{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,8]],"date-time":"2026-10-08T09:47:27Z","timestamp":1791452847635,"version":"4.3.3"},"reference-count":55,"publisher":"MDPI AG","issue":"12","license":[{"start":{"date-parts":[[2025,6,14]],"date-time":"2025-06-14T00:00:00Z","timestamp":1749859200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"MedTeq"},{"name":"Mitacs"},{"name":"Healthy Brains, Healthy Lives (HBHL)"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Advancements in remote gait analysis technologies enable efficient, cost-effective, and personalized real-time assessments at home. This study aims to contribute evidence as to the comparability of gait quality metrics of three methods of remote gait assessment in individuals with Parkinson\u2019s disease (PD): (1) observation, (2) a wearable sensor, and (3) pose estimation. A cross-sectional, multiple case series study was conducted remotely. Twenty participants submitted videos performing a modified TUG test with the Heel2ToeTM wearable. Each video was analysed by six raters using the checklist specific to PD developed for this study and the MediaPipe Pose Landmarker task estimation library. The observational ratings agreed with the Heel2ToeTM on detecting heel strike 64% of the time and 28.5% of the time on detecting push-off. The difference in the ranks of paired observations based on the Wilcoxon signed rank sum test between the pairs of methods compared was significant for all parameters, except for push-off when estimates from MediaPipe were compared to the ratings from the Observational Checklist, W = 86 (p = 0.498). A combination of digital technologies for remote gait analysis, such as wearable sensors and pose estimation, can detect subtle nuances in gait impairments that may be overlooked by the human eye.<\/jats:p>","DOI":"10.3390\/s25123733","type":"journal-article","created":{"date-parts":[[2025,6,16]],"date-time":"2025-06-16T06:40:27Z","timestamp":1750056027000},"page":"3733","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Comparability of Methods for Remotely Assessing Gait Quality"],"prefix":"10.3390","volume":"25","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8524-3284","authenticated-orcid":false,"given":"Natasha","family":"Hassija","sequence":"first","affiliation":[{"name":"Center for Outcomes Research and Evaluation (CORE), Research Institute of McGill University Health Center (MUHC), Montreal, QC H4A 3S5, Canada"},{"name":"Department of Medicine, School of Physical and Occupational Therapy, Faculty of Medicine, McGill University, QC H3A 0G4, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Edward","family":"Hill","sequence":"additional","affiliation":[{"name":"PhysioBiometrics Inc., Montreal, QC H2V 1P4, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2933-5213","authenticated-orcid":false,"given":"Helen","family":"Dawes","sequence":"additional","affiliation":[{"name":"PhysioBiometrics Inc., Montreal, QC H2V 1P4, Canada"},{"name":"NIHR Exeter, Biomedical Research Centre, Medical School, University of Exeter, Exeter  EX4 4QJ, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nancy E.","family":"Mayo","sequence":"additional","affiliation":[{"name":"Center for Outcomes Research and Evaluation (CORE), Research Institute of McGill University Health Center (MUHC), Montreal, QC H4A 3S5, Canada"},{"name":"Department of Medicine, School of Physical and Occupational Therapy, Faculty of Medicine, McGill University, QC H3A 0G4, Canada"},{"name":"PhysioBiometrics Inc., Montreal, QC H2V 1P4, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2025,6,14]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","unstructured":"Nguyen, G., King, K., and Stirling, L. (2023). Telerehabilitation use and experiences in occupational and physical therapy through the early stages of the COVID-19 pandemic. PLoS ONE, 18.","DOI":"10.1371\/journal.pone.0291605"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"e43615","DOI":"10.2196\/43615","article-title":"Technologies in Home-Based Digital Rehabilitation: Scoping Review","volume":"10","author":"Arntz","year":"2023","journal-title":"JMIR Rehabil. Assist. Technol."