{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T02:14:57Z","timestamp":1760148897497,"version":"build-2065373602"},"reference-count":31,"publisher":"MDPI AG","issue":"12","license":[{"start":{"date-parts":[[2023,6,14]],"date-time":"2023-06-14T00:00:00Z","timestamp":1686700800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Canadian Foundation for Innovation","award":["36619","390178"],"award-info":[{"award-number":["36619","390178"]}]},{"name":"Natural Sciences and Engineering Research Council","award":["36619","390178"],"award-info":[{"award-number":["36619","390178"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>The ActiGraph GT9X has been implemented in clinical trials to track physical activity and sleep. Given recent incidental findings from our laboratory, the overall aim of this study was to notify academic and clinical researchers of the idle sleep mode (ISM) and inertial measurement unit (IMU)\u2019s interaction, as well as their subsequent effect on data acquisition. Investigations were undertaken using a hexapod robot to test the X, Y and Z sensing axes of the accelerometers. Seven GT9X were tested at frequencies ranging from 0.5 to 2 Hz. Testing was performed for three sets of setting parameters: Setting Parameter 1 (ISMONIMUON), Setting Parameter 2 (ISMOFFIMUON), Setting Parameter 3 (ISMONIMUOFF). The minimum, maximum and range of outputs were compared between the settings and frequencies. Findings indicated that Setting Parameters 1 and 2 were not significantly different, but both were significantly different from Setting Parameter 3. Upon inspection, it was discovered that the ISM was only active during Setting Parameter 3 testing, despite it being enabled in Setting Parameter 1. Researchers should be aware of this when conducting future research using the GT9X.<\/jats:p>","DOI":"10.3390\/s23125558","type":"journal-article","created":{"date-parts":[[2023,6,14]],"date-time":"2023-06-14T02:01:40Z","timestamp":1686708100000},"page":"5558","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Enabling the ActiGraph GT9X Link\u2019s Idle Sleep Mode and Inertial Measurement Unit Settings Directly Impacts Data Acquisition"],"prefix":"10.3390","volume":"23","author":[{"given":"Hannah J.","family":"Coyle-Asbil","sequence":"first","affiliation":[{"name":"Department of Human Health and Nutritional Sciences, University of Guelph, Guelph, ON N1G 2W1, Canada"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Janik","family":"Habegger","sequence":"additional","affiliation":[{"name":"School of Engineering, University of Guelph, Guelph, ON N1G 2W1, Canada"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0776-1235","authenticated-orcid":false,"given":"Michele","family":"Oliver","sequence":"additional","affiliation":[{"name":"School of Engineering, University of Guelph, Guelph, ON N1G 2W1, Canada"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lori Ann","family":"Vallis","sequence":"additional","affiliation":[{"name":"Department of Human Health and Nutritional Sciences, University of Guelph, Guelph, ON N1G 2W1, Canada"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2023,6,14]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"7772","DOI":"10.3390\/s100807772","article-title":"A review of accelerometry-based wearable motion detectors for physical activity monitoring","volume":"10","author":"Yang","year":"2010","journal-title":"Sensors"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"S311","DOI":"10.1139\/apnm-2016-0151","article-title":"Canadian 24-Hour Movement Guidelines for Children and Youth: An Integration of Physical Activity, Sedentary Behaviour, and Sleep","volume":"41","author":"Tremblay","year":"2016","journal-title":"Appl. Physiol. Nutr. Metab."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"429","DOI":"10.2217\/pme-2018-0044","article-title":"Wearables and the medical revolution","volume":"15","author":"Dunn","year":"2018","journal-title":"Pers. Med."