{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,21]],"date-time":"2026-10-21T23:02:52Z","timestamp":1792623772311,"version":"4.5.0"},"reference-count":111,"publisher":"MDPI AG","issue":"14","license":[{"start":{"date-parts":[[2024,7,13]],"date-time":"2024-07-13T00:00:00Z","timestamp":1720828800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Pulmonary monitoring is crucial for the diagnosis and management of respiratory conditions, especially after the epidemic of coronavirus disease. Electrical impedance tomography (EIT) is an alternative non-radioactive tomographic imaging tool for monitoring pulmonary conditions. This review proffers the current EIT technical principles and applications on pulmonary monitoring, which gives a comprehensive summary of EIT applied on the chest and encourages its extensive usage to clinical physicians. The technical principles involving EIT instrumentations and image reconstruction algorithms are explained in detail, and the conditional selection is recommended based on clinical application scenarios. For applications, specifically, the monitoring of ventilation\/perfusion (V\/Q) is one of the most developed EIT applications. The matching correlation of V\/Q could indicate many pulmonary diseases, e.g., the acute respiratory distress syndrome, pneumothorax, pulmonary embolism, and pulmonary edema. Several recently emerging applications like lung transplantation are also briefly introduced as supplementary applications that have potential and are about to be developed in the future. In addition, the limitations, disadvantages, and developing trends of EIT are discussed, indicating that EIT will still be in a long-term development stage before large-scale clinical applications.<\/jats:p>","DOI":"10.3390\/s24144539","type":"journal-article","created":{"date-parts":[[2024,7,15]],"date-time":"2024-07-15T14:15:49Z","timestamp":1721052949000},"page":"4539","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":28,"title":["Technical Principles and Clinical Applications of Electrical Impedance Tomography in Pulmonary Monitoring"],"prefix":"10.3390","volume":"24","author":[{"given":"Ziqiang","family":"Cui","sequence":"first","affiliation":[{"name":"School of Electrical and Information Engineering, Tianjin University, Tianjin 300072, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xinyan","family":"Liu","sequence":"additional","affiliation":[{"name":"School of Electrical and Information Engineering, Tianjin University, Tianjin 300072, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hantao","family":"Qu","sequence":"additional","affiliation":[{"name":"School of Electrical and Information Engineering, Tianjin University, Tianjin 300072, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8792-0760","authenticated-orcid":false,"given":"Huaxiang","family":"Wang","sequence":"additional","affiliation":[{"name":"School of Electrical and Information Engineering, Tianjin University, Tianjin 300072, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2024,7,13]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1109\/TIM.2021.3123218","article-title":"Exploring Respiratory Motion Tracking Through Electrical Impedance Tomography","volume":"70","author":"Wang","year":"2021","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"ref_2","doi-asserted-by":"crossref","unstructured":"Frerichs, I., Zhao, Z., Dai, M., Braun, F., Proen\u00e7a, M., Rapin, M., Wacker, J., Lemay, M., Haris, K., and Petmezas, G. (2022). Respiratory Image Analysis. Wearable Sensing and Intelligent Data Analysis for Respiratory Management, Elsevier.","DOI":"10.1016\/B978-0-12-823447-1.00001-4"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"S895","DOI":"10.3233\/BME-151382","article-title":"Lung Carcinoma Recognition by Blood Dielectric Spectroscopy","volume":"26","author":"Chen","year":"2015","journal-title":"Bio-Med. Mater. Eng."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"250","DOI":"10.1109\/TBME.1978.326329","article-title":"An Impedance Camera for Spatially Specific Measurements of the Thorax","volume":"BME-25","author":"Henderson","year":"1978","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"415","DOI":"10.1016\/S0003-6870(99)00063-0","article-title":"Mechanical Impedance of the Human Body in Vertical Direction","volume":"31","author":"Holmlund","year":"2000","journal-title":"Appl. Ergon."