{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,22]],"date-time":"2026-04-22T04:38:31Z","timestamp":1776832711762,"version":"3.51.2"},"reference-count":28,"publisher":"MDPI AG","issue":"2","license":[{"start":{"date-parts":[[2024,1,17]],"date-time":"2024-01-17T00:00:00Z","timestamp":1705449600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Zimmer Biomet and Bournemouth University"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Using tibial sensors in total knee replacements (TKRs) can enhance patient outcomes and reduce early revision surgeries, benefitting hospitals, the National Health Services (NHS), stakeholders, biomedical companies, surgeons, and patients. Having a sensor that is accurate, precise (over the whole surface), and includes a wide range of loads is important to the success of joint force tracking. This research aims to investigate the accuracy of a novel intraoperative load sensor for use in TKRs. This research used a self-developed load sensor and artificial intelligence (AI). The sensor is compatible with Zimmer\u2019s Persona Knee System and adaptable to other knee systems. Accuracy and precision were assessed, comparing medial\/lateral compartments inside\/outside the sensing area and below\/within the training load range. Five points were tested on both sides (medial and lateral), inside and outside of the sensing region, and with a range of loads. The average accuracy of the sensor was 83.41% and 84.63% for the load and location predictions, respectively. The highest accuracy, 99.20%, was recorded from inside the sensing area within the training load values, suggesting that expanding the training load range could enhance overall accuracy. The main outcomes were that (1) the load and location predictions were similar in accuracy and precision (p &gt; 0.05) in both compartments, (2) the accuracy and precision of both predictions inside versus outside of the triangular sensing area were comparable (p &gt; 0.05), and (3) there was a significant difference in the accuracy of load and location predictions (p &lt; 0.05) when the load applied was below the training loading range. The intraoperative load sensor demonstrated good accuracy and precision over the whole surface and over a wide range of load values. Minor improvements to the software could greatly improve the results of the sensor. Having a reliable and robust sensor could greatly improve advancements in all joint surgeries.<\/jats:p>","DOI":"10.3390\/s24020585","type":"journal-article","created":{"date-parts":[[2024,1,17]],"date-time":"2024-01-17T07:41:28Z","timestamp":1705477288000},"page":"585","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":9,"title":["Exploring the Performance of an Artificial Intelligence-Based Load Sensor for Total Knee Replacements"],"prefix":"10.3390","volume":"24","author":[{"ORCID":"https:\/\/orcid.org\/0009-0008-0175-8696","authenticated-orcid":false,"given":"Samira","family":"Al-Nasser","sequence":"first","affiliation":[{"name":"Bournemouth University, Fern Barrow, Poole BH12 3BB, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Siamak","family":"Noroozi","sequence":"additional","affiliation":[{"name":"Bournemouth University, Fern Barrow, Poole BH12 3BB, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Adrian","family":"Harvey","sequence":"additional","affiliation":[{"name":"Royal Bournemouth Hospital, Castle Ln E, Bournemouth BH7 7DW, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Navid","family":"Aslani","sequence":"additional","affiliation":[{"name":"Innovid Tech Ltd., 107b Athenlay Road, London SE15 3EJ, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Roya","family":"Haratian","sequence":"additional","affiliation":[{"name":"Bournemouth University, Fern Barrow, Poole BH12 3BB, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2024,1,17]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","unstructured":"Belluzzi, E., Todros, S., Pozzuoli, A., Ruggieri, P., Carniel, E.L., and Berardo, A. (2023). Human Cartilage Biomechanics: Experimental and Theoretical Approaches towards the Identification of Mechanical Properties in Healthy and Osteoarthritic Conditions. Processes, 11.","DOI":"10.3390\/pr11041014"},{"key":"ref_2","unstructured":"National Joint Registry (2024, January 14). 