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"e535","DOI":"10.1097\/TXD.0000000000000979","article-title":"Remote Therapy to Improve Outcomes in Lung Transplant Recipients: Design of the INSPIRE-III Randomized Clinical Trial","volume":"6","author":"Blumenthal","year":"2020","journal-title":"Transpl. Direct"},{"key":"ref_5","first-page":"e14221","article-title":"Feasibility, Acceptability, and Clinical Effectiveness of a Technology-Enabled Cardiac Rehabilitation Platform (Physical Activity Toward Health-I): Randomized Controlled Trial","volume":"22","author":"Claes","year":"2020","journal-title":"J. Med. Internet Res."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"R1","DOI":"10.1088\/0967-3334\/25\/2\/R01","article-title":"Accelerometry: Providing an integrated, practical method for long-term, ambulatory monitoring of human movement","volume":"25","author":"Mathie","year":"2004","journal-title":"Physiol. Meas."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"273","DOI":"10.1080\/1091367X.2014.942454","article-title":"Evaluating the Responsiveness of Accelerometry to Detect Change in Physical Activity","volume":"18","author":"Montoye","year":"2014","journal-title":"Meas. Phys. Educ. Exerc. Sci."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"311","DOI":"10.1016\/j.jsams.2011.12.001","article-title":"Everything you wanted to know about selecting the \u201cright\u201d Actigraph accelerometer cut-points for youth, but\u2026: A systematic review","volume":"15","author":"Kim","year":"2012","journal-title":"J. Sci. Med. Sport"},{"key":"ref_9","unstructured":"(2022, September 01). ActiGraph Launches GT9X Link Activity Monitor. ActiGraph. Available online: https:\/\/theactigraph.com\/actigraph-link\/."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"18901","DOI":"10.3390\/s150818901","article-title":"Tracking the Evolution of Smartphone Sensing for Monitoring Human Movement","volume":"15","author":"Redmond","year":"2015","journal-title":"Sensors"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"638","DOI":"10.3390\/s110100638","article-title":"Sensing movement: Microsensors for body motion measurement","volume":"11","author":"Zeng","year":"2011","journal-title":"Sensors"},{"key":"ref_12","unstructured":"ActiGraph Support Center (2018, November 08). Actigraph. Available online: https:\/\/actigraphcorp.force.com\/support\/s\/article\/Idle-Sleep-Mode-Explained."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"6378","DOI":"10.1109\/JSEN.2022.3150972","article-title":"Examining the Ability of Two Actigraph Models to Detect and Discriminate Between Low Frequency Movements","volume":"22","author":"Habegger","year":"2022","journal-title":"IEEE Sens. J."},{"key":"ref_14","unstructured":"(2015, April 28). Actigraph White Paper: What is the Utility of Inertial Motion Unit (IMU) Data?. Available online: https:\/\/s3.amazonaws.com\/actigraphcorp.com\/wp-content\/uploads\/2017\/11\/26205750\/ActiGraph_IMU_White_Paper.pdf."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"1036","DOI":"10.1080\/02640414.2020.1740469","article-title":"Development of raw acceleration cut-points for wrist and hip accelerometers to assess sedentary behaviour and physical activity in 5\u20137-year-old children","volume":"38","author":"Crotti","year":"2020","journal-title":"J. Sport. Sci."},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"Hurter, L., Fairclough, S.J., Knowles, Z.R., Porcellato, L.A., Cooper-Ryan, A.M., and Boddy, L.M. (2018). Establishing Raw Acceleration Thresholds to Classify Sedentary and Stationary Behaviour in Children. Children, 5.","DOI":"10.3390\/children5120172"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"1814","DOI":"10.1111\/sms.12795","article-title":"Evaluation of raw acceleration sedentary thresholds in children and adults","volume":"27","author":"Hildebrand","year":"2017","journal-title":"Scand. J. Med. Sci. Sport."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"261","DOI":"10.1038\/s41592-019-0686-2","article-title":"SciPy 1.0: Fundamental algorithms for scientific computing in Python","volume":"17","author":"Virtanen","year":"2020","journal-title":"Nat. Methods"},{"key":"ref_19","unstructured":"McKinney, W. (July, January 28). Data structures for statistical computing in python. Proceedings of the 9th Python in Science Conference, Austin, TX, USA."