{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,3]],"date-time":"2026-09-03T18:10:46Z","timestamp":1788459046355,"version":"build-2803163510"},"reference-count":31,"publisher":"MDPI AG","issue":"3","license":[{"start":{"date-parts":[[2023,1,31]],"date-time":"2023-01-31T00:00:00Z","timestamp":1675123200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100000038","name":"Natural Sciences and Engineering Research Council of Canada","doi-asserted-by":"publisher","award":["RGPIN-2019-05221"],"award-info":[{"award-number":["RGPIN-2019-05221"]}],"id":[{"id":"10.13039\/501100000038","id-type":"DOI","asserted-by":"publisher"}]},{"name":"Ingenuity Labs Research Institute","award":["RGPIN-2019-05221"],"award-info":[{"award-number":["RGPIN-2019-05221"]}]},{"name":"Ontario Graduate Scholarship","award":["RGPIN-2019-05221"],"award-info":[{"award-number":["RGPIN-2019-05221"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>The portability of wearable inertial sensors makes them particularly suitable for measuring gait in real-world walking situations. However, it is unclear how well inertial sensors can measure and evaluate gait stability compared to traditional laboratory-based optical motion capture. This study investigated whether an inertial sensor-based motion-capture suit could accurately assess gait stability. Healthy adult participants were asked to walk normally, with eyes closed, with approximately twice their normal step width, and in tandem. Their motion was simultaneously measured by inertial measurement units (IMU) and optical motion capture (Optical). Gait stability was assessed by calculating the margin of stability (MoS), short-term Lyapunov exponents, and step variability, along with basic gait parameters, using each system. We found that IMUs were able to detect the same differences among conditions as Optical for all but one of the measures. Bland\u2013Altman and intraclass correlation (ICC) analysis demonstrated that mediolateral parameters (step width and mediolateral MoS) were measured less accurately by IMUs compared to their anterior-posterior equivalents (step length and anterior-posterior MoS). Our results demonstrate that IMUs can be used to evaluate gait stability through detecting changes in stability-related measures, but that the magnitudes of these measures might not be accurate or reliable, especially in the mediolateral direction.<\/jats:p>","DOI":"10.3390\/s23031547","type":"journal-article","created":{"date-parts":[[2023,2,1]],"date-time":"2023-02-01T01:36:59Z","timestamp":1675215419000},"page":"1547","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":27,"title":["Validation of Inertial Sensors to Evaluate Gait Stability"],"prefix":"10.3390","volume":"23","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-1108-0504","authenticated-orcid":false,"given":"Paul M.","family":"Riek","sequence":"first","affiliation":[{"name":"Ingenuity Labs Research Institute, Mechanical and Materials Engineering, Queen\u2019s University, Kingston, ON K7L 3N6, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1876-0211","authenticated-orcid":false,"given":"Aaron N.","family":"Best","sequence":"additional","affiliation":[{"name":"Ingenuity Labs Research Institute, Mechanical and Materials Engineering, Queen\u2019s University, Kingston, ON K7L 3N6, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1801-5716","authenticated-orcid":false,"given":"Amy R.","family":"Wu","sequence":"additional","affiliation":[{"name":"Ingenuity Labs Research Institute, Mechanical and Materials Engineering, Queen\u2019s University, Kingston, ON K7L 3N6, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2023,1,31]]},"reference":[{"key":"ref_1","unstructured":"Thewlis, D., Bishop, C., Daniell, N., and Paul, G. (2011, January 3\u20137). A comparison of two commercially available motion capture systems for gait analysis: High end vs low-cost. Proceedings of the 23rd Congress of the International Society of Biomechanics, Brussels, Belgium."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"2085","DOI":"10.1016\/j.jbiomech.2016.05.007","article-title":"Analysis of accuracy in optical motion capture\u2014A protocol for laboratory setup evaluation","volume":"49","author":"Eichelberger","year":"2016","journal-title":"J. Biomech."