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"401","DOI":"10.1016\/j.egypro.2016.05.053","article-title":"Calculation of Human Body Resistance at Power Frequency Using Anatomic Numerical Human Model","volume":"89","author":"Aga","year":"2016","journal-title":"Energy Procedia"},{"key":"ref_7","doi-asserted-by":"crossref","unstructured":"Biegelmeier, G. (1985). New knowledge on the impedance of the human body. Electrical Shock Safety Criteria, Elsevier.","DOI":"10.1016\/B978-0-08-025399-2.50014-X"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"390","DOI":"10.1109\/TBME.2010.2066273","article-title":"Assessment of Human Body Impedance for Safety Requirements Against Contact Currents for Frequencies up to 110 MHz","volume":"58","author":"Beeckman","year":"2011","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"8117","DOI":"10.1109\/JSEN.2018.2864539","article-title":"Development of a Portable Electrical Impedance Tomography System for Biomedical Applications","volume":"18","author":"Xu","year":"2018","journal-title":"IEEE Sens. J."},{"key":"ref_10","unstructured":"Modi, D. (November, January 30). IEC 601-1-2 and Its Impact on Medical Device Manufacturers. Proceedings of the 19th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. \u2018Magnificent Milestones and Emerging Opportunities in Medical Engineering\u2019 (Cat. No. 97CH36136), Chicago, IL, USA."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"A91","DOI":"10.1088\/0967-3334\/15\/2A\/013","article-title":"A Wide-Band AC-coupled Current Source for Electrical Impedance Tomography","volume":"15","author":"Bragos","year":"1994","journal-title":"Physiol. Meas."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"085107","DOI":"10.1063\/1.5028435","article-title":"A Floating Wide-Band Current Source for Electrical Impedance Tomography","volume":"89","author":"Khalighi","year":"2018","journal-title":"Rev. Sci. Instrum."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"999","DOI":"10.1088\/0967-3334\/30\/10\/001","article-title":"Comparison of a New Integrated Current Source with the Modified Howland Circuit for EIT Applications","volume":"30","author":"Hong","year":"2009","journal-title":"Physiol. Meas."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"1019","DOI":"10.1088\/0967-3334\/35\/6\/1019","article-title":"Crest Factor Optimization of the Multisine Waveform for Bioimpedance Spectroscopy","volume":"35","author":"Ojarand","year":"2014","journal-title":"Physiol. Meas."},{"key":"ref_15","doi-asserted-by":"crossref","unstructured":"Adler, A., and Holder, D. (2021). Electrical Impedance Tomography: Methods, History and Applications, CRC Press. [2nd ed.].","DOI":"10.1201\/9780429399886"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"991","DOI":"10.1513\/AnnalsATS.202005-562OC","article-title":"Prolonged Continuous Monitoring of Regional Lung Function in Infants with Respiratory Failure","volume":"19","author":"Becher","year":"2022","journal-title":"Ann. Am. Thorac. Soc."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"044004","DOI":"10.1088\/1361-6579\/aab513","article-title":"Clinical Performance of a Novel Textile Interface for Neonatal Chest Electrical Impedance Tomography","volume":"39","author":"Sophocleous","year":"2018","journal-title":"Physiol. Meas."},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Li, W., Shi, H., Zhang, L., Zhang, X., Zhang, F., and Yang, Y. (Biomed. Phys. Eng. Express, 2023). Electrical Impedance Tomography: A Review on Hardware Systems and Circuits, Biomed. Phys. Eng. Express, online ahead of print.","DOI":"10.1088\/2057-1976\/ad13a9"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"10016","DOI":"10.1109\/JSEN.2019.2927629","article-title":"A Dual-modality Integrated Sensor for Electrical Capacitance Tomography and Electromagnetic Tomography","volume":"19","author":"Cui","year":"2019","journal-title":"IEEE Sens. J."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"156","DOI":"10.1016\/j.sna.2007.06.036","article-title":"A Calculable Sensor for Electrical Impedance Tomography","volume":"140","author":"Cao","year":"2007","journal-title":"Sens. Actuators A Phys."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"1917","DOI":"10.1007\/s00134-012-2684-z","article-title":"Electrical Impedance Tomography: The Holy Grail of Ventilation and Perfusion Monitoring?","volume":"38","author":"Leonhardt","year":"2012","journal-title":"Intensive Care Med."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"A153","DOI":"10.1088\/0967-3334\/15\/2A\/020","article-title":"Image Reconstruction Using Non-Adjacent Drive Configurations (Electric Impedance Tomography)","volume":"15","author":"Avis","year":"1994","journal-title":"Physiol. Meas."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"713","DOI":"10.1097\/CCM.0b013e3181958d2f","article-title":"Principles of Electrical Impedance Tomography and Its Clinical Application","volume":"37","author":"Bodenstein","year":"2009","journal-title":"Crit. Care Med."