{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,13]],"date-time":"2026-10-13T21:49:11Z","timestamp":1791928151118,"version":"4.3.4"},"reference-count":58,"publisher":"MDPI AG","issue":"14","license":[{"start":{"date-parts":[[2025,7,10]],"date-time":"2025-07-10T00:00:00Z","timestamp":1752105600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Parkinson\u2019s disease (PD) is a neurodegenerative disorder commonly marked by upper limb tremors that interfere with daily activities. Wearable devices, such as smartwatches, represent a promising solution for continuous and objective monitoring in PD. This study aimed to develop and validate a tremor-detection algorithm using smartwatch sensors. Data were collected from 21 individuals with PD and 27 healthy controls using both a commercial inertial measurement unit (G-Sensor, BTS Bioengineering, Italy) and a smartwatch (Apple Watch Series 3). Participants performed standardized arm movements while sensor signals were synchronized and processed to extract relevant features. Statistical analyses assessed discriminant and concurrent validity, reliability, and accuracy. The algorithm demonstrated moderate to strong correlations between smartwatch and commercial IMU data, effectively distinguishing individuals with PD from healthy controls showing associations with clinical measures, such as the MDS-UPDRS III. Reliability analysis demonstrated agreement between repeated measurements, although a proportional bias was noted. Power spectral density (PSD) analysis of accelerometer and gyroscope data along the x-axis successfully detected the presence of tremors. These findings support the use of smartwatches as a tool for detecting tremors in PD. However, further studies involving larger and more clinically impaired samples are needed to confirm the robustness and generalizability of these results.<\/jats:p>","DOI":"10.3390\/s25144313","type":"journal-article","created":{"date-parts":[[2025,7,11]],"date-time":"2025-07-11T10:26:53Z","timestamp":1752229613000},"page":"4313","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Smart Watch Sensors for Tremor Assessment in Parkinson\u2019s Disease\u2014Algorithm Development and Measurement Properties Analysis"],"prefix":"10.3390","volume":"25","author":[{"given":"Giulia Palermo","family":"Schifino","sequence":"first","affiliation":[{"name":"Movement Analysis and Rehabilitation Laboratory, Universidade Federal de Ci\u00eancias da Sa\u00fade de Porto Alegre (UFCSPA), Porto Alegre 90050-170, Brazil"},{"name":"Rehabilitation Sciences Graduate Program, Universidade Federal de Ci\u00eancias da Sa\u00fade de Porto Alegre (UFCSPA), Porto Alegre 90050-170, Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maira Jaqueline","family":"da Cunha","sequence":"additional","affiliation":[{"name":"Movement Analysis and Rehabilitation Laboratory, Universidade Federal de Ci\u00eancias da Sa\u00fade de Porto Alegre (UFCSPA), Porto Alegre 90050-170, Brazil"},{"name":"Rehabilitation Sciences Graduate Program, Universidade Federal de Ci\u00eancias da Sa\u00fade de Porto Alegre (UFCSPA), Porto Alegre 90050-170, Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7666-8475","authenticated-orcid":false,"given":"Ritchele Redivo","family":"Marchese","sequence":"additional","affiliation":[{"name":"Movement Analysis and Rehabilitation Laboratory, Universidade Federal de Ci\u00eancias da Sa\u00fade de Porto Alegre (UFCSPA), Porto Alegre 90050-170, Brazil"},{"name":"Rehabilitation Sciences Graduate Program, Universidade Federal de Ci\u00eancias da Sa\u00fade de Porto Alegre (UFCSPA), Porto Alegre 90050-170, Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8786-6258","authenticated-orcid":false,"given":"Vinicius","family":"Mab\u00edlia","sequence":"additional","affiliation":[{"name":"Movement Analysis and Rehabilitation Laboratory, Universidade Federal de Ci\u00eancias da Sa\u00fade de Porto Alegre (UFCSPA), Porto Alegre 