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"974","DOI":"10.1016\/j.gaitpost.2013.05.012","article-title":"Measurement of foot placement and its variability with inertial sensors","volume":"38","author":"Rebula","year":"2013","journal-title":"Gait Posture"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"62","DOI":"10.1186\/s12984-020-00685-3","article-title":"Validity and reliability of wearable inertial sensors in healthy adult walking: A systematic review and meta-analysis","volume":"17","author":"Kobsar","year":"2020","journal-title":"J. NeuroEng. Rehabil."},{"key":"ref_5","doi-asserted-by":"crossref","unstructured":"Teufl, W., Lorenz, M., Miezal, M., Taetz, B., Fr\u00f6hlich, M., and Bleser, G. (2018). Towards inertial sensor based mobile gait analysis: Event-detection and spatio-temporal parameters. Sensors, 19.","DOI":"10.3390\/s19010038"},{"key":"ref_6","unstructured":"Roetenberg, D., Luinge, H., and Slycke, P. (2009). Xsens MVN: Full 6DOF Human Motion Tracking Using Miniature Inertial Sensors, Xsens Motion Technologies B.V.. Technical Report."},{"key":"ref_7","doi-asserted-by":"crossref","unstructured":"Mavor, M.P., Ross, G.B., Clouthier, A.L., Karakolis, T., and Graham, R.B. (2020). Validation of an IMU suit for military-based tasks. Sensors, 20.","DOI":"10.3390\/s20154280"},{"key":"ref_8","doi-asserted-by":"crossref","unstructured":"Z\u00fcgner, R., Tranberg, R., Timperley, J., Hodgins, D., Mohaddes, M., and K\u00e4rrholm, J. (2019). Validation of inertial measurement units with optical tracking system in patients operated with Total hip arthroplasty. BMC Musculoskelet. Disord., 20.","DOI":"10.1186\/s12891-019-2416-4"},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Yeo, S.S., and Park, G.Y. (2020). Accuracy Verification of Spatio-Temporal and Kinematic Parameters for Gait Using Inertial Measurement Unit System. Sensors, 20.","DOI":"10.3390\/s20051343"},{"key":"ref_10","doi-asserted-by":"crossref","unstructured":"Guaitolini, M., Aprigliano, F., Mannini, A., Micera, S., Monaco, V., and Sabatini, A.M. (2019). Ambulatory Assessment of the Dynamic Margin of Stability Using an Inertial Sensor Network. Sensors, 19.","DOI":"10.3390\/s19194117"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"2588","DOI":"10.1007\/s10439-010-0018-2","article-title":"Estimating dynamic gait stability using data from non-aligned inertial sensors","volume":"38","author":"Bruijn","year":"2010","journal-title":"Ann. Biomed. Eng."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1016\/j.gaitpost.2019.08.006","article-title":"Reliability and concurrent validity of spatiotemporal stride characteristics measured with an ankle-worn sensor among older individuals","volume":"74","author":"Rantalainen","year":"2019","journal-title":"Gait Posture"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"629","DOI":"10.1109\/TNSRE.2020.2971905","article-title":"Inertial Sensor-Based Centripetal Acceleration as a Correlate for Lateral Margin of Stability during Walking and Turning","volume":"28","author":"Fino","year":"2020","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"1152","DOI":"10.1016\/j.medengphy.2015.09.007","article-title":"Towards the assessment of local dynamic stability of level-grounded walking in an older population","volume":"37","author":"Hamacher","year":"2015","journal-title":"Med. Eng. Phys."},{"key":"ref_15","unstructured":"Schepers, M., Giuberti, M., and Bellusci, G. (2018). Xsens MVN: Consistent Tracking of Human Motion Using Inertial Sensing, Xsens Motion Technologies B.V.. Technical Report."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"710","DOI":"10.1016\/j.gaitpost.2007.07.007","article-title":"Two simple methods for determining gait events during treadmill and overground walking using kinematic data","volume":"27","author":"Zeni","year":"2008","journal-title":"Gait Posture"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"112","DOI":"10.1016\/j.humov.2007.08.003","article-title":"The \u2019extrapolated center of mass\u2019 concept suggests a simple control of balance in walking","volume":"27","author":"Hof","year":"2008","journal-title":"Hum. Mov. Sci."