},{"key":"ref_3","doi-asserted-by":"crossref","unstructured":"Bernhardsson, S., Larsson, A., Bergenheim, A., Ho-Henriksson, C.-M., Ekhammar, A., Lange, E., Larsson, M.E.H., Nordeman, L., Samsson, K.S., and Bornh\u00f6ft, L. (2023). Digital physiotherapy assessment vs conventional face-to-face physiotherapy assessment of patients with musculoskeletal disorders: A systematic review. PLoS ONE, 18.","DOI":"10.1371\/journal.pone.0283013"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"193","DOI":"10.17305\/bjbms.2012.2484","article-title":"Gait disorder rehabilitation using vision and non-vision based sensors: A systematic review","volume":"12","author":"Ali","year":"2012","journal-title":"Bosn. J. Basic Med. Sci."},{"key":"ref_5","doi-asserted-by":"crossref","unstructured":"Okochi, J., Takahashi, T., Takamuku, K., and Escorpizo, R. (2013). Staging of mobility, transfer and walking functions of elderly persons based on the codes of the International Classification of Functioning, Disability and Health. BMC Geriatr., 13.","DOI":"10.1186\/1471-2318-13-16"},{"key":"ref_6","doi-asserted-by":"crossref","unstructured":"Hendriks, M.M.S., Vos-Van Der Hulst, M., Weijs, R.W.J., Van Lotringen, J.H., Geurts, A.C.H., and Keijsers, N.L.W. (2022). Using Sensor Technology to Measure Gait Capacity and Gait Performance in Rehabilitation Inpatients with Neurological Disorders. Sensors, 22.","DOI":"10.3390\/s22218387"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1016\/j.jclinepi.2017.04.013","article-title":"Montreal Accord on Patient-Reported Outcomes (PROs) use series\u2014Paper 2: Terminology proposed to measure what matters in health","volume":"89","author":"Mayo","year":"2017","journal-title":"J. Clin. Epidemiol."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1586\/erp.11.12","article-title":"Interpreting patient-reported outcome results: US FDA guidance and emerging methods","volume":"11","author":"McLeod","year":"2011","journal-title":"Expert Rev. Pharmacoeconomics Outcomes Res."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"e207958","DOI":"10.1212\/WNL.0000000000207958","article-title":"FDA Patient-Focused Drug Development Guidances","volume":"102","author":"Berg","year":"2024","journal-title":"Neurology"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1016\/j.jval.2016.11.005","article-title":"Clinician-Reported Outcome Assessments of Treatment Benefit: Report of the ISPOR Clinical Outcome Assessment Emerging Good Practices Task Force","volume":"20","author":"Powers","year":"2017","journal-title":"Value Health"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"143","DOI":"10.7224\/1537-2073.2019-047","article-title":"Clinically Assessed Walking Capacity Versus Real-World Walking Performance in People with Multiple Sclerosis","volume":"22","author":"Mate","year":"2020","journal-title":"Int. J. MS Care"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"1575","DOI":"10.1249\/MSS.0b013e31821ece12","article-title":"2011 Compendium of Physical Activities","volume":"43","author":"Ainsworth","year":"2011","journal-title":"Med. Sci. Sports Exerc."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"74","DOI":"10.1016\/j.gaitpost.2007.10.004","article-title":"Quantity versus quality of gait and quality of life in patients with osteoarthritis","volume":"28","author":"Brandes","year":"2008","journal-title":"Gait Posture"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"e13889","DOI":"10.2196\/13889","article-title":"Real-Time Auditory Feedback\u2013Induced Adaptation to Walking Among Seniors Using the Heel2Toe Sensor: Proof-of-Concept Study","volume":"6","author":"Mate","year":"2019","journal-title":"JMIR Rehabil. Assist. Technol."