{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T01:07:46Z","timestamp":1760058466704,"version":"build-2065373602"},"reference-count":23,"publisher":"MDPI AG","issue":"8","license":[{"start":{"date-parts":[[2025,4,8]],"date-time":"2025-04-08T00:00:00Z","timestamp":1744070400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>This research utilizes a self-developed inertial sensor in conjunction with a motion tracking system and four Smart Bands to record a runner\u2019s movements and extract parameters such as step numbers, length, and frequencies at different running speeds. The data obtained were processed to find the number of steps taken. These steps were also recorded by an IMU (inertial measurement unit) and motion tracking system (MoCap\u2014Motion Capturing) and used to compare the different systems and find their agreement at different running speeds. The results show a very strong correlation between the IMU and the motion tracking system with r2 = 0.968 at 6 km\/h, r2 = 0.991 at 8 km\/h, r2 = 0.991 at 10 km\/h, and r2 = 0.996 at 12 km\/h. The Xiaomi Mi Band 2 showed an r2 = 0.861 at 6 km\/h, r2 = 0.985 at 8 km\/h, r2 = 0.977 at 10 km\/h, and r2 = 0.987 at 12 km\/h and can therefore be considered a good replacement for an IMU.<\/jats:p>","DOI":"10.3390\/s25082354","type":"journal-article","created":{"date-parts":[[2025,4,9]],"date-time":"2025-04-09T03:32:53Z","timestamp":1744169573000},"page":"2354","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Comparison of Smart Bands with MEMS and Motion Tracking Systems Used in Running"],"prefix":"10.3390","volume":"25","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9331-7431","authenticated-orcid":false,"given":"Andy","family":"Stamm","sequence":"first","affiliation":[{"name":"Faculty of Technology & Bionics, Rhine-Waal University of Applied Sciences, 47533 Cleve, Germany"},{"name":"School of Engineering and Built Environment, Griffith University, Nathan 4111, QLD, Australia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ronny","family":"Hartanto","sequence":"additional","affiliation":[{"name":"Faculty of Technology & Bionics, Rhine-Waal University of Applied Sciences, 47533 Cleve, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5709-8948","authenticated-orcid":false,"given":"Noah","family":"Becker","sequence":"additional","affiliation":[{"name":"School of Engineering and Built Environment, Griffith University, Nathan 4111, QLD, Australia"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2025,4,8]]},"reference":[{"key":"ref_1","unstructured":"Wang, J.R., and Parameswaran, N. (2004, January 1). Survey of sports video analysis: Research issues and applications. Proceedings of the Pan-Sydney Area Workshop on Visual Information Processing, Sydney, Australia."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"554","DOI":"10.1007\/s00421-003-0906-3","article-title":"Variability of gait patterns during unconstrained walking assessed by satellite positioning (GPS)","volume":"90","author":"Terrier","year":"2003","journal-title":"Eur. J. Appl. Physiol."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1007\/s12283-010-0043-2","article-title":"Validation of trunk mounted inertial sensors for analysing running biomechanics under field conditions, using synchronously collected foot contact data","volume":"12","author":"Wixted","year":"2010","journal-title":"Sports Eng."},{"key":"ref_4","doi-asserted-by":"crossref","unstructured":"Alonge, F., Cucco, E., Ippolito, F., and Pulizzotto, A. (2014). The Use of Accelerometers and Gyroscopes to Estimate Hip and Knee Angles on Gait Analysis. Sensors, 14.","DOI":"10.3390\/s140508430"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1016\/S1350-4533(99)00030-2","article-title":"A practical gait analysis system using gyroscopes","volume":"21","author":"Tong","year":"1999","journal-title":"Med. Eng. Phys."},{"key":"ref_6","doi-asserted-by":"crossref","unstructured":"Stamm, A., and Hartanto, R. (2018). Feature Extraction from MEMS Accelerometer and Motion Tracking Measurements in Comparison with Smart Bands during Running. Proceedings, 2.","DOI":"10.3390\/proceedings2060197"},{"key":"ref_7","first-page":"57709","article-title":"Creating a treadmill running video game with smartwatch interaction","volume":"83","author":"Chover","year":"2024","journal-title":"Multimed. Tools Appl."