},{"key":"ref_24","doi-asserted-by":"crossref","unstructured":"Putensen, C., Hentze, B., Muenster, S., and Muders, T. (2019). Electrical Impedance Tomography for Cardio-Pulmonary Monitoring. J. Clin. Med., 8.","DOI":"10.3390\/jcm8081176"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"094704","DOI":"10.1063\/5.0105317","article-title":"A New Current Injection and Voltage Measurement Strategy of 3D Electrical Impedance Tomography Based on Scanning Electrode","volume":"93","author":"Liu","year":"2022","journal-title":"Rev. Sci. Instrum."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"13530","DOI":"10.1109\/JSEN.2021.3068460","article-title":"Image Reconstruction Improvement with Optimal Driven-Measurement Pattern Selection for Electrical Impedance Tomography","volume":"21","author":"Yang","year":"2021","journal-title":"IEEE Sens. J."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"S101","DOI":"10.1088\/0967-3334\/29\/6\/S09","article-title":"A Measure of the Information Content of EIT Data","volume":"29","author":"Adler","year":"2008","journal-title":"Physiol. Meas."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1088\/0967-3334\/23\/1\/316","article-title":"A Comparison of Methods for Measurement of Spatial Resolution in Two-Dimensional Circular EIT Images","volume":"23","author":"Wheeler","year":"2002","journal-title":"Physiol. Meas."},{"key":"ref_29","doi-asserted-by":"crossref","unstructured":"Hu, C.L., Cheng, I.C., Huang, C.H., Liao, Y.T., Lin, W.C., Tsai, K.J., Chi, C.H., Chen, C.W., Wu, C.H., and Lin, I.T. (2021). Dry Wearable Textile Electrodes for Portable Electrical Impedance Tomography. Sensors, 21.","DOI":"10.3390\/s21206789"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"955","DOI":"10.1109\/TBME.2021.3110527","article-title":"Wearable Electrical Impedance Tomography Belt with Dry Electrodes","volume":"69","author":"Lin","year":"2022","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_31","doi-asserted-by":"crossref","unstructured":"Brabant, O.A., Byrne, D.P., Sacks, M., Moreno Martinez, F., Raisis, A.L., Araos, J.B., Waldmann, A.D., Schramel, J.P., Ambrosio, A., and Hosgood, G. (2022). Thoracic Electrical Impedance Tomography\u2014The 2022 Veterinary Consensus Statement. Front. Vet. Sci., 9.","DOI":"10.3389\/fvets.2022.946911"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"388","DOI":"10.1016\/j.advms.2021.07.010","article-title":"Electrical Impedance Tomography as a Tool for Monitoring Mechanical Ventilation. An Introduction to the Technique","volume":"66","author":"Maciejewski","year":"2021","journal-title":"Adv. Med Sci."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"064001","DOI":"10.1088\/1361-6579\/ac73d6","article-title":"Is There a Need for Individualized Adjustment of Electrode Belt Position during EIT-guided Titration of Positive End-Expiratory Pressure?","volume":"43","author":"Zhao","year":"2022","journal-title":"Physiol. Meas."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"7248","DOI":"10.1109\/JSEN.2022.3155476","article-title":"A Mismatch Correction Method for Electrode Offset in Electrical Impedance Tomography","volume":"22","author":"Shi","year":"2022","journal-title":"IEEE Sens. J."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"S103","DOI":"10.1088\/0967-3334\/27\/5\/S09","article-title":"Imaging of Conductivity Changes and Electrode Movement in EIT","volume":"27","author":"Soleimani","year":"2006","journal-title":"Physiol. Meas."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1088\/0967-3334\/16\/2\/004","article-title":"Errors in Prolonged Electrical Impedance Measurements Due to Electrode Repositioning and Postural Changes","volume":"16","author":"Lozano","year":"1995","journal-title":"Physiol. Meas."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"e12454","DOI":"10.1016\/j.heliyon.2022.e12454","article-title":"The Influence of Reference Electrode in Electrical Impedance Tomography","volume":"8","author":"Lin","year":"2022","journal-title":"Heliyon"},{"key":"ref_38","first-page":"1","article-title":"Estimation of Reference Voltages for Time-Difference Electrical Impedance Tomography","volume":"71","author":"Yu","year":"2022","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1136\/thoraxjnl-2016-208357","article-title":"Chest Electrical Impedance Tomography Examination, Data Analysis, Terminology, Clinical Use and Recommendations: Consensus Statement of the TRanslational EIT developmeNt study Group","volume":"72","author":"Frerichs","year":"2017","journal-title":"Thorax"},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"025703","DOI":"10.1088\/0957-0233\/27\/2\/025703","article-title":"A Sub-Domain Based Regularization Method with Prior Information for Human Thorax Imaging Using Electrical Impedance Tomography","volume":"27","author":"Kang","year":"2016","journal-title":"Meas. Sci. Technol."