90050-170, Brazil"},{"name":"Department of Physical Therapy, Universidade Federal de Ci\u00eancias da Sa\u00fade de Porto Alegre (UFCSPA), Porto Alegre 90050-170, Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Luis Henrique Amoedo","family":"Vian","sequence":"additional","affiliation":[{"name":"Movement Analysis and Rehabilitation Laboratory, Universidade Federal de Ci\u00eancias da Sa\u00fade de Porto Alegre (UFCSPA), Porto Alegre 90050-170, Brazil"},{"name":"Department of Physical Therapy, Universidade Federal de Ci\u00eancias da Sa\u00fade de Porto Alegre (UFCSPA), Porto Alegre 90050-170, Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Francisca dos Santos","family":"Pereira","sequence":"additional","affiliation":[{"name":"Movement Analysis and Rehabilitation Laboratory, Universidade Federal de Ci\u00eancias da Sa\u00fade de Porto Alegre (UFCSPA), Porto Alegre 90050-170, Brazil"},{"name":"Department of Physical Therapy, Universidade Federal de Ci\u00eancias da Sa\u00fade de Porto Alegre (UFCSPA), Porto Alegre 90050-170, Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6299-7254","authenticated-orcid":false,"given":"Veronica","family":"Cimolin","sequence":"additional","affiliation":[{"name":"Department of Electronics, Information and Bioengineering, Politecnico di Milano, 20133 Milan, Italy"},{"name":"IRCCS Istituto Auxologico Italiano, 28824 Piancavallo, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7837-5855","authenticated-orcid":false,"given":"Aline Souza","family":"Pagnussat","sequence":"additional","affiliation":[{"name":"Movement Analysis and Rehabilitation Laboratory, Universidade Federal de Ci\u00eancias da Sa\u00fade de Porto Alegre (UFCSPA), Porto Alegre 90050-170, Brazil"},{"name":"Rehabilitation Sciences Graduate Program, Universidade Federal de Ci\u00eancias da Sa\u00fade de Porto Alegre (UFCSPA), Porto Alegre 90050-170, Brazil"},{"name":"Department of Physical Therapy, Universidade Federal de Ci\u00eancias da Sa\u00fade de Porto Alegre (UFCSPA), Porto Alegre 90050-170, Brazil"},{"name":"Health Sciences Graduate Program, Universidade Federal de Ci\u00eancias da Sa\u00fade de Porto Alegre (UFCSPA), Porto Alegre 90050-170, Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2025,7,10]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"235","DOI":"10.1016\/S1474-4422(06)70373-8","article-title":"Non-motor symptoms of Parkinson\u2019s disease: Diagnosis and management","volume":"5","author":"Chaudhuri","year":"2006","journal-title":"Lancet Neurol."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1016\/j.parkreldis.2009.08.007","article-title":"A timeline for Parkinson\u2019s disease","volume":"16","author":"Hawkes","year":"2010","journal-title":"Parkinsonism Relat. Disord."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"1150","DOI":"10.1002\/mds.23100","article-title":"Timed motor tests can detect subtle motor dysfunction in early Parkinson\u2019s disease","volume":"25","author":"Haaxma","year":"2010","journal-title":"Mov. Disord."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"1701","DOI":"10.1002\/mds.22199","article-title":"Poor dopaminergic response of impaired dexterity in Parkinson\u2019s disease: Bradykinesia or limb kinetic apraxia?","volume":"23","author":"Gebhardt","year":"2008","journal-title":"Mov. Disord."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"794","DOI":"10.1016\/j.apmr.2010.01.008","article-title":"Skilled hand dexterity in Parkinson\u2019s disease: Effects of adding a concurrent task","volume":"91","author":"Proud","year":"2010","journal-title":"Arch. Phys. Med. Rehabil."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1016\/S1353-8020(00)00079-1","article-title":"Longitudinal evaluation of economic and physical impact of Parkinson\u2019s disease","volume":"8","author":"Schenkman","year":"2001","journal-title":"Parkinsonism Relat. Disord."