18th Annual NJR Report 2021, Available online: https:\/\/www.ncbi.nlm.nih.gov\/books\/NBK576858\/."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"197","DOI":"10.1302\/0301-620X.97B2.33707","article-title":"Financial analysis of revision knee surgery based on NHS tariffs and hospital costs","volume":"97-B","author":"Kallala","year":"2015","journal-title":"Bone Jt. J."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"e4","DOI":"10.2106\/JBJS.RVW.19.00008","article-title":"Intraoperative Sensing Technology to Achieve Balance in Primary Total Knee Arthroplasty: A Review of the Literature","volume":"7","author":"Ghirardelli","year":"2019","journal-title":"JBJS Rev."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"1774","DOI":"10.1016\/j.arth.2013.07.024","article-title":"Why are total knee arthroplasties failing today\u2014Has anything changed after 10 years?","volume":"29","author":"Sharkey","year":"2014","journal-title":"J. Arthroplast."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"955","DOI":"10.1016\/j.arth.2013.10.020","article-title":"A new method for defining balance: Promising short-term clinical outcomes of sensor-guided TKA","volume":"29","author":"Gustke","year":"2014","journal-title":"J. Arthroplast."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1007\/s11420-016-9533-5","article-title":"Comparison of Revision Rates of Non-modular Constrained Versus Posterior Stabilized Total Knee Arthroplasty: A Propensity Score Matched Cohort Study","volume":"13","author":"Moussa","year":"2017","journal-title":"HSS J."},{"key":"ref_8","first-page":"e26","article-title":"The relevance of ligament balancing in total knee arthroplasty: How important is it? A systematic review of the literature","volume":"1","author":"Babazadeh","year":"2009","journal-title":"Orthop. Rev."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"628695","DOI":"10.1155\/2014\/628695","article-title":"Primary TKA Patients with Quantifiably Balanced Soft-Tissue Achieve Significant Clinical Gains Sooner than Unbalanced Patients","volume":"2014","author":"Gustke","year":"2014","journal-title":"Adv. Orthop."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"290","DOI":"10.1016\/j.arth.2018.10.003","article-title":"How Accurately Can Soft Tissue Balance Be Determined in Total Knee Arthroplasty?","volume":"34","author":"MacDessi","year":"2019","journal-title":"J. Arthroplast."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"498","DOI":"10.1007\/s00167-020-05925-6","article-title":"Surgeon-defined assessment is a poor predictor of knee balance in total knee arthroplasty: A prospective, multicenter study","volume":"29","author":"MacDessi","year":"2021","journal-title":"Knee Surg. Sports Traumatol. Arthrosc."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"102","DOI":"10.1016\/j.arth.2016.03.054","article-title":"Can We Really \u201cFeel\u201d a Balanced Total Knee Arthroplasty?","volume":"31","author":"Elmallah","year":"2016","journal-title":"J. Arthroplast."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"1502","DOI":"10.1016\/j.arth.2016.12.019","article-title":"The Use of Electronic Sensor Device to Augment Ligament Balancing Leads to a Lower Rate of Arthrofibrosis After Total Knee Arthroplasty","volume":"32","author":"Geller","year":"2017","journal-title":"J. Arthroplast."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"1139","DOI":"10.1007\/s00264-017-3413-6","article-title":"Algorithmic pie-crusting of the medial collateral ligament guided by sensing technology affects the use of constrained inserts during total knee arthroplasty","volume":"41","author":"Amundsen","year":"2017","journal-title":"Int. Orthop."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"200","DOI":"10.1016\/j.artd.2017.11.001","article-title":"The effect of constraint on post damage in total knee arthroplasty: Posterior stabilized vs posterior stabilized constrained inserts","volume":"4","author":"Konopka","year":"2018","journal-title":"Arthroplast. Today"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"490","DOI":"10.1002\/1097-4636(200009)53:5<490::AID-JBM7>3.0.CO;2-7","article-title":"Effect of size and dose on bone resorption activity of macrophages by in vitro clinically relevant ultra high molecular weight polyethylene particles","volume":"53","author":"Green","year":"2000","journal-title":"J. Biomed. Mater. Res."