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"429","DOI":"10.1108\/SR-01-2016-0027","article-title":"A Review on Image Reconstruction Algorithms for Electrical Capacitance\/Resistance Tomography","volume":"36","author":"Cui","year":"2016","journal-title":"Sens. Rev."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"054503","DOI":"10.1117\/1.JMI.9.5.054503","article-title":"Hybrid Method for Improving Tikhonov-based Reconstruction Quality in Electrical Impedance Tomography","volume":"9","author":"Wang","year":"2022","journal-title":"J. Med Imaging"},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"542","DOI":"10.3934\/ipi.2022060","article-title":"Imaging of Conductivity Distribution Based on a Combined Reconstruction Method in Brain Electrical Impedance Tomography","volume":"17","author":"Shi","year":"2023","journal-title":"Inverse Probl. Imaging"},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"2157413","DOI":"10.1080\/27690911.2022.2157413","article-title":"An Efficient One-Step Proximal Method for EIT Sparse Reconstruction Based on Nonstationary Iterated Tikhonov Regularization","volume":"31","author":"Wang","year":"2023","journal-title":"Appl. Math. Sci. Eng."},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"3049","DOI":"10.1109\/JSEN.2019.2892179","article-title":"An Improved Tikhonov Regularization Method for Lung Cancer Monitoring Using Electrical Impedance Tomography","volume":"19","author":"Sun","year":"2019","journal-title":"IEEE Sens. J."},{"key":"ref_46","doi-asserted-by":"crossref","unstructured":"Hu, Q., Xu, Y., Liu, Z., Li, C., and Dong, F. (2021, January 17\u201320). Multiple Weighted Frequency-difference Method for Electrical Impedance Tomography. Proceedings of the 2021 IEEE International Instrumentation and Measurement Technology Conference (I2MTC), Glasgow, UK.","DOI":"10.1109\/I2MTC50364.2021.9459818"},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"27069","DOI":"10.1109\/ACCESS.2018.2836329","article-title":"Capacitively Coupled Resistivity Imaging for Biomaterial and Biomedical Applications","volume":"6","author":"Jiang","year":"2018","journal-title":"IEEE Access"},{"key":"ref_48","doi-asserted-by":"crossref","unstructured":"Cao, L., Li, H., Xu, C., Dai, M., Ji, Z., Shi, X., Dong, X., Fu, F., and Yang, B. (2019). A Novel Time-Difference Electrical Impedance Tomography Algorithm Using Multi-Frequency Information. BioMedical Eng. OnLine, 18.","DOI":"10.1186\/s12938-019-0703-9"},{"key":"ref_49","doi-asserted-by":"crossref","unstructured":"Bai, X., Liu, D., Wei, J., Bai, X., Sun, S., and Tian, W. (2021). Simultaneous Imaging of Bio- and Non-Conductive Targets by Combining Frequency and Time Difference Imaging Methods in Electrical Impedance Tomography. Biosensors, 11.","DOI":"10.3390\/bios11060176"},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"1176","DOI":"10.1088\/1361-6579\/aa63d7","article-title":"EIT Imaging of Admittivities with a D-bar Method and Spatial Prior: Experimental Results for Absolute and Difference Imaging","volume":"38","author":"Hamilton","year":"2017","journal-title":"Physiol. Meas."},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"442","DOI":"10.1016\/j.arcontrol.2019.05.002","article-title":"A Review of Electrical Impedance Tomography in Lung Applications: Theory and Algorithms for Absolute Images","volume":"48","author":"Martins","year":"2019","journal-title":"Annu. Rev. Control"},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"064005","DOI":"10.1088\/1361-6579\/aac8b1","article-title":"Robust Computation in 2D Absolute EIT (a-EIT) Using D-bar Methods with the \u2018Exp\u2019 Approximation","volume":"39","author":"Hamilton","year":"2018","journal-title":"Physiol. Meas."},{"key":"ref_53","doi-asserted-by":"crossref","first-page":"2367","DOI":"10.1109\/TMI.2018.2828303","article-title":"Deep D-Bar: Real-Time Electrical Impedance Tomography Imaging with Deep Neural Networks","volume":"37","author":"Hamilton","year":"2018","journal-title":"IEEE Trans. Med. Imaging"},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"074002","DOI":"10.1088\/1361-6579\/ab21b2","article-title":"Beltrami-Net: Domain-Independent Deep D-bar Learning for Absolute Imaging with Electrical Impedance Tomography (a-EIT)","volume":"40","author":"Hamilton","year":"2019","journal-title":"Physiol. Meas."