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1016\/j.parkreldis.2020.05.034","article-title":"Validation of a UPDRS-\/MDS-UPDRS-based definition of functional dependency for Parkinson\u2019s disease","volume":"76","author":"Ramsay","year":"2020","journal-title":"Parkinsonism Relat. Disord."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"540","DOI":"10.1016\/j.apmr.2014.09.016","article-title":"Evaluation of measures of upper limb functioning and disability in people with Parkinson disease: A systematic review","volume":"96","author":"Proud","year":"2015","journal-title":"Arch. Phys. Med. Rehabil."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"386","DOI":"10.5014\/ajot.39.6.386","article-title":"Adult norms for the Box and Block Test of manual dexterity","volume":"39","author":"Mathiowetz","year":"1985","journal-title":"Am. J. Occup. Ther."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"1507","DOI":"10.1088\/0967-3334\/28\/12\/005","article-title":"Analysis of surface EMG signal morphology in Parkinson\u2019s disease","volume":"28","author":"Rissanen","year":"2007","journal-title":"Physiol. Meas."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"e206","DOI":"10.1016\/j.jelekin.2008.02.008","article-title":"Novel parameters of surface EMG in patients with Parkinson\u2019s disease and healthy young and old controls","volume":"19","author":"Meigal","year":"2009","journal-title":"J. Electromyogr. Kinesiol."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"313","DOI":"10.1109\/TBME.2006.886670","article-title":"Quantification of tremor and bradykinesia in Parkinson\u2019s disease using a novel ambulatory monitoring system","volume":"54","author":"Salarian","year":"2007","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"2296","DOI":"10.1109\/TBME.2007.896591","article-title":"Ambulatory monitoring of physical activities in patients with Parkinson\u2019s disease","volume":"54","author":"Salarian","year":"2007","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_14","doi-asserted-by":"crossref","unstructured":"Thanawattano, C., Pongthornseri, R., Anan, C., Dumnin, S., and Bhidayasiri, R. (2015). Temporal fluctuations of tremor signals from inertial sensor: A preliminary study in differentiating Parkinson\u2019s disease from essential tremor. Biomed. Eng. Online, 14.","DOI":"10.1186\/s12938-015-0098-1"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"70","DOI":"10.1186\/1743-0003-10-70","article-title":"Power spectral density analysis of physiological, rest and action tremor in Parkinson\u2019s disease patients treated with deep brain stimulation","volume":"10","author":"Heida","year":"2013","journal-title":"J. Neuroeng. Rehabil."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"25055","DOI":"10.3390\/s151025055","article-title":"Quantitative Assessment of Parkinsonian Tremor Based on an Inertial Measurement Unit","volume":"15","author":"Dai","year":"2015","journal-title":"Sensors"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"723","DOI":"10.1002\/mds.22445","article-title":"Clinically deployable Kinesia technology for automated tremor assessment","volume":"24","author":"Giuffrida","year":"2009","journal-title":"Mov. Disord."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"280","DOI":"10.1097\/00002826-200109000-00004","article-title":"Ambulatory objective assessment of tremor in Parkinson\u2019s disease","volume":"24","author":"Hoff","year":"2001","journal-title":"Clin. Neuropharmacol."},{"key":"ref_19","unstructured":"Cole, B.T., Roy, S.H., De Luca, C.J., and Nawab, S. (September, January 31). Dynamic neural network detection of tremor and dyskinesia from wearable sensor data. Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Buenos Aires, Argentina."},{"key":"ref_20","doi-asserted-by":"crossref","unstructured":"Daneault, J.-F., Carignan, B., Cod\u00e8re, C.