},{"key":"ref_8","doi-asserted-by":"crossref","unstructured":"Pirscoveanu, C.-I., and Oliveira, A.S. (2023). Sensitiveness of Variables Extracted from a Fitness Smartwatch to Detect Changes in Vertical Impact Loading during Outdoors Running. Sensors, 23.","DOI":"10.3390\/s23062928"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"13028","DOI":"10.1109\/ACCESS.2017.2702066","article-title":"A Smartwatch Step Counter for Slow and Intermittent Ambulation","volume":"5","author":"Genovese","year":"2017","journal-title":"IEEE Access"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"312","DOI":"10.3906\/elk-2102-138","article-title":"Stressed or just running? Differentiation of mental stress and physical activityby using machine learning","volume":"30","author":"Can","year":"2022","journal-title":"Turk. J. Electr. Eng. Comput. Sci."},{"key":"ref_11","first-page":"13","article-title":"Daniel Arthur James. The inertial sensor: A base platform for wider adoption in sport science applications","volume":"4","author":"Hugo","year":"2015","journal-title":"J. Fit. Res."},{"key":"ref_12","unstructured":"U.N.O. (2017, December 01). LTX6. Available online: https:\/\/benysports.de\/manuals\/Bedienungsanleitung_LTX6PRO_DE_2016.pdf."},{"key":"ref_13","unstructured":"FitBit (2017, December 01). Alta. Available online: https:\/\/www.fitbit.com\/uk\/alta#features."},{"key":"ref_14","unstructured":"Samsung (2017, December 01). Gear Fit SM-R350. Available online: https:\/\/www.samsung.com\/de\/support\/model\/SM-R3500ZKASEB\/."},{"key":"ref_15","unstructured":"Vidonn (2017, December 01). X6. Available online: https:\/\/img.banggood.com\/file\/products\/20150304003054Vidonn%20x6.pdf."},{"key":"ref_16","unstructured":"Xiaomi (2017, December 01). MiBand 2. Available online: http:\/\/www.mi.com\/en\/miband2\/."},{"key":"ref_17","unstructured":"OptiTrack (2017, December 01). Prime 13. Available online: http:\/\/optitrack.com\/products\/prime-13\/."},{"key":"ref_18","unstructured":"OptiTrack (2017, December 01). Motive. Available online: http:\/\/optitrack.com\/products\/motive\/."},{"key":"ref_19","doi-asserted-by":"crossref","unstructured":"Lai, A., James, D.A., Hayes, J.P., and Harvey, E.C. (2004, January 13\u201315). Semi-automatic calibration technique using six inertial frames of reference. Proceedings of the Microelectronics: Design, Technology, and Packaging, Perth, Australia.","DOI":"10.1117\/12.530199"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"522","DOI":"10.1016\/j.proeng.2015.07.236","article-title":"Investigating Forward Velocity and Symmetry in Freestyle Swimming Using Inertial Sensors","volume":"112","author":"Stamm","year":"2015","journal-title":"Procedia Eng."},{"key":"ref_21","doi-asserted-by":"crossref","unstructured":"Benson, L.C., R\u00e4is\u00e4nen, A.M., Clermont, C.A., and Ferber, R. (2022). Is This the Real Life, or Is This Just Laboratory? A Scoping Review of IMU-Based Running Gait Analysis. Sensors, 22.","DOI":"10.3390\/s22051722"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1016\/j.jbiomech.2019.01.004","article-title":"New considerations for collecting biomechanical data using wearable sensors: Number of level runs to define a stable running pattern with a single IMU","volume":"85","author":"Benson","year":"2019","journal-title":"J. Biomech."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"481","DOI":"10.1109\/JSEN.2007.891947","article-title":"Measurement of Energy Expenditure in Elite Athletes Using MEMS-Based Triaxial Accelerometers","volume":"7","author":"Wixted","year":"2007","journal-title":"IEEE Sens. J."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/25\/8\/2354\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,9]],"date-time":"2025-10-09T17:12:37Z","timestamp":1760029957000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/25\/8\/2354"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,4,8]]},"references-count":23,"journal-issue":{"issue":"8","published-online":{"date-parts":[[2025,4]]}},"alternative-id":["s25082354"],"URL":"https:\/\/doi.org\/10.3390\/s25082354","relation":{},"ISSN":["1424-8220"],"issn-type":[{"type":"electronic","value":"1424-8220"}],"subject":[],"published":{"date-parts":[[2025,4,8]]}}}