},{"key":"ref_55","doi-asserted-by":"crossref","first-page":"044004","DOI":"10.1088\/1361-6579\/ab14aa","article-title":"Comparing D-bar and Common Regularization-Based Methods for Electrical Impedance Tomography","volume":"40","author":"Hamilton","year":"2019","journal-title":"Physiol. Meas."},{"key":"ref_56","doi-asserted-by":"crossref","unstructured":"Khan, T.A., and Ling, S.H. (2019). Review on Electrical Impedance Tomography: Artificial Intelligence Methods and Its Applications. Algorithms, 12.","DOI":"10.3390\/a12050088"},{"key":"ref_57","doi-asserted-by":"crossref","first-page":"196","DOI":"10.1109\/JSEN.2018.2876411","article-title":"Image Reconstruction Based on Convolutional Neural Network for Electrical Resistance Tomography","volume":"19","author":"Tan","year":"2019","journal-title":"IEEE Sens. J."},{"key":"ref_58","doi-asserted-by":"crossref","first-page":"2546","DOI":"10.1109\/TBME.2019.2891676","article-title":"Dominant-Current Deep Learning Scheme for Electrical Impedance Tomography","volume":"66","author":"Wei","year":"2019","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_59","doi-asserted-by":"crossref","first-page":"9277","DOI":"10.1109\/JSEN.2021.3050845","article-title":"Shape Reconstruction with Multiphase Conductivity for Electrical Impedance Tomography Using Improved Convolutional Neural Network Method","volume":"21","author":"Wu","year":"2021","journal-title":"IEEE Sens. J."},{"key":"ref_60","first-page":"1","article-title":"V-Shaped Dense Denoising Convolutional Neural Network for Electrical Impedance Tomography","volume":"71","author":"Zhang","year":"2022","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"ref_61","doi-asserted-by":"crossref","unstructured":"Li, X., Zhang, R., Wang, Q., Duan, X., Sun, Y., and Wang, J. (2023). SAR-CGAN: Improved Generative Adversarial Network for EIT Reconstruction of Lung Diseases. Biomed. Signal Process. Control, 81.","DOI":"10.1016\/j.bspc.2022.104421"},{"key":"ref_62","doi-asserted-by":"crossref","first-page":"3105","DOI":"10.1109\/JBHI.2021.3059016","article-title":"Inferring Respiratory and Circulatory Parameters from Electrical Impedance Tomography with Deep Recurrent Models","volume":"25","author":"Strodthoff","year":"2021","journal-title":"IEEE J. Biomed. Health Inform."},{"key":"ref_63","doi-asserted-by":"crossref","unstructured":"Crivellari, B., Raisis, A., Hosgood, G., Waldmann, A.D., Murphy, D., and Mosing, M. (2021). Use of Electrical Impedance Tomography (EIT) to Estimate Tidal Volume in Anaesthetized Horses Undergoing Elective Surgery. Animals, 11.","DOI":"10.3390\/ani11051350"},{"key":"ref_64","doi-asserted-by":"crossref","unstructured":"Kim, Y.Z., Choi, H.Y., Choi, Y.S., Kim, C.Y., Lee, Y.J., and Chung, S.H. (2022). Surfactant Treatment Shows Higher Correlation Between Ventilator and EIT Tidal Volumes in an RDS Animal Model. Front. Physiol., 13.","DOI":"10.3389\/fphys.2022.814320"},{"key":"ref_65","doi-asserted-by":"crossref","unstructured":"Koz\u0142owska, N., Wierzbicka, M., Jasi\u0144ski, T., and Domino, M. (2022). Advances in the Diagnosis of Equine Respiratory Diseases: A Review of Novel Imaging and Functional Techniques. Animals, 12.","DOI":"10.3390\/ani12030381"},{"key":"ref_66","doi-asserted-by":"crossref","first-page":"222","DOI":"10.1111\/evj.12998","article-title":"Monitoring of Tidal Ventilation by Electrical Impedance Tomography in Anaesthetised Horses","volume":"51","author":"Mosing","year":"2019","journal-title":"Equine Vet. J."},{"key":"ref_67","doi-asserted-by":"crossref","first-page":"282","DOI":"10.1159\/000193994","article-title":"Assessment of Changes in Distribution of Lung Perfusion by Electrical Impedance Tomography","volume":"77","author":"Frerichs","year":"2009","journal-title":"Respiration"},{"key":"ref_68","doi-asserted-by":"crossref","first-page":"e434","DOI":"10.1016\/j.bja.2020.08.001","article-title":"Bedside Monitoring of Lung Perfusion by Electrical Impedance Tomography in the Time of COVID-19","volume":"125","author":"Gibson","year":"2020","journal-title":"Br. J. Anaesth."