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"1078","DOI":"10.1093\/gerona\/glx187","article-title":"Everyday Stepping Quantity and Quality Among Older Adult Fallers With and Without Mild Cognitive Impairment: Initial Evidence for New Motor Markers of Cognitive Deficits?","volume":"73","author":"Hausdorff","year":"2018","journal-title":"J. Gerontol. Ser. A"},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"Keren, K., Busse, M., Fritz, N.E., Muratori, L.M., Gazit, E., Hillel, I., Scheinowitz, M., Gurevich, T., Inbar, N., and Omer, N. (2021). Quantification of Daily-Living Gait Quantity and Quality Using a Wrist-Worn Accelerometer in Huntington\u2019s Disease. Front. Neurol., 12.","DOI":"10.3389\/fneur.2021.719442"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1007\/PL00012205","article-title":"Gait analysis techniques","volume":"2","author":"Kyriazis","year":"2001","journal-title":"J. Orthop. Traumatol."},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Brunnekreef, J.J., Van Uden, C.J., Van Moorsel, S., and Kooloos, J.G. (2005). Reliability of videotaped observational gait analysis in patients with orthopedic impairments. BMC Musculoskelet. Disord., 6.","DOI":"10.1186\/1471-2474-6-17"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"204","DOI":"10.1016\/j.hlpt.2019.12.004","article-title":"Gait quantification and visualization for digital healthcare","volume":"9","author":"Anwary","year":"2020","journal-title":"Health Policy Technol."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"3362","DOI":"10.3390\/s140203362","article-title":"Gait Analysis Methods: An Overview of Wearable and Non-Wearable Systems, Highlighting Clinical Applications","volume":"14","year":"2014","journal-title":"Sensors"},{"key":"ref_21","doi-asserted-by":"crossref","unstructured":"Shanahan, C.J., Boonstra, F.M.C., Cofr\u00e9 Lizama, L.E., Strik, M., Moffat, B.A., Khan, F., Kilpatrick, T.J., Van Der Walt, A., Galea, M.P., and Kolbe, S.C. (2018). Technologies for Advanced Gait and Balance Assessments in People with Multiple Sclerosis. Front. Neurol., 8.","DOI":"10.3389\/fneur.2017.00708"},{"key":"ref_22","doi-asserted-by":"crossref","unstructured":"Ferrari, V., Mar\u00edn-Jim\u00e9nez, M., and Zisserman, A. (2009). 2D Human Pose Estimation in TV Shows, Springer.","DOI":"10.1007\/978-3-642-03061-1_7"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"2255","DOI":"10.3390\/s120202255","article-title":"Gait Analysis Using Wearable Sensors","volume":"12","author":"Tao","year":"2012","journal-title":"Sensors"},{"key":"ref_24","doi-asserted-by":"crossref","unstructured":"Guk, K., Han, G., Lim, J., Jeong, K., Kang, T., Lim, E.-K., and Jung, J. (2019). Evolution of Wearable Devices with Real-Time Disease Monitoring for Personalized Healthcare. Nanomaterials, 9.","DOI":"10.3390\/nano9060813"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1200\/EDBK_238919","article-title":"The Future of Wearable Technologies and Remote Monitoring in Health Care","volume":"39","author":"Liao","year":"2019","journal-title":"Am. Soc. Clin. Oncol. Educ. Book"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"2093","DOI":"10.1002\/jor.24950","article-title":"Comparison of wearable sensor to traditional methods in functional outcome measures: A systematic review\u2014PubMed","volume":"39","author":"Dohm","year":"2021","journal-title":"J. Orthop. Res. Off. Publ. Orthop. Res. Soc."},{"key":"ref_27","doi-asserted-by":"crossref","unstructured":"Santone, A., Amato, F., Esposito, F., Cesarelli, M., Donisi, L., Prisco, G., and Pirozzi, M.A. (2024). Validity of Wearable Inertial Sensors for Gait Analysis: A Systematic Review\u2014PubMed. Diagnostics, 15.","DOI":"10.3390\/diagnostics15010036"},{"key":"ref_28","doi-asserted-by":"crossref","unstructured":"Menychtas, D., Petrou, N., Kansizoglou, I., Giannakou, E., Grekidis, A., Gasteratos, A., Gourgoulis, V., Douda, E., Smilios, I., and Michalopoulou, M. (2023). Frontiers | Gait analysis comparison between manual marking, 2D pose estimation algorithms, and 3D marker-based system. Front. Rehabil. Sci., 4.","DOI":"10.3389\/fresc.2023.1238134"},{"key":"ref_29","doi-asserted-by":"crossref","unstructured":"Hii, C.S.T., Gan, K.B., Zainal, N., Mohamed Ibrahim, N., Azmin, S., Mat Desa, S.H., Van De