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"20120999","DOI":"10.1098\/rsif.2012.0999","article-title":"Assessing the stability of human locomotion: A review of current measures","volume":"10","author":"Bruijn","year":"2013","journal-title":"J. R. Soc. Interface"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"327","DOI":"10.1016\/j.jneumeth.2008.12.015","article-title":"Statistical precision and sensitivity of measures of dynamic gait stability","volume":"178","author":"Bruijn","year":"2009","journal-title":"J. Neurosci. Methods"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1016\/0167-2789(93)90009-P","article-title":"A practical method for calculating largest Lyapunov exponents from small data sets","volume":"65","author":"Rosenstein","year":"1993","journal-title":"Phys. D Nonlinear Phenom."},{"key":"ref_21","unstructured":"Bruijn, S. (2021, June 28). SjoerdBruijn\/LocalDynamicStability: Latest Release, Including Multiple nn. Zenodo GitHub Repository. Retrieved 2021. Available online: https:\/\/zenodo.org\/record\/4681213#.Y3W5SnbMI2w."},{"key":"ref_22","unstructured":"Glantz, S.A. (2005). Primer of Biostatistics, McGraw-Hill Medical."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"466","DOI":"10.1002\/uog.5256","article-title":"Reliability, repeatability and reproducibility: Analysis of measurement errors in continuous variables","volume":"31","author":"Bartlett","year":"2008","journal-title":"Ultrasound Obstet. Gynecol."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1016\/j.jcm.2016.02.012","article-title":"A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research","volume":"15","author":"Koo","year":"2016","journal-title":"J. Chiropr. Med."},{"key":"ref_25","unstructured":"Salarian, A., and Intraclass Correlation Coefficient (ICC) (2021, November 16). MATLAB Central File Exchange. Available online: https:\/\/www.mathworks.com\/matlabcentral\/fileexchange\/22099-intraclass-correlation-coefficient-icc."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"162","DOI":"10.1016\/j.gaitpost.2017.10.002","article-title":"Analysis of biases in dynamic margins of stability introduced by the use of simplified center of mass estimates during walking and turning","volume":"59","author":"Havens","year":"2018","journal-title":"Gait Posture"},{"key":"ref_27","doi-asserted-by":"crossref","unstructured":"Al-Amri, M., Nicholas, K., Button, K., Sparkes, V., Sheeran, L., and Davies, J.L. (2018). Inertial measurement units for clinical movement analysis: Reliability and concurrent validity. Sensors, 18.","DOI":"10.3390\/s18030719"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"310","DOI":"10.1136\/jnnp.73.3.310","article-title":"Typical features of cerebellar ataxic gait","volume":"73","author":"Stolze","year":"2002","journal-title":"J. Neurol. Neurosurg. Psychiatry"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"175","DOI":"10.1016\/j.humov.2018.01.012","article-title":"Cognitive-motor dual-task interference modulates mediolateral dynamic stability during gait in post-stroke individuals","volume":"58","author":"Tisserand","year":"2018","journal-title":"Hum. Mov. Sci."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"1041","DOI":"10.1016\/j.clinbiomech.2013.10.010","article-title":"Stepping strategies used by post-stroke individuals to maintain margins of stability during walking","volume":"28","author":"Hak","year":"2013","journal-title":"Clin. Biomech."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"055012","DOI":"10.1088\/1361-6579\/ab86d6","article-title":"A comprehensive guideline for Bland\u2013Altman and intra class correlation calculations to properly compare two methods of measurement and interpret findings","volume":"41","author":"Haghayegh","year":"2020","journal-title":"Physiol. Meas."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/23\/3\/1547\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T18:19:36Z","timestamp":1760120376000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/23\/3\/1547"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,1,31]]},"references-count":31,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2023,2]]}},"alternative-id":["s23031547"],"URL":"https:\/\/doi.org\/10.3390\/s23031547","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,1,31]]}}}