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1002\/1097-4636(200101)54:1<12::AID-JBM2>3.0.CO;2-X","article-title":"In situ complement activation by polyethylene wear debris","volume":"54","author":"DeHeer","year":"2001","journal-title":"J. Biomed. Mater. Res."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"114","DOI":"10.1097\/01.blo.0000148783.20469.4c","article-title":"Wear, debris, and biologic activity of cross-linked polyethylene in the knee: Benefits and potential concerns","volume":"428","author":"Fisher","year":"2004","journal-title":"Clin. Orthop. Relat. Res."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"53","DOI":"10.5435\/00124635-200701000-00006","article-title":"Wear and osteolysis around total knee arthroplasty","volume":"15","author":"Naudie","year":"2007","journal-title":"JAAOS-J. Am. Acad. Orthop. Surg."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"1851","DOI":"10.1007\/s00167-023-07352-9","article-title":"Verasense sensor-assisted total knee arthroplasty showed no difference in range of motion, reoperation rate or functional outcomes when compared to manually balanced total knee arthroplasty: A systematic review","volume":"31","author":"Sava","year":"2023","journal-title":"Knee Surg Sports Traumatol. Arthrosc."},{"key":"ref_21","doi-asserted-by":"crossref","unstructured":"Nicolet-Petersen, S.J., Howell, S.M., and Hull, M.L. (2018). Tibial contact force and contact location errors of the VERASENSE. J. Biomech. Eng., 140.","DOI":"10.1115\/1.4040601"},{"key":"ref_22","doi-asserted-by":"crossref","unstructured":"Shah, D.S., Taylan, O., Verstraete, M., Berger, P., Vandenneucker, H., and Scheys, L. (2021). Can intraoperative intra-articular loads predict postoperative knee joint laxity following total knee arthroplasty? A cadaver study with smart tibial trays. Sensors, 21.","DOI":"10.3390\/s21155078"},{"key":"ref_23","unstructured":"Pramoditha, R. (2024, January 08). Overview of a Neural Network\u2019s Learning Process. Data Science 365. Available online: https:\/\/medium.com\/data-science-365\/overview-of-a-neural-networks-learning-process-61690a502fa."},{"key":"ref_24","doi-asserted-by":"crossref","unstructured":"Al-Nasser, S., Noroozi, S., Haratian, R., Aslani, N., and Harvey, A. (2023, January 12\u201314). Load Prediction using an Intraoperative Joint Sensor and Artificial Neural Network. Proceedings of the 19th International Conference on Condition Monitoring and Asset Management, CM 2023, Northampton, UK.","DOI":"10.1784\/cm2023.4f2"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"210","DOI":"10.1016\/j.knee.2023.03.020","article-title":"An electronic force sensor accurately detects increased but not decreased soft tissue tension in total knee arthroplasty","volume":"42","author":"Kuriyama","year":"2023","journal-title":"Knee"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"2100156","DOI":"10.1002\/aisy.202100156","article-title":"Novel Force Measurement System for Soft Tissue Balance in Total Knee Arthroplasty Based on Flexible Pressure Sensor Arrays","volume":"4","author":"Wang","year":"2022","journal-title":"Adv. Intell. Syst."},{"key":"ref_27","doi-asserted-by":"crossref","unstructured":"Jiang, H., Xiang, S., Guo, Y., and Wang, Z. (2019). A wireless visualized sensing system with prosthesis pose reconstruction for total knee arthroplasty. Sensors, 19.","DOI":"10.3390\/s19132909"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"1609","DOI":"10.1109\/TBME.2005.851504","article-title":"Development of a force amplitude- and location-sensing device designed to improve the ligament balancing procedure in TKA","volume":"52","author":"Crottet","year":"2005","journal-title":"IEEE Trans. Biomed. Eng."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/24\/2\/585\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T13:48:43Z","timestamp":1760104123000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/24\/2\/585"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,1,17]]},"references-count":28,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2024,1]]}},"alternative-id":["s24020585"],"URL":"https:\/\/doi.org\/10.3390\/s24020585","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,1,17]]}}}