id":["s22114015"],"URL":"https:\/\/doi.org\/10.3390\/s22114015","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,5,25]]}}}