\u00c9., Sadikot, A.F., and Duval, C. (2012). Using a smart phone as a standalone platform for detection and monitoring of pathological tremors. Front. Hum. Neurosci., 6.","DOI":"10.3389\/fnhum.2012.00357"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"1835","DOI":"10.1109\/JBHI.2015.2471093","article-title":"A Smartphone-Based Tool for Assessing Parkinsonian Hand Tremor","volume":"19","author":"Kostikis","year":"2015","journal-title":"IEEE J. Biomed. Health Inform."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.jneumeth.2014.04.021","article-title":"Smart watch accelerometry for analysis and diagnosis of tremor","volume":"230","author":"Wile","year":"2014","journal-title":"J. Neurosci. Methods"},{"key":"ref_23","doi-asserted-by":"crossref","unstructured":"Prieto-Avalos, G., S\u00e1nchez-Morales, L.N., Alor-Hern\u00e1ndez, G., and S\u00e1nchez-Cervantes, J.L. (2022). A Review of Commercial and Non-Commercial Wearables Devices for Monitoring Motor Impairments Caused by Neurodegenerative Diseases. Biosensors, 13.","DOI":"10.3390\/bios13010072"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"344","DOI":"10.1016\/j.jclinepi.2007.11.008","article-title":"The Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) statement: Guidelines for reporting observational studies","volume":"61","author":"Altman","year":"2008","journal-title":"J. Clin. Epidemiol."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"826","DOI":"10.1148\/radiol.2015151516","article-title":"STARD 2015: An Updated List of Essential Items for Reporting Diagnostic Accuracy Studies","volume":"277","author":"Bossuyt","year":"2015","journal-title":"Radiology"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"368","DOI":"10.1136\/jnnp.2007.131045","article-title":"Parkinson\u2019s disease: Clinical features and diagnosis","volume":"79","author":"Jankovic","year":"2008","journal-title":"J. Neurol. Neurosurg. Psychiatry"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"605","DOI":"10.1590\/S0004-282X1998000400014","article-title":"[Mini mental state examination and the diagnosis of dementia in Brazil]","volume":"56","author":"Almeida","year":"1998","journal-title":"Arq. Neuropsiquiatr."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"323","DOI":"10.1080\/02640414.2021.1993640","article-title":"Quantifying cricket fast bowling volume, speed and perceived intensity zone using an Apple Watch and machine learning","volume":"40","author":"McGrath","year":"2022","journal-title":"J. Sports Sci."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"1020","DOI":"10.1002\/mds.20213","article-title":"Movement Disorder Society Task Force report on the Hoehn and Yahr staging scale: Status and recommendations","volume":"19","author":"Goetz","year":"2004","journal-title":"Mov. Disord."},{"key":"ref_30","doi-asserted-by":"crossref","unstructured":"Ponsiglione, A.M., Ricciardi, C., Amato, F., Cesarelli, M., Cesarelli, G., and D\u2019addio, G. (2022). Statistical Analysis and Kinematic Assessment of Upper Limb Reaching Task in Parkinson\u2019s Disease. Sensors, 22.","DOI":"10.3390\/s22051708"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"1273","DOI":"10.1136\/jnnp.49.11.1273","article-title":"Scaling of the size of the first agonist EMG burst during rapid wrist movements in patients with Parkinson\u2019s disease","volume":"49","author":"Berardelli","year":"1986","journal-title":"J. Neurol. Neurosurg. Psychiatry"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"411","DOI":"10.5604\/12321966.1232774","article-title":"Motor assessment in Parkinson;s disease","volume":"24","author":"Opara","year":"2017","journal-title":"Ann. Agric. Environ. Med."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"864","DOI":"10.1109\/TITB.2009.2033471","article-title":"Monitoring motor fluctuations in patients with Parkinson\u2019s disease using wearable sensors","volume":"13","author":"Patel","year":"2009","journal-title":"IEEE Trans. Inf. Technol. Biomed."