Warrenburg, B., and You, H.W. (2023). Quantitative Gait Analysis Using a Pose-Estimation Algorithm with a Single 2D-Video of Parkinson\u2019s Disease Pa. Sensors, 23.","DOI":"10.3390\/s23146489"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"026113","DOI":"10.1063\/1.3147408","article-title":"Gait dynamics in Parkinson\u2019s disease: Common and distinct behavior among stride length, gait variability, and fractal-like scaling","volume":"19","author":"Hausdorff","year":"2009","journal-title":"Chaos"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"465","DOI":"10.1093\/ptj\/71.6.465","article-title":"Interrater Reliability of Videotaped Observational Gait-Analysis Assessments","volume":"71","author":"Eastlack","year":"1991","journal-title":"Phys. Ther."},{"key":"ref_32","doi-asserted-by":"crossref","unstructured":"Guo, Y., Yang, J., Liu, Y., Chen, X., and Yang, G.-Z. (2022). Detection and assessment of Parkinson\u2019s disease based on gait analysis: A survey. Front. Aging Neurosci., 14.","DOI":"10.3389\/fnagi.2022.916971"},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"1027","DOI":"10.1093\/ptj\/65.7.1027","article-title":"Reliability of Observational Kinematic Gait Analysis","volume":"65","author":"Krebs","year":"1985","journal-title":"Phys. Ther."},{"key":"ref_34","doi-asserted-by":"crossref","unstructured":"Ridao-Fern\u00e1ndez, C., Pinero-Pinto, E., and Chamorro-Moriana, G. (2019). Observational Gait Assessment Scales in Patients with Walking Disorders: Systematic Review. BioMed Res. Int., 2019.","DOI":"10.1155\/2019\/2085039"},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"89","DOI":"10.1016\/j.jns.2003.09.005","article-title":"Clinical gait and balance scale (GABS): Validation and utilization","volume":"217","author":"Thomas","year":"2004","journal-title":"J. Neurol. Sci."},{"key":"ref_36","unstructured":"Rancho Los Amigos National Rehabilitation Center (1989). Observational Gait Analysis Handbook, Professional Staff Association, Rancho Los Amigos Medical Center."},{"key":"ref_37","doi-asserted-by":"crossref","unstructured":"Vadnerkar, A., Figueiredo, S., Mayo, N.E., and Kearney, R.E. (2014, January 26\u201330). Classification of gait quality for biofeedback to improve heel-to-toe gait. Proceedings of the 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Chicago, IL, USA.","DOI":"10.1109\/EMBC.2014.6944408"},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"140","DOI":"10.1109\/JBHI.2017.2665519","article-title":"Design and Validation of a Biofeedback Device to Improve Heel-to-Toe Gait in Seniors","volume":"22","author":"Vadnerkar","year":"2018","journal-title":"IEEE J. Biomed. Health Inform."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"14","DOI":"10.1016\/j.gaitpost.2020.06.031","article-title":"A new approach toward gait training in patients with Parkinson\u2019s Disease","volume":"81","author":"Carvalho","year":"2020","journal-title":"Gait Posture"},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1186\/s40814-024-01542-z","article-title":"Real-time Auditory Feedback for Improving Gait and Walking in People with Parkinson\u2019s Disease: A Pilot and Feasibility Trial","volume":"10","author":"Mayo","year":"2024","journal-title":"Pilot Feasibility Stud."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"156","DOI":"10.1038\/s41746-023-00905-9","article-title":"Using AI to measure Parkinson\u2019s disease severity at home","volume":"6","author":"Islam","year":"2023","journal-title":"NPJ Digit. Med."