},{"key":"ref_69","doi-asserted-by":"crossref","unstructured":"Xu, M., He, H., and Long, Y. (2021). Lung Perfusion Assessment by Bedside Electrical Impedance Tomography in Critically Ill Patients. Front. Physiol., 12.","DOI":"10.3389\/fphys.2021.748724"},{"key":"ref_70","doi-asserted-by":"crossref","first-page":"646","DOI":"10.1109\/TMI.2002.800585","article-title":"Regional Lung Perfusion as Determined by Electrical Impedance Tomography in Comparison with Electron Beam CT Imaging","volume":"21","author":"Frerichs","year":"2002","journal-title":"IEEE Trans. Med. Imaging"},{"key":"ref_71","doi-asserted-by":"crossref","first-page":"134","DOI":"10.1186\/s13613-021-00921-6","article-title":"Three Broad Classifications of Acute Respiratory Failure Etiologies Based on Regional Ventilation and Perfusion by Electrical Impedance Tomography: A Hypothesis-Generating Study","volume":"11","author":"He","year":"2021","journal-title":"Ann. Intensive Care"},{"key":"ref_72","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1109\/TMI.2020.3025080","article-title":"Regional Lung Perfusion Analysis in Experimental ARDS by Electrical Impedance and Computed Tomography","volume":"40","author":"Kircher","year":"2021","journal-title":"IEEE Trans. Med. Imaging"},{"key":"ref_73","doi-asserted-by":"crossref","first-page":"695","DOI":"10.1088\/0967-3334\/33\/5\/695","article-title":"A Review on Electrical Impedance Tomography for Pulmonary Perfusion Imaging","volume":"33","author":"Nguyen","year":"2012","journal-title":"Physiol. Meas."},{"key":"ref_74","doi-asserted-by":"crossref","unstructured":"Slobod, D., Damia, A., Leali, M., Spinelli, E., and Mauri, T. (2022). Pathophysiology and Clinical Meaning of Ventilation-Perfusion Mismatch in the Acute Respiratory Distress Syndrome. Biology, 12.","DOI":"10.3390\/biology12010067"},{"key":"ref_75","doi-asserted-by":"crossref","first-page":"66","DOI":"10.1097\/MCC.0000000000000905","article-title":"Advanced Respiratory Monitoring in Mechanically Ventilated Patients with Coronavirus Disease 2019-Associated Acute Respiratory Distress Syndrome","volume":"28","author":"Somhorst","year":"2022","journal-title":"Curr. Opin. Crit. Care"},{"key":"ref_76","doi-asserted-by":"crossref","first-page":"384","DOI":"10.1164\/rccm.201808-1551LE","article-title":"Electrical Impedance Tomography Can Identify Ventilation and Perfusion Defects: A Neonatal Case","volume":"199","author":"Tingay","year":"2019","journal-title":"Am. J. Respir. Crit. Care Med."},{"key":"ref_77","unstructured":"Nguyen, D.T., Thiagalingam, A., Bhaskaran, A., Barry, M.A., Pouliopoulos, J., Jin, C., and McEwan, A.L. (2014, January 26\u201330). Electrical Impedance Tomography for Assessing Ventilation\/Perfusion Mismatch for Pulmonary Embolism Detection without Interruptions in Respiration. Proceedings of the 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Chicago, IL, USA."},{"key":"ref_78","doi-asserted-by":"crossref","first-page":"192","DOI":"10.1186\/s13054-021-03615-4","article-title":"Unmatched Ventilation and Perfusion Measured by Electrical Impedance Tomography Predicts the Outcome of ARDS","volume":"25","author":"Spinelli","year":"2021","journal-title":"Crit. Care"},{"key":"ref_79","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1186\/s13054-018-2195-6","article-title":"Electrical Impedance Tomography in Acute Respiratory Distress Syndrome","volume":"22","author":"Bachmann","year":"2018","journal-title":"Crit. Care"},{"key":"ref_80","doi-asserted-by":"crossref","first-page":"590","DOI":"10.4187\/respcare.07076","article-title":"Distribution of Ventilation Measured by Electrical Impedance Tomography in Critically Ill Children","volume":"65","author":"Inany","year":"2020","journal-title":"Respir. Care"},{"key":"ref_81","doi-asserted-by":"crossref","unstructured":"Di Pierro, M., Giani, M., Bronco, A., Lembo, F.M., Rona, R., Bellani, G., and Foti, G. (2022). Bedside Selection of Positive End Expiratory Pressure by Electrical Impedance Tomography in Patients Undergoing Veno-Venous Extracorporeal Membrane Oxygenation Support: A Comparison between COVID-19 ARDS and ARDS from Other Etiologies. J. Clin. Med., 11.","DOI":"10.3390\/jcm11061639"},{"key":"ref_82","doi-asserted-by":"crossref","first-page":"678","DOI":"10.1186\/s13054-020-03414-3","article-title":"Electrical Impedance Tomography to Titrate Positive End-Expiratory Pressure in COVID-19 Acute Respiratory Distress Syndrome","volume":"24","author":"Perier","year":"2020","journal-title":"Crit. Care"},{"key":"ref_83","doi-asserted-by":"crossref","first-page":"865","DOI":"10.1001\/jama.2010.218","article-title":"Higher vs Lower Positive End-Expiratory Pressure in Patients with Acute Lung Injury and Acute Respiratory Distress Syndrome: Systematic Review and Meta-analysis","volume":"303","author":"Briel","year":"2010","journal-title":"JAMA"},{"key":"ref_84","doi-asserted-by":"crossref","first-page":"158","DOI":"10.1111\/cpf.12385","article-title":"A Spiky Pattern in the Course of Electrical Thoracic Impedance as a Very Early Sign of a Developing Pneumothorax","volume":"38","author":"Cambiaghi","year":"2018","journal-title":"Clin. Physiol. Funct. Imaging"},{"key":"ref_85","doi-asserted-by":"crossref","first-page":"1574","DOI":"10.1002\/ccr3.2944","article-title":"Electrical Impedance Tomography Reveals Pathophysiology of Neonatal Pneumothorax during NAVA","volume":"8","author":"Kallio","year":"2020","journal-title":"Clin. Case Rep."