{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,9]],"date-time":"2025-10-09T17:43:33Z","timestamp":1760031813691,"version":"build-2065373602"},"reference-count":21,"publisher":"MDPI AG","issue":"7","license":[{"start":{"date-parts":[[2025,3,24]],"date-time":"2025-03-24T00:00:00Z","timestamp":1742774400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Nasopharyngeal ventilation (NPV) is a common technique used to support breathing, particularly when a patient\u2019s respiration is inadequate, such as under sedation. It involves delivering oxygen through an endotracheal tube positioned above the glottis. Accurate tidal volume measurement is crucial for anesthesiologists, with the gold standard being a pneumotachograph. However, due to leakage from the mouth or mask, this method has limitations when applied to NPV. This study introduces a computational model that calculates respiratory flow in real time by accounting for leak flow. Results show that tidal volume measurements using this method are comparable to the gold standard, assuming the model\u2019s assumptions hold true.<\/jats:p>","DOI":"10.3390\/s25072022","type":"journal-article","created":{"date-parts":[[2025,3,24]],"date-time":"2025-03-24T06:21:38Z","timestamp":1742797298000},"page":"2022","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["A New Computational Method for Detecting Leak Flow and Tidal Volume Waveforms During Spontaneous or Mandatory Breathing Assisted with Nasopharyngeal Ventilation"],"prefix":"10.3390","volume":"25","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-7372-282X","authenticated-orcid":false,"given":"Francesco","family":"Montecchia","sequence":"first","affiliation":[{"name":"Medical Engineering Laboratory, Department of Civil Engineering and Computer Science Engineering, University of Rome \u201cTor Vergata\u201d, 1 Politecnico Street, 00133 Rome, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Paola","family":"Papoff","sequence":"additional","affiliation":[{"name":"Pediatric Intensive Care Unit, Department of Pediatrics, Sapienza University of Rome, 00100 Rome, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2025,3,24]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"540","DOI":"10.1164\/ajrccm.163.2.9906116","article-title":"Noninvasive ventilation","volume":"163","author":"Mehta","year":"2001","journal-title":"Am. J. Respir. Crit. Care Med."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"2400396","DOI":"10.1183\/13993003.00396-2024","article-title":"Clinical review of non-invasive ventilation","volume":"64","author":"Criner","year":"2024","journal-title":"Eur. Respir. J."},{"key":"ref_3","first-page":"e39049","article-title":"Nasopharyngeal ventilation compared to facemask ventilation: A prospective, randomized, crossover trial in two different elective cohorts","volume":"15","author":"Lenhardt","year":"2023","journal-title":"Cureus"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"809","DOI":"10.1111\/pan.14194","article-title":"Nasopharyngeal tubes in pediatric anesthesia: Is the flow-dependent pressure drop across the tube suitable for calculating oropharyngeal pressure ?","volume":"31","author":"Papoff","year":"2021","journal-title":"Pediatr. Anaesth."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"423","DOI":"10.1002\/(SICI)1099-0496(199712)24:6<423::AID-PPUL7>3.0.CO;2-H","article-title":"Respiratory mechanics during mechanical ventilation: A model study on the effect of leak around a tracheal tube","volume":"24","author":"Kondo","year":"1997","journal-title":"Pediatr. Pulmonol."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"1116","DOI":"10.1111\/j.1651-2227.2009.01319.x","article-title":"Relationship between endotracheal tube leakage and under-reading of tidal volume in neonatal ventilators","volume":"98","author":"Mohmoud","year":"2009","journal-title":"Acta Pediatr."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"31s","DOI":"10.1183\/09031936.03.00050403","article-title":"Mechanical ventilation: Invasive versus noninvasive","volume":"22","author":"Brochard","year":"2003","journal-title":"Eur. Respir. J."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"902","DOI":"10.1183\/09031936.00170508","article-title":"Evaluating noninvasive ventilation using a monitoring system coupled to a ventilator: A bench-to-bedside study","volume":"34","author":"Rabec","year":"2009","journal-title":"Eur. Respir. J."