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"357","DOI":"10.1038\/s41586-020-2649-2","article-title":"Array programming with NumPy","volume":"585","author":"Harris","year":"2020","journal-title":"Nature"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"197","DOI":"10.1016\/j.sleep.2019.04.006","article-title":"Comparing measures of free-living sleep in school-aged children","volume":"60","author":"Brazendale","year":"2019","journal-title":"Sleep Med."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"247","DOI":"10.1080\/1091367X.2020.1801441","article-title":"Comparison of Free-Living and Laboratory Activity Outcomes from ActiGraph Accelerometers Worn on the Dominant and Non-Dominant Wrists","volume":"24","author":"Buchan","year":"2020","journal-title":"Meas. Phys. Educ. Exerc. Sci."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"2569","DOI":"10.1080\/02640414.2020.1794244","article-title":"Development of cut-points for determining activity intensity from a wrist-worn ActiGraph accelerometer in free-living adults","volume":"38","author":"Montoye","year":"2020","journal-title":"J. Sport. Sci."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"194","DOI":"10.1080\/1091367X.2020.1773827","article-title":"Cross-Generational Comparability of Raw and Count-Based Metrics from ActiGraph GT9X and wGT3X-BT Accelerometers during Free-Living in Youth","volume":"24","author":"Clevenger","year":"2020","journal-title":"Meas. Phys. Educ. Exerc. Sci."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"1093","DOI":"10.1249\/MSS.0000000000001532","article-title":"Estimating Energy Expenditure with ActiGraph GT9X Inertial Measurement Unit","volume":"50","author":"Hibbing","year":"2018","journal-title":"Med. Sci. Sport. Exerc."},{"key":"ref_26","first-page":"S29","article-title":"The Contribution of Gyroscope Data to Accelerometer Estimates of Free-living Physical Behavior Intensity [Conference abstract] (The 8th International Conference on Ambulatory Monitoring of Physical Activity and Movement)","volume":"4","author":"Marcotte","year":"2020","journal-title":"J. Meas. Phys. Beahviour"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"287","DOI":"10.1123\/jmpb.2021-0016","article-title":"Impact of ActiGraph Sampling Rate and Intermonitor Comparability on Measures of Physical Activity in Adults","volume":"4","author":"Clevenger","year":"2021","journal-title":"J. Meas. Phys. Behav."},{"key":"ref_28","doi-asserted-by":"crossref","unstructured":"Arvidsson, D., Fridolfsson, J., Buck, C., Ekblom, O., Ekblom-Bak, E., Lissner, L., Hunsberger, M., and Borjesson, M. (2019). Reexamination of Accelerometer Calibration with Energy Expenditure as Criterion: VO2net Instead of MET for Age-Equivalent Physical Activity Intensity. Sensors, 19.","DOI":"10.3390\/s19153377"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"774","DOI":"10.1038\/s41598-020-57648-w","article-title":"Factors associated with habitual time spent in different physical activity intensities using multiday accelerometry","volume":"10","author":"Jaeschke","year":"2020","journal-title":"Sci. Rep."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"e01193","DOI":"10.1016\/j.heliyon.2019.e01193","article-title":"Compliance with wrist-worn accelerometers in primiparous early postpartum women","volume":"5","author":"Wolpern","year":"2019","journal-title":"Heliyon"},{"key":"ref_31","doi-asserted-by":"crossref","unstructured":"Kuster, R.P., Hagstromer, M., Baumgartner, D., and Grooten, W.J.A. (2021). Concurrent and discriminant validity of ActiGraph waist and wrist cut-points to measure sedentary behaviour, activity level, and posture in office work. BMC Public Health, 21.","DOI":"10.1186\/s12889-021-10387-7"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/23\/12\/5558\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T19:54:28Z","timestamp":1760126068000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/23\/12\/5558"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,6,14]]},"references-count":31,"journal-issue":{"issue":"12","published-online":{"date-parts":[[2023,6]]}},"alternative-id":["s23125558"],"URL":"https:\/\/doi.org\/10.3390\/s23125558","relation":{},"ISSN":["1424-8220"],"issn-type":[{"type":"electronic","value":"1424-8220"}],"subject":[],"published":{"date-parts":[[2023,6,14]]}}}