},{"key":"ref_86","doi-asserted-by":"crossref","first-page":"707","DOI":"10.1152\/japplphysiol.00973.2018","article-title":"Electrical Impedance Tomography Identifies a Distinct Change in Regional Phase Angle Delay Pattern in Ventilation Filling Immediately Prior to a Spontaneous Pneumothorax","volume":"127","author":"Miedema","year":"2019","journal-title":"J. Appl. Physiol."},{"key":"ref_87","doi-asserted-by":"crossref","first-page":"629","DOI":"10.1007\/s10877-022-00935-w","article-title":"Bedside Electrical Impedance Tomography in Early Diagnosis of Pneumothorax in Mechanically Ventilated ICU Patients\u2014A Single-Center Retrospective Cohort Study","volume":"37","author":"Yang","year":"2022","journal-title":"J. Clin. Monit. Comput."},{"key":"ref_88","doi-asserted-by":"crossref","unstructured":"Girrbach, F., Landeck, T., Schneider, D., Reske, S.U., Hempel, G., Hammerm\u00fcller, S., Gottschaldt, U., Salz, P., Noreikat, K., and Stehr, S.N. (2020). Detection of Posttraumatic Pneumothorax Using Electrical Impedance Tomography\u2014An Observer-Blinded Study in Pigs with Blunt Chest Trauma. PLoS ONE, 15.","DOI":"10.1371\/journal.pone.0227518"},{"key":"ref_89","doi-asserted-by":"crossref","first-page":"025003","DOI":"10.1088\/1361-6579\/ac4830","article-title":"An Efficient and Fast Multi-Band Focused Bioimpedance Solution with EIT-based Reconstruction for Pulmonary Embolism Assessment: A Simulation Study from Massive to Segmental Blockage","volume":"43","author":"McEwan","year":"2022","journal-title":"Physiol. Meas."},{"key":"ref_90","doi-asserted-by":"crossref","first-page":"1297","DOI":"10.1088\/0967-3334\/36\/6\/1297","article-title":"Perfusion Redistribution after a Pulmonary-Embolism-like Event with Contrast Enhanced EIT","volume":"36","author":"Nguyen","year":"2015","journal-title":"Physiol. Meas."},{"key":"ref_91","doi-asserted-by":"crossref","first-page":"e0843","DOI":"10.1097\/CCE.0000000000000843","article-title":"Electrical Impedance Tomography as a Bedside Diagnostic Tool for Pulmonary Embolism","volume":"5","author":"Prins","year":"2023","journal-title":"Crit. Care Explor."},{"key":"ref_92","doi-asserted-by":"crossref","unstructured":"Sobota, V., and Suchomel, J. (2013, January 21\u201323). Monitoring of Pulmonary Embolism Using Electrical Impedance Tomography: A Case Study. Proceedings of the 2013 E-Health and Bioengineering Conference (EHB), Iasi, Romania.","DOI":"10.1109\/EHB.2013.6707415"},{"key":"ref_93","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1177\/2045894020984043","article-title":"Rapid Dynamic Bedside Assessment of Pulmonary Perfusion Defect by Electrical Impedance Tomography in a Patient with Acute Massive Pulmonary Embolism","volume":"11","author":"Yuan","year":"2021","journal-title":"Pulm. Circ."},{"key":"ref_94","doi-asserted-by":"crossref","first-page":"e01606","DOI":"10.1213\/XAA.0000000000001606","article-title":"Bedside Diagnosis of Pulmonary Embolism Using Electrical Impedance Tomography: A Case Report","volume":"16","author":"Kuk","year":"2022","journal-title":"A&A Pract."},{"key":"ref_95","doi-asserted-by":"crossref","unstructured":"Wang, X., Zhao, H., and Cui, N. (2021). The Role of Electrical Impedance Tomography for Management of High-Risk Pulmonary Embolism in a Postoperative Patient. Front. Med., 8.","DOI":"10.3389\/fmed.2021.773471"},{"key":"ref_96","doi-asserted-by":"crossref","first-page":"1695","DOI":"10.1378\/chest.116.6.1695","article-title":"Electrical Impedance Tomography in the Assessment of Extravascular Lung Water in Noncardiogenic Acute Respiratory Failure","volume":"116","author":"Kunst","year":"1999","journal-title":"Chest"},{"key":"ref_97","unstructured":"Arad, M., and Abboud, S. (2013, January 22\u201325). Electrical Impedance Tomography vs. Whole Thoracic Impedance for Monitoring Lung Fluid Content in Congestive Heart Failure Patients. Proceedings of the Computing in Cardiology 2013, Zaragoza, Spain."},{"key":"ref_98","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1186\/s13054-015-1173-5","article-title":"Electrical Impedance Tomography (EIT) for Quantification of Pulmonary Edema in Acute Lung Injury","volume":"20","author":"Trepte","year":"2016","journal-title":"Crit. Care"},{"key":"ref_99","doi-asserted-by":"crossref","first-page":"1713","DOI":"10.1164\/rccm.202008-3058LE","article-title":"Effect of Positive End-Expiratory Pressure and Proning on Ventilation and Perfusion in COVID-19 Acute Respiratory Distress Syndrome","volume":"202","author":"Perier","year":"2020","journal-title":"Am. J. Respir. Crit. Care Med."