},{"key":"ref_34","unstructured":"Jia, X., Duroseau, N., Chan, V., Ciraco, C., Wang, R., Nia, S.M., Ho, K., Govindavari, J.P., Delgosha, F., and Chan, T. (2014, January 26\u201330). Objective quantification of upper extremity motor functions in Unified Parkinson\u2019s Disease Rating Scale Test. Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Chicago, IL, USA."},{"key":"ref_35","unstructured":"Hoffman, J.D., and McNames, J. (September, January 30). Objective measure of upper extremity motor impairment in Parkinson\u2019s disease with inertial sensors. Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Boston, MA, USA."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"440","DOI":"10.1016\/j.parkreldis.2008.11.003","article-title":"Opening velocity, a novel parameter, for finger tapping test in patients with Parkinson\u2019s disease","volume":"15","author":"Yokoe","year":"2009","journal-title":"Parkinsonism Relat. Disord."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"561","DOI":"10.1136\/jnnp.50.5.561","article-title":"Frequency\/amplitude characteristics of postural tremor of the hands in a population of patients with bilateral essential tremor: Implications for the classification and mechanism of essential tremor","volume":"50","author":"Calzetti","year":"1987","journal-title":"J. Neurol. Neurosurg. Psychiatry"},{"key":"ref_38","first-page":"2700110","article-title":"Quantifying Tremor in Essential Tremor Using Inertial Sensors-Validation of an Algorithm","volume":"9","author":"Mcgurrin","year":"2021","journal-title":"IEEE J. Transl. Eng. Health Med."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"7304205050p1","DOI":"10.5014\/ajot.2019.031112","article-title":"Measuring Hand Dexterity in People With Parkinson\u2019s Disease: Reliability of Pegboard Tests","volume":"73","author":"Proud","year":"2019","journal-title":"Am. J. Occup. Ther."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"3834","DOI":"10.1080\/09638288.2020.1754474","article-title":"Hand dexterity assessment in Parkinson\u2019s disease: Construct validity of the 9-Hole peg test for the more affected hand","volume":"43","author":"Proud","year":"2021","journal-title":"Disabil. Rehabil."},{"key":"ref_41","first-page":"231","article-title":"Quantifying test-retest reliability using the intraclass correlation coefficient and the SEM","volume":"19","author":"Weir","year":"2005","journal-title":"J. Strength. Cond. Res."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"1","DOI":"10.2165\/00007256-200030010-00001","article-title":"Measures of reliability in sports medicine and science","volume":"30","author":"Hopkins","year":"2000","journal-title":"Sports Med."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"283","DOI":"10.1016\/S0001-2998(78)80014-2","article-title":"Basic principles of ROC analysis","volume":"8","author":"Metz","year":"1978","journal-title":"Semin. Nucl. Med."},{"key":"ref_44","doi-asserted-by":"crossref","unstructured":"Channa, A., Ifrim, R.-C., Popescu, D., and Popescu, N. (2021). A-WEAR Bracelet for Detection of Hand Tremor and Bradykinesia in Parkinson\u2019s Patients. Sensors, 21.","DOI":"10.3390\/s21030981"},{"key":"ref_45","first-page":"6139716","article-title":"Quantitative Analysis of Motor Status in Parkinson\u2019s Disease Using Wearable Devices: From Methodological Considerations to Problems in Clinical Applications","volume":"2017","author":"Suzuki","year":"2017","journal-title":"Parkinsons Dis."},{"key":"ref_46","doi-asserted-by":"crossref","unstructured":"McNames, J., Shah, V.V., Mancini, M., Curtze, C., El-Gohary, M., Aboy, M., Carlson-Kuhta, P., Nutt, J.G., and Fay, H. (2019, January 23\u201327). A Two-Stage Tremor Detection Algorithm for Wearable Inertial Sensors During Normal Daily Activities. Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Berlin, Germany.","DOI":"10.1109\/EMBC.2019.8857133"},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.gaitpost.2007.10.010","article-title":"Accelerometry: A technique for quantifying movement patterns during walking","volume":"28","author":"Kavanagh","year":"2008","journal-title":"Gait Posture"},{"key":"ref_48","doi-asserted-by":"crossref","unstructured":"Hess, C.W., and Pullman, S.L. (2012). Tremor: Clinical phenomenology and assessment techniques. Tremor Other Hyperkinet Mov., 2.","DOI":"10.5334\/tohm.115"},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1002\/mds.870131303","article-title":"Consensus statement of the Movement Disorder Society on Tremor. Ad Hoc Scientific Committee","volume":"13","author":"Deuschl","year":"1998","journal-title":"Mov. Disord."},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"75","DOI":"10.1002\/mds.27121","article-title":"Consensus Statement on the classification of tremors. from the task force on tremor of the International Parkinson and Movement Disorder Society","volume":"33","author":"Bhatia","year":"2018","journal-title":"Mov. Disord."},{"key":"ref_51","doi-asserted-by":"crossref","unstructured":"Buijink, A.W.G., Contarino, M.F., Koelman, J.H.T.M., Speelman, J.D., and van Rootselaar, A.F. (2012). How to tackle tremor\u2014Systematic review of the literature and diagnostic work-up. Front. Neurol., 3.","DOI":"10.3389\/fneur.2012.00146"},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"371","DOI":"10.3233\/JPD-150708","article-title":"Validation of a Smartphone Application Measuring Motor Function in Parkinson\u2019s Disease","volume":"6","author":"Lee","year":"2016","journal-title":"J. Parkinsons Dis."},{"key":"ref_53","doi-asserted-by":"crossref","unstructured":"Pendt, L.K., Reuter, I., and M\u00fcller, H. (2011). Motor skill learning, retention, and control deficits in Parkinson\u2019s disease. PLoS ONE, 6.","DOI":"10.1371\/journal.pone.0021669"},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"850","DOI":"10.4338\/ACI-2016-03-R-0042","article-title":"Healthcare Applications of Smart Watches. A Systematic Review","volume":"7","author":"Lu","year":"2016","journal-title":"Appl. Clin. Inform."},{"key":"ref_55","doi-asserted-by":"crossref","unstructured":"Iakovakis, D., Mastoras, R.E., Hadjidimitriou, S., Charisis, V., Bostanjopoulou, S., Katsarou, Z., Klingelhoefer, L., Reichmann, H., Trivedi, D., and Chaudhuri, R.K. (2020, January 20\u201324). Smartwatch-based Activity Analysis During Sleep for Early Parkinson\u2019s Disease Detection. Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Montreal, QC, Canada.","DOI":"10.1109\/EMBC44109.2020.9176412"},{"key":"ref_56","doi-asserted-by":"crossref","first-page":"478","DOI":"10.1109\/TITB.2011.2182616","article-title":"Assessment of tremor activity in the Parkinson\u2019s disease using a set of wearable sensors","volume":"16","author":"Rigas","year":"2012","journal-title":"IEEE Trans. Inf. Technol. Biomed."},{"key":"ref_57","doi-asserted-by":"crossref","first-page":"849","DOI":"10.1007\/s11517-008-0369-0","article-title":"Surface EMG and acceleration signals in Parkinson\u2019s disease: Feature extraction and cluster analysis. Med","volume":"46","author":"Rissanen","year":"2008","journal-title":"Biol. Eng. Comput."},{"key":"ref_58","doi-asserted-by":"crossref","unstructured":"Kostikis, N., Hristu-Varsakelis, D., Arnaoutoglou, M., and Kotsavasiloglou, C. (2014, January 26\u201330). Smartphone-based evaluation of parkinsonian hand tremor: Quantitative measurements vs clinical assessment scores. Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Chicago, IL, USA.","DOI":"10.1109\/EMBC.2014.6943738"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/25\/14\/4313\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,9]],"date-time":"2025-10-09T18:07:59Z","timestamp":1760033279000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/25\/14\/4313"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,7,10]]},"references-count":58,"journal-issue":{"issue":"14","published-online":{"date-parts":[[2025,7]]}},"alternative-id":["s25144313"],"URL":"https:\/\/doi.org\/10.3390\/s25144313","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,7,10]]}}}