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"1934","DOI":"10.1007\/s00134-009-1651-9","article-title":"Is volume and leak monitoring feasible during nasopharyngeal continuous positive airway pressure in neonates?","volume":"35","author":"Fischer","year":"2009","journal-title":"Intensive Care Med."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"1477","DOI":"10.1016\/j.rmed.2009.04.020","article-title":"Clinical impact of leak compensation during non-invasive ventilation","volume":"103","author":"Storre","year":"2009","journal-title":"Respir. Med."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1016\/j.medengphy.2018.02.004","article-title":"A flow-leak correction algorithm for pneumotachographic work-of-breathing measurements during high-flow nasal cannula oxygen therapy","volume":"54","author":"Montecchia","year":"2018","journal-title":"Med. Eng. Phys."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"124","DOI":"10.1016\/j.medengphy.2008.05.002","article-title":"Comparison of different techniques to measure air leak during CPAP treatment in neonates","volume":"31","author":"Schmalisch","year":"2009","journal-title":"Med. Eng. Phys."},{"key":"ref_13","doi-asserted-by":"crossref","unstructured":"Vicario, F., Alkhairy, S., Buizza, R., and Truschel, W.A. (2017, January 11\u201315). Two-parameters leak estimation in non-invasive ventilation. Proceedings of the 39th Annual International Conference of IEEE Engineering in Medicine and Biology Society (EMBS), Jeju, Republic of Korea.","DOI":"10.1109\/EMBC.2017.8036785"},{"key":"ref_14","doi-asserted-by":"crossref","unstructured":"Quiao, H., Liu, T., Yin, J., and Zhang, Q.I. (2020). The detection and estimation of the air leakage in noninvasive ventilation: Platform study. J. Mech. Med. Biol., 20.","DOI":"10.1142\/S0219519420400436"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"1187","DOI":"10.1152\/jappl.1998.85.3.1187","article-title":"Leak measurements in spontaneously breathing premature newborns by using the flow-through technique","volume":"85","author":"Foitzik","year":"1998","journal-title":"J. App. Physiol."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"241","DOI":"10.4187\/respcare.02616","article-title":"Acomparison of leak compensation during pediatric noninvasive ventilation: A lung model study","volume":"59","author":"Oto","year":"2014","journal-title":"Respir. Care"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"285","DOI":"10.1007\/s10877-015-9716-5","article-title":"Real time noninvasive estimation of work of breathing using facemask leak-corrected tidal volume during noninvasive pressure support: Validation study","volume":"30","author":"Banner","year":"2016","journal-title":"J. Clin. Monit. Comput."},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Montecchia, F., and Papoff, P. (2024). Real-Time Optimal Flow Setting and Respiratory Profile Evaluation in Infants Treated with High-Flow Nasal Cannula (HFNC). Fluids, 9.","DOI":"10.3390\/fluids9040093"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"225","DOI":"10.1007\/BF01681259","article-title":"Flow resistance in human air passages and the effect of irregular branching of the bronchial system on the respiratory process in various regions of the lungs","volume":"162","author":"Rohrer","year":"1915","journal-title":"Arch. Ges. Physiol."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"723","DOI":"10.1038\/s41372-019-0333-x","article-title":"Tidal volume transmission during non-synchronized nasal intermittent positive pressure ventilation via RAM cannula","volume":"39","author":"Matlock","year":"2019","journal-title":"J. Perinatol."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1186\/s40635-023-00553-z","article-title":"Diaphragm excursions as proxy for tidal volume during spontaneous breathing in invasively ventilated ICU patients","volume":"11","author":"Janssen","year":"2023","journal-title":"Intensive Care Med. Exp."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/25\/7\/2022\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,9]],"date-time":"2025-10-09T16:59:05Z","timestamp":1760029145000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/25\/7\/2022"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,3,24]]},"references-count":21,"journal-issue":{"issue":"7","published-online":{"date-parts":[[2025,4]]}},"alternative-id":["s25072022"],"URL":"https:\/\/doi.org\/10.3390\/s25072022","relation":{},"ISSN":["1424-8220"],"issn-type":[{"type":"electronic","value":"1424-8220"}],"subject":[],"published":{"date-parts":[[2025,3,24]]}}}