},{"key":"ref_100","doi-asserted-by":"crossref","first-page":"723","DOI":"10.1097\/CCM.0000000000005450","article-title":"Effects of Prone Position on Lung Recruitment and Ventilation-Perfusion Matching in Patients with COVID-19 Acute Respiratory Distress Syndrome: A Combined CT Scan\/Electrical Impedance Tomography Study","volume":"50","author":"Fossali","year":"2022","journal-title":"Crit. Care Med."},{"key":"ref_101","doi-asserted-by":"crossref","unstructured":"Pierrakos, C., van der Ven, F.L.I.M., Smit, M.R., Hagens, L.A., Paulus, F., Schultz, M.J., and Bos, L.D.J. (2022). Prone Positioning Decreases Inhomogeneity and Improves Dorsal Compliance in Invasively Ventilated Spontaneously Breathing COVID-19 Patients\u2014A Study Using Electrical Impedance Tomography. Diagnostics, 12.","DOI":"10.3390\/diagnostics12102281"},{"key":"ref_102","doi-asserted-by":"crossref","first-page":"154","DOI":"10.1186\/s13054-022-04021-0","article-title":"Prone Positioning Improves Ventilation\u2013Perfusion Matching Assessed by Electrical Impedance Tomography in Patients with ARDS: A Prospective Physiological Study","volume":"26","author":"Wang","year":"2022","journal-title":"Crit. Care"},{"key":"ref_103","doi-asserted-by":"crossref","first-page":"1352","DOI":"10.1007\/s11748-021-01676-4","article-title":"Successful Lung Transplantation after Prone Positioning in an Ineligible Donor: A Case Report","volume":"69","author":"Son","year":"2021","journal-title":"Gen. Thorac. Cardiovasc. Surg."},{"key":"ref_104","doi-asserted-by":"crossref","first-page":"A59","DOI":"10.1088\/0967-3334\/15\/2A\/008","article-title":"Bioelectrical Spectroscopy from Multi-Frequency EIT","volume":"15","author":"Griffiths","year":"1994","journal-title":"Physiol. Meas."},{"key":"ref_105","doi-asserted-by":"crossref","unstructured":"Edd, J., and Rubinsky, B. (2006, January 17\u201318). Assessment of the Viability of Transplant Organs with 3D Electrical Impedance Tomography. Proceedings of the 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference, Shanghai, China.","DOI":"10.1109\/IEMBS.2005.1617013"},{"key":"ref_106","doi-asserted-by":"crossref","unstructured":"Jiang, H., Han, Y., Zheng, X., and Fang, Q. (2022). Roles of Electrical Impedance Tomography in Lung Transplantation. Front. Physiol., 13.","DOI":"10.3389\/fphys.2022.986422"},{"key":"ref_107","doi-asserted-by":"crossref","first-page":"2471207","DOI":"10.1155\/2016\/2471207","article-title":"Single-Lung Transplant Results in Position Dependent Changes in Regional Ventilation: An Observational Case Series Using Electrical Impedance Tomography","volume":"2016","author":"Ramanathan","year":"2016","journal-title":"Can. Respir. J."},{"key":"ref_108","doi-asserted-by":"crossref","first-page":"896","DOI":"10.1097\/ALN.0000000000003059","article-title":"Bedside Evaluation of Pulmonary Embolism by Electrical Impedance Tomography","volume":"132","author":"Grassi","year":"2020","journal-title":"Anesthesiology"},{"key":"ref_109","doi-asserted-by":"crossref","first-page":"311","DOI":"10.1097\/MCC.0000000000000823","article-title":"Weaning Patients with Obesity from Ventilatory Support","volume":"27","author":"Kacmarek","year":"2021","journal-title":"Curr. Opin. Crit. Care"},{"key":"ref_110","doi-asserted-by":"crossref","first-page":"402","DOI":"10.1186\/s13063-018-2777-2","article-title":"High Flow Nasal Oxygen after Bariatric Surgery (OXYBAR), Prophylactic Post-Operative High Flow Nasal Oxygen versus Conventional Oxygen Therapy in Obese Patients Undergoing Bariatric Surgery: Study Protocol for a Randomised Controlled Pilot Trial","volume":"19","author":"Fulton","year":"2018","journal-title":"Trials"},{"key":"ref_111","doi-asserted-by":"crossref","first-page":"526","DOI":"10.1007\/s11307-021-01700-2","article-title":"Imaging Pulmonary Blood Vessels and Ventilation-Perfusion Mismatch in COVID-19","volume":"24","author":"Tipre","year":"2022","journal-title":"Mol. Imaging Biol."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/24\/14\/4539\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T15:16:17Z","timestamp":1760109377000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/24\/14\/4539"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,7,13]]},"references-count":111,"journal-issue":{"issue":"14","published-online":{"date-parts":[[2024,7]]}},"alternative-id":["s24144539"],"URL":"https:\/\/doi.org\/10.3390\/s24144539","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,7,13]]}}}