},{"key":"ref_42","doi-asserted-by":"crossref","unstructured":"Connie, T., Aderinola, T.B., Ong, T.S., Goh, M.K.O., Erfianto, B., and Purnama, B. (2022). Pose-Based Gait Analysis for Diagnosis of Parkinson\u2019s Disease. Algorithms, 15.","DOI":"10.3390\/a15120474"},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"112826","DOI":"10.1016\/j.measurement.2023.112826","article-title":"Reliability and validity analysis of MediaPipe-based measurement system for some human rehabilitation motions","volume":"214","author":"Latreche","year":"2023","journal-title":"Measurement"},{"key":"ref_44","doi-asserted-by":"crossref","unstructured":"Ramesh, S.H., Lemaire, E.D., Tu, A., Cheung, K., and Baddour, N. (2023). Automated Implementation of the Edinburgh Visual Gait Score (EVGS) Using OpenPose and Handheld Smartphone Video. Sensors, 23.","DOI":"10.3390\/s23104839"},{"key":"ref_45","doi-asserted-by":"crossref","unstructured":"Yang, Y., Liu, P., Sun, Y., Yu, N., Wu, J., and Han, J. (2021, January 26\u201328). A Video-Based Method to Classify Abnormal Gait for Remote Screening of Parkinson\u2019s Disease. Proceedings of the 2021 40th Chinese Control Conference (CCC), Shanghai, China.","DOI":"10.23919\/CCC52363.2021.9549992"},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"345","DOI":"10.1187\/cbe.13-04-0082","article-title":"The Other Half of the Story: Effect Size Analysis in Quantitative Research","volume":"12","author":"Maher","year":"2013","journal-title":"CBE\u2014Life Sci. Educ."},{"key":"ref_47","first-page":"767","article-title":"The Symbol Digit Modalities Test: Normative data from a large nationally representative sample of Australians\u2014PubMed","volume":"29","author":"Watson","year":"2014","journal-title":"Arch. Clin. Neuropsychol. Off. J. Natl. Acad. Neuropsychol."},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"102952","DOI":"10.1016\/j.artmed.2024.102952","article-title":"Automatic two-dimensional & three-dimensional video analysis with deep learning for movement disorders: A systematic review","volume":"156","author":"Tang","year":"2024","journal-title":"Artif. Intell. Med."},{"key":"ref_49","doi-asserted-by":"crossref","unstructured":"Hulleck, A.A., Menoth Mohan, D., Abdallah, N., El Rich, M., and Khalaf, K. (2022). Present and future of gait assessment in clinical practice: Towards the application of novel trends and technologies. Front. Med. Technol., 4.","DOI":"10.3389\/fmedt.2022.901331"},{"key":"ref_50","unstructured":"Norman, G.R., and Streiner, D.L. (2008). Biostatistics: The Bare Essentials, PMPH USA (BC Decker)."},{"key":"ref_51","doi-asserted-by":"crossref","unstructured":"Kim, J., Kim, R., Byun, K., Kang, N., and Park, K. (2025). Assessment of temporospatial and kinematic gait parameters using human pose estimation in patients with Parkinson\u2019s disease: A comparison between near-frontal and lateral views. PLoS ONE, 20.","DOI":"10.1371\/journal.pone.0317933"},{"key":"ref_52","doi-asserted-by":"crossref","unstructured":"Yamamoto, M., Shimatani, K., Ishige, Y., Takemura, H., Yamamoto, M., Shimatani, K., Ishige, Y., and Takemura, H. (2022). Verification of gait analysis method fusing camera-based pose estimation and an IMU sensor in various gait conditions. Sci. Rep., 12.","DOI":"10.1038\/s41598-022-22246-5"},{"key":"ref_53","first-page":"1271","article-title":"Quantitative Gait Analysis Using a Pose-Estimation Algorithm with a Single 2D-Video of Parkinson\u2019s Disease Patients","volume":"11","author":"Shin","year":"2021","journal-title":"J. Park. Dis."},{"key":"ref_54","first-page":"898","article-title":"Quantifying frontal plane knee motion during single limb squats: Reliability and validity of 2-dimensional measures","volume":"9","author":"Gwynne","year":"2014","journal-title":"Int. J. Sports Phys. Ther."},{"key":"ref_55","first-page":"163","article-title":"Two-dimensional video analysis is comparable to 3d motion capture in lower extremity movement assessment","volume":"12","author":"Schurr","year":"2017","journal-title":"Int. J. Sports Phys. Ther."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/25\/12\/3733\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,9]],"date-time":"2025-10-09T17:52:11Z","timestamp":1760032331000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/25\/12\/3733"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,6,14]]},"references-count":55,"journal-issue":{"issue":"12","published-online":{"date-parts":[[2025,6]]}},"alternative-id":["s25123733"],"URL":"https:\/\/doi.org\/10.3390\/s25123733","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,6,14]]}}}